Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Active Power Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Play Fairway Analysis: Structurally Controlled Geothermal Systems in the Eastern Great Basin Extensional Regime, Utah

A research team with membership from the University of Utah/Energy & Geoscience Institute, the University of Utah/Dept. of Geology & Geophysics, and the Utah Geological Survey, undertook a play fairway analysis (PFA) for geothermal resources in the Eastern Great Basin (EGB) extensional tectonic regime of western Utah. This is a high-priority region for geothermal exploration because active Basin and Range (B&R) extension with volcanism having a N-S strike is superimposed upon pre-existing E-W belts of plutonic rocks and large-scale structural lineaments. Cumulative heat flow along the N-S strike of the state totals approximately 5 GWt above background stable interior. Three electricity producing power plants currently exist with substantial potential for increase. Succinctly, our PFA approach aims to resolve potential sources of heat and permeability in the region, which are the two principal criteria for establishing a geothermal resource. An initial Phase 1 was carried out using only existing geoscientific data in the area. Criteria selected for focusing heat potential include direct heat flow measurements in boreholes, magnetotelluric (MT) low resistivity anomalies, fluid/gas geochemistry, and proximity to recent volcanic eruptions. Permeability is established through geological structures (fault density, critically stressed areas, seismicity, gravity), and MT low resistivity anomalies. In Phase II of this PFA project, additional geological, geophysical and geochemical data were acquired and analysis carried out primarily over promising composite common risk (CCR) areas initially identified in Phase I in order to focus prospectivity and prepare for drilling recommendations. These prospects are near the Twin Peaks rhyolite field, high heat flow areas north of the producing Cove Fort system, and geophysical structure beneath the Crater Knoll area off the northeast flank of the Mineral Mountains. Additional data included MT site fill-in, structural mapping and analysis using high-resolution imagery, gravity and on-ground mapping, Nodal 3C passive seismic collection, and passive 3He surveying. Heat source and permeability potential are again expressed in terms of their individual common risk segment (CRS) maps, with a color scheme using green for most favorable (low risk) and red for least favorable (high risk). Diverse data types are united through the technique of probability kriging, which establishes prospectivity thresholds for each data type and then computes probability of exceeding that threshold over the PFA area. Modified CRS and CCRS maps are compared to those of Phase I to highlight tighter prospectivity focus. In doing so, the prospectivity threshold for heat was increased significantly to narrow the targeting. In the final Phase III of this project where a recommended deep thermal gradient hole was sited, additional geophysical, geochemical and geological field collection and analysis was carried out to refine drill hole targeting. This includes prospect-scale MT, gravity, structure, passive seismic deployment (Cove Fort area), and detailed 3He isotope profiling. It was the recommendation of the DOE Technical Monitoring Team (TMT) that one or more holes be sited in the north-ern Cove Fort area where legacy TG gradient holes showed high cumulative heat flow. These were to be of moderate depth, 2000-3000 feet, to reach the geothermal fluid table expected to start in excess of 1000 feet depth. The drilling organization stipulated by the DOE/GTO was that of the USGS Research Drilling Program (RDP) centered in Las Vegas, NV. A detailed well plan, appended to this report, was developed principally by Dr. Ben Barker consulting to University of Utah, Dr. Steve Pye on the DOE TMT, Mr. Steven Crawford of the USGS-RDP, and the project PI Phil Wannamaker. However, temperature and possible H 2 S at the systems lead to cancellation of the drilling last-minute as this appeared outside the experience base of the USGS-RDP. We hope to have the opportunity to revisit the test drilling and expand the Play Fairway Analysis of this region at some point in the future.

15 GEOTHERMAL ENERGY↗

Comparison of model high-lititude electron densities with Millstone Hill observations

The predictions of a high-latitude ionospheric model are compared with the diurnal variations of plasma convection velocities and electron densities observed at Millstone Hill on a geomagnetically moderately active day near equinox. The observed convection pattern was consistent with a two-cell, asymmetric pattern with enhanced plasma flow in the dusk sector, with flow speeds reaching 1.5 km/s. In the dusk strong convection cell, the falloff of the magnetospheric potential with latitude was proportional to the inverse of the sine of colatitude to the fourth power. On the dayside, a region of high density occurred at 500 km in the 1000-1900 LT sector. The nocturnal midlatitude trough was deepest and widest and reached its most equatorward position in the morning sector. The model, which is based on average auroral precipitation fluxes, can describe the gross features of the enhanced densities in the auroral zone.

Sojka, J. J.↗

High Heat Flow from Enceladus' South Polar Region Measured using 10-600/cm(exp -1) Cassini/CIRS Data

Analysis of 2008 Cassini Composite Infrared Spectrometer (CIRS) 10 to 600/cm thermal emission spectra of Enceladus shows that for reasonable assumptions about the spatial distribution of the emission and the thermophysical properties of the solar-heated background surface, which are supported by CIRS observations of background temperatures at the edge of the active region, the endogenic power of Enceladus' south polar terrain is 15.8 +/- 3.1 GW. This is significantly higher than the previous estimate of 5.8 +/- 1.9 GW. The new value represents an improvement over the previous one, which was derived from higher wave number data (600 to 1100/cm-I) and was thus only sensitive to high-temperature emission. The mechanism capable of producing such a high endogenic power remains a mystery and challenges the current models of proposed heat production.

Howett, C. J. A.↗

Annual Stormwater Report for the Y-12 National Security Complex Oak Ridge, Tennessee

This is the ninth annual stormwater report prepared in accordance with the modified National Pollutant Discharge Elimination System permit issued to the Y-12 National Security Complex (Y-12) on April 1, 2014. This modified permit removed the authorization to augment flow in East Fork Poplar Creek (EFPC) and thus removed the requirement to sample this effluent in conjunction with other major outfalls on EFPC. There are several construction and demolition activities currently in progress at Y-12. These include the construction of the Uranium Processing Facility (UPF), the Mercury Treatment Facility (MTF) on EFPC, the site-wide power grid upgrade, construction of an Emergency Operations Center, construction of a new Fire Station, Security Improvement Revitalization Program (SIRP), West End Protection Area Reduction (WEPAR) Project, and the demolition of the Biology Complex. Current stormwater protections have proven effective in 2021. However, moving forward, challenges to protect stormwater will continue from these projects. Therefore, oversight of these activities, and all other construction and demolition projects, will continue to be a priority in 2022. Y-12 will continue to implement appropriate Best Management Practices and reduce outside material storage areas where possible.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

HCOO - aq Degradation in Droplets by OH aq in an Atmospheric Pressure Glow Discharge

Plasmas in contact with liquids can degrade organic molecules in solution, as reactive oxygen and nitrogen species produced in the plasma solvate into the liquid. Immersing small droplets (tens of microns in diameter) in the plasma can more rapidly activate the liquid compared to treating a large volume of liquid with a smaller surface-to-volume ratio. The interactions between a radio frequency glow discharge sustained in He/H 2 O and a water droplet containing formate (HCOO - aq ) immersed in and flowing through the plasma were modeled using a 0-dimensional global plasma chemistry model to investigate these activation processes. HCOO - aq interacts with OH aq , produced from solvation of OH from the gas phase. HCOO - aq concentrations were benchmarked with previously reported experimental measurements. The diameter of the droplet, initial HCOO - aq concentration, and gas flow rate affect only the HCOO - aq concentration and OH aq density, leaving the OH density in the gas phase unaffected. Power deposition and gas mixture (e.g., percentage of H 2 O) change both the gas and liquid phase chemistry. A general trend was observed – during the first portion of droplet exposure to the plasma, OH aq primarily consumes HCOO - aq . However, O2 - aq , a byproduct of HCOO - aq consumption, consumes OH aq once O2 - aq reaches a critically large density. Using HCOO - aq as a surrogate for OH aq sensitive contaminants, combinations of residence time, droplet diameter, water vapor density, and power will determine the optimum remediation strategy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Power and isotope effects in the ITER baseline scenario with tungsten and tungsten-equivalent radiators in DIII-D

Abstract Experiments in DIII-D document the ITER Baseline Scenario (IBS) at q 95 ∼ 3 and P IN / P LH ∼ 1–2, in both deuterium and hydrogen utilizing Kr and Xe as Tungsten-equivalent radiators. The power threshold for H-mode operation ( P LH ) was determined experimentally without added impurities and found to be about a factor of two higher than the scaling law. In recent IBS experiments in deuterium, intrinsic levels of metals such as Tungsten (W) or molybdenum and inconel are present that reduce the pedestal pressure by 20%–25%. A complete radiative collapse of deuterium IBS plasmas occurs at W core concentrations C W = 10 −5 . Simulations show that for core temperatures expected for ITER, the plasmas would not have a radiative collapse at C W = 1 × 10 −5 , moreover Q = 8–10 would still be achieved for C W up to 3 × 10 −5 . In contrast to deuterium, the IBS in hydrogen is not affected by intrinsic high-Z impurities, indicating that hydrogen H-modes in ITER may not inform the D-T phase with respect to W accumulation and discharge survival. Compared to deuterium, the pedestal pressure in hydrogen is ∼25% lower, with much higher ELM frequency of 150 Hz, decreasing with input power. Krypton was injected in a matrix scan of input power and impurity flow in IBS hydrogen discharges. Krypton impurity density profiles in hydrogen are similar to deuterium plasmas, but at Kr flows that are 2–3 times higher for the same input power. Krypton is transported into the core and affects the whole radius; at the highest injection rates a radiative collapse occurs at core radiation fractions of 0.3–0.35, consistent with the expected maximum W radiation fraction for ITER core plasmas. Comparing the results with previous International Tokamak Physics Activity database studies of the IBS confirms that at higher radiation fraction due to high-Z impurities, a drop in H 98 of >10% is observed. On the other hand, the results using Kr as a W-equivalent radiator indicate that metal (W) devices at lower core temperatures than ITER may provide overly pessimistic performance extrapolations to ITER for deuterium-tritium operation. The new DIII-D results support a more attractive option for the ITER Research Plan with a short hydrogen phase for system commissioning, transitioning to deuterium operations as soon as possible to provide relevant conditions for deuterium-tritium operations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Binder-Coated Carbon Cloth Electrodes for All-Vanadium Redox Flow Batteries

Vanadium redox flow batteries (VRFBs) are a promising solution for integrating intermittent renewable energy sources into the existing power grid. However, enhancing the electrochemical performance of VRFBs is critical for their widespread adoption in grid-scale energy storage. This study investigates the impact of adding a porous binder to a carbon-cloth electrode, with a focus on optimizing thermal activation conditions. The electrochemical performance of the binder-coated electrodes compared to uncoated electrodes is evaluated through electrochemical impedance spectroscopy, polarization curve measurements, and charge-discharge cycling. The surface morphology and structural integrity of the binder-coated electrodes at each activation stage are examined using various material characterization techniques to assess the effects of thermal activation. The results are benchmarked against the experiments using non-coated electrodes to determine the performance improvements offered by the binder coating. Notably, the study reveals that binder-coated electrodes exhibit significantly lower resistance and improved efficiency compared to their uncoated counterparts, with optimal activation conditions enhancing performance metrics crucial for VRFB applications. These findings provide valuable insights for further optimizing electrode design and activation strategies, advancing the development of more efficient VRFB systems for large-scale energy storage.

Caiado, Ashley A.↗

Perovskite Sorbent Oxygen Separation Modeling with MFiX

This document chronicles the development and implementation of computational kinetic rate models that capture absorption and desorption characteristics of the National Energy Technology Laboratory (NETL) developed perovskite, Sr 1-x Ca x FeO 3-δ . Two paths to create accurate kinetic rates were followed: (1) an isothermal rate approach where thermogravimetric (TGA) data are recast as oxygen capacities through a pseudo-second order Lagergren equation (He et al., 2009); and (2) a more traditional Arrhenius approach where experimental data are fit with a power law model to derive associate activation energies (Bulfin et al., 2020a). For reference, the mathematics and associate experimental strategies that support these derivations are included in this report. In addition, computational fluid dynamics (CFD) models were developed to utilize both kinetic rate formulations and applied to simulate oxygen uptake and release in small scale scenarios. The program Multiphase Flow with interphase eXchanges (MFiX) was used to create: (1) discrete element method (DEM) simulations of a single tube of granular perovskite experiencing isothermal O 2 -absorption; and desorption and (2) two-fluid-model (TFM) non-isothermal simulations of perovskite O 2 -absorption and desorption tubes that share a wall. Conjugate heat transfer between steel walled tubes and the perovskite bed were managed with user-defined functions. As the project moves to simulating larger scale devices that will require more robust conjugate heat transfer methods, developed kinetic rates and associate methodologies have been recast for use in the ANSYS Fluent CFD program.

36 MATERIALS SCIENCE↗

Lunar Mega Project: Processes, Work Flow and Terminology of the Terrestrial Construction Industry versus the Space Industry

Recent developments around the world show an increased interest and international activity toward developing a lunar surface human and robotic presence with a long term, sustainable vision. In Europe, the construction of a "Moon Village" has been proposed, and China has stated its intention to build a research station with a crew at the lunar South Pole. Russia stated it will land cosmonauts on the Moon in the 2030's. India has sent an orbiter, a robotic lander, and rover to the Moon. The USA intends to land the first woman and a man on the Moon by 2024 to initiate a sustained human lunar presence.A lunar research station with associated commercial activities will require infrastructure to become a permanent capability. Landing and launch pads, propellant storage and distribution farms, spacecraft access and handling structures, cranes, blast protection berms or walls, roads, graded areas, dust stabilized areas, foundations, parking lots, radiation shelters, micro-meteorite protection hangars, habitats and other human shelters, greenhouse farms, utility trenches, power plants, industrial water and oxygen extraction plants, communications antenna towers, thermal protection, mining zones, crater access and sub-surface access will be required to create a safe and sustainable lunar operations capability. This infrastructure will require significant construction activities in an extreme environment, with risky and expensive operations. On Earth, there are similar large and expensive projects (>$1 Billion) in difficult locations that attract a lot of public attention. These are known as "Mega Projects" and examples include bridges, tunnels, highways, railways, airports, seaports, power plants, dams, wastewater projects, Special Economic Zones (SEZ), oil and natural gas extraction projects, public buildings, information technology systems, aerospace projects, and weapons systems. Large consortiums consisting of public and private entities typically implement these infrastructure Mega-Projects.This paper will compare the typical design process, project management process, and work flow in the terrestrial construction industry to the space industry in order to create a better understanding between the terrestrial construction industry and the space industry, to further enable collaboration on a lunar Mega Project to build infrastructure on the Moon. In addition, a glossary of respective industry terminology with annotated linkages and definitions has been compiled. This information will enable contracts and business practices to be formulated for generating requests for proposals (RFP) by governments to consortiums consisting of construction and space industry companies that will bid on Lunar Infrastructure Projects that could lead to contracts to build the permanent capabilities.

Robert P Mueller↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗

A dynamic solar-electric power/thermal control system for spacecraft.

This paper describes a solar-electric power and active thermal control system for spacecraft with solar energy to electricity conversion efficiency of more than 20%. Briefly, the solar heat energy is absorbed by flat plate collectors yielding above 70% of the energy incident for conversion by an organic condensing cycle. The cycle operates between 132 and 6.67 deg C. The working fluid is F-114 which flows through a solar collector to absorb heat, then through a regenerator and into the radiator where it is condensed to a liquid. The cold liquid flows through two paths, one providing regenerator cooling, the other providing spacecraft thermal control. The system total weight is about 170kg/kW of electrical energy produced. The dynamic system replaces batteries by a thermal capacitor for eclipse period energy storage, thereby eliminating many battery charging and control problems as well as improving efficiency and weight characteristics of the system.

Davis, B. K.↗

A pumped two-phase cooling system for spacecraft

A pumped, two-phase heat-transport system is being developed for possible use for temperature control of scientific instruments on future NASA missions. As compared to a single-phase system, this two-phase system can maintain tighter temperature control with less pumping power. A laboratory model of the system has been built and tested. The measured heat transfer coefficients were approximately the same as in heat pipes, 220 Btu/hr-sq ft-F, as compared to 25 Btu/hr-sq ft-F for single-phase liquid flow. Heat shearing between experiments has been demonstrated wherein vapor generated in the cold plate of an active experiment was condensed in a cold, unheated experiment. System stability has been observed. However, additional development is needed. The use of non-azeotropic mixtures of coolants appears especially promising as a simple way to determine exit quality and thus control the flow rates to prevent dryout.

Ollendorf, S.↗

Multiple flow velocities in the transition region

Observations with the High Resolution Telescope and Spectrograph (HRTS) of the C IV lines at 1550 A above sunspots reveal the coexistence of several distinct high velocity gas components within the instrument resolution element of 1 x 1 arcsec. A further investigation of the HRTS material demonstrates that such multiple gas velocities are not restricted to the temperature region around 100,000 K, where the C IV lines are formed, but that the gas flows with essentially unchanged speed through all temperature layers from 250,000 K to 10,000 K. Furthermore, the phenomenon is not restricted to sunspots, but occurs also in other solar regions, often most easily distinguished in active regions. The characteristics of the velocity fields are described. The mass fluxes are analyzed, and the requirements they place on the resolving power of future space instruments are discussed.

Brekke, P.↗

Inductively-Activated Short-Interval Timer

Timing circuit in pneumatically launched projectile triggers explosive charge in projectile at specified delay after launch. Both power and control signals coupled inductively to timer from stationary launcher circuitry. Eliminates need for direct electrical contacts, which are unreliable and generate sparks that trigger explosive accidentally. Inductive coupling also provides higher reliability in field operation than contacts. Concept useful in such other safety-related applications as remotely or automatically controlling flow of bottled flammable gas.

Wiker, Gordon A.↗

Solid State Quantum Refrigeration Superconducting, Absorption and Measurement Based (Final Technical Report)

During this DOE grant, DE-SC0017890, in place for the past six years, all proposed research was carried out and published in peer-reviewed papers, as well as other projects that emerged during the research. In that effort the research team accomplished all proposed research, as well as many closely related research projects discovered and conceived of during the grant. These works included “Efficient Quantum Measurement Engines”, a work published in Physical Review Letters, giving a theory of quantum measurement-based engines, which uses quantum measurement as a resource. These engines are designed to efficiently convert energy from the stochastic quantum measurement process into useful work. Further publications include “Experimental Realization of a Quantum Dot Energy Harvester”, a joint theory and experimental work in collaboration with the group of Charles Smith in Cambridge, UK, as well as long time theoretical collaborators, Rafael Sánchez and Björn Sothmann. This work, featured as an Editor’s Suggestion in Physical Review Letters, realized an earlier theoretical proposal of ours, whereby two resonant tunneling quantum dots are connected to a central electronic cavity that is heated by a hot energy source. We also published “Superconducting Quantum Refrigerator: Breaking and Rejoining Cooper Pairs with Magnetic Field Cycles” a work done in collaboration with experimentalist Francesco Giazotto from ENS Pisa, Italy, which also resulted in a patent. This paper, published in Phys. Rev. Applied, advanced the concept of a cyclic fridge based on the normal/superconducting phase transition together with layered materials separated by tunnel junctions. We also completed the proposed research on a heat transistor, publishing “Thermal transistor and thermometer based on Coulomb-coupled conductors”, carried out as a collaboration between my group and theorists Splettstoesser (Lund U., Sweden), Sothmann (U. Duisburg-Essen, Germany), and Sánchez (U. Autónoma de Madrid, Spain). We carried out an analysis of a quantum coupled to a quantum point contact as a sensitive thermometer and heat transistor. We found the optimal statistical estimator for the temperature and compared it with experiments on the same type of devices. We also investigated autonomous quantum absorption refrigerators using quantum dots to cool by using a very hot thermal reservoir to drive heat between two other reservoirs. In the article “Quantifying the quantum heat contribution from a driven superconducting circuit”, we demonstrated that for a driven superconducting circuit, we showed heat flow provided by a hot source to the qubit can be switched on and off by varying external parameters, the frequency and the intensity of the driving. In the work “Stochastic thermodynamic cycles of a mesoscopic thermoelectric engine”, we reconsidered the autonomous thermoelectric heat engine in terms of underlying cycles. Rather than periodic behavior, the cycles were stochastic in nature. Nevertheless, by undertaking a graph theoretical analysis of the elementary transport processed, great quantitative and qualitative insight could be found. We also considered the quantum measurement process and showed that a quantum version of Maxwell’s demon could be related to the work extraction of a quantum system, closely related to arrow-of-time measures for quantum measurement, as described in our article “Thermodynamics of quantum measurement and Maxwell's demon's arrow of time”. This work was selected in Phys. Rev. A as an Editor’s Suggestion. A recent preprint titled “Cyclic Superconducting Quantum Refrigerators Using Guided Fluxon Propagation” accomplished an important piece of this grant: to propose a new kind of quantum refrigerator using the dynamics of fluxons in a type II superconductor. This invention envisioned a race-track type geometry where fluxons are confined. By applying a gradient of magnetic field together with electric current in a Corbino geometry, the circulating fluxons can actively cool a cold reservoir, realizing a new type of cyclic superconducting refrigerator. We also investigated the possibility of thermal control from different points of view. The application of quantum measurement to the system gives a new kind of control on the system of interest – we have pioneered this approach and shown that measurement can boost the thermal power of quantum engines as described in “Continuous measurement boosted adiabatic quantum thermal machines”. The ability to have heat flows on demand is an outstanding challenge, and we have provided new solutions to this problem in Thermal control across a chain of electronic nanocavities” for a chain of electron cavities using gating voltage control. The control methods using qubit/qubit coupling to create absorption fridges at their most fundamental level have also been developed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Developments on two lithium vapor-box linear test-stand experiments

The lithium vapor-box divertor is a possible fusion power exhaust solution.It uses condensation pumping to create a gradient of vapor density in a divertor slot; this should allow a stable detachment front without active feedback.As initial explorations of the concept, two test stands which take the form of three connected cylindrical stainless steel boxes are being developed: one without plasma at PPPL, to test models of lithium evaporation and flow; and one for the linear plasma device Magnum-PSI (at DIFFER in Eindhoven, The Netherlands) to test the ability of a lithium vapor cloud to induce volumetric detachment and redistribute the plasma power.The first experiment uses boxes with diameters of 6 cm, joined by apertures with diameters of 2.2 cm. Up to 1 g of Li is placed in one box, which is heated to up to 600 degrees C. The Li evaporates, then flows to and condenses in the two other, cooler boxes over several minutes. The quantity of Li transported is assessed by weighing the boxes before and after the heating cycle, and is compared to the quantity predicted to flow for the box at its measured temperature using a Direct Simulation Monte Carlo code, SPARTA. With good experimental conditions, the two values agree to within 15%.The experiment on Magnum-PSI is in the conceptual design stage.The design is assessed by simulations using the code B2.5-Eunomia.They show that when the hydrogen-ion plasma beam, with n_e = 4e20 per cubic meter, T_e = 1.5 eV, and r = 1 cm, is passed through a 16 cm long, 12 Pa, 625 degree C Li vapor cloud, the plasma heat flux and pressure on the target are significantly reduced compared to the case without Li.With the Li present, the plasma is cooled by excitation of Li neutrals followed by radiation until it volumetrically recombines, lowering the heat flux from 3.7 MW/m^2 to 0.13 MW/m^2, and the pressure is reduced by 93%, largely by collisions of hydrogen ions with neutral Li.

divertor↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NASA Redox cell stack shunt current, pumping power, and cell performance tradeoffs

The NASA Redox energy storage system is under active technology development. The hardware undergoing laboratory testing is either 310 sq. cm. or 929 sq. cm. (0.33 sq. ft. or 1.0 sq. ft. per cell active area with up to 40 individual cells connected to make up a modular cell stack. This size of hardware allows rather accurate projections to be made of the shunt power/pump power tradeoffs. The modeling studies that were completed on the system concept are reviewed along with the approach of mapping the performance of Redox cells over a wide range of flow rates and depths of discharge of the Redox solutions. Methods are outlined for estimating the pumping and shunt current losses for any type of cell and stack combination. These methods are applicable to a variety of pumping options that are present with Redox systems. The results show that a fully developed Redox system has acceptable parasitic losses when using a fixed flow rate adequate to meet the worst conditions of current density and depth of discharge. These losses are reduced by about 65 percent if variable flow schedules are used. The exact value of the overall parasitics will depend on the specific system requirements of current density, voltage limits, charge, discharge time, etc.

Hagedorn, N.↗