Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ablator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Structural and optical properties of nanoparticles formed by laser ablation of porous silicon in liquids: Perspectives in biophotonics

The paper discusses the possibility of manufacturing silicon nanoparticles, which are suitable for contrasting biological tissues imaged by optical coherence tomography, by femtosecond laser ablation of porous silicon in various liquids. The manufactured nanoparticles are characterised by average sizes of 87, 112, and 102 nm for cases of ablation in water, ethanol, and liquid nitrogen, respectively, as well as a relatively narrow size distribution, which provides additional advantages for subsequent delivery into biological tissues. Electrochemical etching, which results in the formation of layers of porous silicon, allows the yield of ablation products to be increased several-fold by lowering the ablation threshold, thereby increasing the light scattering efficiency of the prepared suspensions compared with the case of using crystalline silicon as targets. The possibility of obtaining high-contrast images of a biotissue phantom based on an agar gel with embedded nanoparticles is shown. The magnitude of the contrast depends on the liquid used for ablation and correlates with the values of the reduced scattering coefficient of the studied suspensions. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser ablation loading of a surface-electrode ion trap

We demonstrate loading of {sup 88}Sr{sup +} ions by laser ablation into a mm-scale surface-electrode ion trap. The laser used for ablation is a pulsed, frequency-tripled Nd:YAG with pulse energies of 1-10 mJ and durations of 4 ns. An additional laser is not required to photoionize the ablated material. The efficiency and lifetime of several candidate materials for the laser ablation target are characterized by measuring the trapped ion fluorescence signal for a number of consecutive loads. Additionally, laser ablation is used to load traps with a trap depth (40 meV) below where electron impact ionization loading is typically successful (> or approx. 500 meV)

74 ATOMIC AND MOLECULAR PHYSICS↗

CaF{sub 2} ablation plumes as a source of CaF molecules for harmonic generation

Generation of low-order harmonics (third and fifth) of the fundamental radiation of a Q-switched Nd:YAG laser (1064 nm, pulse 15 ns) was observed in a CaF{sub 2} laser ablation plume. The ablation process is triggered by a second Q-switched Nd:YAG laser operating at 532 or 266 nm. In the scheme employed, the fundamental laser beam propagates parallel to the target surface at controllable distance and temporal delay, allowing to the probing of different regions of the freely expanding plume. The intensity of the harmonics is shown to decrease rapidly as the distance to the target is increased, and for each distance, an optimum time delay between the ablating laser pulse and the fundamental beam is found. In situ diagnosis of the plume by optical emission spectroscopy and laser-induced fluorescence serves to correlate the observed harmonic behavior with the temporally and spatially resolved composition and velocity of flight of species in the plume. It is concluded that harmonics are selectively generated by CaF species through a two-photon resonantly enhanced sum-mixing process exploiting the (B {sup 2{Sigma}+}-X {sup 2{Sigma}+}, {Delta}{nu}=0) transition of the molecule in the region of 530 nm. In this work polar molecules have been shown to be the dominating species for harmonic generation in an ablation plume. Implications of these results for the generation of high harmonics in strongly polar molecules which can be aligned in the ablation plasma are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dynamics of femtosecond laser ablation studied with time-resolved x-ray absorption fine structure imaging

We studied the dynamics of the femtosecond laser ablation of aluminum in an energy range well above the ablation threshold with the ultrafast time-resolved x-ray-absorption fine structure imaging technique. Analyzing the spectral structures near the L absorption edge that appeared in one-dimensional images of soft-x-ray absorbance, we successfully identified doubly and singly charged ions, neutral atoms, liquid nanoparticles, and possible atomic clusters in the expanding ablation plume. We also clarified that the ejected particles depend strongly on the laser irradiation intensity. The spatiotemporal evolution of the ablation particles allows us to estimate the spatial distribution of atomic density and the ejection velocity of each type of particle. In particular, we discuss the temporal sequence of the particle ejection in the early stages of plume expansion. Our experimental results strongly support the idea that photomechanical fragmentation and vaporization are dominant mechanisms for the production of liquid nanoparticles and neutral atoms, respectively, in femtosecond laser ablation induced in an irradiation intensity range of 10{sup 14}-10{sup 15} W/cm{sup 2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Intercostal high intensity focused ultrasound for liver ablation: The influence of beam shaping on sonication efficacy and near-field risks

Purpose: One of the major issues in high intensity focused ultrasound ablation of abdominal lesions is obstruction of the ultrasound beam by the thoracic cage. Beam shaping strategies have been shown by several authors to increase focal point intensity while limiting rib exposure. However, as rib obstruction leaves only part of the aperture available for energy transmission, conserving total emitted acoustic power, the intensity in the near-field tissues inherently increases after beam shaping. Despite of effective rib sparing, those tissues are therefore subjected to increased risk of thermal damage. In this study, for a number of clinically representative intercostal sonication geometries, modeling clinically available hardware, the effect of beam shaping on both the exposure of the ribs and near-field to acoustic energy was evaluated and the implications for the volumetric ablation rate were addressed. Methods: A relationship between rib temperature rise and acoustic energy density was established by means of in vivo MR thermometry and simulations of the incident acoustic energy for the corresponding anatomies. This relationship was used for interpretation of rib exposure in subsequent numerical simulations in which rib spacing, focal point placement, and the focal point trajectory were varied. The time required to heat a targeted region to 65 °C was determined without and with the application of beam shaping. The required sonication time was used to calculate the acoustic energy density at the fat–muscle interface and at the surface of the ribs. At the fat–muscle interface, exposure was compared to available literature data and rib exposure was interpreted based on the earlier obtained relation between measured temperature rise and simulated acoustic energy density. To estimate the volumetric ablation rate, the cool-down time between periods of energy exposure was estimated using a time-averaged power limit of 100 kJ/h. Results: At the level of the ribs, the temperature rise–energy density proportionality constant was estimated to be 6.0–7.6 °C/(J/mm{sup 2}). Beam shaping by the geometric shadow method typically reduces the acoustic intensity a factor of 2, considering the 1 cm{sup 2} with the highest exposure. For a 4 mm diameter circular sonication trajectory, the near-field energy limit of 2.5 J/mm{sup 2} was exceeded for all considered geometries. The estimated rib temperature was in all but one (sonication 50 mm behind the ribs, with 15 mm rib spacing and a 4 mm diameter circular sonication trajectory) of the considered scenarios within acceptable limits. For those sonication scenarios where a single sonication is considered safe both in terms of near-field as well as rib heating, volumetric ablation rates in the order of 1 ml/h are estimated. Conclusions: Intercostal sonication is associated with an increased risk of near-field overheating. This risk is strongly dependent on the considered rib spacing, the placement of the focus behind the ribs, and the selected sonication trajectory. For the hardware under simulation, obstruction by the thoracic cage renders ablations of clinically relevant volumes within a practical time-frame unfeasible in a large part of the liver. Improvements maybe expected from transducer designs with a larger active surface and/or nonlinear sonication strategies.

60 APPLIED LIFE SCIENCES↗

Nickel plasma produced by 532-nm and 1064-nm pulsed laser ablation

A comparison between laser ablation of nickel in vacuum by using 532-and 1064-nm Nd:YAG (Yttrium Aluminium Garnet) laser wavelengths, with an intensity of 5 x 10{sup 9} W/cm{sup 2}, is reported. Nanosecond pulsed ablation produces high nonisotropic emission of neutrals and ionic species. For 532-nm laser irradiation, mass quadrupole spectrometry, coupled to electrostatic ion deflection and time-of-flight measurements, allows estimation of the energy distributions of the emitted species from plasma. For 1064-nm laser ablation, a cylindrical electrostatic ion analyzer permits one to measure the yield and the charge state of the emitted ions and reconstruct the ion energy and charge state distributions. Neutrals show typical Boltzmann-like distributions, while ions show Coulomb-Boltzmann-shifted distributions depending on their charge state. Surface profiles of the ablated craters permitted study of the ablation threshold and yields of nickel in vacuum versus the laser fluence. The plasma temperature was evaluated using experimental data. Special regard is given to the ion acceleration process occurring inside the plasma due to the high electrical field generated at nonequilibrium plasma conditions and the angular distribution of the emitted species.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Planarization of Isolated Defects on ICF Target Capsule Surfaces by Pulsed Laser Ablation

Demanding surface quality requirements for inertial confinement fusion (ICF) capsules motivated the development of a pulsed laser ablation method to reduce or eliminate undesirable surface defects. The pulsed laser ablation technique takes advantage of a full surface (4π) capsule manipulation system working in combination with an optical profiling (confocal) microscope. Based on the defect topography, the material removal rate, the laser pulse energy and its beam profile, a customized laser raster pattern is derived to remove the defect. The pattern is a table of coordinates and number of pulses that dictate how the defect will be vaporized until its height is level with the capsule surface. This paper explains how the raster patterns are optimized to minimize surface roughness and how surface roughness after laser ablation is simulated. The simulated surfaces are compared with actual ablated surfaces. Large defects are reduced to a size regime where a tumble finishing process produces very high quality surfaces devoid of high mode defects. The combined polishing processes of laser ablation and tumble finishing have become routine fabrication steps for National Ignition Facility capsule production.

36 MATERIALS SCIENCE↗

Real time assessment of RF cardiac tissue ablation with optical spectroscopy

An optical spectroscopy approach is demonstrated allowing for critical parameters during RF ablation of cardiac tissue to be evaluated in real time. The method is based on incorporating in a typical ablation catheter transmitting and receiving fibers that terminate at the tip of the catheter. By analyzing the spectral characteristics of the NIR diffusely reflected light, information is obtained on such parameters as, catheter-tissue proximity, lesion formation, depth of penetration of the lesion, formation of char during the ablation, formation of coagulum around the ablation site, differentiation of ablated from healthy tissue, and recognition of micro-bubble formation in the tissue.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental and Computational Studies of High Energy Density Plasma Streams Ablated from Fine Wires

This report summarizes progress during the final year of this project to study the physics of high energy density (HED) plasma streams of 10^17-10^20/cm3 density and high velocity (~100-500 km/s). Such streams are produced from 5-250 micrometer diameter wires heated and ionized by a 1 MA, 250 ns current pulse on the COBRA pulsed power facility at Cornell University. Plasma is ablated from the wires and is driven away to high velocity by unbalanced JxB force. A wire, or an array of wires, can persist as an essentially stationary, continuous source of this streaming plasma for >200 ns, even with driving magnetic fields of many Tesla and peak current densities in the plasma of many MA/cm2. At the heart of the ablation stream generation is the continuous transport of mass from the relatively cold, near-solid-density wire "core" into current-carrying plasma within 1 mm of the wire, followed by the magnetic acceleration of that plasma and its trapped flux to form a directed stream. In the first two years of this program, an advancing understanding of ablation physics led to the discovery of several novel wire ablation experimental regimes. In the final year, one of these new HED plasma regimes has been studied in quantitative detail. This regime studies highly reproducible magnetic reconnection in strongly radiating plasma with supersonic and superalfvenic flow, and shock structures in the outflow. The key discovery is that very heavy wires, e.g. 250 micrometer diameter Al or 150 micrometer Cu, behave in a qualitatively different way than the lighter wires typically used in wire-array Z-pinches. Such wires can be configured to produce a static magnetic X-point null geometry that stores magnetic and thermal energy; reconnection and outflow are triggered when the current begins to decrease and the electric field reverses. The reconnecting flow is driven by both magnetic and thermal pressure forces, and it has been found to be possible to vary the configuration so that one or the other dominates. The magnetic null extends into a current sheet that is heated and radiates strongly, with supersonic outflows. This is the first study of reconnection in this HED plasma regime. This compressible, radiative regime, and the triggering mechanism, may be relevant to solar and astrophysical processes. The PERSEUS extended MHD code has been developed for simulation of these phenomena, and will continue to be used and further developed to help interpret and understand experimental results, as well as to guide experimental design. The code is well-suited to simulations of shocks, and includes Hall and electron inertia physics that appear to be of importance in a number of ablation flow regimes, and definitely in the reconnection regime when gradient scales are comparable to the ion inertial scale. During the final year, our graduate student supported by this grant completed a new version of PERSEUS with the finite volume computational scheme replaced by a discontinuous Galerkin method that gives much less diffusive behavior and allows faster run time and higher spatial resolution. The code is now being used to study shock structures produced in the outflow region of the reconnection regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray Micro-Tomography of Ablative Heat Shield Materials

X-ray micro-tomography is a non-destructive characterization technique that allows imaging of materials structures with voxel sizes in the micrometer range. This level of resolution makes the technique very attractive for imaging porous ablators used in hypersonic entry systems. Besides providing a high fidelity description of the material architecture, micro-tomography enables computations of bulk material properties and simulations of micro-scale phenomena. This presentation provides an overview of a collaborative effort between NASA Ames Research Center and Lawrence Berkeley National Laboratory, aimed at developing micro-tomography experiments and simulations for porous ablative materials. Measurements are carried using x-rays from the Advanced Light Source at Berkeley Lab on different classes of ablative materials used in NASA entry systems. Challenges, strengths and limitations of the technique for imaging materials such as lightweight carbon-phenolic systems and woven textiles are discussed. Computational tools developed to perform numerical simulations based on micro-tomography are described. These enable computations of material properties such as permeability, thermal and radiative conductivity, tortuosity and other parameters that are used in ablator response models. Finally, we present the design of environmental cells that enable imaging materials under simulated operational conditions, such as high temperature, mechanical loads and oxidizing atmospheres.Keywords: Micro-tomography, Porous media, Ablation

tomography↗

Multi-Dimensional, Non-Pyrolyzing Ablation Test Problems

Non-pyrolyzingcarbonaceous materials represent a class of candidate material for hypersonic vehicle components providing both structural and thermal protection system capabilities. Two problems relevant to this technology are presented. The first considers the one-dimensional ablation of a carbon material subject to convective heating. The second considers two-dimensional conduction in a rectangular block subject to radiative heating. Surface thermochemistry for both problems includes finite-rate surface kinetics at low temperatures, diffusion limited ablation at intermediate temperatures, and vaporization at high temperatures. The first problem requires the solution of both the steady-state thermal profile with respect to the ablating surface and the transient thermal history for a one-dimensional ablating planar slab with temperature-dependent material properties. The slab front face is convectively heated and also reradiates to a room temperature environment. The back face is adiabatic. The steady-state temperature profile and steady-state mass loss rate should be predicted. Time-dependent front and back face temperature, surface recession and recession rate along with the final temperature profile should be predicted for the time-dependent solution. The second problem requires the solution for the transient temperature history for an ablating, two-dimensional rectangular solid with anisotropic, temperature-dependent thermal properties. The front face is radiatively heated, convectively cooled, and also reradiates to a room temperature environment. The back face and sidewalls are adiabatic. The solution should include the following 9 items: final surface recession profile, time-dependent temperature history of both the front face and back face at both the centerline and sidewall, as well as the time-dependent surface recession and recession rate on the front face at both the centerline and sidewall. The results of the problems from all submitters will be collected, summarized, and presented at a later conference.

Ablation↗

In-situ Nanoscale Ablation

An understanding of the ablation of carbon-based materials is crucial to modeling the behavior of atmospheric entry spacecrafts equipped with thermal protection systems (TPS).Carbon is the backbone of TPS systems such as PICA (phenolic-impregnated carbon ablator).Therefore in the present work we study ablation of highly oriented pyrolytic graphite (HOPG)in oxygen at temperatures up to 1000°C done within a gas reaction cell housed in a scanning transmission electron microscope (STEM). Observation of the HOPG oxidation on specimens sectioned parallel and normal to the carbon basal planes in the presence of oxygen are reported.Pitting caused by residual oxygen and/or platinum particles from the sectioning process was observed before oxygen gas flow was established at 750°C in the specimen sectioned with the carbon basal planes parallel to the beam direction. Introduction of oxygen flow caused rapid oxidation moving in a uniform front that completely consumed the HOPG in approximately 1.5minutes. The specimen sectioned with the carbon basal planes normal to the beam direction did not show the same pitting phenomenon but exhibited rapid oxidation at 1000°C that proceeded in a uniform front and completed in approximately 1 minute. All specimens tested had a husk resembling the original specimen shape left over after oxidation. It is concluded that this husk is most likely ash impurity from the HOPG or impurities from the sectioning process or E-chip. A residual gas analyszer (RGA) was successfully used to monitor gas flows during the experiments but was yet unsuccessful in monitoring oxidation gas products produced during the experiment.Future studies will optimize the RGA setup in order to maximize the potential for detecting these species. These in-situ studies successfully show how this highly ordered carbon ablates on a nano- and micro-scopic length scale and can be used to provide fundamental understanding of carbon ablation that can be used to design the next-generation of TPS systems.

Nanoscale Ablation↗

Design calculations for NIF convergent ablator experiments.

Design calculations for NIF convergent ablator experiments will be described. The convergent ablator experiments measure the implosion trajectory, velocity, and ablation rate of an x-ray driven capsule and are a important component of the U. S. National Ignition Campaign at NIF. The design calculations are post-processed to provide simulations of the key diagnostics: (1) Dante measurements of hohlraum x-ray flux and spectrum, (2) streaked radiographs of the imploding ablator shell, (3) wedge range filter measurements of D-He3 proton output spectra, and (4) GXD measurements of the imploded core. The simulated diagnostics will be compared to the experimental measurements to provide an assessment of the accuracy of the design code predictions of hohlraum radiation temperature, capsule ablation rate, implosion velocity, shock flash areal density, and x-ray bang time. Post-shot versions of the design calculations are used to enhance the understanding of the experimental measurements and will assist in choosing parameters for subsequent shots and the path towards optimal ignition capsule tuning.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the Properties of Plastic Ablators in Laser-Driven Material Dynamics Experiments

Radiation hydrodynamics simulations were used to study the effect of plastic ablators in laser-driven shock experiments. The sensitivity to composition and equation of state was found to be 5-10% in ablation pressure. As was found for metals, a laser pulse of constant irradiance gave a pressure history which decreased by several percent per nanosecond. The pressure history could be made more constant by adjusting the irradiance history. The impedance mismatch with the sample gave an increase o(100%) in the pressure transmitted into the sample, for a reduction of several tens of percent in the duration of the peak load applied to the sample, and structured the release history by adding a release step to a pressure close to the ablation pressure. Algebraic relations were found between the laser pulse duration, the ablator thickness, and the duration of the peak pressure applied to the sample, involving quantities calculated from the equations of state of the ablator and sample using shock dynamics.

36 MATERIALS SCIENCE↗

Investigation Into the Optimum Beam Shape and Fluence for Selective Ablation of Dental Calculus at lambda = 400 nm

A frequency-doubled Ti:sapphire laser is shown to selectively ablate dental calculus. The optimal transverse shape of the laser beam, including its variability under water-cooling, is determined for selective ablation of dental calculus. Intensity profiles under various water-cooling conditions were optically observed. The 400-nm laser was coupled into a multimode optical fiber using an f = 2.5-cm lens and light-shaping diffuser. Water-cooling was supplied coaxially around the fiber. Five human tooth samples (four with calculus and one pristine) were irradiated perpendicular to the tooth surface while the tooth was moved back and forth at 0.3 mm/second, varying between 20 and 180 iterations. The teeth were imaged before and after irradiation using light microscopy with a flashing blue light-emitting diode (LED). An environmental scanning electron microscope imaged each tooth after irradiation. High-order super-Gaussian intensity profiles are observed at the output of a fiber coiled around a 4-in. diameter drum. Super-Gaussian beams have a morehomogenous fluence distribution than Gaussian beams and have a higher energy efficiency for selective ablation. Coaxial water-cooling does not noticeably distort the intensity distribution within 1 mm from the optical fiber. In contrast, lasers focused to a Gaussian cross section (<=50-mm diameter) without fiber propagation and cooled by a water spray are heavily distorted and may lead to variable ablation. Calculus is preferentially ablated at high fluences (>= 2 J/cm^2); below this fluence, stalling occurs because of photo-bleaching of the calculus. Healthy dental hard tissue is not removed at fluences <=3 J/cm^2. Supplying laser light to a tooth using an optical fiber with coaxial water-cooling is determined to be the most appropriate method when selectively removing calculus with a frequency-doubled Ti:sapphire laser. Fluences over 2 J/cm^2 are required to remove calculus efficiently since photo-bleaching stalls calculus removal below that value.

calculus removal↗

CuInGaSe{sub 2} nanoparticles by pulsed laser ablation in liquid medium

Highlights: • CIGS nanocolloids were synthesized using PLAL technique. • Characterized their morphology, structure, composition and optical properties. • Morphologies were dependent on ablation wavelength and liquid medium. • Optical absorption and bandgap of these nanocolloids were tunable. - Abstract: Pulsed laser ablation in liquid medium (PLALM) is a nanofabrication technique to produce complex nanostructures. CuInGaSe{sub 2} (CIGS) is an alloy with applications in photovoltaic industry. In this work, we studied the effects of laser ablation wavelength, energy fluence and liquid medium on the properties of the CIGS nanoparticles synthesized by PLALM. The nanoparticles obtained were analyzed by transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy (EDX), selected area electron diffraction (SAED), X-ray photoelectron spectroscopy (XPS) and UV–vis absorption spectroscopy. XPS results confirmed the chemical states and composition of the ablated products. TEM analysis showed different morphologies for the nanomaterials obtained in different liquid media and ablation wavelengths. The optical properties for these CIGS nanocolloids were analyzed using UV–vis absorption spectroscopy. The results demonstrated the use of PLALM as a useful synthesis technique for nanoparticles of quaternary photovoltaic materials.

36 MATERIALS SCIENCE↗

Comparison of atomized mass and crater volume in laser ablation

The extent and dynamics of laser ablation are typically studied using crater imaging or by invoking the relationship between atomic emission and the mass removed. The former is a static view of a dynamic process and requires the accumulation of multiple shots in one location. The latter is complex and not absolute without calibration of the optical system with a standard of spectral radiance. We measure the mass of the atomized plume by laser atomic-absorption spectroscopy at 2 µs without external mass calibration; mass uncertainty in laser-ablation atomic absorption spectroscopy (LA-AAS) results from uncertainties in line area fitting, tabulated oscillator strengths, and partition functions as well as a <10% underrepresentation of the mass due to treating the plasma as a single thermodynamic equilibrium. The LA-AAS-measured mass pertains to the atoms in the probed charge states and does not include condensed or molecular species. The ablation efficiency at 300 mbar of helium varies significantly between the two focusing conditions used. A comparison of crater-derived masses and LA-AAS masses suggests that more defocused ablation may result in significant redeposition of material in the crater, distorting the conclusions from drilling studies and crater imaging. More focused ablation conditions result in crater-derived masses that exceed those measured with LA-AAS and suggest melt expulsion or phase explosion.

Merten, Jonathan [Arkansas State University, Jones↗

Experimental and computational investigation into the hydrodynamics and chemical dynamics of laser ablation aluminum plasmas

Laser ablation plasma chemistry is governed by a complex interplay between hydrodynamic plasma-gas mixing processes, thermodynamics, and rapid high-temperature chemical reactions. Here, in this work, we investigate the gas-phase oxidation chemistry of ns-laser ablation aluminum plasmas in air using optical spectroscopy combined with advanced multi-physics modeling. Experimental measurements demonstrate the formation of AlO in the plasma plume as early as 1 μs while computational results reveal that several Al x O y species are distributed in the periphery of the plume at even earlier times (<20 ns) in the presence of large temperature gradients and strong shockwaves. Interactions with the ablation crater during rapid plume expansion are shown to initiate vortex formation, followed by mixing dynamics that work to pull AlO into the vortices to react with gas-phase Al to form Al 2 O. Oxygen and several aluminum oxides are simultaneously pulled up through the stem of the fireball, encouraging further intermixing between reacting species and enhanced molecular formation. This work concludes that chemical dynamics in laser ablation plasmas is driven by diffusion processes, concentration gradients, and plume hydrodynamics while strong shockwaves generated during laser ablation do not impede chemical reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗