Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AUGER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Theoretical prediction of the impact of Auger recombination on charge collection from an ion track

The theoretical analysis presented indicates that Auger recombination can reduce charge collection from very dense ion tracks in silicon devices. It is of marginal importance for tracks produced by 270-MeV krypton, and therefore it is of major importance for ions exhibiting a significantly larger loss. The analysis shows that recombination loss is profoundly affected by track diffusion. As the track diffuses, the density and recombination rate decrease so fast that the linear density (number of electron-hole pairs per unit length) approaches a nonzero limiting value as t approaches infinity. Furthermore, the linear density is very nearly equal to this limiting value in a few picoseconds or less. When Auger recombination accompanies charge transport processes that have much longer time scales, it can be simulated by assigning a reduced linear energy transfer to the ion.

Edmonds, Larry D.↗

Relativistic Radiative and Auger Rates for Fe XXIV

As part of a project to compute improved atomic data for the spectral modeling of iron K lines, we report extensive calculations and comparisons of radiative and Auger rates for transitions involving the K-vacancy states in Fe XXIV. By making use of several computational codes, a detailed study is carried out of orbital representation, configuration interaction, relativistic corrections, cancellation effects, and fine tuning. It is shown that a formal treatment of the Breit interaction is essential to render the important magnetic correlations that take part in the decay pathways of this ion. As a result, the accuracy of the present A-values is firmly ranked at better than 10% while that of the Auger rates at only 15%.

Bautista, M. A.↗

Modeling of Iron K Lines: Radiative and Auger Decay Data for Fe II-Fe IX

A detailed analysis of the radiative and Auger de-excitation channels of K-shell vacancy states in Fe II-Fe IX has been carried out. Level energies, wavelengths, A-values, Auger rates and fluorescence yields have been calculated for the lowest fine-structure levels populated by photoionization of the ground state of the parent ion. Different branching ratios, namely K alpha 2/K alpha 1, K beta/K alpha, KLM/KLL, KMM/KLL, and the total K-shell fluorescence yields, omega(sub k), obtained in the present work have been compared with other theoretical data and solid-state measurements, finding good general agreement with the latter. The Kalpha 2/K alpha l ratio is found to be sensitive to the excitation mechanism. From these comparisons it has been possible to estimate an accuracy of approx.10% for the present transition probabilities.

Palmeri, P.↗

ATHLETE : Double Auger Anchoring Mechanism

The All-Terrain Hex-Legged Extra-Terrestrial Explorer (ATHLETE) is a six-limbed robot designed to support surface explorations on Near Earth Objects, the Moon and Mars. ATHLETE can carry large payloads on its top deck and can carry a fully equipped pressurized habitat in low gravity. The robot has wheels on each of its six articulated limbs, allowing it to actively conform to terrain while driving and to walk when driving is impractical. With the use of a tool adapter, ATHLETE limbs can be equipped with end effectors to support various mission objectives. For work on Near Earth Objects and other microgravity environments, an anchoring mechanism is needed to keep the ATHLETE from floating off the surface. My goal for this spring session at JPL was to design and build a counter rotating, double auger, anchoring mechanism. The mechanism mates to the tool adapter and is driven off the wheel motor. The double auger anchoring mechanism will be tested in a regolith simulant that will determine the uplift capacity of the anchoring mechanism.

Human-Robot Systems (HRS) Project↗

Experiences with the High Energy Resolution Optics (HERO) update on a physical electronics 690 auger system.

We will present our experiences with the new High Energy Resolution Optics (HERO) upgrade on a Physical Electronics Auger 690 system. This upgrade allows the single pass cylindrical analyzer in the Auger system to achieve higher energy resolution than in the standard mode. With this upgrade, it should be possible to separate chemical states for certain elements. Also, it should be possible to separate closely spaced peaks from selected elements that have been difficult or impossible to separate without the upgrade. Specifically, we will investigate practical use of this upgrade in the analysis of materials systems where overlapping peaks have historically been an issue, such as Kovar, which consists of the elements Ni, Fe and Co. Strategies for the successful use of the technique as well as its current limitations will be shown.

36 MATERIALS SCIENCE↗

Thermal swing reactor including a multi-flight auger

A thermal swing reactor including a multi-flight auger and methods for solar thermochemical reactions are disclosed. The reactor includes a multi-flight auger having different helix portions having different pitch. Embodiments of reactors include at least two distinct reactor portions between which there is at least a pressure differential. In embodiments, reactive particles are exchanged between portions during a reaction cycle to thermally reduce the particles at first conditions and oxidize the particles at second conditions to produce chemical work from heat.

14 SOLAR ENERGY↗

Search for Ultra-High Energy Photons with the Pierre Auger Observatory

One of key scientific objectives of the Pierre Auger Observatory is the search for ultra-high energy photons. Such photons could originate either in the interactions of energetic cosmic-ray nuclei with the cosmic microwave background (so-called cosmogenic photons) or in the exotic scenarios, e.g. those assuming a production and decay of some hypothetical super-massive particles. The latter category of models would imply relatively large fluxes of photons with ultra-high energies at Earth, while the former, involving interactions of cosmic-ray nuclei with the microwave background - just the contrary: very small fractions. The investigations on the data collected so far in the Pierre Auger Observatory led to placing very stringent limits to ultra-high energy photon fluxes: below the predictions of the most of the exotic models and nearing the predicted fluxes of the cosmogenic photons. In this paper the status of these investigations and perspectives for further studies are summarized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal swing reactor including a multi-flight auger

A thermal swing reactor including a multi-flight auger and methods for solar thermochemical reactions are disclosed. The reactor includes a multi-flight auger having different helix portions having different pitch. Embodiments of reactors include at least two distinct reactor portions between which there is at least a pressure differential. In embodiments, reactive particles are exchanged between portions during a reaction cycle to thermally reduce the particles at first conditions and oxidize the particles at second conditions to produce chemical work from heat.

14 SOLAR ENERGY↗

Carrier confinement and alloy disorder exacerbate Auger–Meitner recombination in AlGaN ultraviolet light-emitting diodes

The quantum efficiency of AlGaN ultraviolet light-emitting diodes declines (droops) at increasing operating powers due to Auger–Meitner recombination (AMR). Using first-principles density-functional theory, we show that indirect AMR mediated by electron–phonon coupling and alloy disorder can induce bulk C coefficients as large as ~10 –31 cm 6 /s. Furthermore, we find that the confinement of carriers by polarization fields within quantum wells severely relaxes crystal-momentum conservation, which exacerbates the rate of AMR over radiative recombination by an order of magnitude relative to the bulk. Furthermore, this results in a striking decrease in quantum efficiency at high power. Suppressing polarization fields and jointly increasing the well width would greatly mitigate AMR and efficiency droop.

36 MATERIALS SCIENCE↗

Energy Spectrum of Ultrahigh-Energy Cosmic Rays across Declinations -90° to +44.8° as Measured at the Pierre Auger Observatory

The energy spectrum of cosmic rays above 2.5 EeV has been measured across the declination range - 9 0 ° ≤ δ ≤ + 44.8 ° using ∼ 310 000 events accrued at the Pierre Auger Observatory from an exposure of ( 104 900 ± 3 100 ) km 2 sr yr . No significant variations of energy spectra with declination are observed, after allowing or not for nonuniformities across the sky arising from the well-established dipolar anisotropies in the arrival directions of ultrahigh-energy cosmic rays. Here, the instep feature in the spectrum at ≃ 10 EeV reported previously is now established at a significance above 5 σ . Within the statistics, the energy spectra are indistinguishable across declinations so disfavoring an origin for the instep from a few distinctive sources.

Abdul Halim, A. [University of Adelaide]↗

Towards the Stable Chelation of Radioantimony(V) for Targeted Auger Theranostics

Antimony-119 ( 119 Sb) is one of the most attractive Auger-electron emitters identified to date, but it remains practically unexplored for targeted radiotherapy because no chelators have been identified to stably bind this metalloid in vivo. In a departure from current studies focused on chelator development for Sb(III), we explore the chelation chemistry of Sb(V) using the tris-catecholate ligand TREN-CAM. Through a combination of radiolabeling, spectroscopic, solid-state, and computational studies, the radiochemistry and structural chemistry of TREN-CAM with 1XX/nat Sb(V) were established. The resulting [ 1XX Sb]Sb–TREN-CAM complex remained intact for several days in human serum, signifying high stability under biological conditions. Finally, the first in vivo single photon emission computed tomography and positron emission tomography imaging studies were carried out using 117 Sb, the diagnostic analogue of 119 Sb. These studies revealed marked differences in the uptake and distribution of activity in mice administered unchelated [ 117 Sb]Sb(OH) 6 – versus [ 117 Sb]Sb–TREN-CAM, suggesting that 117 Sb is largely retained by TREN-CAM over the time course of the study. Collectively, these findings demonstrate the most physiologically stable complex of no-carrier-added 1XX Sb yet reported, offering new promise for the clinical implementation of radioantimony in nuclear medicine. In conclusion, our results also establish the feasibility of 117 Sb as an elementally matched partner to 119 Sb for theranostic applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Highlights from the Pierre Auger Observatory

The Pierre Auger Observatory is the world’s largest cosmic ray observatory. Our current exposure reaches nearly 40,000 km 2 sr and provides us with an unprecedented quality data set. In this highlight, the performance and stability of the detectors and their enhancements are described. Data analyses have led to a number of major breakthroughs. Among these, we discuss the energy spectrum and the searches for large-scale anisotropies. We present analyses of our X max data and show how it can be interpreted in terms of mass composition. We also describe some new analyses that extract mass-sensitive parameters from the 100 % duty cycle surface detector (SD) data. A coherent interpretation of all these recent results opens new directions. The consequences regarding the cosmic ray composition and the properties of ultrahigh-energy cosmic ray (UHECR) sources are briefly discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of passivated A-286 stainless steel surfaces for mass spectrometer inlet systems by Auger electron and X-ray photoelectron spectroscopy and scanning electron microscopy

In this study, various commercially available surface treatments are being explored for use on stainless steel components in mass spectrometer inlet systems. Type A-286 stainless steel coupons, approximately 12.5 mm in diameter and 3 mm thick, were passivated with one of five different surface treatments; an untreated coupon served as a control. The surface and near-surface microstructure and chemistry of the coupons were investigated using sputter depth profiling using Auger electron spectroscopy, x-ray photoelectron spectroscopy, and scanning electron microscopy (SEM). All the surface treatments studied appeared to change the surface morphology dramatically, as evidenced by lack of tool marks on the treated samples in SEM images. In terms of the passivation treatment, Vendors A-D appeared to have oxide layers that were very similar in thickness to each other (0.7–0.9 nm thick), as well as to the untreated samples (the untreated sample oxide layers appeared to be somewhat larger). Vendor E’s silicon coating appears to be on the order of 200 nm thick.

36 MATERIALS SCIENCE↗

Spectral calibration of the fluorescence telescopes of the Pierre Auger Observatory

We present a novel method to measure precisely the relative spectral response of the fluorescence telescopes of the Pierre Auger Observatory. Here, we used a portable light source based on a xenon flasher and a monochromator to measure the relative spectral efficiencies of eight telescopes in steps of 5 nm from 280 nm to 440 nm. Each point in a scan had approximately 2 nm FWHM out of the monochromator. Different sets of telescopes in the observatory have different optical components, and the eight telescopes measured represent two each of the four combinations of components represented in the observatory. We made an end-to-end measurement of the response from different combinations of optical components, and the monochromator setup allowed for more precise and complete measurements than our previous multi-wavelength calibrations. We find an overall uncertainty in the calibration of the spectral response of most of the telescopes of 1.5% for all wavelengths; the six oldest telescopes have larger overall uncertainties of about 2.2%. We also report changes in physics measureables due to the change in calibration, which are generally small.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Approaches to analyzing insulators with Auger Electron Spectroscopy: Update and Overview

This paper provides an updated overview, intended to be of practical value to analysts, of methods that can be applied to minimize or control the buildup of near surface electrical charge during electron induced Auger electron spectroscopy (AES). Although well developed methods can be highly effective, dealing with insulating or ungrounded samples for which high spatial resolution is needed remains a challenge. Examples of the application of methods involving low energy ion sources and sample thinning using a focused ion beam that can allow high resolution measurements on a variety of samples are highlighted. The physical bases of newer and traditional methods are simply described along with strengths and limitations of the methods. Summary tables indicate which methods apply to almost any spectrometer, which require special instrumental capabilities, and those that require special sample preparation or mounting.

36 MATERIALS SCIENCE↗

An Auger electron spectroscopy study of phosphorus and molybdenum grain boundary segregation in a 2.25Cr1Mo steel

Thermodynamics of grain boundary segregation of phosphorus and molybdenum in a 2.25Cr1Mo steel were investigated using Auger electron spectroscopy (AES). After quenching from 980 deg. C and tempering at 650 deg. C, the steel samples were aged for different times at 560 deg. C, 520 deg. C and 480 deg. C, respectively, followed by AES measurements. Based on the AES results for equilibrium grain boundary concentrations of phosphorus and molybdenum, it is seen that the interaction between these two elements in segregation is weak and the free energies of segregation are constant, being about 38 kJ/mol and 17 kJ/mol for phosphorus and molybdenum, respectively.

36 MATERIALS SCIENCE↗

Simulation of Auger electron emission from nanometer-size gold targets using the Geant4 Monte Carlo simulation toolkit

We report that a revised atomic deexcitation framework for the Geant4 general purpose Monte Carlo toolkit capable of simulating full Auger deexcitation cascades was implemented in June 2015 release (version 10.2 Beta). An overview of this refined framework and testing of its capabilities is presented for the irradiation of gold nanoparticles (NP) with keV photon and MeV proton beams. The resultant energy spectra of secondary particles created within and that escape the NP are analyzed and discussed. It is anticipated that this new functionality will improve and increase the use of Geant4 in the medical physics, radiobiology, nanomedicine research and other low energy physics fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preclinical studies of a PARP targeted, Meitner-Auger emitting, theranostic radiopharmaceutical for metastatic ovarian cancer

Advanced ovarian cancer currently has few therapeutic options. Poly(ADP-ribose) polymerase (PARP) inhibitors bind to nuclear PARP and trap the protein-inhibitor complex to DNA. This work investigates a theranostic PARP inhibitor for targeted radiopharmaceutical therapy of ovarian cancer in vitro and PET imaging of healthy mice in vivo. Methods: [ 77 Br]RD1 was synthesized and assessed for pharmacokinetics and cytotoxicity in human and murine ovarian cancer cell lines. [ 76 Br]RD1 biodistribution and organ uptake in healthy mice were quantified through longitudinal PET/CT imaging and ex vivo radioactivity measurements. Organ-level dosimetry following [ 76/77 Br]RD1 administration was calculated using RAPID, an in-house platform for absorbed dose in mice, and OLINDA for equivalent and effective dose in human. Results: The maximum specific binding (B max ), equilibrium dissociation constant (K d ), and nonspecific binding slope (NS) were calculated for each cell line. These values were used to calculate the cell specific activity uptake for cell viability studies. The half maximal effective concentration (EC 50 ) was measured as 0.17 (95 % CI: 0.13–0.24) nM and 0.46 (0.13–0.24) nM for PARP(+) and PARP(–) expressing cell lines, respectively. The EC 50 was 0.27 (0.21–0.36) nM and 0.30 (0.22–0.41) nM for BRCA1(–) and BRCA1(+) expressing cell lines, respectively. When measuring the EC 50 as a function of cellular activity uptake and nuclear dose, the EC 50 ranges from 0.020 to 0.039 Bq/cell and 3.3–9.2 Gy, respectively. Excretion through the hepatobiliary and renal pathways were observed in mice, with liver uptake of 2.3 ± 0.4 %ID/g after 48 h, contributing to estimated absorbed dose values in mice of 19.3 ± 0.3 mGy/MBq and 290 ± 10 mGy/MBq for [ 77 Br]RD1 and [ 76 Br]RD1, respectively. Conclusion: [ 77 Br]RD1 cytotoxicity was dependent on PARP expression and independent of BRCA1 status. Finally, the in vitro results suggest that [ 77 Br]RD1 cytotoxicity is driven by the targeted Meitner-Auger electron (MAe) radiotherapeutic effect of the agent. Further studies investigating the theranostic potential, organ dose, and tumor uptake of [ 76/77 Br]RD1 are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗