Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AMPLIFIER DESIGN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

The Use of a Solid State Analog Television Transmitter as a Superconducting Electron Gun Power Amplifier

A solid state analog television transmitter designed for 200 MHz operation is being commissioned as a radio frequency power amplifier on the Wisconsin superconducting electron gun cavity. The amplifier consists of three separate radio frequency power combiner cabinets and one monitor and control cabinet. The transmitter employs rugged field effect transistors built into one kilowatt drawers that are individually hot swappable at maximum continuous power output. The total combined power of the transmitter system is 33 kW at 200 MHz, output through a standard coaxial transmission line. A low level radio frequency system is employed to digitally synthesize the 200 MHz signal and precisely control amplitude and phase.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization and calibration of compact array spectrometers in the ultraviolet spectral region

Array-based spectrometers, with their compact size, low weight, low cost, and fast measurement time, are now frequently used in place of both conventional single-channel scanning monochromators, and broadband meters. Their rapid measurement capability makes them an attractive option for routine solar UV spectral measurements, where shortterm variability in signal is a challenge. However, compactness, portability, low cost and high speed are achieved at the expense of the spectrometer's optical and electronic performance. Thus such spectrometers are more prone to measurement error from environmental changes, and more prone to other intrinsic sources of error such as stray light and detector non-linearity, which significantly affect solar UV measurements, than a scanning monochromator. The effects of stray light and non-linearity can be reduced either by improved optical and detector design or by a detailed spectrometer characterization. We present in this paper our investigation of the performance of three different commercial array spectrometers: two mini-spectrometers, and a more elaborate array spectrometer with an on-board image amplifier device. These were tested for a subset of performance parameters: their wavelength accuracy and stability, electronic linearity, responsivity linearity, stray light sensitivity, and mechanical stability and repeatability. With all three spectrometers we found that these parameters, particularly but not limited to stray light, had a significant impact on the measurement of the incoming optical radiation. This meant that, without characterization, the instruments would be unable to accurately measure the UV component of any source with significant visible radiation. We discuss various simple and low-cost solutions for improving the performance of these instruments, and providing a rigorous calibration using a straightforward set-up including optical filters and the quasi-monochromatic light from a double monochromator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A design of Si-based nanoplasmonic structure as an antenna and reception amplifier for visible light communication

Visible light communication has been widely investigated due to its larger bandwidth and higher bit rate, and it can combine with the indoor illumination system that makes it more convenient to carry out. Receiving and processing the visible light signal on chip request for nanophotonics devices performing well. However, conventional optical device cannot be used for light-on-chip integration at subwavelength dimensions due to the diffraction limit. Herein, we propose a design of Si-based nanoplasmonic structure as an antenna and reception amplifier for visible light communication based on the interaction between Si nanoparticle and Au nanorod. This device integrates the unique scattering property of high-refractive index dielectric Si nanoparticles, whose scattering spectrum is dependent on the particle size, with the localized surface plasmon resonance of Au nanorod. We calculated the spectra collected by plane detector and near field distribution of nanostructure, and theoretically demonstrate that the proposed device can act as good receiver, amplifier and superlens during the visible light signal receiving and processing. Besides, unlike some other designs of nanoantenna devices focused less on how to detect the signals, our hybrid nanoantenna can realize the transfer between the scattering source and the detector effectively by Au nanorod waveguides. These findings suggest that the designed nanoplasmonic structure is expected to be used in on-chip nanophotonics as antenna, spectral splitter and demultiplexer for visible light communication.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cryogenic Low Noise MMIC Amplifiers for U-Band (40-60 GHz)

In this work, we describe monolithic millimeter-wave integrated circuit (MMIC) Low Noise Amplifier (LNA) and mixer designs for U-Band, also known as the WR19 waveguide band (40-60 GHz). The LNAs were fabricated in NGC’s 35 nm InP HEMT MMIC process. The MMICs were packaged in WR19 waveguide housings and tested for noise, both at room temperature and cryogenically. We present the results, including a comparison to the state-of-the-art, and discuss applications for amplifiers in this frequency range. To date, these are the first cryogenic 35 nm InP MMIC results covering the 40-60 GHz range. We achieved a noise temperature less than 30 K over the 40-60 GHz range, when the amplifiers were cryogenically cooled. These results are comparable with other results in the literature, and we believe are the lowest reported for MMICs in the 50-60 GHz range.

MMIC↗

Solid state Ku-band spacecraft transmitters

A transmitter is considered that consists of GaAs IMPATT and Read diodes operating in a microstrip circuit environment to provide amplification with a minimum of 63 db small signal gain and a minimum compressed gain at 5 W output of 57 db. Reported are Schottky-Read diode design and fabrication, microstrip and circulator optimization, preamplifier development, power amplifier development, dc-to-dc converter design, and integration of the breadboard transmitter modules. A four-stage power amplifier in cascade with a three-stage preamplifier had an overall gain of 56.5 db at 13.5 GHz with a power output of 4.5 W. A single-stage Read amplifier delivered 5.9 W with 4 db gain at 22% efficiency.

Wisseman, W. R.↗

High-Efficiency Klystron For Television Transmitters

Improved klystron designed for use as final amplifier in ultrahigh-frequency (UHF) television transmitter. New device incorporates multistage depressed collector (MSDC) of advanced design to increase efficiency by recovering, from spent electron beam, some of residual kinetic energy otherwise dissipated as heat. Concept applied to increase efficiencies of microwave communication, equipment, radar systems, and particle-beam accelerators.

Ramins, Peter↗

Evidence Report, Risk of Inadequate Design of Human and Automation/Robotic Integration

The success of future exploration missions depends, even more than today, on effective integration of humans and technology (automation and robotics). This will not emerge by chance, but by design. Both crew and ground personnel will need to do more demanding tasks in more difficult conditions, amplifying the costs of poor design and the benefits of good design. This report has looked at the importance of good design and the risks from poor design from several perspectives: 1) If the relevant functions needed for a mission are not identified, then designs of technology and its use by humans are unlikely to be effective: critical functions will be missing and irrelevant functions will mislead or drain attention. 2) If functions are not distributed effectively among the (multiple) participating humans and automation/robotic systems, later design choices can do little to repair this: additional unnecessary coordination work may be introduced, workload may be redistributed to create problems, limited human attentional resources may be wasted, and the capabilities of both humans and technology underused. 3) If the design does not promote accurate understanding of the capabilities of the technology, the operators will not use the technology effectively: the system may be switched off in conditions where it would be effective, or used for tasks or in contexts where its effectiveness may be very limited. 4) If an ineffective interaction design is implemented and put into use, a wide range of problems can ensue. Many involve lack of transparency into the system: operators may be unable or find it very difficult to determine a) the current state and changes of state of the automation or robot, b) the current state and changes in state of the system being controlled or acted on, and c) what actions by human or by system had what effects. 5) If the human interfaces for operation and control of robotic agents are not designed to accommodate the unique points of view and operating environments of both the human and the robotic agent, then effective human-robot coordination cannot be achieved.

Zumbado, Jennifer Rochlis↗

Laser driver for a photocathode of an electron linear accelerator

A laser system is designed for operation with a photocathode electron gun for a linear accelerator with the following parameters of radiation at a wavelength of 262 nm (the fourth harmonic of a Nd:YLF laser). The pulse trains (macropulses) with a repetition rate of 5 Hz and a duration of 900 {mu}s consist of 8-ps micropulses with an energy of 1.4 {mu}J and a repetition rate of 2.708 MHz. This repetition rate is variable within {+-}32 kHz and is stabilised by an external signal with an accuracy of 10 Hz. Due to the use of a feedback-controlled acousto-optic modulator, the root-mean-square deviation of the micropulse energy in the first and second harmonics is 2.5% and 3.6%, respectively. Using the decaying branch of the dependence of the second-to-fourth harmonic conversion efficiency on the second harmonic intensity, we decreased the root-mean-square deviation of the energy of the fourth-harmonic micropulses to 2.3% at the first-to-fourth harmonic conversion efficiency of 27%. (lasers and amplifiers)

43 PARTICLE ACCELERATORS↗

A three-stage power amplifier for a 20 GHz monolithic transmit module

Design, fabrication, and test results of a three-stage GaAs monolithic power amplifier covering the 17.7 to 20.2 GHz band are described. Intermediate results for single and two-stage amplifiers are also presented. The 1.5 x 3.1 millimeter three-stage amplifier chip has 15 dB gain from 16.5 to 20.2 GHz. Measured saturated output power is between +20 and +21 dBm with improvement expected from minor circuit and device changes.

Petersen, W. C.↗

An Ultra-Compact X-ray Regenerative Amplifier Free-Electron Laser

There is a growing interest in designing and building compact X-ray Free Electron Lasers (FELs) for scientific and industry applications. In this paper, we report an X-ray Regenerative Amplifier FEL (XRAFEL) design based on a proposed Ultra Compact X-ray FEL configuration. Our results show that an XRAFEL can dramatically enhance the temporal coherence and increase the spectral brightness of the radiation in the hard X-ray regime without increasing the footprint of the FEL configuration. The proposed compact, fully coherent, and high-flux hard X-ray source holds promise as a valuable candidate for a wide range of high-impact applications in both academia and industry.

Singleton, Madison↗

Three MMIC Amplifiers for the 120-to-200 GHz Frequency Band

Closely following the development reported in the immediately preceding article, three new monolithic microwave integrated circuit (MMIC) amplifiers that would operate in the 120-to-200-GHz frequency band have been designed and are under construction at this writing. The active devices in these amplifiers are InP high-electron-mobility transistors (HEMTs). These amplifiers (see figure) are denoted the LSLNA150, the LSA200, and the LSA185, respectively. Like the amplifiers reported in the immediately preceding article, the LSLNA150 (1) is intended to be a prototype of low-noise amplifiers (LNAs) to be incorporated into spaceborne instruments for sensing cosmic microwave background radiation and (2) has potential for terrestrial use in electronic test equipment, passive millimeter-wave imaging systems, radar receivers, communication receivers, and systems for detecting hidden weapons. The HEMTs in this amplifier were fabricated according to 0.08- m design rules of a commercial product line of InP HEMT MMICs at HRL Laboratories, LLC, with a gate geometry of 2 fingers, each 15 m wide. On the basis of computational simulations, this amplifier is designed to afford at least 15 dB of gain, with a noise figure of no more than about 6 dB, at frequencies from 120 to 160 GHz. The measured results of the amplifier are shown next to the chip photo, with a gain of 16 dB at 150 GHz. Noise figure work is ongoing. The LSA200 and the LSA185 are intended to be prototypes of transmitting power amplifiers for use at frequencies between about 180 and about 200 GHz. These amplifiers have also been fabricated according to rules of the aforesaid commercial product line of InP HEMT MMICs, except that the HEMTs in these amplifiers are characterized by a gate geometry of 4 fingers, each 37 m wide. The measured peak performance of the LSA200 is characterized by a gain of about 1.4 dB at a frequency of 190 GHz; the measured peak performance of the LSA185 is characterized by a gain of about 2.7 dB at a frequency of 181 GHz. The measured gain results of each chip are shown next to their respective photos.

Samoska, Lorene↗

A Neutron Based Scanner to Detect Explosives in Small, Sealed Containers

A scanning system has been designed for portal protection applications, with the capability of detecting explosive materials after an initial scan of 30 seconds. The scanner operates using the principle of neutron induced return gamma-ray spectrometry. This system utilizes high purity germanium detectors, a neutron generator based on deuterium-tritium fusion and a unique neutron reflector and guide design. The neutron reflector amplifies the flux and alters the energy spectrum of neutrons produced by the generator. A depleted uranium reflector is shown to perform 7.3 times better than no reflector, and is found to perform 1.5 times better than a tungsten reflector using MCNP simulation. This improvement is due to neutron knockout and induced fission occurring in depleted uranium. The system is capable of detecting 300 g of explosives with 90% detection probability, which includes a 15% rescan rate after a 30 second initial scan.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Moment-based, self-consistent linear analysis of gyrotron oscillators

A new model for simulating gyrotron oscillators in the monomode time-dependent linear self-consistent regime is presented. Starting from a nonlinear time-dependent monomode model, the linearization and the following simplification of the model, based on a moment approach, are described. This simplified model represents a numerically efficient model and allows to have a deeper physical insight, in particular, for regimes dominated by self-consistent effects such as for the gyro-backward wave instability. One specific case of a gyrotron cavity is studied in detail and compared with experimental results, with special attention to self-consistent effects and to the differences with a model using a fixed field profile. Self-consistent linear simulations are, amongst other applications, important for the design of frequency-tunable gyrotrons or high-power gyrotrons with cavities having a relatively low quality factor, but also for studies of parasitic oscillations as they may occur in beam ducts and/or in the launcher section following the interaction cavity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced readout methods for superheated emulsion detectors

Superheated emulsions develop visible vapor bubbles when exposed to ionizing radiation. They consist in droplets of a metastable liquid, emulsified in an inert matrix. The formation of a bubble cavity is accompanied by sound waves. Evaporated bubbles also exhibit a lower refractive index, compared to the inert gel matrix. These two physical phenomena have been exploited to count the number of evaporated bubbles and thus measure the interacting radiation flux. Systems based on piezoelectric transducers have been traditionally used to acquire the acoustic (pressure) signals generated by bubble evaporation. Such systems can operate at ambient noise levels exceeding 100 dB; however, they are affected by a significant dead time (>10 ms). An optical readout technique relying on the scattering of light by neutron-induced bubbles has been recently improved in order to minimize measurement dead time and ambient noise sensitivity. Beams of infra-red light from light-emitting diode (LED) sources cross the active area of the detector and are deflected by evaporated bubbles. The scattered light correlates with bubble density. Planar photodiodes are affixed along the detector length in optimized positions, allowing the detection of scattered light from the bubbles and minimizing the detection of direct light from the LEDs. A low-noise signal-conditioning stage has been designed and realized to amplify the current induced in the photodiodes by scattered light and to subtract the background signal due to intrinsic scattering within the detector matrix. The proposed amplification architecture maximizes the measurement signal-to-noise ratio, yielding a readout uncertainty of 6% (±1 SD), with 1000 evaporated bubbles in a detector active volume of 150 ml (6 cm detector diameter). In this work, we prove that the intensity of scattered light also relates to the bubble size, which can be controlled by applying an external pressure to the detector emulsion. This effect can be exploited during the readout procedure to minimize shadowing effects between bubbles, which become severe when the latter are several thousands. The detector we used in this work is based on superheated C-318 (octafluorocyclobutane), emulsified in 100 μm ± 10% (1 SD) diameter drops in an inert matrix of approximately 150 ml. The detector was operated at room temperature and ambient pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pedestal fluctuation measurements with charge exchange imaging at the DIII-D tokamak

A new high radial resolution 2D multichannel Charge eXchange Imaging (CXI) diagnostic is under development for deployment at DIII-D. Here, the diagnostic system will measure low-to-intermediate radial wavenumber carbon density fluctuations by observing the n = 8 – 7 (λ = 529.06 nm) C-VI emission line, resulting from charge exchange collisions between heating neutral beam atoms and the intrinsic carbon ion density. The new CXI diagnostic will provide measurements with ΔR ~ 0.4 cm to access higher k r instabilities (k r < 8 cm –1 ) predicted to arise in the steep-gradient region of the H-mode pedestal. The CXI system will feature 60 fiber bundles in a 12 × 5 arrangement, with each bundle consisting of four 1 mm fibers. A custom optical system has been designed to filter and image incoming signals onto an 8 × 8 avalanche photodiode array. Additionally, a novel electronics suite has been designed and commissioned to amplify and digitize the relatively low-intensity carbon signal at a 2 MHz bandwidth. Forward modeling results of the active C-VI emission suggest sufficient signal to noise ratios to resolve turbulent fluctuations. Prototype measurements demonstrate the ability to perform high frequency pedestal measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗