Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIR FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Stack Test Summary for TA-59-0001

The Radioactive Air Emissions Management (RAEM) team performed stack flow characterization tests at Technical Area (TA) 59 Building 0001 Exhaust Stack (ES) 8. These tests were completed in accordance with Title 40 of the Code of Federal Regulations (CFR), Part 61, Subpart H and the American National Standards Institute (ANSI) N13.1-1999 required by the Clean Air Act. Subpart H of the regulation is the National Emission Standards for Hazardous Air Pollutants (NESHAP) for radionuclides, which compliance with is maintained by the REAM team.

54 ENVIRONMENTAL SCIENCES↗

Experimental Characterization of High-Surface Area Thermal Energy Storage

There is growing interest in energy storage technologies due to the expansion of renewable energy sources that are inherently intermittent and the increasing frequency of extreme weather events that disturb the power grid. Power consumption in buildings makes up approximately 76% of all electricity usage on the grid and is primarily used for thermal applications such as space conditioning, hot water, and cooking. This makes thermal energy storage (TES) an ideal solution for many of these applications. Many TES technologies rely on latent energy storage, which utilizes the melting/solidification of phase change materials (PCM) to store energy. Typically, TES designs suffer from low power density due to their low inherent thermal conductivity. This limitation makes the deployment of TES in active applications difficult as the ease of access to energy is essential for effective use. Common routes for improving power density include high thermal conductivity additives or extended features such as fins that increase cost. This study presents an alternative approach to improving performance through increasing the overall surface area to volume ratio of the device, to increase the available area for convection to occur between the working fluid and PCM. In the study a commercial PCM was selected with a transition temperature ideal for space heating applications. The heat exchanger design utilizes a unique application of triply periodic minimal surfaces (TPMS) for macro-encapsulation of the PCM. The use of TPMS for heat exchangers has been growing in interest due to their high-surface area to volume ratios, which were previously unmanufacturable until the development of additive manufacturing. A modular system was designed and manufactured with a stereolithography resin printing system that is then backfilled with PCM. An experiment test set-up is designed to test the charge and discharge performance of the thermal storage using a conditioned air stream. The pressure drop of the design is tested across a variety of flow rates. When compared to existing experimental data within literature, there is excellent agreement based on the Reynolds number at similar hydraulic diameters. Several inlet temperatures are tested at consistent temperature differences from the phase change temperature for both charging and discharging. Additionally, the volumetric flow rate is varied for each temperature set point. It was found that increasing flow rate had diminishing returns in reducing the overall charge time of the TES. The temperature delta from the melting temperature was the primary contributor to the change in average heat flux with limited variation in average heat transfer rate between charging and discharging at similar inlet temperatures and flow rates. The TPMS heat exchanger design has a high air-side pressure drop but it provides high heat transfer rates. This helps maintain a high outlet temperature during discharge, which is important to thermal comfort applications. The design, manufacturing, and experimental characterization of the TES device will be presented as part of this study.

25 ENERGY STORAGE↗

Improving air leakage prediction of buildings using the fan pressurization method with the Weighted Line of Organic Correlation

In many countries, the fan pressurization method is the most frequently chosen approach for measuring the air leakage of houses. The measurements are usually performed at pressures that far exceed pressures to which buildings are exposed to under normal conditions. A fit of these tests to the power-law formulation allows an extrapolation to data points outside the measured pressure range. With the Ordinary Least Square (OLS) fitting method, the pressure exponent and flow coefficient can be determined. However, the measurement results are highly sensitive to uncertainties induced by external factors like changing wind conditions during the tests, which is neglected by OLS. This may lead to errors in the prediction of flows at lower pressures. The Weighted Line of Organic Correlation (WLOC) is an alternative approach and takes measurement uncertainty into account. In this paper, a statistical analysis of an extensive data set of pressurization measurements has been performed. Both regression techniques have been compared for almost 7500 fan pressurization measurements of six houses in 109 different house leak configurations. The variability in predicting pressure exponent and flow coefficient for both WLOC and OLS regression was analyzed using probability density functions. It was found that the Weighted Line of Organic Correlation significantly decreases the uncertainty in predicting pressure exponent, flow coefficient, and other low-pressure air leakage metrics compared to the Ordinary Least Square fitting. Here, the authors highly recommend the implementation of WLOC in current measurement standards and test equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recovery of Natural Gas Equipment Emissions into Gas Compression Engines for the Reduction of Potential Greenhouse Gas Emissions

Since the turn of the millennium, the United States (U.S.) oil and natural gas (ONG) industry has nearly doubled its natural gas production rate. As a result, the ONG industry has recently come under increasing scrutiny for its contributions to greenhouse gas (GHG) emissions. Consequently, various solutions to this problem have been proposed and formulated to reduce the impacts of GHG emissions on the environment. West Virginia University (WVU) have found it important to research the impacts of recovering vented gas streams into prime-mover engines. The U.S. Department of Energy (DOE) and National Energy Technology Laboratory (NETL) have granted WVU funding to research and develop a “Methane Mitigator” (M2) - a “Scalable Vent Mitigation Strategy to Simultaneously Reduce Methane Emissions and Fuel Consumption from the Compression Industry.” One of the main areas of interest for this research was the collection of emissions from natural gas equipment into a Caterpillar G3508J natural gas compression engine. The parameters being analyzed from the engine were brake-specific emissions and power output. The emissions sources considered for this research were pneumatic controllers (PCs), reciprocating compressor vents, and the engine’s open crankcase breather. The compressor vent and PC emissions were simulated using a mass flow controller (MFC) and flowed into the engine using two separate methods: (1) directly into the air intake, and (2) through a retrofitted closed crankcase ventilation system (CCV), serving as a buffer volume. The crankcase emissions were quantified without the CCV, and the impact on exhaust emissions from circulating the crankcase gases into the intake was measured. The simulated compressor vent and PC flows from the MFC had limited effect on the steady state operation of the engine and resulting performance. When the simulated flows were fed directly into the engine’s air intake, the changes within the engine’s continuous performance and emission parameters were larger but lasted for shorter durations. Conversely, when the simulated flows were fed into the CCV before entering the air intake, the changes in the engine’s performance and emission parameters were less pronounced for continuous analysis but lasted for longer durations. In either case, the continuous emission changes in both emissions and performance varied in size depending on the test scenario being run, but the cycle average changes in emissions and performance showed little impact overall compared to the engine’s baseline operation. As a result, the inclusion of a CCV shows a decrease in baseline carbon dioxide equivalent (CO2-eq.) engine emissions (from combined exhaust and open crankcase) of almost 4%. Likewise, the CCV inclusion reduced baseline total methane (CH4) from combined exhaust and open crankcase by upwards of 16%. These atmospheric emissions only decreased further with the inclusions of collected PC and compressor vent flows. The resulting changes in time-averaged rated exhaust behavior (or lack thereof) prove that the proposed M2 system could likely be deployed at sites with modern lean-burn natural gas engines as a viable option for reducing and eliminating potential GHG sources that would have otherwise been unutilized as energy sources.

03 NATURAL GAS↗

Development of SAM Code Capabilities for Safety Analysis of GCR Air-ingress Events

Air-ingress following a depressurized loss-of-forced-cooling (DLOFC) event is a challenging, multiphysics safety scenario for High-Temperature Gas-Cooled Reactors (HTGRs), involving coupled gas composition transport, buoyancy-driven flow redistribution, graphite oxidation, and structural heat-up. Despite its importance — air ingress is a key scenario identified in the PIRT process for the HTGRs — existing system-level safety codes have lacked the integrated capability to simulate the complete event sequence with high confidence. This report documents the development, validation, and demonstration of three new capabilities in the SAM code to address this gap: (1) a multi-component gas mixture flow model with binary diffusion to track the helium-air composition and its effect on system density and flow; (2) a 0-D graphite oxidation model based on the Roes correlation, including oxygen consumption and exothermic heat release; and (3) an isentropic critical flow model for accurate representation of primary system depressurization through a break. These capabilities are validated against two benchmark experiments. The NSTF heavy-gas ingress experiment validates the multi-component flow model: SAM correctly reproduces the rapid buoyancydriven flow stagnation and subsequent natural circulation recovery driven by composition-dependent density changes. The NACOK graphite oxidation experiment validates the oxidation model: SAM predicts a bottom-level graphite weight loss of 25%, in close agreement with the measured 24%, and reproduces the strong axial nonuniformity and block-geometry dependence of oxidation, at a level comparable to the SPECTRA and TINTE codes. The validated capabilities are then exercised together in an integrated, reactor-scale simulation of a DLOFC air-ingress transient in a simplified HTR-PM pebble-bed reactor. In a single calculation spanning approximately 8 days, SAM reproduces the complete accident sequence: rapid depressurization, densityand diffusion-driven air ingress over ˜15 hours, onset of buoyancy-driven natural circulation, exothermic graphite oxidation with a peak fuel temperature at ˜62 hours, and eventual passive cooldown. These results demonstrate that SAM now provides the nuclear community with a preliminarily validated, modern systemlevel tool for HTGR air-ingress safety analysis, filling a recognized capability gap. Future extensions to broaden species tracking, improve oxidation chemistry, and refine the reactor model are discussed.

Yang, Gang↗

, Experimental Investigation of Electrically Charged Water Droplets Two-Phase Cross-Flow Interactions with Humid

Electrically charged water droplets can capture water vapor molecules in surrounding moist air and promote vapor condensation. This concept unfolds an alternative to mechanical cooling-based air dehumidification systems that separate sensible and latent cooling loads in HVAC applications. The effect of dielectrophoresis, electro-hydrodynamic, and micro-diffusive flows due to highly electrically charged water droplets traveling through moist air were investigated as new methods to reduce the air’s water vapor content. This paper presents new experimental data on humidification and power consumption for a system consisting of highly energized electrosprays in combination with mist eliminators. Electrosprays produced highly charged water spray cones crossing the air perpendicularly and upwardly. The moist air stream was circulated in a horizontal duct at 22C, 80% relative humidity, and 0.24 ms-1 airspeed. Mist eliminators made of stainless wire clothes of 36 and 25 μm pore diameter were used to screen the droplets growing during their flight trajectory. The mist eliminators blocked some of the largest diameter droplets. Still, they could not prevent re-evaporation of the droplets into the bulk air from the droplets deposited on their wire clothes. The equilibrium between the dielectrophoresis condensation from the electrosprays and the droplets’ re-evaporation phenomena resulted in reduced humidification when compared to conventional-type spray evaporative cooling systems. However, to dehumidify the air, the droplets injected by the electrosprays must be separated entirely and promptly removed from the bulk airflow at the end of their flight trajectory.

Electrostatic droplets, Electrospray, humidificati↗

A Hierarchy of Global Ocean Models Coupled to CESM1

Abstract We develop a hierarchy of simplified ocean models for coupled ocean, atmosphere, and sea ice climate simulations using the Community Earth System Model version 1 (CESM1). The hierarchy has four members: a slab ocean model, a mixed‐layer model (MLM) with entrainment and detrainment, an Ekman MLM, and an ocean general circulation model (OGCM). Flux corrections of heat and salt are applied to the simplified models ensuring that all hierarchy members have the same climatology. We diagnose the needed flux corrections from auxiliary simulations in which we restore the temperature and salinity to the daily climatology obtained from a target CESM1 simulation. The resulting three‐dimensional corrections contain the interannual variability fluxes that maintain the correct vertical gradients of temperature and salinity in the tropics. We find that the inclusion of mixed‐layer entrainment and Ekman flow produces sea surface temperature and surface air temperature fields whose means and variances are progressively more similar to those produced by the target CESM1 simulation. We illustrate the application of the hierarchy to the problem of understanding the response of the climate system to the loss of Arctic sea ice. We find that the shifts in the positions of the mid‐latitude westerly jet and of the Inter‐tropical Convergence Zone (ITCZ) in response to sea‐ice loss depend critically on upper ocean processes. Specifically, heat uptake associated with the mixed‐layer entrainment influences the shift in the westerly jet and ITCZ. Moreover, the shift of ITCZ is sensitive to the form of Ekman flow parameterization.

54 ENVIRONMENTAL SCIENCES↗

A hierarchy of global ocean models coupled to CESM1

We develop a hierarchy of simplified ocean models for coupled ocean, atmosphere, and sea ice climate simulations using the Community Earth System Model version 1 (CESM1). The hierarchy has four members: a slab ocean model, a mixed-layer model (MLM) with entrainment and detrainment, an Ekman MLM, and an ocean general circulation model (OGCM). Flux corrections of heat and salt are applied to the simplified models ensuring that all hierarchy members have the same climatology. We diagnose the needed flux corrections from auxiliary simulations in which we restore the temperature and salinity to the daily climatology obtained from a target CESM1 simulation. The resulting three-dimensional corrections contain the interannual variability fluxes that maintain the correct vertical gradients of temperature and salinity in the tropics. We find that the inclusion of mixed-layer entrainment and Ekman flow produces sea surface temperature and surface air temperature fields whose means and variances are progressively more similar to those produced by the target CESM1 simulation. We illustrate the application of the hierarchy to the problem of understanding the response of the climate system to the loss of Arctic sea ice. We find that the shifts in the positions of the mid-latitude westerly jet and of the Inter-tropical Convergence Zone (ITCZ) in response to sea-ice loss depend critically on upper ocean processes. Specifically, heat uptake associated with the mixed-layer entrainment influences the shift in the westerly jet and ITCZ. Moreover, the shift of ITCZ is sensitive to the form of Ekman flow parameterization.

54 ENVIRONMENTAL SCIENCES↗

A physics-based model for frost buildup under turbulent flow using direct numerical simulations

We present a new model for frost buildup under turbulent (and laminar) flow using direct numerical simulations. The physical model consists of two layers, the air and the frost. The air layer is fully resolved and consists of solving for the velocity, temperature, and vapor mass fraction fields. The frost layer thickness is resolved using conservation of mass and energy. Both phases are dynamically coupled using the immersed boundary method. Three-dimensional simulations are conducted in an open-channel configuration. A number of challenges need to be overcome to make these simulations feasible. First, to enforce far-field conditions of zero gradient and prescribed mean temperature and humidity, a source term is added to the energy and transport equations in the flow solver. Second, the mean frost thickness is subtracted after each time step to ensure a constant mean flow thickness and level of turbulence in the numerical domain. Third, a slow-time acceleration approach, which accelerates the frost buildup by a predetermined factor, is employed to bridge the gap between the fast turbulent and slow frost buildup time scales. Finally, a frost densification scheme is used to overcome the difficulties of vertically varying frost properties. The model is validated by comparing the frost thickness and frost thickness buildup rate over a period of one hour from a cooled flat plate experiment. As a result, both quantities compare favorably with experiments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Separating Sensible and Latent Cooling with Electrically Charged Rotating Vortexes and Vapor Capturing Air Handler Technology

The dehumidification of air is a highly energy-intensive process, typically requiring vapor compression systems to cool the air below its dew point temperature. This project investigated air dehumidification achieved by electrostatic and dielectrophoresis forces in electrosprays and centrifugal principles in cyclone separators. As a practical implementation of these processes, Electrospray Vortical Flow eXchanger (EVFX) prototypes were designed, fabricated, and tested. Electrosprays were employed to energize water droplets, which then captured water vapor via dielectrophoresis. A cyclone separator was positioned downstream of the electrosprays. This combination increased the dehumidification efficiency and controlled the flow of the water vapor condensate removed from the air.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

September 2023 - Mini Blast Tube Experimental Results [Slides]

Ryan Rettinger (M-6): provided the python script for extracting the pressure data. Joseph Kerwin (E-14): provided the countless pictures taken during the flow shots. Chris Long (W-13): provided the simulation data shown in the upcoming slides.

42 ENGINEERING↗

Development of a Model Correlating Axial HEPA Filter Performance Between Elevated and Standard Conditions

The ASME AG-1 Code specifies minimum rated airflow based on standard cubic feet per minute (SCFM) for axial high efficiency particulate air (HEPA) filters and actual cubic feet per minute (ACFM) for radial HEPA filters with corresponding maximum pressure drop. A quantitative analysis can be performed to demonstrate the variation in filter efficiency and develop a correlation of performance between axial filters subjected to ACFM and SCFM. This study illustrates the variation in filter efficiency of axial HEPA filters subjected to ACFM and SCFM flow rate conditions at varying atmospheric pressures. It also presents the methods used to calculate correction factors to convert filter efficiency and pressure drop from elevated to standard conditions. The Axial Large Scale Test Stand (ALSTS) in the Institute for Clean Energy Technology (ICET) at Mississippi State University has been utilized to control aerosol concentration, flowrate, atmospheric pressure, relative humidity, and temperature. The filter test matrix consists of axial HEPA filters rated at 1,000 and 1,500 CFM with varying filter pack types. Each filter is subjected to varying pressures of 14.70 psi, 13.55 psi, 12.40 psi, and 11.25 psi, temperatures of 70 deg. F, 110 deg. F, and 150 deg. F, and relative humidities of 50% and 80%, resulting in twenty-four unique testing points. The corresponding SCFM flow rates are computed for each point in order to form a comparison. Evaluation of the effects of designating ACFM or SCFM will be based upon the filter efficiencies of generated Dioctyl Phthalate (DOP) particles at a diameter of 0.3 micrometers. The results show filter efficiency decreasing as atmospheric pressure decreases due to increased filter face velocity. A correlation model is developed to convert filter efficiency and pressure drop at elevated conditions to those of standard pressure, relative humidity, and temperature.

42 ENGINEERING↗

Shock tube experiments on the three-layer Richtmyer–Meshkov instability

Here, a vertical shock tube is used for experiments on the three-layer Richtmyer–Meshkov instability. Two closely spaced membrane-less interfaces are formed by the flow of two different sects of three gases: one with air above CO 2 above SF 6 and the other with helium above air above SF 6 . The lightest of the three gases enters the shock tube at the top of the driven section and flows downward. Conversely, the heaviest gas enters at the bottom of the shock tube and flows upward while the intermediate density gas enters at the middle through porous plates. All three gases are allowed to escape through holes at the layer location, leaving an approximately 30-mm layer of intermediate-density gas suspended between the lightest gas from above and the heaviest gas from below. A single-mode, two-dimensional initial perturbation is then imposed on the lower interface by oscillating the shock tube in the horizontal direction. The flow is visualized by seeding the intermediate gas with particles and illuminating it with a pulsed laser. Image sequences are then captured using high-speed video cameras. Perturbation amplitude measurements are made from the three-layer system and compared with measurements from 2, two-layer systems. It is observed that the presence of the upper, initially flat interface produces a decrease in growth of instability amplitude in the nonlinear phase over an equivalent single-interface configuration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluating the Effect of Vane Trailing Edge Flow on Turbine Rim Sealing

Abstract Modern gas turbine development continues to move toward increased overall efficiency, driven in part by higher firing temperatures that point to a need for more cooling air to prevent catastrophic component failure. However, using additional cooling flow bled from the upstream compressor causes a corresponding detriment to overall efficiency. A primary candidate for cooling flow optimization is purge flow, which contributes to sealing the stator–rotor cavity and prevents ingestion of hot main gas path (MGP) flow into the wheelspace. Previous research has identified that the external main gas path flow physics play a significant role in driving rim seal ingestion. However, the potential impact of other cooling flow features on ingestion behavior, such as vane trailing edge (VTE) flow, is absent in the open literature. This paper presents experimental measurements of rim cavity cooling effectiveness collected from a one-stage turbine operating at engine-representative Reynolds and Mach numbers. Carbon dioxide (CO2) was used as a tracer gas in both the purge flow and vane trailing edge flow to investigate flow migration into and out of the wheelspace. Results show that the vane trailing edge flow does in fact migrate into the rim seal and that there is a superposition relationship between individual cooling flow contributions. Computational fluid dynamics (CFD) simulations using unsteady Reynolds-averaged Navier–Stokes (URANS) were used to confirm VTE flow ingestion into the rim seal cavity. Radial and circumferential traverse surveys were performed to quantify cooling flow radial migration through the main gas path with and without vane trailing edge flow. The surveys confirmed that vane trailing edge flow is entrained into the wheelspace as purge flow is reduced. Local CO2 measurements also confirmed the presence of VTE flow deep in the wheelspace cavity.

Engineering↗

Flood Estimation under Snowmelt and Rain-on-Snow Processes in Alaska: A Military Installation Perspective

Accurate flood estimation in snow-dominated and high-latitude regions remains challenging due to complex interactions among rainfall, snowmelt, and rain-on-snow (ROS) processes, which are not captured in conventional precipitation-based intensity-duration-frequency (PREC-IDF) curves. This study evaluates the Next-Generation IDF (NG-IDF) framework, an extension of PREC-IDF that incorporates total water available for runoff (precipitation minus changes in snow water equivalent), in two contrasting Alaskan watersheds of Department of Defense (DoD) significance: the Little Chena River Basin (LCRB) in interior Alaska, a tributary of the Chena River that flows through Fort Wainwright and near Eielson Air Force Base, and the Upper Ship Creek Basin (USCB), which drains Joint Base Elmendorf-Richardson near Anchorage. Using long-term SNOTEL observations and event-based rainfall-runoff modeling, NG-IDF and PREC-IDF flood estimates were compared against observation-based flood frequency analyses. Results show that NG-IDF consistently reduces flood-estimation bias by 15–20% relative to PREC-IDF, particularly for snowmelt- and ROS-dominated events. In the interior LCRB, permafrost conditions can substantially amplify flood responses during snowmelt events, an effect not explicitly represented in standard design tools. These findings demonstrate that NG-IDF provides a more physically consistent and transferable framework for flood estimation in cold regions, with potential relevance to mission-critical DoD installation resilience. Projected increases in ROS frequency and permafrost degradation across Alaska further emphasize the need to integrate physics-based hydrologic models that explicitly represent snow and permafrost processes to enhance design resilience and operational readiness for military and other critical infrastructure.

Yan, Hongxiang (ORCID:000000022387403X)↗

TReactMech v4.217

TReactMech couples geomechanical processes (poroelasticity, failure, and inelastic strain) with multiphase nonisothermal flow (derived from TOUGH2) and reactive geochemical transport. At its core is the reactive-transport code TOUGHREACT v4.13. TReactMech is an efficient hybrid parallel simulator, solving the geomechanics using finite elements and MPI/PetSc, the multiphase flow using integrated finite difference and MPI/PETSc, and the reactive chemistry using OpenMP. The advantages of TReactMech are in its multiphase flow capabilities (e.g., supercritical CO2, supercritical water, air) and parallel geomechanics including full 3-D stress tensor, shear and tensile failure, coupled to porosity and permeability changes. It is backwardly compatible with TOUGH2 and TOUGHREACT v4.13, allowing for easier transitions between the codes. TReactMech can be used to simulate many natural and engineered subsurface systems, including geothermal reservoirs, borehole heat exchangers, geologic carbon sequestration, geologic storage of nuclear waste, groundwater resources, weathering, sediment diagenesis, seafloor hydrothermal circulation, hydrofracturing in unconventional reservoirs, and injection/production-induced surface deformation.

Sonnenthal, Eric↗

Evaluation of residual gas fraction estimation methods for cycle-to-cycle combustion variability analysis and modeling

Cycle-to-cycle combustion variability in spark-ignition engines during normal operation is mainly caused by random perturbations of the in-cylinder conditions such as the flow velocity field, homogeneity of the air-fuel distribution, spark energy discharge, and turbulence intensity of the flame front. Such perturbations translate into the variability of the energy released observed at the end of the combustion process. During normal operating conditions, the cycle-to-cycle variability (CCV) of the energy release behaves as random uncorrelated noise. However, during diluted combustion, in either the form of exhaust gas recirculation (EGR) or excess air (lean operation), the CCV tends to increase as dilution increases. Moreover, when the ignition limit is reached at high dilution levels, the combustion CCV is exacerbated by sporadic occurrences of incomplete combustion events, and the uncorrelation assumption no longer holds. The low or null energy released by partial burns and misfires has an impact on the following combustion event due to the residual gas that carries burned and unburned gases, which contributes to the deterministic coupling between engine cycles. Many residual gas fraction estimation methods, however, only address the nominal case where complete combustion occurs and combustion events are uncorrelated. Here we evaluate the efficacy of such methods on capturing the effects of partial burns and misfires on the residual gas estimate for high-EGR operation. The advantages and disadvantages of each method are discussed based on their ability to generate cycle-to-cycle estimates. Finally, a comparison between the different estimation techniques is presented based on their usefulness for control-oriented modeling.

42 ENGINEERING↗

Vanderbilt Alumni Hall

This dataset includes processed and raw data from the Vanderbilt Alumni Hall Building (VAH) located on the University of Vanderbilt Campus in Nashville, TN. VAH is a mixed use commercial building (LEED Gold Certified) that consists of classrooms, meeting rooms, office rooms, conference rooms, an exercise room, and others. This dataset spans one year of time-series data from 2019 and includes measurements corresponding to whole building electrical power, thermal power, zone level thermal power, set-point, indoor temperature, humidity, water and air side supply and return temperatures and flow rates as CSV files. In addition to the measurements, a metadata .json file, and a .ttl file to visualize the data as per BRICK schema are also included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗