Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Poster — Thur Eve — 12: Implementation of a Clinical Lung Tumour High Dose Containment Verification Procedure using Respiratory Cone-Beam CT (4DCBCT) on a Varian TrueBeam Linac

Lung tumours move due to respiratory motion. This is managed during planning by acquiring a 4DCT and capturing the excursion of the GTV (gross tumour volume) throughout the breathing cycle within an IGTV (Internal Gross Tumour Volume) contour. Patients undergo a verification cone-beam CT (CBCT) scan immediately prior to treatment. 3D reconstructed images do not consider tumour motion, resulting in image artefacts, such as blurring. This may lead to difficulty in identifying the tumour on reconstructed images. It would be valuable to create a 4DCBCT reconstruction of the tumour motion to confirm that does indeed remain within the planned IGTV. CBCT projections of a Quasar Respiratory Motion Phantom are acquired in Treatment mode (half-fan scan) on a Varian TrueBeam accelerator. This phantom contains a mobile, low-density lung insert with an embedded 3cm diameter tumour object. It is programmed to create a 15s periodic, 2cm (sup/inf) displacement. A Varian Real-time Position Management (RPM) tracking-box is placed on the phantom breathing platform. Breathing phase information is automatically integrated into the projection image files. Using in-house Matlab programs and RTK (Reconstruction Tool Kit) open-source toolboxes, the projections are re-binned into 10 phases and a 4DCBCT scan reconstructed. The planning IGTV is registered to the 4DCBCT and the tumour excursion is verified to remain within the planned contour. This technique successfully reconstructs 4DCBCT images using clinical modes for a breathing phantom. UBC-BCCA ethics approval has been obtained to perform 4DCBCT reconstructions on lung patients (REB#H12-00192). Clinical images will be accrued starting April 2014.

60 APPLIED LIFE SCIENCES↗

Poster - 40: Treatment Verification of a 3D-printed Eye Phantom for Proton Therapy

Purpose: Ocular melanoma is a form of eye cancer which is often treated using proton therapy. The benefit of the steep proton dose gradient can only be leveraged for accurate patient eye alignment. A treatment-planning program was written to plan on a 3D-printed anatomical eye-phantom, which was then irradiated to demonstrate the feasibility of verifying in vivo dosimetry for proton therapy using PET imaging. Methods: A 3D CAD eye model with critical organs was designed and voxelized into the Monte-Carlo transport code FLUKA. Proton dose and PET isotope production were simulated for a treatment plan of a test tumour, generated by a 2D treatment-planning program developed using NumPy and proton range tables. Next, a plastic eye-phantom was 3D-printed from the CAD model, irradiated at the TRIUMF Proton Therapy facility, and imaged using a PET scanner. Results: The treatment-planning program prediction of the range setting and modulator wheel was verified in FLUKA to treat the tumour with at least 90% dose coverage for both tissue and plastic. An axial isotope distribution of the PET isotopes was simulated in FLUKA and converted to PET scan counts. Meanwhile, the 3D-printed eye-phantom successfully yielded a PET signal. Conclusions: The 2D treatment-planning program can predict required parameters to sufficiently treat an eye tumour, which was experimentally verified using commercial 3D-printing hardware to manufacture eye-phantoms. Comparison between the simulated and measured PET isotope distribution could provide a more realistic test of eye alignment, and a variation of the method using radiographic film is being developed.

60 APPLIED LIFE SCIENCES↗

Guiding the design of oxidation-resistant Fe-based single atom alloy catalysts with insights from configurational space

The high activity and selectivity of Fe-based heterogeneous catalysts toward a variety of reactions that require the breaking of strong bonds are offset in large part by their considerable instability with respect to oxidative deactivation. While it has been shown that the stability of Fe catalysts is considerably enhanced by alloying them with precious metals (even at the single-atom limit), rational design criteria for choosing such secondary metals are still missing. Since oxidative deactivation occurs due to the strong binding of oxygen to Fe and reduction by adsorbed hydrogen mitigates the deactivation, we propose here to use the binding affinity of oxygen and hydrogen adatoms as the basis for rational design. As it would also be beneficial to use cheaper secondary metals, we have scanned over a large subset of 3d–5d mid-to late transition metal single atoms and computationally determined their effect on the oxygen and hydrogen adlayer binding as a function of chemical potential and adsorbate coverage. We further determine the underlying chemical origins that are responsible for these effects and connect them to experimentally tunable quantities. Our results reveal a reliable periodic trend wherein oxygen binding is weakened greatest as one moves right and down the periodic table. Hydrogen binding shows the same trend only at high (but relevant) coverages and otherwise tends to have its binding slightly increased in all systems. Trends with secondary metal coverage are also uncovered and connected to experimentally tunable parameters.

Hensley, Alyssa↗

Carbon dioxide transport and sorption behavior in confined coal cores for carbon sequestration

Measurements of sorption isotherms and transport properties of carbon dioxide (CO{sub 2}) in coal cores are important for designing enhanced coalbed-methane/CO{sub 2}-sequestration field projects. Many of the coals will be deep and under considerable lithostatic and hydrostatic pressures. These lithostatic pressures may reduce the sorption capacities and/or transport rates significantly. Consequently, we have studied apparent sorption and diffusion in a coal core under confining pressure. A core from the important bituminous coal Pittsburgh no. 8 was kept under a constant, 3D effective stress; the sample was scanned by X-ray computer tomography (CT) before, then while, it sorbed CO{sub 2}. Increases in sample density because of sorption were calculated from the CT images. Moreover, density distributions for small volume elements inside the core were calculated and analyzed. Qualitatively, the CT showed that gas sorption advanced at different rates in different regions of the core and that diffusion and sorption progressed slowly. The amounts of CO{sub 2} sorbed were plotted vs. position (at fixed times) and vs. time (for various locations in the sample). The resulting sorption isotherms were compared to isotherms obtained from powdered coal from the same Pittsburgh no. 8 extended sample. The results showed that for this single coal at specified times, the apparent sorption isotherms were dependent on position of the volume element in the core and the distance from the CO{sub 2} source. Also, the calculated isotherms showed that less CO{sub 2} was sorbed than by a powdered (and unconfined) sample of the coal. Changes in density distributions during the experiment were also observed. After desorption, the density distribution of calculated volume elements differed from the initial distribution, suggesting hysteresis and a possible rearrangement of coal structure because of CO{sub 2} sorption.

01 COAL, LIGNITE, AND PEAT↗

Performance of the NIRS fast scanning system for heavy-ion radiotherapy

Purpose: A project to construct a new treatment facility, as an extension of the existing HIMAC facility, has been initiated for the further development of carbon-ion therapy at NIRS. This new treatment facility is equipped with a 3D irradiation system with pencil-beam scanning. The challenge of this project is to realize treatment of a moving target by scanning irradiation. To achieve fast rescanning within an acceptable irradiation time, the authors developed a fast scanning system. Methods: In order to verify the validity of the design and to demonstrate the performance of the fast scanning prior to use in the new treatment facility, a new scanning-irradiation system was developed and installed into the existing HIMAC physics-experiment course. The authors made strong efforts to develop (1) the fast scanning magnet and its power supply, (2) the high-speed control system, and (3) the beam monitoring. The performance of the system including 3D dose conformation was tested by using the carbon beam from the HIMAC accelerator. Results: The performance of the fast scanning system was verified by beam tests. Precision of the scanned beam position was less than {+-}0.5 mm. By cooperating with the planning software, the authors verified the homogeneity of the delivered field within {+-}3% for the 3D delivery. This system took only 20 s to deliver the physical dose of 1 Gy to a spherical target having a diameter of 60 mm with eight rescans. In this test, the average of the spot-staying time was considerably reduced to 154 {mu}s, while the minimum staying time was 30 {mu}s. Conclusions: As a result of this study, the authors verified that the new scanning delivery system can produce an accurate 3D dose distribution for the target volume in combination with the planning software.

60 APPLIED LIFE SCIENCES↗

Complete Tem-Tomography: 3D Structure of Gems Cluster

GEMS (glass with embedded metal and sulfide) grains in interplanetary dust particles (IDPs) are considered to be one of the ubiquitous and fundamental building blocks of solids in the Solar System. They have been considered to be interstellar silicate dust that survived various metamorphism or alteration processes in the protoplanetary disk but the elemental and isotopic composition measurements suggest that most of them have been formed in the protoplanetary disk as condensates from high temperature gas. This formation model is also supported by the formation of GEMS-like grains with respect to the size, mineral assemblage, texture and infrared spectrum by condensation experiments from mean GEMS composition materials. Previous GEMS studies were performed only with 2D observation by transmission electron microscopy (TEM) or scanning TEM (STEM). However, the 3D shape and structure of GEMS grains and the spatial distribution of Fe/FeS's has critical information about their formation and origin. Recently, the 3D structure of GEMS grains in ultrathin sections of cluster IDPs was revealed by electron tomography using a TEM/STEM (JEM-2100F, JEOL). However, CT images of thin sections mounted on Cu grids acquired by conventional TEM-tomography are limited to low tilt angles (e. g., less than absolute value of 75 deg. In fact, previous 3D TEM observations of GEMS were affected by some artifacts related to the limited tilt range in the TEM used. Complete tomographic images should be acquired by rotating the sample tilt angle over a range of more than absolute value of 80 deg otherwise the CT images lose their correct structures. In order to constrain the origin and formation process of GEMS grains more clearly, we performed complete electron tomography for GEMS grains. Here we report the sample preparation method we have developed for this study, and the preliminary results.

Matsuno, J.↗

SU-E-J-187: Individually Optimized Contrast-Enhancement 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

Purpose: To study the feasibility of individually optimized contrastenhancement (CE) 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. To evaluate the image quality and contrast enhancement of tumor in the CE 4D-CT, compared to the clinical standard of CE 3D-CT and 4D-CT. Methods: In this IRB-approved study, each of the 7 PDA patients enrolled underwent 3 CT scans: a free-breathing 3D-CT with contrast (CE 3D-CT) followed by a 4D-CT without contrast (4D-CT) in the first study session, and a 4D-CT with individually synchronized contrast injection (CE 4D-CT) in the second study session. In CE 4D-CT, the time of full contrast injection was determined based on the time of peak enhancement for the test injection, injection rate, table speed, and longitudinal location and span of the pancreatic region. Physicians contoured both the tumor (T) and the normal pancreatic parenchyma (P) on the three CTs (end-of-exhalation for 4D-CT). The contrast between the tumor and normal pancreatic tissue was computed as the difference of the mean enhancement level of three 1 cm3 regions of interests in T and P, respectively. Wilcoxon rank sum test was used to statistically compare the scores and contrasts. Results: In qualitative evaluations, both CE 3D-CT and CE 4D-CT scored significantly better than 4D-CT (4.0 and 3.6 vs. 2.6). There was no significant difference between CE 3D-CT and CE 4D-CT. In quantitative evaluations, the contrasts between the tumor and the normal pancreatic parenchyma were 0.6±23.4, −2.1±8.0, and −19.6±28.8 HU, in CE 3D-CT, 4D-CT, and CE 4D-CT, respectively. Although not statistically significant, CE 4D-CT achieved better contrast enhancement between the tumor and the normal pancreatic parenchyma than both CE 3D-CT and 4DCT. Conclusion: CE 4D-CT achieved equivalent image quality and better contrast enhancement between tumor and normal pancreatic parenchyma than the clinical standard of CE 3D-CT and 4D-CT. This study was supported in part by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

Calibration of a novel four-dimensional diode array

Purpose: The aim of this work is to develop effective calibration methods for a novel four-dimensional (4D) diode array for pretreatment verification of intensity-modulated radiation therapy (IMRT) and rotational therapy. Methods: A novel 4D diode array (ArcCHECK, Sun Nuclear, Melbourne, FL) was developed to meet the needs of appropriate and efficient quality assurance for IMRT and especially rotational radiotherapy. The diode array presents a consistent detector image in beam's eye view at arbitrary gantry angles due to isotropic arrangement of diodes in a three-dimensional (3D) cylindrical phantom. The 50 ms simultaneous update of all diodes on the detector array (fourth dimension) makes it capable of time-resolved beam delivery analysis with any rotational delivery techniques. The calibration procedure consisted of delivering and measuring a series of calibration beams with 5.8 deg. angular spacing surrounding the cylindrical diode array. Correction factors for diode intrinsic sensitivity and directional response dependence were derived from these measurements. A real-time algorithm to derive gantry angles based on the detector signal was developed to interpolate and apply the corresponding angular correction factors. Results: The calibration was validated with ion chamber scanned beam profiles in a 3D water tank. Excellent agreement was observed between diode array measurement and treatment planning system calculation. The accuracy of the gantry angle derivation algorithm was within 1 deg. which caused a less than 0.2% dosimetric uncertainty. Conclusions: With the proposed calibration method and the automatic gantry angle derivation algorithm, the 4D diode array achieved isotropic detector response and is suitable for both IMRT and rotational therapy pretreatment verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uncovering the three-dimensional structure of upconverting core–shell nanoparticles with multislice electron ptychography

In photon upconverting core–shell nanoparticles, structure strongly dictates performance. Typical imaging in scanning transmission electron microscopy has sufficient resolution to probe the atomic structure of these nanoparticles, but contrast, dose, and projection limitations make conventional methods insufficient for fully characterizing these structures. Phase retrieval techniques provide a promising alternative imaging mode, and, in particular, multislice electron ptychography can recover depth-dependent information. Here, we study beam-sensitive photon upconverting core–shell nanoparticles with a multislice ptychography approach using a low electron dose to avoid damage. Large strain fields arise in these heterostructures due to the mismatch in lattice parameter between the core and the shell. We reconstruct both a nanoparticle that appears defect-free and one that has a large break in the side and map the distribution of strain in 3D by computing distortion fields from high-resolution potential images of each slice. In the defect-free nanoparticle, we observe twisting of the shell, while in the broken nanoparticle, we measure the 3D position of the crack, the core, and dislocations. These results highlight the advantage of multislice electron ptychography to recover 3D information from a single scan, even under strict electron dose requirements from beam-sensitive samples.

74 ATOMIC AND MOLECULAR PHYSICS↗

The development and verification of a highly accurate collision prediction model for automated noncoplanar plan delivery

Purpose: Significant dosimetric benefits had been previously demonstrated in highly noncoplanar treatment plans. In this study, the authors developed and verified an individualized collision model for the purpose of delivering highly noncoplanar radiotherapy and tested the feasibility of total delivery automation with Varian TrueBeam developer mode. Methods: A hand-held 3D scanner was used to capture the surfaces of an anthropomorphic phantom and a human subject, which were positioned with a computer-aided design model of a TrueBeam machine to create a detailed virtual geometrical collision model. The collision model included gantry, collimator, and couch motion degrees of freedom. The accuracy of the 3D scanner was validated by scanning a rigid cubical phantom with known dimensions. The collision model was then validated by generating 300 linear accelerator orientations corresponding to 300 gantry-to-couch and gantry-to-phantom distances, and comparing the corresponding distance measurements to their corresponding models. The linear accelerator orientations reflected uniformly sampled noncoplanar beam angles to the head, lung, and prostate. The distance discrepancies between measurements on the physical and virtual systems were used to estimate treatment-site-specific safety buffer distances with 0.1%, 0.01%, and 0.001% probability of collision between the gantry and couch or phantom. Plans containing 20 noncoplanar beams to the brain, lung, and prostate optimized via an in-house noncoplanar radiotherapy platform were converted into XML script for automated delivery and the entire delivery was recorded and timed to demonstrate the feasibility of automated delivery. Results: The 3D scanner measured the dimension of the 14 cm cubic phantom within 0.5 mm. The maximal absolute discrepancy between machine and model measurements for gantry-to-couch and gantry-to-phantom was 0.95 and 2.97 cm, respectively. The reduced accuracy of gantry-to-phantom measurements was attributed to phantom setup errors due to the slightly deformable and flexible phantom extremities. The estimated site-specific safety buffer distance with 0.001% probability of collision for (gantry-to-couch, gantry-to-phantom) was (1.23 cm, 3.35 cm), (1.01 cm, 3.99 cm), and (2.19 cm, 5.73 cm) for treatment to the head, lung, and prostate, respectively. Automated delivery to all three treatment sites was completed in 15 min and collision free using a digital Linac. Conclusions: An individualized collision prediction model for the purpose of noncoplanar beam delivery was developed and verified. With the model, the study has demonstrated the feasibility of predicting deliverable beams for an individual patient and then guiding fully automated noncoplanar treatment delivery. This work motivates development of clinical workflows and quality assurance procedures to allow more extensive use and automation of noncoplanar beam geometries.

60 APPLIED LIFE SCIENCES↗

A comparative analysis of 3D conformal deep inspiratory–breath hold and free-breathing intensity-modulated radiation therapy for left-sided breast cancer

Patients undergoing radiation for left-sided breast cancer have increased rates of coronary artery disease. Free-breathing intensity-modulated radiation therapy (FB-IMRT) and 3-dimensional conformal deep inspiratory–breath hold (3D-DIBH) reduce cardiac irradiation. The purpose of this study is to compare the dose to organs at risk in FB-IMRT vs 3D-DIBH for patients with left-sided breast cancer. Ten patients with left-sided breast cancer had 2 computed tomography scans: free breathing and voluntary DIBH. Optimization of the IMRT plan was performed on the free-breathing scan using 6 noncoplanar tangential beams. The 3D-DIBH plan was optimized on the DIBH scan and used standard tangents. Mean volumes of the heart, the left anterior descending coronary artery (LAD), the total lung, and the right breast receiving 5% to 95% (5% increments) of the prescription dose were calculated. Mean volumes of the heart and the LAD were lower (p<0.05) in 3D-DIBH for volumes receiving 5% to 80% of the prescription dose for the heart and 5% for the LAD. Mean dose to the LAD and heart were lower in 3D-DIBH (p≤0.01). Mean volumes of the total lung were lower in FB-IMRT for dose levels 20% to 75% (p<0.05), but mean dose was not different. Mean volumes of the right breast were not different for any dose; however, mean dose was lower for 3D-DIBH (p = 0.04). 3D-DIBH is an alternative approach to FB-IMRT that provides a clinically equivalent treatment for patients with left-sided breast cancer while sparing organs at risk with increased ease of implementation.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-Band Radar for Studies of Tropical Storms from High Altitude UAV Platform

The increased role of unmanned aerial vehicles (UAV) in NASA's suborbital program has created a strong interest in the development of instruments with new capabilities, more compact sizes and reduced weights than the instruments currently operated on manned aircrafts. There is a strong demand and tremendous potential for using high altitude UAV (HUAV) to carry weather radars for measurements of reflectivity and wind fields from tropical storms. Tropical storm genesis frequently occurs in ocean regions that are inaccessible to piloted aircraft due to the long off shore range and the required periods of time to gather significant data. Important factors of interest for the study of hurricane genesis include surface winds, profiled winds, sea surface temperatures, precipitation, and boundary layer conditions. Current satellite precipitation and surface wind sensors have resolutions that are too large and revisit times that are too infrequent to study this problem. Furthermore, none of the spaceborne sensors measure winds within the storm itself. A dual beam X-band Doppler radar, UAV Radar (URAD), is under development at the NASA Goddard Space Flight Center for the study of tropical storms from HUAV platforms, such as a Global Hawk. X-band is the most desirable frequency for airborne weather radars since these can be built in a relatively compact size using off-the-shelf components which cost significantly less than other higher frequency radars. Furthermore, X-band radars provide good sensitivity with tolerable attenuation in storms. The low-cost and light-weight URAD will provide new capabilities for studying hurricane genesis by analyzing the vertical structure of tropical cyclones as well as 3D reflectivity and wind fields in clouds. It will enable us to measure both the 3D precipitation structure and surface winds by using two antenna beams: fixed nadir and conical scanning each produced by its associated subsystem. The nadir subsystem is a magnetron based radar modified from a marine radar transceiver. It is capable of measuring vertical reflectivity and velocity profile while being a lower-cost, smaller size, and lighter weight version of the NASA ER-2 Doppler Radar (EDOP), which has flown during many NASA field campaigns and has provided valuable scientific information on hurricanes and weather phenomena. Unfortunately, EDOP is too large and heavy for most UAV platforms, but the experience gained with this instrument provided us with the heritage to build a new low-cost, light-weight, smaller system that will be capable of flying on UAVs. The scanning subsystem uses a TWT transmitter and provides measurements of 3D reflectivity/wind fields in-clouds. Conical scanning of the radar beam at a 35 deg. incidence angle will also provide information of surface wind speed and direction derived from the surface return over a single 360 deg. sweep. URAD data system will be Linux based with the capability of autonomous operation. It will utilize cutting edge digital receiver and FPGA technologies to carry out the data acquisition and processing tasks. High speed navigation data from the aircraft will also be captured and saved along with radar data for 3D measurement field reconstruction and aircraft motion correction. There is a tremendous potential for UAVs to carry down-looking weather radars for measurements of reflectivity, horizontal and vertical winds from tropical storms. With operation from HUAV platforms, the dual beam X-band radar under development promises to provide greatly needed information for tropical storm research.

Rodriquez, Shannon↗

LaserOrigami (LO) of three-dimensional (3D) components: Experimental analysis and numerical modeling-part II

The present work explores how the choice of the scanning patterns can affect the final shapes of 3D components manufactured by laser-origami with a High-Power Diode Laser (HPDL). The experimental approach allowed the achievement of high bending angles, also avoiding any distortion on the surface of AISI 304 stainless steel workpiece. Optimization of the operational parameters led to the best prototype of the 3D components, with the closest respect of the strictest dimensional and geometrical tolerances. In addition, a thermo-mechanical model to predict the final shape of the 3D components was developed. The numerical model, implemented by Finite Element Method (FEM), was discovered to be a reliable tool in predicting the final shape of the prototypes, matching with a great deal of accuracy the experimental results. Specifically, the model allowed the estimation of the temperature distribution and nodal displacements of the components varying both the setting of the laser parameters and the choice of the scanning patterns.

47 OTHER INSTRUMENTATION↗

SU-E-U-02: The Development of a Practical Ultrasonic System for Cross-Sectional Imaging of Small Animals

Purpose: To test the feasibility of developing a practical medium frequency ultrasound tomography method for small animal imaging. The ability to produce cross-sectional or full body images of a live small animal using a low-cost tabletop ultrasound scanner without any special license would be very beneficial to long term biological studies, where repeated scanning is often required over an extended period of time. Methods: The cross sectional images were produced by compounding multiple B-scans of a laboratory phantom or an animal acquired at different projection angles. Two imaging systems were used to test the concept. The first system included a programmable 64-channel phased array controller driving a 128-channel, 5–10 MHz linear probe to produce 143 B-Mode projections of the spinning object. The second system designed and manufactured in house, produced 64 or 128 B-Mode projections with a single unfocused 8 MHz transducer scanning with a 0.116 mm step size. Results: The phased array system provided good penetration through the phantoms/mice (with the exception of the lungs) and allowed to acquire data in a very short time. The cross-sectional images have enough resolution and dynamic range to detect both high- and low-contrast organs. The single transducer system takes longer to scan, and the data require more sophisticated processing. To date, our images allow seeing details as small as 1–2 mm in the phantoms and in small animals, with the contrast mostly due to highly reflecting bones and air inclusions. Conclusion: The work indicates that very detailed and anatomically correct images can be created by relatively simple and inexpensive means. With more advanced algorithms and improved system design, scan time can be reduced considerably, enabling high-resolution full 3D imaging. This will allow for quick and easy scans that can help monitor tumor growth and/or regression without contributing any dose to the animal. The authors would like to acknowledge the financial and engineering support from Tessonics.

60 APPLIED LIFE SCIENCES↗

Automated correlative segmentation of large Transmission X-ray Microscopy (TXM) tomograms using deep learning

Highlights: • A unique automated segmentation approach for large 3D nanotomography datasets obtained by Transmission X-ray Microscopy (TXM) in an Al-Cu alloy. • Automated segmentation using a Convolutional Neural Network (CNN) architecture based on a deep learning approach was employed. • This extremely versatile technique is capable of emulating the manual segmentation process effectively. • Quantitative comparison between manual segmentation and CNN architecture established the accuracy of this automated technique. • Its ability to robustly process ultra-large volumes of data in relatively small time frames can exponentially accelerate tomographic data analysis. - Abstract: A unique correlative approach for automated segmentation of large 3D nanotomography datasets obtained using Transmission X-ray Microscopy (TXM) in an Al-Cu alloy has been introduced. Automated segmentation using a Convolutional Neural Network (CNN) architecture based on a deep learning approach was employed. This extremely versatile technique is capable of emulating the manual segmentation process effectively. Coupling this technique with post-scanning SEM imaging ensured precise estimation of 3D morphological parameters from nanotomography. The segmentation process as well as subsequent analysis was expedited by several orders of magnitude. Quantitative comparison between segmentation performed manually and using the CNN architecture established the accuracy of this automated technique. Its ability to robustly process ultra-large volumes of data in relatively small time frames can exponentially accelerate tomographic data analysis, possibly opening up novel avenues for performing 4D characterization experiments with finer time steps.

36 MATERIALS SCIENCE↗

Assessment of a tomography-informed polyhedral discrete element modelling approach for complex-shaped granular woody biomass in stress consolidation

The design of handling equipment for granular biomass primarily requires experiments. Discrete element models (DEM) can provide designers with detailed insight into the behaviour of granular materials. However, granular biomass comprising complex-shaped particles is difficult to model with DEM. A tomography-informed DEM approach and an exhaustive assessment of the ability of the approach to predict the bulk behaviour of milled pines using experimental data is presented. Nano-CT scan was conducted to obtain 3D particle surface geometries as the basis for particle shape approximation by a polyhedral model and a sphero-polyhedral model. These models were applied in the simulation of a compressibility test. Our parametric study showed that particle Young's modulus and restitution coefficient are the two main properties influencing the simulated bulk behaviour of the DEM particles and that the level of approximating DEM particle shape for real particles is critical for accurately replicating the bulk behaviour of milled pines. The polyhedral model demonstrated better suitability than its sphero-polyhedral counterpart for modelling pine particles. The polyhedral model calibrated in a compressibility test was then applied in the simulations of a friction test without additional parameter tuning. Interlocking was dominant in the shear of bulk pine particles. Remarkably, the polyhedral model predicted the frictional behaviour of the pine particles when compared to the experimental results. The limitations of the model, as well as possible ways for enhancement, are discussed. This work provided novel insights into the suitability of complex-shaped DEM models for granular woody biomass.

Biomass flow↗

Correlative STEM-APT characterization of radiation-induced segregation and precipitation of in-service BWR 304 stainless steel

In this study, radiation induced segregation and precipitation phenomena in an in-service boiling water reactor 304 stainless steel component were investigated using directly correlated 3D-atom probe tomography and scanning transmission electron microscopy. Significant quantitative differences in measured segregation at grain boundaries were found between the atom probe and energy dispersive spectroscopy measurements of the exact same locations. In particular, a much stronger Si segregation (~10 atomic% via atom probe versus ~4 atomic% via electron microscopy) and different Cr profile shapes were detected that are critical to models of radiation induced segregation and stress corrosion cracking behavior. These quantitative differences highlight the need for comparative microscopy and critical evaluation of limitations in each analytical method. Elemental segregation to dislocations and conjoined-clusters were also highlighted by atom probe; confirming and expanding upon what has been observed in test reactor neutron and accelerator-based ion irradiations.

36 MATERIALS SCIENCE↗

Thermal cycling-driven microstructural changes of eutectic Al–Si phase change materials in SS304 containers revealed by multi-modal imaging

Aluminum-based Al–Si alloys are widely used as phase change materials (PCMs) in thermal energy storage (TES) systems owing to their high volumetric latent heat and superior thermal conductivity. However, their long-term reliability is limited by degradation processes that remain insufficiently understood. In this work, we employ a multimodal, correlative characterization framework to systematically resolve the degradation behavior of eutectic Al–Si PCMs in contact with SS304 containers under repeated thermal cycling. By integrating high-resolution electron microscopy, three-dimensional X-ray fluorescence (3D XRF) imaging, and differential scanning calorimetry (DSC), we directly link spatially resolved compositional and microstructural evolution to changes in thermophysical properties. The correlative analysis reveals that elemental leaching of Fe, Cr, and Ni from the stainless-steel container into the PCM drives the formation of intermetallic compounds (IMCs) both at the interface and within the bulk PCM, leading to pronounced compositional heterogeneity. These interfacial reactions and diffusion-induced transformations progressively destabilize the Al–Si eutectic, reducing the effective phase-transforming fraction. Consistent with these observations, DSC measurements show a decrease in melting temperature and latent heat of fusion with thermal cycling. These results underscore the critical influence of interfacial reactions and material compatibility on the stability, durability, and overall performance of Al–Si-based TES systems.

25 ENERGY STORAGE↗