Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “visible light”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Regulated bioluminescence as a tool for bioremediation process monitoring and control of bacterial cultures

An effective on-line monitoring technique for toxic waste bioremediation using bioluminescent microorganisms has shown great potential for the description and optimization of biological processes. The lux genes of the bacterium Vibrio fischeri are used by this species to produce visible light. The lux genes can be genetically fused to the control region of a catabolic gene, with the result that bioluminescence is produced whenever the catabolic gene is induced. Thus the detection of light from a sample indicates that genetic expression from a specific gene is occurring. This technique was used to monitor biodegradation of specific contaminants from waste sites. For these studies, fusions between the lux genes and the operons for naphthalene and toluene/xylene degradation were constructed. Strains carrying one of these fusions respond sensitively and specifically to target substrates. Bioluminescence from these cultures can be rapidly measured in a nondestructive and noninvasive manner. The potential for this technique in this and other biological systems is discussed.

Burlage, Robert S.↗

Laser discrimination by stimulated emission of a phosphor

A method for discriminating sources of UV, near infrared, and far infrared laser radiation was discovered. This technology is based on the use of a single magnesium sulfide phosphor doubly doped with rare earth ions, which is thermally/optically stimulated to generate colors correlatable to the incident laser radiation. The phosphor, after initial charging by visible light, exhibits green stimulated luminescence when exposed to a near infrared source (Nd: YAG laser). On exposure to far infrared sources (CO2 laser) the phosphor emission changes to orange color. A UV laser produces both an orange red as well as green color. A device using this phosphor is useful for detecting the laser and for discriminating between the near infrared, far infrared, and UV lasers. The technology is also capable of infrared laser diode beam profiling since the radiation source leaves an imprint on the phosphor that can be photographed. Continued development of the technology offers potential for discrimination between even smaller bandwidths within the infrared spectrum, a possible aid to communication or wavemixing devices that need to rapidly identify and process optical signals.

Mathur, V. K.↗

Calculated sensitivities of several optical radiometric indices for vegetation canopies

The present study employs a radiative transfer model for a vegetation canopy to compute several quantities used in remote sensing applications and to determine the sensitivity of these radiometric quantities to several of the important problem parameters. Attention is given to the ratio of near IR to visible reflected intensities in the nadir direction, the ratio of the fraction of incident energy reflected in the near IR to that in the visible, the normalized difference between the near IR and visible nadir-reflected intensities, and the visible intensity transmitted in a given downward direction. A realistic radiative transfer model is proposed for calculating these radiometric quantities. With these models, the sensitivity of the reflected and transmitted quantities to various canopy and illumination conditions are then determined. The sensitivity of the calculated quantities are presented as a function of the leaf area index of the canopy, and, for the reflected quantities, also as a function of the fraction of visible light absorbed in the canopy.

Shultis, J. K.↗

Performance of the Multi-Spectral Solar Telescope Array. III - Optical characteristics of the Ritchey-Chretien and Cassegrain telescopes

The Multi-Spectral Solar Telescope Array (MSSTA), which is a sounding-rocket-borne observatory for investigating the sun in the soft X-ray/EUV and FUV regimes of the electromagnetic spectrum, utilizes single reflection multilayer coated Herschelian telescopes for wavelengths below 100 A, and five doubly reflecting multilayer coated Ritchey-Chretien and two Cassegrain telescopes for selected wavelengths in the EUV region between 100 and 1000 A. The paper discusses the interferometric alignment, testing, focusing, visible light testing, and optical performance characteristics of the Ritchey-Chretien and Cassegrain telescopes of MSSTA. A schematic diagram of the MSSTA Ritchey-Chretien telescope is presented together with diagrams of the system autocollimation testing.

Hoover, Richard B.↗

Design of narrow band XUV and EUV coronagraphs using multilayer optics

A novel approach to the study of the solar corona is described, which enables observation of the soft X-ray (XUV), EUV, and FUV emission of the highly ionized ions present in the corona. The principal advantage of this approach is a relatively low contrast between the innner corona and the solar disk at the wavelengths involved; the contrast between coronal visible light and the XUV or EUV light is about 1. The design and the anticipated performances of the XUV and EUV coronagraphs using normal incidence multilayer optics are described.

Walker, A. B. C., Jr.↗

A new solar irradiance calibration from 3295 A to 8500 A derived from absolute spectrophotometry of Vega

By imaging sunlight diffracted by 20- and 30-micron diameter pinholes onto the entrance aperture of a photoelectric grating scanner, the solar spectral irradiance was determined relative to the spectrophotometric standard star Vega, observed at night with the same instrument. Solar irradiances are tabulated at 4 A increments from 3295 A to 8500 A. Over most of the visible spectrum, the internal error of measurement is less than 2 percent. This calibration is compared with earlier irradiance measurements by Neckel and Labs (1984) and by Arvesen et al. (1969) and with the high-resolution solar atlas by Kurucz et al. The three calibrations agree well in visible light but differ by as much as 10 percent in the ultraviolet.

Lockwood, G. W.↗

Space optics for studying extra-solar planetary systems

The sharp imaging of telescopes in space will improve the ability to see faint objects near bright ones. One exciting application is the search for planets around other stars. However, because a planet is, at best, 10 exp 9 times fainter than a star in visible light, specialized optical systems are required. Using apodization to remove diffracted light, the limiting source of noise is the intensity of starlight scattered by mirror figure errors. Based on the prelaunch metrology of the HST mirrors, and considering only photonstatistics, months of integration would be needed for HST to detect Jupiter next to the sun at a distance of 5 pc. The integration times will be shorter for future telescopes in space with smoother mirrors and/or larger apertures.

Brown, Robert A.↗

Micro-precision control/structure interaction technology for large optical space systems

The CSI program at JPL is chartered to develop the structures and control technology needed for sub-micron level stabilization of future optical space systems. The extreme dimensional stability required for such systems derives from the need to maintain the alignment and figure of critical optical elements to a small fraction (typically 1/20th to 1/50th) of the wavelength of detected radiation. The wavelength is about 0.5 micron for visible light and 0.1 micron for ultra-violet light. This lambda/50 requirement is common to a broad class of optical systems including filled aperture telescopes (with monolithic or segmented primary mirrors), sparse aperture telescopes, and optical interferometers. The challenge for CSI arises when such systems become large, with spatially distributed optical elements mounted on a lightweight, flexible structure. In order to better understand the requirements for micro-precision CSI technology, a representative future optical system was identified and developed as an analytical testbed for CSI concepts and approaches. An optical interferometer was selected as a stressing example of the relevant mission class. The system that emerged was termed the Focus Mission Interferometer (FMI). This paper will describe the multi-layer control architecture used to address the FMI's nanometer level stabilization requirements. In addition the paper will discuss on-going and planned experimental work aimed at demonstrating that multi-layer CSI can work in practice in the relevant performance regime.

Sirlin, Samuel W.↗

Modulation transfer function measurement technique for small-pixel detectors

A modulation transfer function (MTF) measurement technique suitable for large-format, small-pixel detector characterization has been investigated. A volume interference grating is used as a test image instead of the bar or sine wave target images normally used. This technique permits a high-contrast, large-area, sinusoidal intensity distribution to illuminate the device being tested, avoiding the need to deconvolve raw data with imaging system characteristics. A high-confidence MTF result at spatial frequencies near 200 cycles/mm is obtained. We present results at several visible light wavelengths with a 6.8-micron-pixel CCD. Pixel response functions are derived from the MTF results.

Marchywka, Mike↗

Measurements of an intensified CCD detector for the Solar and Heliospheric Observatory

An engineering model intensified CCD detector for the SOHO Coronal Diagnostics Spectrometer has been built and tested at the NASA Goddard Space Flight Center. A windowless MCP intensifier tube converts EUV radiation (30-65 nm) into visible light, which is focused via a lens system onto a Tektronix 1024 x 1024 CCD. Tests have been made of this engineering model to determine the following characteristics: quantum efficiency, resolution, throughput, linearity, statistical variation, readout noise, scattering, and flat-field response. In almost all respects, the detector performed as expected. This detector has been delivered, and work is underway on the flight detector.

Thompson, William T.↗

Imaging Schwarzschild multilayer X-ray microscope

We have designed, analyzed, fabricated, and tested Schwarzschild multilayer X-ray microscopes. These instruments use flow-polished Zerodur mirror substrates which have been coated with multilayers optimized for maximum reflectivity at normal incidence at 135 A. They are being developed as prototypes for the Water Window Imaging X-Ray Microscope. Ultrasmooth mirror sets of hemlite grade sapphire have been fabricated and they are now being coated with multilayers to reflect soft X-rays at 38 A, within the biologically important 'water window'. In this paper, we discuss the fabrication of the microscope optics and structural components as well as the mounting of the optics and assembly of the microscopes. We also describe the optical alignment, interferometric and visible light testing of the microscopes, present interferometrically measured performance data, and provide the first results of optical imaging tests.

Hoover, Richard B.↗

The Soft X-ray Telescope for Solar-A - Design evolution and lessons learned

The Japanese Solar-A satellite mission's Soft X-ray Telescope uses grazing-incidence optics, a CCD detector, and a pair of filter wheels for wavelength selection. A coaxially-mounted visible-light lens furnished sunspot and magnetic plage images, together with aspect information which aids in aligning the soft X-ray images with those from the satellite's Hard X-ray Telescope. Instrument electronics are microprocessor-based, and imbedded in a tightly integrated distributed system. Control software is divided between the instrument microprocessor and the spacecraft control computer.

Bruner, Marilyn E.↗

Making Diamondlike Films More Transparent

Diamondlike carbon films highly transparent to visible light made by dual-ion-beam deposition process. Hard, resistant to scratching, and hermetic. Used as protective coatings on eyeglasses, magnetic recording heads, computer hard disks, and windows in bar-code scanners. Amorphous diamondlike carbon films preferable to polycrystalline diamond films in these and other applications. Smooth and adherent and deposited at room temperature.

Mirtich, Michael J.↗

Selective formation of porous silicon

A pattern of porous silicon is produced in the surface of a silicon substrate by forming a pattern of crystal defects in said surface, preferably by applying an ion milling beam through openings in a photoresist layer to the surface, and then exposing said surface to a stain etchant, such as HF:HNO3:H20. The defected crystal will preferentially etch to form a pattern of porous silicon. When the amorphous content of the porous silicon exceeds 70 percent, the porous silicon pattern emits visible light at room temperature.

Fathauer, Jones↗

Extra-corporeal blood access, sensing, and radiation methods and apparatuses

The described invention is related to extra-corporeal blood access and radiation methods and apparatuses and, in particular, to subjecting flowing blood to energy in variety of forms, including radiation, electromagnetic force fields or atomic particles. It is directed to methods and apparatuses for accessing flowing blood and for subjecting the blood to electrical conductive, electrostatic or electromagnetic fields or for radiating the blood with some type of radiation, e.g., radio waves, ultrasonic or audio waves, microwaves, IR rays, visible light, UV radiation, x-rays, alpha, beta or gamma rays. An apparatus is employed which includes one or more access ports or windows for radiating blood and/or for sensing/analyzing blood. This invention is useful for killing viruses and bacteria in blood, monitoring blood for medical purposes, genetic modification of blood, and analyzing and/or treating blood components.

Castle, Kent D.↗

Relativistic shock spectra: A prediction

I argue that particles heated by relativistic shocks should assume an equilibrium energy distribution. This leads to a synchrotron spectrum F(sub nu) varies as nu(sup 1/3) up to approximately the critical frequency nu(sub 0) of an electron with the mean electron energy. Application to gamma ray bursts (GRB's) implies that a burst with 10(exp -5) erg/(sq cm s) of soft gamma-rays and h(nu(sub 0)) = 300 KeV should be about 18th magnitude in visible light and a few micro-Jy at 1 GHz (less if self-absorbed).

Katz, J. I.↗

Special test equipment and fixturing for MSAT reflector assembly alignment

The MSAT Reflector Assembly is a state of the art subsystem for Mobile Satellite (MSAT), a geosynchronous-based commercial mobile telecommunication satellite program serving North America. The Reflector Assembly consisted of a deployable, three-hinge, folding-segment Boom, deployable 5.7 x 5.3-meter 16-rib Wrap-Rib Reflector, and a Reflector Pointing Mechanism (RPM). The MSAT spacecraft was based on a Hughes HS601 spacecraft bus carrying two Reflector Assemblies independently dedicated for L-band transmit and receive operations. Lockheed Missiles and Space Company (LMSC) designed and built the Reflector Assembly for MSAT under contract to SPAR Aerospace Ltd. Two MSAT satellites were built jointly by SPAR Aerospace Ltd. and Hughes Space and Communications Co. for this program, the first scheduled for launch in 1994. When scaled for wavelength, the assembly and alignment requirements for the Reflector Assembly were in many instances equivalent to or exceeded that of a diffraction-limited visible light optical system. Combined with logistical constraints inherent to large, compliant, lightweight structures; 'bolt-on' alignment; and remote, indirect spacecraft access; the technical challenges were formidable. This document describes the alignment methods, the special test equipment, and fixturing for Reflector Assembly assembly and alignment.

Young, Jeffrey A.↗

Long-term variations in dust production in R Coronae Borealis

Several searches for periodicities in the historical visible light curves of RCB stars have found that the intervals between declines are random. This paper reexamines 70 declines of R Coronae Borealis since 1853 using one homogeneous data set, the AAVSO light curve. In this data set, pairs of consecutive declines also show a random distribution of intervals. However, if the sequence of declines is examined, there are semiperiodic variations between times of high- and low-decline activity on a time scale of a few years. Near-IR photometry of RCB stars indicates that there are large semiperiodic variations in the amount of dust being produced which have similar time scales. Possible interpretations of a semiperiodic variation in dust formation rates in RCB stars are presented. One is a magnetic activity cycle resulting in 'spots' on the star over which dust formation takes place. Such a magnetic activity cycle is similar to the solar cycle. Another is the changes in the period and amplitude of the pulsations over several years affecting the efficiency of dust production.

Clayton, Geoffrey C.↗