Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ventilation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Pattern of filling in the pulmonary capillary bed.

Artificially ventilated and perfused dog lungs were rapidly frozen under various physiological conditions. In 2-micron-thick sections the number of red blood cells (RBCs) per 10-micron length of alveolar septum was counted. Under conditions in which alveolar pressure exceeded venous pressure, variation in RBC concentration within areas supplied by single arterioles accounted completely for variation between areas supplied by different arterioles. Except at very high perfusion pressures when venous pressure exceeded alveolar pressure, there was no significant correlation between RBC concentrations of pairs of adjacent septa.

Warrell, D. A.↗

Effects of diffusion impairment on O2 and CO2 time courses in pulmonary capillaries.

Simultaneous time courses for O2 and CO2 exchange along the capillary have been calculated for homogeneous lungs, allowing for O2-CO2 interactions, dissolved O2, and chemical reaction rates. As diffusing capacity (Dl) was reduced, the transfer of CO2 and O2 was impaired by similar amounts, in spite of the 20-fold greater diffusing capacity for CO2. The reason why CO2 is affected so much is that the slope of the content against partial pressure is so much greater in blood than tissue for this gas. Because of the shapes of their respective dissociation curves, O2 transfer was most affected at normal ventilation-perfusion ratios, whereas CO2 was most affected at high ratios. Exercise exaggerated the impairment of transfer of both gases.

Wagner, P. D.↗

Mixing-height measurement by lidar, particle counter, and rawinsonde in the Williamette Valley, Oregon

The feasibility of using laser radar (lidar) to measure the spatial distribution of aerosols and water vapor in the earth's mixing or boundary layer is shown. From these data the important parameter of actual mixing height was determined, that is, the maximum height to which particulate pollutants actually mix. Data are shown for simultaneous lidar, rawinsonde, and aircraft-mounted condensation nuclei counter and temperature measurements. The synoptic meteorology is also presented. The Williamette Valley, Oregon, was chosen for the measurements because of its unique combination of meteorology, terrain, and pollutant source, along with an ongoing Oregon State University study of the natural ventilation of this valley.

Mccormick, M. P.↗

Operating Room Environment Control. Part A: a Valve Cannister System for Anesthetic Gas Adsorption. Part B: a State-of-the-art Survey of Laminar Flow Operating Rooms. Part C: Three Laminar Flow Experiments

An anesthetic gas flow pop-off valve canister is described that is airtight and permits the patient to breath freely. Once its release mechanism is activated, the exhaust gases are collected at a hose adapter and passed through activated coal for adsorption. A survey of laminar air flow clean rooms is presented and the installation of laminar cross flow air systems in operating rooms is recommended. Laminar flow ventilation experiments determine drying period evaporation rates for chicken intestines, sponges, and sections of pig stomach.

Meyer, J. S.↗

Underwater space suit pressure control regulator

A device is reported for regulating the pneumatic pressure in a ventilated space suit relative to the pressure imposed on the suit when being worn by a person underwater to simulate space environment for testing and experimentation. A box unit located on the chest area of the suit comprises connections for suit air supply and return lines and carries a regulator valve that stabilizes the air pressure differential between the inside and outside of the suit. The valve and suit pressure is controlled by the suit occupant and the valve includes a mechanism for quickly dumping the suit pressure in case of emergency. Pressure monitoring and relief devices are also included in the box unit.

Aldrich, B. R.↗

VICS-120 - A tube-vehicle system test facility.

Description of a large test facility for carrying out research in support of the aerodynamic and ventilation section of a handbook on subway design. The facility described is vertically oriented and has a test section with a nominal inside diameter of 2 in. and a length of 109 ft. It is capable of operating at Reynolds numbers up to full-scale (60,000,000) under open-end tube conditions. The facility is distinguished by a high degree of flexibility in configuration and operational limits. Details are given concerning the plenum assembly, the test section tubes, the scaffold, the instrumentation, the model launcher, the model arrestor, and the models themselves. A step-by-step account is given of the operation of the facility, and a brief sample of the type of data obtained from the facility is presented.

Marte, J. E.↗

Effects of oxygen-augmented atmosphere on the immune response.

Antibovine serum albumin antibody and nonspecific protein production was evaluated in female rabbits (11-14.5 kg) housed in special cages ventilated with 20% or 40% oxygen at normal barometric pressure. Animals exposed to 40% oxygen do not show normal steady increase of serum antibody. Instead, their titers show a pattern of undershoot, overshoot, undershoot, and finally equilibration at a subnormal level; they have a depressed popliteal node polysome level and have an abnormally low proportion of membrane-bound polysomes. They also show reduced capability of popliteal nodes to synthesize protein (as expected from the reduced number of polysomes). However, the ratio of newly-synthesized specific antibody: nonspecific protein remains normal.

Guttman, H. N.↗

A monkey metabolism pod for space-flight weightlessness studies.

The system described will permit quantitative physiological studies in adult monkeys, weighing from 8 to 14 kg, during future space flights. The system comprises a fiberglass pod containing a comfortable restraint couch for the animal. The pod is divided into upper and lower halves. When the monkey occupies the couch, a rubber belly-band forms a gas seal between the upper and lower portions of the animal. The upper-pod ventilating air stream is monitored for the partial pressures of oxygen, carbon dioxide, nitrogen, and water to permit continuous metabolic gas-exchange measurements for computation of metabolic energy expediture. The lower pod is lined with ashless filter paper for excreta collection.

Pace, N.↗

Vertical axis wind rotors: Status and potential

The design and application of a vertical axis wind rotor is reported that operates as a two stage turbine wherein the wind impinging on the concave side is circulated through the center of the rotor to the back of the convex side, thus decreasing what might otherwise be a high negative pressure region. Successful applications of this wind rotor to water pumps, ship propulsion, and building ventilators are reported. Also shown is the feasibility of using the energy in ocean waves to drive the rotor. An analysis of the impact of rotor aspect ratio on rotor acceleration shows that the amount of venting between rotor vanes has a very significant effect on rotor speed for a given wind speed.

Vance, W.↗

Calculation method for active silencers with a variable section

By introducing variable section silencers in divergent and convergent sections or elbows of ventilation plants, the length of classical silencers can be reduced. Presented is an original calculation method for active noise silencers with a continuously variable section, as well as calculation relations worked out by this method for eight common practical cases.

Marinescu, V.↗

Some tunnel-wall effects on transonic flutter

Significant effects of wind-tunnel walls were observed on the transonic flutter boundaries of wall-mounted models during two flutter model research studies. In these studies, flutter experiments with cantilevered SST-type wing models were conducted in three different wind tunnels. The experimental results are compared to flutter boundaries calculated for the models in free air. The results indicate that transonic flutter boundaries can be affected by tunnel-wall interference, tunnel resonances, and shock-wave reflections, and that flutter model data accuracy is a function of model/tunnel size and tunnel wall porosity. However, models within the recommended size limits should give accurate results in transonic tunnels with normal ventilation. A flutter trend analysis for a two-dimensional wing-demonstrating tunnel wall and resonance effects on flutter are also presented.

Ruhlin, C. L.↗

Respiration, respiratory metabolism and energy consumption under weightless conditions

Changes in the physiological indices of respiration, respiratory metabolism and energy consumption in spacecrews under weightlessness conditions manifest themselves in increased metabolic rates, higher pulmonary ventilation volume, oxygen consumption and carbon dioxide elimination, energy consumption levels in proportion to reduction in neuroemotional and psychic stress, adaptation to weightlessness and work-rest cycles, and finally in a relative stabilization of metabolic processes due to hemodynamic shifts.

Kasyan, I. I.↗

Analysis of effect of the solubility on gas exchange in nonhomogeneous lungs

A comparison is made of the gas exchange in nonhomogeneous lung models and in homogeneous lung models with the same total blood flow and ventilation. It is shown that the ratio of the rate of gas transfer of the inhomogeneous lung model over the rate of gas transfer of the homogeneous lung model as a function of gas solubility always has the qualitative features for gases with linear dissociation curves. This ratio is 1 for a gas with zero solubility and decreases to a single minimum. It subsequently rises to approach 1 as the solubility tends to infinity. The early portion of the graph of this function is convex, then after a single inflection point it is concave.

Colburn, W. E., Jr.↗

The MIST /MIUS Integration and Subsystems Test/ laboratory - A testbed for the MIUS /Modular Integrated Utility System/ program

The MIUS (Modular Integrated Utility System) concept is to be an energy-conserving, economically feasible, integrated community utility system to provide five necessary services: electricity generation, space heating and air conditioning, solid waste processing, liquid waste processing, and residential water purification. The MIST (MIUS Integration and Subsystem Test) integrated system testbed constructed at the Johnson Space Center in Houston includes subsystems for power generation, heating, ventilation, and air conditioning (HVAC), wastewater management, solid waste management, and control and monitoring. The key design issues under study include thermal integration and distribution techniques, thermal storage, integration of subsystems controls and displays, incinerator performance, effluent characteristics, and odor control.

Beckham, W. S., Jr.↗

Fluctuations in O2 stores and gas exchange with passive changes in posture

The purpose of the present study is to determine the effects of changes in posture on oxygen transfer at the mouth and pulmonary capillary membrane and to observe concomitant subtle changes in ventilation under specified assumptions. Breath-by-breath calculations are carried out with a box-balloon spirometer and mass spectrometer. Measurements are made before, during, and after passive tilt to 60 deg and on return to recumbency after 10 min erect. It is found that from supine to upright oxygen stores in the lung increases rapidly and oxygen stores in the blood drops slowly, creating a net deficit in oxygen transfer at the mouth of 130 ml in 10 min. Changes in oxygen stores in the blood result from shifts in blood volume and flow more than from changes in cardiac output. Refilling of oxygen stores in the blood is found to cause transient hypoxia with substantial hyperpnea.

Loeppky, J. A.↗

Velocity sensor for slow flows

Inexpensive, easily-constructed device measures flows from 0.2 to 20 feet per second. Instrument is capable of measuring flow velocity and direction in cases where either velocity or density is so low that dynamic pressure is below measurable range. It can be made into hand held instrument for measuring ventilation and air conditioning flow.

Simon, W. E.↗

Technology Utilization House Study Report

The objectives of Project TECH are: (1) to construct a single family detached dwelling for demonstrating the application of advanced technology and minimizing the requirement for energy and utility services, and (2) to help influence future development in home construction by defining the interaction of integrated energy and water management systems with building configuration and construction materials. Components and methods expected to be cost effective over a 20 year span were studied. Emphasis was placed on the utilization of natural heating and cooling characteristics. Orientation and location of windows, landscaping, natural ventilation, and characteristics of the local climate and microclimate were intended to be used to best advantage. Energy conserving homes are most efficient when design for specific sites, therefore project TECH should not be considered a prototype design suitable for all locations. However, it does provide ideas and analytical methods which can be applied to some degree in all housing.

Source record↗