Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Collisional Effects on Electron Trajectories in Crossed-Field Devices

Crossed-field diodes (CFDs) are used in multiple high-power applications and are characterized by an applied magnetic field orthogonal to the electric field, induced by the applied voltage across the anode-cathode gap. In vacuum, the Hull cutoff magnetic field (HCMF) represents the maximum applied magnetic field for which an electron from the cathode can reach the anode. This study investigates the effects of non-vacuum conditions on electron trajectories by introducing electron mobility, which represents particle collisions. We used numerical solutions of the electron force law and particle-in-cell simulations (XPDP1) to assess electron motion for various electron mobilities. For magnetic fields above the HCMF in vacuum, reducing the electron mobility increases the time for an electron emitted from the cathode to reach the anode. Reducing mobility below 22 C s/kg eliminates the HCMF for any magnetic field, meaning that an emitted electron will always cross the gap. We derived the magnetic field, mobility, and electron transit time corresponding to this condition by solving for the condition when the electron velocity in the direction across the anode-cathode gap going to zero at the anode. A parametric study of these conditions using theory and XPDP1 is performed under different gap distances, voltages, and magnetic fields.

42 ENGINEERING↗

Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development

Introduction: This paper describes the progress in data acquisition and establishing the observational capability of the AEXS instrument. The AEXS is a miniature instrument[1-4] based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam which enables nondestructive evaluation of sample surfaces in planetary ambient atmospheres. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum of the AEXS source from the outside ambient atmosphere. Thus eliminating the need for a vacuum pumped sample chamber as is common in all laboratory SEM s. The transmitted electrons impinge on the sample exciting XRF spectra from the irradiated spot on in-situ or collected samples with sub-mm to cm-scale spatial resolution at Mars atmospheric pressure. The AEXS system (Fig 1) consists of a high-energy (>10keV) electron gun encapsulated by the isolation membrane, an XRF detection and analyzer system, and a high voltage power supply. The XRF data are analyzed to determine the elemental abundance for the irradiated spots. The approach to demonstrating a proof of concept of the AEXS has been through 1) demonstrating the viability of microfabricated membranes, 2) assembling AEXS setups with increasingly integrated functional components, and 3) simulating the AEXS observational capabilities. The development of the instrument is described in detail in the poster paper[4] at this conference. This paper focuses on describing the progress of the AEXS instrument to acquire XRF data and using commercially available software to analyze the data streams and determine the accuracy, precision and resolution of the analysis compared to the certified elemental abundance.

Urgiles, E.↗

Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development

Instrument Development: The membrane properties were investigated in detail due to its critical role. A series of experiments determined that our designed membranes have high electron transmission, yet are capable of isolating high vacuum, are able to withstand differential pressure in excess of one atmosphere, survive vibrational shocks of a magnitude to be expected during a planetary mission. Our initial work has been with a 10 keV source and a 200 nm thick Silicon Nitride (SiN) encapsulation membrane micro-fabricated within a Si support frame (1.5 mm x 1.5 mm window openings. Fig 2 compares the spectra taken with the 10 keV source with spectra taken within SEM. Introduction: This paper describes the progress in the development of the AEXS instrument in our laboratory at JPL. The AEXS is a novel miniature instrument[1-3] based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam, for non-destructive evaluation of surfaces of samples in planetary ambient atmosphere. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum within the AEXS electron source from the outside ambient atmosphere. The impinging electrons excite XRF spectra from the irradiated spots on samples in external atmosphere with high-to-medium (sub-mm to cm-scale) spatial resolution at Mars atmospheric pressure. The XRF spectra are analyzed using an energy-dispersive detector to determine surface elemental composition, or in the case of electron-induced luminescence to identify unusual formations on surface that cathodo-luminescence (CL). The AEXS system (Fig 1) consists of a high-energy (>10keV) electron gun encapsulated by the isolation membrane, an EDX detection and analyzer system to determine the elemental abundance, an optional CL detection system, and a high voltage power supply. The approach to demonstrating a proof of concept of the AEXS has been through 1) demonstrating the viability of micro-fabricated membranes, 2) assembling AEXS setups with increasingly integrated functional components, and 3) simulating the AEXS observational capabilities. This paper will focus on description of the development of the instrument.

Wilcox, J. Z.↗

Innovative Electrostatic Adhesion Technologies

Developing specialized Electro-Static grippers (commercially used in Semiconductor Manufacturing and in package handling) will allow gentle and secure Capture, Soft Docking, and Handling of a wide variety of materials and shapes (such as upper-stages, satellites, arrays, and possibly asteroids) without requiring physical features or cavities for a pincher or probe or using harpoons or nets. Combined with new rigid boom mechanisms or small agile chaser vehicles, flexible, high speed Electro-Static Grippers can enable compliant capture of spinning objects starting from a safe stand-off distance. Electroadhesion (EA) can enable lightweight, ultra-low-power, compliant attachment in space by using an electrostatic force to adhere similar and dissimilar surfaces. A typical EA enabled device is composed of compliant space-rated materials, such as copper-clad polyimide encapsulated by polymers. Attachment is induced by strong electrostatic forces between any substrate material, such as an exterior satellite panel and a compliant EA gripper pad surface. When alternate positive and negative charges are induced in adjacent planar electrodes in an EA surface, the electric fields set up opposite charges on the substrate and cause an electrostatic adhesion between the electrodes and the induced charges on the substrate. Since the electrodes and the polymer are compliant and can conform to uneven or rough surfaces, the electrodes can remain intimately close to the entire surface, enabling high clamping pressures. Clamping pressures of more than 3 N/cm2 in shear can be achieved on a variety of substrates with ultra-low holding power consumption (measured values are less than 20 microW/Newton weight held). A single EA surface geometry can be used to clamp both dielectric and conductive substrates, with slightly different physical mechanisms. Furthermore EA clamping requires no normal force be placed on the substrate, as conventional docking requires. Internally funded research and development has demonstrated that EA can function effectively in space, even in the presence of strong ultraviolet radiation, atomic oxygen, and free electrons. We created a test setup in an existing vacuum chamber to simulate low-Earth-orbit conditions. An EA mechanism was fabricated and installed in the chamber, instrumented, operated in a vacuum, and subjected to ultraviolet photons and free electrons generated by an in-chamber multipactor electron emitter. Extensions to EA that can add value include proximity and contact sensing and transverse motion or rotation, both of which could enhance docking or assembly applications. Possible next steps include development of targeted applications for ground investigation or on-orbit subsystem performance demonstrations using low cost access to space such as CubeSats.

Bryan, Tom↗

Combining molecular beam epitaxy and low-energy electron microscopy with in situ magnetic susceptibility measurements within an integrated ultrahigh vacuum system

Quantum two-dimensional materials, including ultrathin superconducting films, are of great current research interest. These films are typically fabricated under ultra-high vacuum (UHV) conditions and are sensitive to the environment—prone to oxidation and contamination when exposed to the atmosphere. This hampers the study of their intrinsic properties by standard ex situ techniques. Here, we present a variable-temperature mutual inductance probe system integrated under UHV with molecular beam epitaxy (MBE) synthesis and low-energy electron microscopy, enabling nondestructive in situ characterization of superconducting thin films. The system employs a reflection-type configuration and reaches a low temperature (∼4 K) using a high-cooling-power, vibration-isolated cryocooler. In conclusion, we demonstrate the system performance by measuring the superconducting critical temperature in a copper-oxide thin film.

2D materials↗

EIC Hadron Beamline Vacuum Studies

Ninety percent of the EIC hadron ring vacuum chamber consists of cold-bore sections running through and interconnecting 4.55 K RHIC superconducting (SC) magnets. The EIC operating specification requires shorter bunches and 3x higher intensity beams which are not appropriate for the present RHIC stainless steel cold-bore beam tube. The intensity and emittance of the hadron beams will degrade due to interactions with residual gas or vacuum instabilities arising from the expected resistive-wall (RW) heating, electron clouds, and beam-induced desorption mechanisms. Without strategies to limit RW heating, major cryogenic system modifications are needed to prevent SC magnet quenches. The SC magnet cold-bore beam tubes will be equipped with a high RRR copper-clad stainless steel screen to significantly reduce RW heating and so the effect on the SC magnet cryogenic heat load and temperature. A thin amorphous carbon film applied to the beam-facing copper surface will suppress electron cloud formation. This paper discusses the vacuum requirements imposed by the EIC hadron beams and the plans to achieve the necessary vacuum and thermal stability that ensure acceptable beam quality and lifetime.

43 PARTICLE ACCELERATORS↗

Surface chemistry and wear behavior of single-crystal silicon carbide sliding against iron at temperatures to 1500 C in vacuum

X-ray photoelectron and Auger electron spectroscopy analyses and morphological studies of wear and metal transfer were conducted with a single-crystal silicon carbide 0001 surface in contact with iron at various temperatures to 1500 C in a vacuum of 10 to the minus 8th power pascal. The results indicate that below 800 C, carbide-carbon and silicon are primarily seen on the silicon carbide surface. Above 800 C the graphite increases rapidly with increase in temperature. The outermost surficial layer, which consists mostly of graphite and little silicon at temperatures above 1200 C is about 2 nm thick. A thicker layer, which consists of a mixture of graphite, carbide, and silicon is approximately 100 nm thick. The closer the surface sliding temperature is to 800 C, the more the metal transfer produced. Above 800 C, there was a transfer of rough, discontinuous, and thin iron debris instead of smooth, continuous and thin iron film which was observed to transfer below 800 C. Two kinds of fracture pits were observed on the silicon carbide surface: (1) a pit with a spherical asperity; and (2) multiangular shaped pits.

Miyoshi, K.↗

All-vacuum-deposited inorganic cesium lead halide perovskite light-emitting diodes

Polycrystalline CsPbBr 3 thin films are deposited by vacuum co-evaporation of cesium halide and lead halide precursors, leading to uniform pinhole-free morphology and precise control over the film thickness and precursor stoichiometry. By utilizing the organic hole and electron transport layers, all-vacuum-deposited perovskite LEDs are fabricated. The resulting devices exhibit a maximum luminance of 1800 cd/m 2 , a 531 nm emission wavelength peak with a spectral linewidth of 21 nm, and an external quantum efficiency of 1.1%.

36 MATERIALS SCIENCE↗

Spectroscopic investigation of electron-beam-induced excitation and ionization of air [Abstract]

Time-dependent visible and near-ultraviolet emission spectroscopy was used to track the presence of excited and ionized states induced as an electron beam transited a cavity filled with air at low pressures. An electron beam was produced in vacuum using a Febetron pulsed-power generator modified to produce a peak voltage of 100 kV, a peak current of 4.5 kA, and a pulse width of 100 ns. The beam electrons then passed through thin anode and pressure foils and transited a cavity filled with dry air at either 0.1 Torr or 1 Torr, exciting and ionizing the air along the way. The spectral measurements were combined with information from electrical, interferometric, and imaging diagnostics to reveal different ionization dynamics for the two cases under study.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mass Spectrometer Observing Lunar Operations (MSoLo)

Introduction: In 2019, the National Aeronautics and Space Administration (NASA) announced that it would seek to have humans return to the moon by 2024 in the hopes of establishing a more sustainable lunar presence by 2028. This goal comes with many challenges, one of upmost importance will be to utilize resources that can be found on the moon. Water, which has been identified in the lunar Polar Regions, will be a key resource for in-situ resource utilization (ISRU), as it is capable of being processed for vehicular fuel, as well as life support systems materials such as oxygen. Upcoming Commercial Lunar Payload Services (CLPS) missions will be critical for these resource assessments. Methods: A modified commercial off-the-shelf (COTS) mass spectrometer developed at Kennedy Space Center known as MSolo, consisting of a quadrupole mass filter and space rated electronics undergoes testing and modifications in order to study operational parameters to unconventional approaches needed in flight situations. In general, MSolo operates in the 0-100 m/z range with the ability to detect with a faraday cup (FC) or an electron multiplier (EM) for enhanced detection. A crossbeam (XB) ionization source is used. Preliminary Data: Prior to construction, little information was available on how the MSolo system would perform at lunar like environments, factors such as temperatures (possible fluctuations from 70 to -45 °C), vibrations from launch and their side effects, the general ability to operate while the entire system (hardware and electronic components) were in a vacuum environment, were factors that while know to flight instruments, were something new to a modified COTS system. As components start to warm up, temperature becomes a key factor (ie. heat can no longer escape the electronics as no atmosphere is present), therefore it becomes crucial to find new ways to maintain stable signals and keep the instrument tuned. Calibration itself becomes an important parameter that needs to be performed while maintaining all flight like characteristics. Even the structure itself of MSolo’s sensor needed to be changed to survive the verification parameters needed to be approved for flight. Most important, all the modifications made to the COTS system have to keep the instrument working at the same specifications of the standard commercial systems. Novel Aspect: Results gathered provide key parameters that will assist to the unconventional mass spectrometry approaches of the upcoming CLPS missions to which MSolo has been selected to.

MSolo↗

Machine Learning for Predicting Multipactor Susceptibility in Planar RF Structures

Multipactor discharge is a persistent challenge in high-power microwave (HPM) and accelerator systems, where secondary electron avalanches can cause heating, vacuum degradation, and failure. This work presents the first supervised machine learning (ML) framework for multipactor prediction, trained on high-fidelity 3D Particle-in-Cell (PIC) simulation data in planar geometries. The model maps operational, geometric, and material-dependent secondary electron yield (SEY) parameters to the time-averaged electron growth rate, enabling rapid reconstruction of susceptibility charts. Among the models evaluated, tree-based ensemble methods such as Random Forest and Extra Trees demonstrate superior generalization to unseen materials compared to neural networks such as multilayer perceptron (MLP). Performance metrics, including Intersection over Union (IoU), Structural Similarity Index Measure (SSIM), and Pearson correlation, show close agreement with simulation benchmarks. Principal Component Analysis attributes generalization limits to material feature-space disjointedness.

43 PARTICLE ACCELERATORS↗

Stability of bulk Ba2YCu3O(7-x) in a variety of environments

Small bars of ceramic Ba2YCu3O(7-x) were fabricated and subjected to environments similar to those that might be encountered during some NASA missions. These conditions include ambient conditions, high humidity, vacuum, and high fluences of electrons and protrons. The normal state resistivity or critical current density (J sub c) were monitored during these tests to assess the stability of the material. When normal state resistivity is used as a criterion, the ambient stability of these samples was relatively good, exhibiting only a 2 percent degradation over a 3 month period. The humidity stability was shown to be very poor, and to be a steep function of temperature. Samples stored at 50 C for 40 min increased in normal state resistivity by four orders of magnitude. Kinetic analysis indicates that the degradation reaction is second order with water vapor concentration. It is suspected that humidity degradation also accounts for the ambient instability. The samples were stable to vacuum over a period of at least 3 months. Degradation of J sub c in a 1 MeV electron fluence of 9.7 x 10 to the 14th e(-)/sq cm was determined to be no more than about 2 percent. Degradation of J sub c in a 8.7 x 10 to the 14th p(+)/sq cm of 42 MeV protons was found to be grain size dependent. Samples with smaller grain size and initial J sub c of about 240 A/sq cm showed no degradation. while that with larger grain size and an initial J sub c of about 30 A/sq cm degraded to 37 percent of its original value.

Gaier, James R.↗

Solar Simulation for the CREST Preflight Thermal-Vacuum Test at B-2

In June 2011, the multi-university sponsored Cosmic Ray Electron Synchrotron Telescope (CREST) has undergone thermal-vacuum qualification testing at the NASA Glenn Research Center (GRC), Plum Brook Station, Sandusky, Ohio. The testing was performed in the B-2 Space Propulsion Facility vacuum chamber. The CREST was later flown over the Antarctic region as the payload of a stratospheric balloon. Solar simulation was provided by a system of planar infrared lamp arrays specifically designed for CREST. The lamp arrays, in conjunction with a liquid-nitrogen-cooled cold wall, achieved the required thermal conditions for the qualification tests. The following slides accompanied the presentation of the report entitled Solar Simulation for the CREST Preflight Thermal-Vacuum Test at B-2, at the 27th Aerospace Testing Seminar, October 2012. The presentation described the test article, the test facility capability, the solar simulation requirements, the highlights of the engineering approach, and the results achieved. The presentation was intended to generate interest in the report and in the B-2 test facility.

Ziemke, Robert A.↗

Solar Simulation for the CREST Preflight Thermal-Vacuum Test at B-2

In June 2011, the multi-university sponsored Cosmic Ray Electron Synchrotron Telescope (CREST) has undergone thermal-vacuum qualification testing at the NASA Glenn Research Center (GRC), Plum Brook Station, Sandusky, Ohio. The testing was performed in the B- 2 Space Propulsion Facility vacuum chamber. The CREST was later flown over the Antarctic region as the payload of a stratospheric balloon. Solar simulation was provided by a system of planar infrared lamp arrays specifically designed for CREST. The lamp arrays, in conjunction with a liquid-nitrogen-cooled cryoshroud, achieved the required thermal conditions for the qualification tests. This report focuses on the design and analysis of the planar arrays based on first principles. Computational spreadsheets are included in the report.

Ziemke, Robert A.↗

Atomic binding corrections for high-energy fixed target experiments

High-energy beams incident on a fixed target may scatter against atomic electrons. To a first approximation, one can treat these electrons as free and at rest. For precision experiments, however, it is important to be able to estimate the size of, and when necessary calculate, subleading corrections. We discuss atomic binding corrections to relativistic lepton-electron scattering. We analyze hydrogen in detail, before generalizing our analysis to multi-electron atoms. Using the virial theorem, and many-body sum rules, we find that the corrections can be reduced to measured binding energies, and the expectation value of a single one-body operator. We comment on the phenomenological impact for neutrino flux normalization and an extraction of hadronic vacuum polarization from elastic muon electron scattering at MUonE.

74 ATOMIC AND MOLECULAR PHYSICS↗

Methods of fabricating vacuum housings with hermetic solder seals using capillary solder wicks

Hermetically sealed electronic devices and methods for fabricating the hermetically sealed electronic devices are provided. The devices include a solder sealed vacuum housing. The solder seal is formed using a solder wick having an external solder reservoir. When the reservoir is filled with molten solder, the solder is drawn via capillary action into a precisely defined narrow gap between two components of the housing where it forms an airtight and vacuum-tight seal.

Frisch, Henry J.↗