Thermal performance of a rhenium niobium cylindrical thermionic converter
Efficiency and steady state performance of cylindrical thermionic converter with rhenium emitter and niobium collector
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Efficiency and steady state performance of cylindrical thermionic converter with rhenium emitter and niobium collector
Thermal protection systems and components for modular nuclear vehicle
Composite multilayer insulation system of double goldized, Nylar radiation shields
Heat flux and optical property measurement for multilayer insulation
Spherically blunted 0.44-radian (25 deg) half-angle conical models coated with elastomeric ablative materials were tested in supersonic arc-heated wind tunnels to evaluate performance of the ablators over a range of conditions typical of lifting entry. Four test conditions were combinations of stagnation point-heat transfer rates of 2.3 and 4.5 MW/m2 and stagnation pressures of 20 and 2kN/m2. Afterbody values of heat transfer rate and pressure were 0.05 to 0.20 of stagnation point values. Stagnation enthalpy varied from 4.4 to 25 MJ/kg (1900 to 11000 Btu/lbm) and free-stream Mach number was in a range from 3.5 to 4. Ablative materials retained the spherical nose shape throughout tests at the lower heat transfer level, but receded, assuming a flattened nose shape, during tests at the high heat transfer level. The residue layer that formed on the conical after-body was weak, friable, and extensively cracked. The reference ablative material, which contained phenolic microspheres, generally retained the conical shape on the model afterbody. However, a modified ablator, in which phenolic microspheres were replaced with silica microspheres, deformed and separated from the undegraded material, and thereby produced a very uneven surface. Substrate temperatures and ablator recession were in good agreement with values computed by a numerical analysis.
A biothermal model with a physically-controlled subsystem and a dynamically-controlled subsystem is developed to simulate the thermoregulatory system of man under immersed conditions. The model is consistent with experimental data for seminude subjects immersed to neck in cool to temperate water and for 'wet-suited' subjects immersed to neck in cold water. Equations are derived for predicting body temperatures under various dive conditions.
A rugged modularized MLI system for a 2.23-meter-diameter (87.6-in.-diam) liquid hydrogen tank was designed, fabricated, and tested under simulated near-earth and deep-space environments. The two blankets of the system were each composed of 17 double-aluminized Mylar radiation shields separated by silk net. The unit area weight of the installed system was 1.54 kg/sqm (0.32 lb/sq ft). The overall average heat transferred into the insulated tank was 22.7 and 0.98 watts (77.4 and 3.3 Btu/hr) during simulated near-earth and deep-space testing, respectively. The near-earth result was only 2.6 times that predicted for an undisturbed insulation system (i.e., no seams or penetrations). Tests indicate that this insulation concept could be useful for a cryogenic space tug or orbit transfer vehicle application.
Explore the source record for details and available documents.
Computer program calculates loads, torques, temperature, and fatigue life of multibearing shaft system operating with either wet or dry friction. Program is also capable of predicting system reactive to termination of lubricant supply to bearings and other lubricated mechanical elements.
The test procedures used and the test results obtained from an evaluation test program conducted on a double-covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using liquid as the heat transfer medium. The absorber plate was steel with the copper tubes bonded on the upper surface. The plate was coated with black chrome with an absorptivity factor of .95 and emissivity factor of .12. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.
Test procedures used and test results obtained from an evaluation test program conducted on a single covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using water as the heat transfer medium. The absorber plate was copper with copper tubes bonded by soft solder. The plate was coated with Enthone selective black with an absorptivity factor of .87 approximately .92 and an emissivity factor of .10 approximately .20. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.
The procedures used and the results obtained during the evaluation test program on the Solaron solar air collector, model EF-212, under simulated conditions for comparison with data collected in outdoor tests on the same collector are given. The test article was a single glazed collector with a nonsensitive absorber plate, aluminum box frame, and one inch isocyanurate foam insulation.
The test procedures used and the results obtained during the evaluation test program of the Lennox/Honeywell double covered liquid solar collector. The tests were performed under simulated conditions, following long-term exposure to natural weathering conditions. The Lennox/Honeywell collector is a flat-plate solar collector. The absorber plate is steel with copper tubes bonded on the upper surface, and is coated with black chrome. Visual inspection of the collector indicated slight discoloration of the absorber plate. Results indicate that performance degradation had occurred. Absorptivity and/or transmissivity decreased as a result of the weathering.
The test procedures used and the results obtained during the evaluation test program of the Sunworks single-covered liquid solar collector are presented. The tests were performed under simulated conditions, following long-term exposure to natural weathering conditions. The sunworks collector is a flat-plate solar collector. The absorber plate is copper with copper tubes bonded by soft solder, and is coated with Enthon selective black with an absorptivity factor of .87 similar to .92 and an emissivity factor of .10 similar to .20. It has a single glass cover of 3/16 inches tempered glass and weighs about 115 pounds. The overall dimensions of the collector are 36 x 84 x 4 inches.
The test procedures used and the results obtained during the evaluation test program on the MSFC air collector with flow channel depth of 3 in., 2 in., and 1 in., under simulated conditions are presented. The MSFC hot air collector consists of a single glass cover with a nonselective coating absorber plate and uses air as the heat transfer medium. The absorber panel consists of a thin flat sheet of aluminum.
The test procedures and the results obtained during the evaluation test program on the Solaron Corporation air-type solar collector are presented. The tests were performed under simulated conditions, following long-term exposure to natural weathering conditions. The Solaron Model 2001, air-type solar collector has a gross area of 19 square feet and the weight is 160 pounds. The absorber plate is made of 24-gage steel, the coating is baked-on black paint, the cover consists of two sheets of 1/8-inch low-iron tempered glass, and the insulation is one thickness of 3 5/8-inch fiberglass batting.
The test procedures and the results obtained during the evaluation of a single-covered liquid solar collector are presented. The tests were performed under outdoor natural conditions. The collector was under stagnation conditions for a total of approximately ten months. The solar collector is a liquid, single-glazed, flat plate collector, and is about 240 inches long, and 3.8 inches in depth.
The test procedures used and the test results obtained during the performance of an evaluation test program on the Owens-Illinois Sunpak, model SEC-601, air solar collector under natural outdoor weather conditions are presented. All testing activities were performed on a single module. The test was performed and the data evaluated as applicable to outdoor testing of solar collectors.