Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A simple thermal model of the earth's surface for geologic mapping by remote sensing

Thermal inertia of the earth's surface can be used in geologic mapping as a complement to surface reflectance data as provided by Landsat. Thermal inertia cannot be determined directly but must be inferred from radiation temperature measurements (by thermal IR sensors) made at various times in the diurnal cycle, combined with a model of the surface heating processes. A model is developed which differs from those created previously for this purpose, because it includes sensible and latent heating. Tests of this model using field data indicate that it accurately determines the surface heating. When the model is used with field measurements of meteorological variables and is combined with remotely sensed temperature data, a thermal inertia image can be produced.

Kahle, A. B.↗

THERMAL MODELING OF ION EXCHANGE COLUMNS WITH SPHERICAL RF RESIN

Models have been developed to simulate the thermal performance of RF columns fully loaded with radioactive cesium. Temperature distributions and maximum temperatures across the column were calculated during Small Column Ion Exchange (SCIX) process upset conditions with a focus on implementation at Hanford. A two-dimensional computational modeling approach was taken to include conservative, bounding estimates for key parameters such that the results will provide the maximum centerline temperatures achievable under the design configurations using a feed composition known to promote high cesium loading on RF. The current full-scale design for the SCIX system includes a central cooling tube, and one objective of these calculations was to examine its elimination to simplify the design. Results confirmed that a column design without a central cooling tube is feasible for RF, allowing for the possibility of significant design simplifications if it can be assumed that the columns are always filled with liquid. With active cooling through the four outer tubes, the maximum column diameter expected to maintain the temperature below the assumed media and safety limits is 26 inches, which is comparable to the current design diameter. Additional analysis was conducted to predict the maximum column temperatures for the previously unevaluated accident scenario involving inadvertent drainage of liquid from a cesium-saturated column, with retention of the ion exchange media and cesium in the column. As expected, much higher maximum temperatures are observed in this case due to the poor heat transfer properties of air versus liquid. For this hypothetical accident scenario involving inadvertent and complete drainage of liquid from a cesium-saturated column, the modeling results indicate that the maximum temperature within a 28 inch diameter RF column with external cooling is expected to exceed 250 C within 2 days, while the maximum temperature of a 12 inch column is maintained below 100 C. In addition, the calculation results demonstrate that the cooling tube system external to an air-filled column is not highly effective at reducing the maximum temperature, but the baseline design using a central cooling tube inside the column provides sufficient cooling to maintain the maximum temperature near the assumed safety limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coupling of Mechanical Behavior of Lithium Ion Cells to Electrochemical-Thermal Models for Battery Crush; NREL (National Renewable Energy Laboratory)

Propagation of failure in lithium-ion batteries during field events or under abuse is a strong function of the mechanical response of the different components in the battery. Whereas thermal and electrochemical models that capture the abuse response of batteries have been developed and matured over the years, the interaction between the mechanical behavior and the thermal response of these batteries is not very well understood. With support from the Department of Energy, NREL has made progress in coupling mechanical, thermal, and electrochemical lithium-ion models to predict the initiation and propagation of short circuits under external crush in a cell. The challenge with a cell crush simulation is to estimate the magnitude and location of the short. To address this, the model includes an explicit representation of each individual component such as the active material, current collector, separator, etc., and predicts their mechanical deformation under different crush scenarios. Initial results show reasonable agreement with experiments. In this presentation, the versatility of the approach for use with different design factors, cell formats and chemistries is explored using examples.

25 ENERGY STORAGE↗

Thermal modeling and efficiency of a dual-stage sodium heat engine

In this paper, a thermal design of an axisymmetric dual-stage sodium thermal electrochemical converter (Na-TEC) is presented, where a reduced-order finite-element model is used in conjunction with a Na-TEC thermodynamic model to determine the total parasitic heat loss of this dual-stage design. A number of simplifications are applied in the reduced-order model to decrease the computational time while maintaining acceptable accuracy. These include the use of effective thermal conductivities to account for complex corrugated geometries and apparent surface emissivities to accommodate the effect of radiation shields. Furthermore, a simplified analytical model is developed to account for conduction bypass through the Na-TEC liquid-return path. An iterative procedure between the finite-element and thermodynamic models is described in detail, and the thermal performance of the design proposed herein is analyzed. According to this analysis, a maximum efficiency of 29% and a maximum power output of 125 W can be achieved.

14 SOLAR ENERGY↗

Thermal models for icy satellites

The solid state greenhouse models were constrained for water ice surfaces using thermal eclipse data. As a result, it was determined that at depths of 3 cm or more Europa can have about a 30 K temperature enhancement over the diurnal mean surface temperature of about 97 K at the equator. It was also determined that the unusual shape of Europa's thermal flux curves during eclipses can be explained by the solid state greenhouse effect. The solid state greenhouse models were applied to the problem of the origin and energy sources of Triton's geyser-like plumes. Two classes of models are examined which may explain the driving energy for Triton's plumes. Triton's internal heatflow is recognized as a major contributor to its global energy balance. Internal heat flow from radioactive decay in Triton's interior along with absorbed thermal energy from Neptune total 5 to 20 pct. of the insolation absorbed by Triton, thus comprising a significant fraction of Triton's surface energy balance.

Brown, Robert H.↗

Fuel Heating System Design and Thermal Modeling for Aviation Combustion Research

Aviation fuels offer substantial heat-sink capability that can be applied to aircraft thermal-management strategies and advanced propulsion-system concepts. Accurate control of fuel temperature is critical for understanding combustion behavior and supporting high temperature fuel experimental studies. This work describes the modeling and experimental validation of a portable, high temperature fuel-conditioning system designed for multiple NASA Glenn Research Center’s combustion facilities. The system utilizes a circulating-oil heating unit and modular tube-in-tube heat exchangers capable of conditioning Jet-A to temperatures approaching 600 K. A Thermal Desktop model was created to analyze heat exchanger configurations and predict performance across a range of operating conditions. Model predictions were compared with measurements collected in the CE-13C test facility, showing good agreement across the tested flow range except at low fuel flow rate around 2 kg/hr. Results provide guidance for sizing future fuel heating system for combustion research applications.

Jet fuel heating system↗

Hall Thruster Thermal Modeling and Test Data Correlation

HERMeS - Hall Effect Rocket with Magnetic Shielding. Developed through a joint effort by NASA/GRC and the Jet Propulsion Laboratory (JPL). Design goals: High power (12.5 kW) high Isp (3000 sec), high efficiency (> 60%), high throughput (10,000 kg), reduced plasma erosion and increased life (5 yrs) to support Asteroid Redirect Robotic Mission (ARRM). Further details see "Performance, Facility Pressure Effects and Stability Characterization Tests of NASAs HERMeS Thruster" by H. Kamhawi and team. Hall Thrusters (HT) inherently operate at elevated temperatures approx. 600 C (or more). Due to electric magnetic (E x B) fields used to ionize and accelerate propellant gas particles (i.e., plasma). Cooling is largely limited to radiation in vacuum environment.Thus the hardware components must withstand large start-up delta-T's. HT's are constructed of multiple materials; assorted metals, non-metals and ceramics for their required electrical and magnetic properties. To mitigate thermal stresses HT design must accommodate the differential thermal growth from a wide range of material Coef. of Thermal Expansion (CTEs). Prohibiting the use of some bolted/torqued interfaces.Commonly use spring loaded interfaces, particularly at the metal-to-ceramic interfaces to allow for slippage.However most component interfaces must also effectively conduct heat to the external surfaces for dissipation by radiation.Thus contact pressure and area are important.

Model↗

Saturn's icy satellites - Thermal and structural models

Thermal history models which assume formation as homogeneous ice-silicate mixtures are constructed for the small, icy Saturnian satellites Mimas, Tethys, Dione, Rhea, and Iapetus, including the effects of radiogenic and accretional heating, conductive and subsolidus convective heat transfer, and lithosphgeric growth. Accretional heating is not likely to have melted the water ice in the interiors of these bodies, and solid state creep of the ice-dominated material precludes melting by radiogenic heating. The four largest satellites are sufficiently large and rich in heat-producing silicates to possess a solid state convection system beneath a rigid lithosphere, irrespective of initial conditions. The model thermal histories are qualitatively consistent with the present appearances of these satellites.

Ellsworth, K.↗

Flow and thermal modelling of the argon volume in the DarkSide-20k TPC

The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ∼ 50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (∼ 40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of 83m Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.

47 OTHER INSTRUMENTATION↗

Discrete Green’s functions and spectral graph theory for computationally efficient thermal modeling

Here, this work concerns solutions of the heat equation with the spectral graph method, for which the temperature is defined at discrete points in the domain and the spatial relationship among the points is described by a graph. The heat equation on the graph is solved using matrix techniques involving the eigenvectors and eigenvalues of the Laplacian matrix. The spectral graph approach precludes the computationally intensive meshing and numerous time-integration steps of the finite element method. In the present work, the spectral graph method is extended to include heat loss at the boundaries with a generalized boundary condition, and physics-based edge weights are introduced which simplify the calibration process. From this approach a discrete Green’s function is defined which allows for solutions under a variety of heating conditions including: space-varying initial conditions; time-and-space varying internal heating; and, time-and-space-varying heating at boundaries of type 1 (Dirichlet), type 2 (Neumann) and type 3 (Robin). Results are provided for benchmark heat transfer problems in one spatial dimension and in three spatial dimensions, and verification is provided by comparison with exact analytical solutions and finite difference solutions. The spectral graph method converges within 0.4% error of the analytical solution. The practical utility of the approach is demonstrated by thermal simulation of a multilayer additive manufacturing process. The spectral graph results are compared to experimentally-obtained temperature data for two metal parts, with error less than 5% of the experimental measurements, with computation time less than one minute on a desktop computer.

36 MATERIALS SCIENCE↗

Safe Affordable Fission Engine (SAFE 30) Module Conductivity Test Thermal Model Correlation

Two SAFE 30 modules were tested to determinate the thermal conductivity efficiency of the tri-cusps filled between the heat pipe and the heater cores. The modules consisted of four one-inch diameter tubes with heaters joined to an empty 1 inch diam. tube. The test was conducted on a vacuum chamber with 4 configurations: tri-cusps filled with and without radiation shielding and non-filled tri-cusps with and without radiation shielding. The tri-cusps material helps the bonding of the heat pipe to the four electric heater cores, filling the gap between the pipes. The baseline configuration is a brazed joint between the pipe. The test consisted of controlling the power applied to the heaters until a set surface temperature is reach. The temperatures varied between a max. of 800 C to 500 C. Test data, input energy and chamber surface temperature from each individual test, was used as boundary conditions for the model. Nodes located on the same location as the test thermocouples were plotted again test data to determinate the accuracy of the analysis. The unknown n variables on the analysis are the radiation emissivity of the pipe and chamber and the radiation view factor between the module and the chamber. A correlation was determined using a parametric analysis varying the surface emissivity and view factor until a good match was reach.

Roman, Jose↗

Thermal Modeling of an Advanced Geared Turbofan for Distributed Engine Control Application

Reliability and life-expectancy of gas turbine engine components is very much correlated to the temperature environment in which they operate. This is no different for control system components, especially those with electronic parts. In recent years, the concept of Distributed Engine Control (DEC) has emerged to address the limitations of the current centralized control implementation. This new approach involves relocating control system components from a relatively benign environment to the harsher thermal environment of the engine casing and its surrounding structures and cavities. In this paper, an approach to modeling the gas turbine thermal environment is described. The modeling approach is applied to a 3rd generation geared turbofan design with a focus on the engine locations where control instrumentation and actuation could be installed. The analysis was conducted with an eye toward component reliability and service life as it relates to the thermal environment. The results were found to be reasonable. Furthermore, the model is shown to execute in real-time within a multi-model simulation environment that demonstrates the capability to interact with hardware to drive test equipment.

Kratz, Jonathan↗

Nondimensional convection numbers modeling thermally stratified storage tanks: Richardson's number and hot-water tanks

Thermally stratified storage tank studies have spanned over 50 years to increase the thermal storage efficiency and accurate prediction of the outlet temperature particularly for solar applications. The studies have reviewed and modeled the jet and plume flow phenomena inside the tank due to the inlet mixing and stratification level. Kelvin–Helmholtz and Rayleigh–Taylor instabilities are the major drivers of the mixing in these tanks. Momentum jets deflecting off walls at the bottom of the tank also create significant mixing. Reviewing Richardson models shows that the categorization was based on the range of Reynolds numbers at the inlet. Unfortunately, the use of superficial velocity in calculating the Richardson number results in critical values in the literature ranging from below 0.25 to 100. The most used length scale associated with these flows is an inertial scale based on the tank height or diameter although the mixing can occur at a relatively smaller scale. The various inlet devices and a large span of flow rates experienced in thermally stratified storage tanks requisite the use of the Reynolds number in combination with a convection number for accurate one dimensional models that predict performance over the long-term. The evaluation of peak shifting of electric loads leveraging renewable sources for applications, including residential hot-water tanks, commercial water tanks, and large-scale chilled water storage tanks, require these models. Finally, this paper is focused on establishing the significance of the convection numbers in conjunction with the Reynolds number for modeling the thermal stratification in storage tanks.

14 SOLAR ENERGY↗

Adiabatic and nonadiabatic processes in thermal models of solar hard X-ray bursts

The temporal evolution of thermal-bremsstrahlung-emitting material at the top of a solar coronal loop under various processes is examined as a model of solar hard X-ray bursts. The behavior of emission measure and temperature with time is analyzed for the hot plasma confined in a segment at the top of a loop, taking into account the effects or the time variation of the confining toroidal magnetic field, the longitudinal expansion of the source through the motion of a pair of collisionless conduction fronts and unspecified heating or cooling processes. Analytic expressions for the behavior of the toroidal magnetic field and the heating rate necessary to reproduce a given behavior of emission measure and temperature with time are obtained in terms of the initial magnetic field strength and density of the heated region and a characteristic longitudinal expansion time. Results are applied to observations of two impulsive solar hard X-ray bursts, and it is shown that the contribution of heating is negligible after the first few seconds of the events, although significant nonadiabatic heating occurs early in the events.

Emslie, A. G.↗

A thermal model for analysis of infrared images

A mathematical model derived from the equation of heat conduction was developed to assist in interpreting thermal infrared images acquired from aircraft and spacecraft. The model assumes steady state boundary conditions. It contains parameters of rock and soil properties, atmospheric effects, site location, and season. The results predicted provide an explanation for the thermal differences among granite, limestone, and dolomite recorded in the December 1968 daytime and predawn flights over the Mill Creek, Oklahoma test site, during which representative thermal inertia and albedo values were used. A second test of the model made use of data acquired during the June 1970 predawn overflight of Mill Creek. A simple model of transient heating of the ground was constructed as an extension of the overall model, in order to examine the effects of atmospheric perturbations. The results obtained are consistent with those of ground observations made at the time of the overflight.

Watson, K.↗

One-dimensional thermal modeling of vertical Bridgman-type crystal growth

Articles by Naumann (1982) and Jasinski et al. (1983) examined the axial temperature distribution of the charge during vertical Bridgman-type crystal growth. A comparison of their results demonstrates that Naumann's model is applicable for K (ratio of crucible to charge thermal conductivity) equal to or greater than 1 or for small Biot numbers. The Jasinski model provides a correction for larger Biot numbers and is also applicable for small values of K.

Jasinski, T.↗

Preliminary Thermal Modeling of HI-STORM 100 Storage Modules at Diablo Canyon Power Plant ISFSI

Thermal analysis is being undertaken at Pacific Northwest National Laboratory (PNNL) in support of inspections of selected storage modules at various locations around the United States, as part of the Used Fuel Disposition Campaign of the U.S. Department of Energy, Office of Nuclear Energy (DOE-NE) Fuel Cycle Research and Development. This report documents pre-inspection predictions of temperatures for two modules at the Diablo Canyon Power Plant ISFSI identified as candidates for inspection. These are HI-STORM 100 modules of a site-specific design for storing PWR 17x17 fuel in MPC-32 canisters. The temperature predictions reported in this document were obtained with detailed COBRA-SFS models of these storage systems, with the following boundary conditions and assumptions. • storage module overpack configuration based on FSAR documentation of HI-STORM100S-218, Version B; due to unavailability of site-specific design data for Diablo Canyon ISFSI modules • Individual assembly and total decay heat loadings for each canister, based on at-loading values provided by PG&E, “aged” to time of inspection using ORIGEN modeling - Special Note: there is an inherent conservatism of unquantified magnitude – informally estimated as up to approximately 20% -- in the utility-supplied values for at-loading assembly decay heat values • Axial decay heat distributions based on a bounding generic profile for PWR fuel. • Axial location of beginning of fuel assumed same as WE 17x17 OFA fuel, due to unavailability of specific data for WE17x17 STD and WE 17x17 Vantage 5 fuel designs • Ambient conditions of still air at 50°F (10°C) assumed for base-case evaluations - Wind conditions at the Diablo Canyon site are unquantified, due to unavailability of site meteorological data - additional still-air evaluations performed at 70°F (21°C), 60°F (16°C), and 40°F (4°C), to cover a range of possible conditions at the time of the inspection. (Calculations were also performed at 80°F (27°C), for comparison with design basis assumptions.) All calculations are for steady-state conditions, on the assumption that the surfaces of the module that are accessible for temperature measurements during the inspection will tend to follow ambient temperature changes relatively closely. Comparisons to the results of the inspections, and post-inspection evaluations of temperature measurements obtained in the specific modules, will be documented in a separate follow-on report, to be issued in a timely manner after the inspection has been performed.

Site Inspection↗