A fast and nonintrusive velocity and temperature diagnostic based on oxygen absorption is presented. The system uses a GaAlAs tunable diode laser, ramped and modulated in wavelength at high frequency. Detection is performed at twice the modulating frequency, leading to second harmonic absorption lineshapes. Velocity is inferred from the wavelength shift of the absorption line center due to the Doppler effect. Temperature is determined by comparing experimental and calculated lineshapes. Capabilities of the technique for studies of transient high-speed flows are demonstrated in shock tube experiments. Good agreement is obtained with predicted temperatures and velocities when pressure-induced shifts are accounted for.

Philippe, L. C.↗

Fiber optic and laser sensors X; Proceedings of the Meeting, Boston, MA, Sept. 8-11, 1992

Topics addressed include acoustic and pressure sensors; fiber optic gyros; electric and magnetic field sensors; bend, strain, and temperature sensors; industrial applications of sensors; and processing techniques. Particular attention is given to fiber optic interferometric acoustic sensors for wind tunnel applications, polished coupler and resonator fabrication, second-harmonic detection for rotation sensing in fiber optic gyros, simplified control theory in closed-loop fiber optic gyroscopes, and a Fabry-Perot sensor with digital signal processing for the measurement of magnetostriction. Also discussed are a Bragg fiber laser sensor, commercialization of fiber optic strain gauge systems, thermal ignition in hazardous environments due to stray light from optical fibers, a system for absolute measurements by interferometric sensors, and high-performance interferometric demodulation techniques.

Udd, Eric↗

High- and Mid-temperature Superconducting Sensors for Far IR/Sub-mm Applications in Space

In this review paper an overview of the potential applications of high Tc (approx. 90 K) superconductors (HTS) and mid-Tc (approx. 39 K) superconductors (MTS) thin films in far IR/Sub-mm thermal detectors is presented. HTSs (YBCO, GdBCO etc.) were discovered in the late 80s while superconductivity in MgB2, an MTS, was discovered in 2001. The sharp transition in transport properties of HTS has allowed the fabrication of composite infrared thermal detectors (bolometers) with better figures of merit than thermopile detectors - thermopiles are currently on board the CIRS instrument on the Cassini mission to Saturn. The potential for developing even more sensitive sensors for IR/Sub-mm applications using MgB2 thin films is assessed. Current MgB2 thin film deposition techniques and film quality are reviewed.

Lakew, Brook↗

Machine vision guided sensor positioning system for leaf temperature assessment

A sensor positioning system was developed for monitoring plants' well-being using a non-contact sensor. Image processing algorithms were developed to identify a target region on a plant leaf. A novel algorithm to recover view depth was developed by using a camera equipped with a computer-controlled zoom lens. The methodology has improved depth recovery resolution over a conventional monocular imaging technique. An algorithm was also developed to find a maximum enclosed circle on a leaf surface so the conical field-of-view of an infrared temperature sensor could be filled by the target without peripheral noise. The center of the enclosed circle and the estimated depth were used to define the sensor 3-D location for accurate plant temperature measurement.

NASA Discipline Life Support Systems↗

Comparison of fiber-optic distributed temperature sensing and high-sensitivity sensor spatial surveying of stream temperature

Measuring surface water temperature spatial variability is needed to estimate the interaction between surface water and groundwater, evaluate fish habitat and thermal inertia, and to estimate streamflow frequency and duration. Fiber optic distributed temperature sensing (FO-DTS) has been used in rivers and lakes, providing high-resolution and sensitive temperature monitoring over large temporal and spatial scales. However, in streams with cobbly or bedrock-lined streambeds and variable bathymetry, use of FO-DTS to measure temperature close to the surface water and groundwater interface can be challenging if even feasible. FO-DTS can also be costly, involve difficult installations, and require an advanced understanding of the technology, calibration, and data processing. In this study, we compared FO-DTS stream temperature survey results to an alternative temperature survey method employing a towed transect of high-resolution temperature loggers spaced at 1-m and transported in the stream along the study reach, to measure the spatial distribution of stream-water temperature in East Fork Poplar Creek near Oak Ridge, Tennessee, USA. We assessed the applicability and limitations of the two methods, and quantitatively compared in-situ temperature survey results measured simultaneously with each method. Regression results showed strong temporal and spatial correlation between the two methods. Differences were only elevated near the stream banks in areas that were coincident with correlation slope deviations from unity, which was attributed to shallower water and lower data density. Kriging standard errors were also low at channel center with minor increases near the stream banks. Furthermore, the results suggested that the array of the individual temperature sensors can provide a practical alternative to FO-DTS for thermal characterization of surface water, providing slightly lower spatial and temporal resolution, but with higher accuracy of temperature measurement, with greater simplicity, and with a broader range of conditions where it may be applied.

54 ENVIRONMENTAL SCIENCES↗

Ground surface temperature derived Snow Cover Properties, Seward Peninsula, Alaska, 2019-2023

Snow-ground interface temperatures have been collected at the Teller mile marker 27 and Kougarok mile marker 64 field sites on the Seward Peninsula, Alaska from 2019 through 2023 (with data missing from Fall 2020 through Summer 2021 due to COVID). Temperatures were measured using iButton Link DS1921G-F5# Thermochron miniature temperature sensors and Tinytag TGP-4017 internal sensors deployed across the Kougarok 64 and Teller 27 field sites. These sensors are a cost-efficient way to collect snow-ground interface temperatures at a high spatial resolution, and when paired with air temperature data these measurements can provide insight into fine-scale variability in snowpack characteristics across the study sites. From this data, snow process metrics were calculated at each sensor location based on the methods outlined in Staub and Delaloye, 2017. Metrics are calculated daily for each sensor as well as over the entire season. These metrics include ground surface temperature (°C), the number of days under snow cover (number of days), the insulation effect of snow (unitless), the length of the transitional snow periods (number of days), as well as intermediaries such as temperature variability. Calculating these snow processes relies on the assumption that when snow covers a temperature sensor, it is buffered from diurnal fluctuations in air temperature by the insulating snow layer. More information on the calculated metrics can be found in the User Guide of this dataset, as well as in Staub and Delaloye’s 2017 publication Using Near-Surface Ground Temperature Data to Derive Snow Insulation and Melt Indices for Mountain Permafrost Applications. This dataset includes one daily and one seasonal *.csv file of metrics for every year of data, a daily and a seasonal *.csv data dictionary, and one User Guide document (*.pdf) describing data collection and processing.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Study of payload sensor contamination

Epoxy/glass test specimens representing Scout fourth and fifth stage motor casings were prepared and studied in a test program designed to determine the relative contamination contributed to payload sensors located near the motor casings. The relative contamination detected in the test program was dependent on several factors, including: (1) distance of test specimen to sensor, (2) sensor temperature, (3) geometric position of the sensor (relative to test specimen), (4)test specimen temperature, (5) chemical composition of the test specimen, (6) sensor function, and (7) additional materials (such as adhesive-backed aluminum tape) added to the test specimens. The thermal characteristics and the decomposition and outgassing products were determined. These data were used to better understand the relative contamination data from the remote sensor testing.

Smith, F. J.↗

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗

Distributed Coaxial Cable Sensors for In-Situ Condition Based Monitoring of Coal-Fired Boiler Tubes

The increasing contributions of renewable energy sources present new challenges to the operation and maintenance of the existing coal-fired power plants. One of the major operational risks is the unexpected failure of superheater boiler tubes, leading to the most unplanned power plant outrages. The boiler tube failure is difficult to predict due to the harsh operating environments. Therefore, condition-based monitoring (CBM) with a reliable high temperature sensor becomes necessary to produce a meaningful assessment of the health condition of boiler tubes and their remaining lifetime. In this work, the stainless-steel and quartz coaxial cable sensor (SSQ-CCS) is proposed for in-situ distributed monitoring of the boiler tube temperatures in existing coal-fired power plants. Comprehensive tests have been conducted with an in-house testing facility at Clemson University to study and evaluate the sensors’ performance in the temperature range of 100℃ to 600℃. The results indicated that the measurement resolution of the SSQ-CCS sensor is better than 1℃, and the drift is less than 2% over long-period testing. Meanwhile, multi-physics finite element analysis has been conducted to optimize the design and evaluate the safety of the SSQ-CCS temperature sensor under various operational conditions. Based on the performance obtained in the laboratory-scale testing, a field test has been implemented at a power plant. Four SSQ-CCS temperature sensors were installed for in-situ monitoring of the temperatures of a power plant’s superheat tube assembles. The data acquisition system has been successfully set up and collected sensing signals for more than three months. The sensing signals have been post-processed, and the monitored temperature history through the SSQ-CCS temperature sensor has been validated and compared with the conventional high temperature thermal couple data.

Jiao, Xinyu↗

Temperature-Sensitive Coating Sensor Based on Hematite

A temperature-sensitive coating, based on hematite (iron III oxide), has been developed to measure surface temperature using spectral techniques. The hematite powder is added to a binder that allows the mixture to be painted on the surface of a test specimen. The coating dynamically changes its relative spectral makeup or color with changes in temperature. The color changes from a reddish-brown appearance at room temperature (25 C) to a black-gray appearance at temperatures around 600 C. The color change is reversible and repeatable with temperature cycling from low to high and back to low temperatures. Detection of the spectral changes can be recorded by different sensors, including spectrometers, photodiodes, and cameras. Using a-priori information obtained through calibration experiments in known thermal environments, the color change can then be calibrated to yield accurate quantitative temperature information. Temperature information can be obtained at a point, or over an entire surface, depending on the type of equipment used for data acquisition. Because this innovation uses spectrophotometry principles of operation, rather than the current methods, which use photoluminescence principles, white light can be used for illumination rather than high-intensity short wavelength excitation. The generation of high-intensity white (or potentially filtered long wavelength light) is much easier, and is used more prevalently for photography and video technologies. In outdoor tests, the Sun can be used for short durations as an illumination source as long as the amplitude remains relatively constant. The reflected light is also much higher in intensity than the emitted light from the inefficient current methods. Having a much brighter surface allows a wider array of detection schemes and devices. Because color change is the principle of operation, the development of high-quality, lower-cost digital cameras can be used for detection, as opposed to the high-cost imagers needed for intensity measurements with the current methods. Alternative methods of detection are possible to increase the measurement sensitivity. For example, a monochrome camera can be used with an appropriate filter and a radiometric measurement of normalized intensity change that is proportional to the change coating temperature. Using different spectral regions yields different sensitivities and calibration curves for converting intensity change to temperature units. Alternatively, using a color camera, a ratio of the standard red, green, and blue outputs can be used as a self-referenced change. The blue region (less than 500 nm) does not change nearly as much as the red region (greater than 575 nm), so a ratio of color intensities will yield a calibrated temperature image. The new temperature sensor coating is easy to apply, is inexpensive, can contour complex shape surfaces, and can be a global surface measurement system based on spectrophotometry. The color change, or relative intensity change, at different colors makes the optical detection under white light illumination, and associated interpretation, much easier to measure and interpret than in the detection systems of the current methods.

Bencic, Timothy J.↗

Development of advanced high-temperature heat flux sensors

Various configurations of high temperature, heat flux sensors were studied to determine their suitability for use in experimental combustor liners of advanced aircraft gas turbine engines. It was determined that embedded thermocouple sensors, laminated sensors, and Gardon gauge sensors, were the most viable candidates. Sensors of all three types were fabricated, calibrated, and endurance tested. All three types of sensors met the fabricability survivability, and accuracy requirements established for their application.

Atkinson, W. H.↗

Fiber Optic Thermal Health Monitoring of Composites

A recently developed technique is presented for thermographic detection of flaws in composite materials by performing temperature measurements with fiber optic Bragg gratings. Individual optical fibers with multiple Bragg gratings employed as surface temperature sensors were bonded to the surfaces of composites with subsurface defects. The investigated structures included a 10-ply composite specimen with subsurface delaminations of various sizes and depths. Both during and following the application of a thermal heat flux to the surface, the individual Bragg grating sensors measured the temporal and spatial temperature variations. The data obtained from grating sensors were analyzed with thermal modeling techniques of conventional thermography to reveal particular characteristics of the interested areas. Results were compared with the calculations using numerical simulation techniques. Methods and limitations for performing in-situ structural health monitoring are discussed.

Wu, Meng-Chou↗

Fiber Optic Thermal Detection of Composite Delaminations

A recently developed technique is presented for thermographic detection of delaminations in composites by performing temperature measurements with fiber optic Bragg gratings. A single optical fiber with multiple Bragg gratings employed as surface temperature sensors was bonded to the surface of a composite with subsurface defects. The investigated structure was a 10-ply composite specimen with prefabricated delaminations of various sizes and depths. Both during and following the application of a thermal heat flux to the surface, the individual Bragg grating sensors measured the temporal and spatial temperature variations. The data obtained from grating sensors were analyzed with thermal modeling techniques of conventional thermography to reveal particular characteristics of the interested areas. Results were compared and found to be consistent with the calculations using numerical simulation techniques. Also discussed are methods including various heating sources and patterns, and their limitations for performing in-situ structural health monitoring.

Wu, Meng-Chou↗

Aerosol‐Jet‐Printable Covalent Organic Framework Colloidal Inks and Temperature‐Sensitive Nanocomposite Films

Abstract With molecularly well‐defined and tailorable 2D structures, covalent organic frameworks (COFs) have emerged as leading material candidates for chemical sensing, storage, separation, and catalysis. In these contexts, the ability to directly and deterministically print COFs into arbitrary geometries will enable rapid optimization and deployment. However, previous attempts to print COFs have been restricted by low spatial resolution and/or post‐deposition polymerization that limits the range of compatible COFs. Here, these limitations are overcome with a pre‐synthesized, solution‐processable colloidal ink that enables aerosol jet printing of COFs with micron‐scale resolution. The ink formulation utilizes the low‐volatility solvent benzonitrile, which is critical to obtaining homogeneous printed COF film morphologies. This ink formulation is also compatible with other colloidal nanomaterials, thus facilitating the integration of COFs into printable nanocomposite films. As a proof‐of‐concept, boronate‐ester COFs are integrated with carbon nanotubes (CNTs) to form printable COF‐CNT nanocomposite films, in which the CNTs enhance charge transport and temperature sensing performance, ultimately resulting in high‐sensitivity temperature sensors that show electrical conductivity variation by 4 orders of magnitude between room temperature and 300 °C. Overall, this work establishes a flexible platform for COF additive manufacturing that will accelerate the incorporation of COFs into technologically significant applications.

2D materials↗

Heat flow experiment

The heat flow experiment installed on the lunar surface during the Apollo 15 flight is described. Subjects discussed are: (1) the experiment concept and design, (2) the operations of the experiment, (3) the employment of the experiment on the lunar surface at Hadley Rille site, (4) subsurface lunar temperatures, and (5) extrapolation of sensor temperatures to equilibrium values. Graphs of the data obtained from the experiment are provided.

Langseth, M. G., Jr.↗

Structural analysis of stratocumulus convection

The 1 and 20 Hz data are examined from the Electra flights made on July 5, 1987. The flight legs consisted of seven horizontal turbulent legs at the inversion, midcloud, and below clouds, plus 4 soundings made within the same period. The Rosemont temperature sensor and the top and bottom dewpoint sensors were used to measure temperature and humidity at 1 Hz. Inversion structure and entrainment; local dynamics and large scale forcing; convective elements; and decoupling of cloud and subcloud are discussed in relationship to the results of the Electra flight.

Siems, S. T.↗

Pressure transducer and system for cryogenic environments

A silicon pressure die is bonded to a borosilicate substrate above the pneumatic port. A Wheatstone bridge circuit is formed on the silicon pressure die and has bridge elements of silicon doped with boron to a deposit density level of approximately 1 x 10(exp 19)-10(exp 21) boron/cc. A current source is provided to excite the Wheatstone bridge circuit. In addition, a temperature sensor is provided to provide temperature readings. An array may be formed of the resulting pressure transducers. This unique solution of materials permits operation of a pressure transducer in cryogenic environments.

Chapman, John J.↗