Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Evaluation of Low Dose Silicon Carbide Temperature Monitors

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at materials and test reactors. Melt wires or paint spots are often included in such tests as an independent technique of detecting peak temperatures incurred during irradiation. In addition, less expensive static capsule tests, which have no leads attached for real-time data transmission, often rely on melt wires and paint spots as a post-irradiation technique for peak temperature indication. Unfortunately, these techniques are limited in that they can only detect whether a single temperature is or is not exceeded. Silicon carbide (SiC) monitors are advantageous because a single monitor can be used to determine the peak temperature reached within a relatively broad range (200 – 800°C). Although the use of SiC monitors was proposed more than five decades ago, the ultimate performance limits of this technique are not fully understood. The Nuclear Science User Facilities (NSUF) is the United States Department of Energy Office of Nuclear Energy's only designated nuclear energy user facility. Its mission is to provide nuclear energy researchers access to world-class capabilities and to facilitate the advancement of nuclear science and technology. This mission is supported by providing access to state-of-the-art experimental irradiation testing, post irradiation examination facilities, and high performance computing capabilities as well as technical and scientific assistance for the design and execution of projects. As part of an NSUF project, low dose silicon carbide monitors were irradiated in the Belgian Reactor 2 and were then evaluated both at the SCK•CEN and at Idaho National Laboratory's High Temperature Test Laboratory to determine their peak temperature achieved during irradiation. The technical significance of this work was that the monitors were irradiated to a dose that was significantly less than recommended in published literature. This paper will discuss the evaluation process, the irradiation test, and the performance of the low dose silicon carbide temperature monitors.

36 MATERIALS SCIENCE↗

Thermomechanical Degradation of Sintered Copper Under High-Temperature Thermal Shock

The need for reliable bonded interface materials is critical to realize the performance benefits of wide-bandgap devices in power electronics modules, especially in operating temperatures greater than 150 degrees C. In this paper, we investigate the thermomechanical performance of sintered copper (Cu) as a large-area attachment, bonded between Cu baseplates and active-metal-bonded substrates, under accelerated thermal shock (-40 degrees C to 200 degrees C) conditions. In the fabrication phase of the samples, we used different stencil patterns and found that the grid and stripe patterns resulted in a better outgassing of the residual organics during the sintering process, thereby ensuring a substantially improved bond quality compared to a full-area print. The paste consisted of Cu microflakes, and we performed sintering using a Budatec SP300 sintering press at 275 degrees C with 15 MPa of bonding pressure for 5 minutes in a nitrogen atmosphere. Under accelerated experiments, we monitored the degradation of the sintered Cu bond in the samples through C-mode scanning acoustic microscope (C-SAM) images. To quantify the defect percentage in C-SAM images, we investigated image denoising techniques to exclude the pattern prints. Finally, we cross-sectioned a sample and obtained scanning electron microscope images, which revealed adhesive fracture as the dominant failure mechanism.

ADVANCED PROPULSION SYSTEMS,INORGANIC, ORGANIC, PH↗

Construction of a New MgB 2 Coating System for 1.3-GHz Superconducting RF Cavities at LANL

After many years of evaluating MgB 2 films prepared with various techniques for the application to superconducting radio-frequency (SRF) cavities, we have decided to build a system to coat full-size 1.3-GHz elliptical cavities. This paper describes the design and construction of the system. Additionally, we briefly describe experimental results with a small system and first tests with the new large system. In conclusion, we were able to obtain superconducting samples with a T c of up to 38 K with the small system, but we have not been able to get any superconducting samples with the new system yet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Report on ISR-1 High-Altitude Balloon Flight

To test small technologies at lower cost for space science applications, LANL has developed a small high altitude balloon payload that could, in the future, be regularly and inexpensively launched from LANL. A neutron detector, NEMO, was integrated to evaluate its performance in a space-like mixed-radiation environment and collect neutron data in the atmosphere. In collaboration with EES-14, a high-altitude balloon payload was launched from LANL Technical Area 51 on February 27, 2023 and April 17, 2023. For real-time geolocation, a SAM-M8Q M8 GNSS module was used to get position and time, and an Iridium RockBLOCK 9603 was used to communicate with the ground using the Iridium satellite fleet. These modules were all controlled using an Iteaduino Mega microcontroller board. Finally, a High Altitude Science Eagle Flight Computer with a temperature pressure sensor ran independently, writing data to an SD card. All of these modules were powered by a 5 mAh lithium polymer battery. The battery was attached to the bottom of the payload while the remaining electronics were embedded in the underside of the top of the payload. These modules were wired as seen in Figure 1-2. The Iteaduino Mega microcontroller board was programmed to use the RockBLOCK to send a message once every 10 minutes containing neutron and GPS data read off the NEMO and SAM M8Q, respectively. Once the message send attempt finished, the RockBLOCK would be slept for the rest of the 10 minute interval. The Eagle Flight Computer ran continuously throughout the flight, taking data every 6 seconds. The RockBLOCK message data was set up to be delivered from the Iridium satellite fleet to a website, where it was stored and parsed to create live maps and plots for analysis and balloon retrieval. The RockBLOCK message data was additionally configured to be sent to an email as a fail-safe. The payload was ground-tested successfully for over 50 hours, with multiple revisions occurring to best prepare for conditions at altitude and improve the software and firmware to fix any issues that cropped up with the data pipeline. Additional to the balloon payload, the flight had an attached iMet-4 radiosonde and Garmin T5 GPS Dog Collar. The radiosonde provided GPS and meteorological data. The T5 dog collar is used along with a Garmin Astro 430 to track the balloon at a range of up to 9 miles for retrieval. The balloon itself was initially a 1600 g meteorological balloon with an attached High Altitude Science parachute, both of which can be seen in Figure 1-3. After the first flight, the EES team swapped to a Rocketman parachute.

42 ENGINEERING↗

Radiation-Hardened GaN HEMT and Cell Design, Modeling, and Fabrication for Nuclear Instrumentation Applications

Recent advances in nuclear power generation technologies show great promise for efficient, safe generation of carbon-free power in the near future. Consequently, many new generation reactor designs are being pursued by government and industry groups, including both fission- and fusion-based technologies. Radiation- and temperature-tolerant sensor technology continues to advance, yet development of the electronics/instrumentation technologies suitable for these environments have fallen behind. Industry has adequately addressed harsh environment electronics needs for low earth orbit satellites, but the much more extreme conditions associated with electronics placed near or in a reactor core remain unaddressed. This project investigates the use of gallium nitride (GaN) circuit technology to address the unique needs for sensor interface electronics and communications in reactor environments. This report provides a summary of the first year’s project activities related to developing and optimizing devices and circuits for this GaN high electronic mobility transistor (HEMT) process. Activities reported include multiple analog and digital circuit designs simulated using custom Verilog-A models generated from measured GaN devices fabricated in the target process. Digital circuit designs included fundamental logic circuits such as an inverter, NAND, NOR, AND and OR gates, as well as a 5-stage ring oscillator. Each design was simulated using an open-source SPICE simulator, and an integrated circuit layout was produced of each design for use in future fabrication. Analog circuit designs focused on the fundamental building blocks to be used to construct sensor interface and communications circuits. These included current mirrors, matched differential pairs, and a Gilbert cell mixer design, each with an associated integrated circuit layout. Layout tools used for these designs included two open-source packages—KLayout and Magic—which were customized for specific use with the OSU GaN process layers. Design rules and preliminary device extraction capabilities were built for the Magic tool to enable device extraction and subsequent netlist generation for SPICE simulation. Finally, future research directions for year two are summarized. When the year-two directions are implemented, the project will be in position to advance the state of the art in electronics for near- or in-reactor sensor interfacing and communications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Smokeless Chimney using Smoke Opacity as a Combustion Control Parameter (CRADA Final Report)

If operated poorly, wood burning heaters can produce large amounts of particulate matter (PM). Although several instruments are available to monitor PM, most require dilution air and are unable to sample directly from a flue due to the high PM concentrations and temperatures. Opacity sensors can measure color, opacity and smoke density from wood heater stacks. They operate by transmitting a light beam through the emission source and measuring the amount of light intensity lost (opacity) and light not reflected (color). Although opacity sensors are used in several areas, none have been thoroughly evaluated or optimized for measuring smoke from wood heaters.

47 OTHER INSTRUMENTATION↗

Implementation of Johnson Noise Thermometry into Radiation Hardened Electronics

The random motion of charge carriers in an electrical conductor is a function of its temperature. This phenomenon generates an electrical signal, referred to as Johnson noise, that is present in all analog signals. Conversely, the temperature dependence of the Johnson noise spectrum also enables a direct measurement of absolute temperature, which can provide a secondary measurement of temperature when quantified using sensors such as resistive temperature devices (RTDs) in a process called Johnson noise thermometry (JNT). For nuclear environments, this is of particular interest in correcting for RTDs signal drift caused by accumulation, transmutation, and displacement damage caused by neutron and gamma irradiation.

42 ENGINEERING↗

High-temperature irradiation-resistant thermocouple instability model for in-pile reactor use

This article presents an instability model for the high-temperature irradiation-resistant thermocouple (HTIR-TC). Here the term instability defines the superposition of both drift and inhomogeneity of TC thermoelements occurring simultaneously. The HTIR-TC is an advanced thermocouple (TC) that uses the refractory metals niobium and molybdenum as sensing thermoelements for generating electromotive force (EMF) in a field of neutrons and at temperatures upward of 1,600°C. In the Advanced Gas Reactor (AGR) 5/6/7 tests conducted at Idaho National Laboratory’s Advanced Test Reactor (ATR), the HTIR-TCs showed low to moderate instability throughout the life of the test. The instability model reveals that HTIR-TCs can, when the operating temperature of the reactor fuel is normal, maintain performance throughout an 18-month refueling cycle typical of nuclear power plants, reflecting an instability of less than ±1%. The HTIR-TC is also qualified for incorporation into a test fixture during the testing of new fuels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Miniature Cathode Ray Magnetometer

In this study, we introduce the concept and construction of an innovative Digital Miniature Cathode Ray Magnetometer designed for the precise detection of magnetic fields. This device addresses several limitations inherent to magnetic probes such as D.C. offset, nonlinearity, temperature drift, sensor aging, and the need for frequent recalibration, while capable of operating in a wide range of magnetic fields. The core principle of this device involves the utilization of a charged particle beam as the sensitivity medium. The system leverages the interaction of an electron beam with a scintillator material, which then emits visible light that is captured by an imager. The emitted scintillation light is captured by a CMOS sensor. This sensor not only records the scintillation light but also accurately determines the position of the electron beam, providing invaluable spatial information crucial for magnetic field mapping. The key innovation lies in the combination of electron beam projection, CMOS imager scintillation-based detection, and digital image signal processing. By employing this synergy, the magnetometer achieves remarkable accuracy, sensitivity and dynamic range. The precise position registration enabled by the CMOS sensor further enhances the device’s utility in capturing complex magnetic field patterns, allowing for 2D field mapping. In this work, the optimization of the probe’s performance is tailored for applications related to the characterization of insertion devices in light sources, including undulators.

Turqueti, Marcos↗

Initial Temperature Testing of Advanced Manufactured Melt Wire Package

As a part of the In-Pile Instrumentation Program, The Idaho National Laboratory (INL) has recently established in-house capabilities to fabricate and test new advanced manufactured sensors for measuring the peak irradiation temperature inside a nuclear test reactor. Although nuclear test reactors can use standard methods of real-time temperature monitoring, such as thermocouples, the complexity of feedthroughs and attachment complications to collect real-time measurements greatly increases the cost of the experiment. Passive monitoring techniques may be utilized that exploit the melting point of well characterized material (standard melt wires), however, the limited space available for instrumentation during experiments is also a challenge. To accommodate the challenge, INL has expanded its temperature detection instrumentation capabilities paired with the advancement of in-house advanced manufacturing options to include printed melt wires for peak irradiation temperature measurement. The advanced manufactured melt wire package can determine peak temperatures in experiments that can fit the challenging space available during irradiation. Recent results and knowledge from this ongoing work have made it possible to develop unique temperature sensors that can accomplish user specific temperature ranges inside the harsh environments experienced during radiation testing. This report summarizes the initial temperature testing using fabricated melt wires with two different melting temperatures, silver (melting temperature of ~960 °C) and solder (melting temperature of ~160 °C), that were initially tested for their relative melting points using non-standard method of furnace and hot plate testing under normal air conditions. Future work will include more controlled way of testing printed melt wires under inert gas with multiple temperature measurements followed by comparison of standard melt wire package performance for baseline characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast response High Altitude Laser Optical Sensor (HALOS) for atmospheric water and temperature measurements

Advanced instrumentation and sensing methods are the key factor in the determination of many climate science research problems. In this Phase I STTR a laser-based diagnostic system for atmospheric temperature and water concentrations measurements was developed, this system, HALOS – High Altitude Laser Optical Sensor, employs a mid-infrared (MIR) quantum cascade laser (QCL) of the distributed feedback variety (DFB) powered by a 100 kHz rep rate ramp modulated current profile which enables spectral profiling. Measurements made during Phase I showed that HALOS can surpass the available hygrometers refresh rates while offering superior accuracy (<4%) from the low Frost Point (Tfrost) of -110°C to dew points (Tdew) at 35°C while being able to encompass sub ppm concentration at altitude and supersaturated conditions at ground level. Readings from HALOS include temperature sensitivity on the order of 0.2°C and absolute humidity sensitivity (AH) on the order of 0.010 μmol/m 3 (0.18 mg/m 3 ) at a data output rate exceeding 1 kHz. HALOS can be easily integrable in existing Department of Energy (DOE) or National Oceanic and Atmospheric Administration (NOAA) conventional or remote operated aircraft having either a fixed or rotary wing.

54 ENVIRONMENTAL SCIENCES↗

Multicomponent Nanoparticle Synthesis for Advanced Manufactured Melt Wire Development

Additive manufacturing (AM) based direct-write technologies have emerged as a predominant enabler for the fabrication of advanced passive sensors in-pile applications. This work continues previous efforts with the modification and optimization of synthesis methods for multi-component nanoparticle systems used to support the development, fabrication and testing of AM sensors for peak temperature detection. For this report, bismuth, bismuth/platinum, tin, tin/silver, tin/zinc, indium, and indium/silver bi-metallic nanoparticles were synthesized using the wet chemical methods. The nanoparticles were then characterized with x-ray fluorescence to evaluate the elemental composition and differential scanning to determine the melting point and mass loss of the samples. Results continue to show that bi-metallic nanoparticles are a viable pathway for the fabrication of high-resolution AM melt wires.

36 MATERIALS SCIENCE↗

Demonstration of Embedded Sensors in Ceramic Structures

The Transformational Challenge Reactor (TCR) program seeks to demonstrate an advanced 3D printed nuclear reactor core. A binder jet additive manufacturing process is used to fabricate the complex SiC ceramic components of the TCR core. After printing, the components are densified via chemical vapor infiltration (CVI). This process allows complex cavities to be created in which sensors can be placed at strategic locations. Inserting the sensors during the CVI process allows the sensors to be embedded within the component as it is infiltrated. The primary challenge for embedding the sensors is identifying the sensors and sensor sheath materials that can survive the temperatures (>1,000°C) and chemical exposure to H 2 and HCl during CVI. The embedded sensors that are being investigated for use during TCR operation include thermocouples, self-powered neutron detectors, and spatially distributed fiber-optic temperature sensors. This report describes the CVI materials compatibility tests and initial trials for embedding functional sensors. Mo is identified as the most suitable sensor sheath material based on its availability in small diameter tubing, relatively low neutron absorption cross section, and compatibility with H 2 , HCl, and the surrounding SiC matrix at the process temperatures. Amorphous SiO2 fiber-optic samples with Au and Cu metal coatings were successfully embedded in SiC along with bare fibers, although the metal coatings showed some evidence of localized melting during CVI. Initial experiments attempting to embed functional sensors showed that the sensors can be embedded in 3D printed SiC parts, but there are still challenges that must be overcome to ensure that the sensors and sensor sheaths do not fail during CVI. In particular, Nb-sheathed Mo-Nb thermocouples failed at temperatures far lower than expected despite thermodynamic calculations and materials compatibility tests that show the Nb sheath to be compatible with the CVI environment. One potential explanation for the large expansion of the Nb sheath could be related to hydride formation in the lower temperature region of the sheath. Future work will focus on Mo-sheathed thermocouples instead of Nb. The fiberoptic sensors tested during the instrumented experiment broke due to the lack of mechanical protection after their polymer-based coatings were vaporized. Future instrumented experiments will use metal-coated optical fibers for strain sensing to provide additional mechanical protection. However, custom coatings with higher melting points than commercially available Au and Cu might be required. Regardless, fiber-optic sensors are still candidates for spatially distributed temperature measurements since they can be inserted into an embedded metal sheath after CVI.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensor-Equipped Unmanned Surface Vehicle for High-Resolution Mapping of Water Quality in Low- to Mid-Order Streams

Longitudinal profiling of water quality via the deployment of sensors from watercraft has advanced the understanding of spatial patterns in large rivers and lakes; however, a similar approach in low- to mid-order streams is lacking. To fill this gap, we developed an unmanned surface vehicle (USV)-water quality measurement platform (the “AquaBOT”). The components of the AquaBOT included a nitrate sensor, multiparameter sonde (temperature, conductivity, turbidity, dissolved oxygen, chlorophyll), quantum sensor, and global positioning system (GPS) mounted to a small pontoon-style USV. The AquaBOT was tested in four streams and rivers in Iowa and Tennessee. All measured water quality parameters varied longitudinally, and greater ranges were generally observed along the low-order, agriculturally influenced streams in Iowa. Nitrate, in particular, was spatially heterogeneous. For example, during one run in early June, concentrations ranged from 10.5 to 12.5 mg N L –1 along a 2.3 km reach and hotspots were observed directly downstream of some tile drains. The spatial resolution of AquaBOT data collected in June was 10× higher than grab sampling data, and measurements were collected in less time and at a comparable cost. Here, the AquaBOT can complement existing measurement approaches and will lead to advancements in understanding the processes driving water quality along the stream-to-river continuum.

47 OTHER INSTRUMENTATION↗

Effects of Charged Solute-Solvent Interaction on Reservoir Temperature during Subsurface CO2 Injection

A short-term side-effect of CO2 injection is a developing low-pH front that forms ahead of the bulk water injectant, due to differences in solute diffusivity. Observations of downhole well temperature show a reduction in aqueous-phase temperature with the arrival of a low-pH front, followed by a gradual rise in temperature upon the arrival of a high concentration of bicarbonate ion. In this work, we model aqueous-phase transient heat advection and diffusion, with the volumetric energy generation rate computed from solute-solvent interaction using the Helgeson–Kirkham–Flowers (HKF) model, which is based on the Born Solvation model, for computing specific molar heat capacity and the enthalpy of charged electrolytes. A computed injectant water temperature profile is shown to agree with the actual bottom hole sampled temperature acquired from sensors. The modeling of aqueous-phase temperature during subsurface injection simulation is important for the accurate modeling of mineral dissolution and precipitation because forward dissolution rates are governed by a temperature-dependent Arrhenius model.

58 GEOSCIENCES↗

Metal-embedded optical fibers for monitoring pressure or corrosion at high temperatures

A fiber optic sensor and a related method of manufacture are provided. The fiber optic sensor includes an embedded optical fiber contained within a metal diaphragm assembly, where the terminal end of the optical fiber is positioned opposite a diaphragm. The method includes forming a metal-embedded optical fiber by ultrasonic additive manufacturing and securing the metal-embedded optical fiber to a housing having a diaphragm that is opposite of the terminal end of the optical fiber. The sensor can provide extremely accurate pressure measurement at high temperatures and in highly corrosive media. An optical fiber-based pressure sensing system is also provided.

Petrie, Christian M.↗