Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Fallon FORGE: Geophysics and Geochemistry

The data is associated to the Fallon FORGE project and includes mudlogs for all wells used to characterize the subsurface, as wells as gravity, magnetotelluric, earthquake seismicity, and temperature data from the Navy GPO and Ormat. Also included are geologic maps from the USGS and Nevada Bureau of Mines and Geology for the Fallon, NV area.

15 GEOTHERMAL ENERGY↗

Thermoelastic Properties of Eclogitic Garnets and Omphacites: Implications for Deep Subduction of Oceanic Crust and Density Anomalies in the Upper Mantle

In this work, synchrotron-based high-pressure/high-temperature single-crystal X-ray diffraction experiments to ~24 GPa and 700 K were conducted on eclogitic garnets (low-Fe: Prp 28 Alm 38 Grs 33 Sps 1 and high-Fe: Prp 14 Alm 62 Grs 19 Adr 3 Sps 2 ) and omphacites (low-Fe: Quad 57 Jd 42 Ae 1 and high-Fe: Quad 53 Jd 27 Ae 20 ), using an externally heated diamond anvil cell. Fitting the pressure-volume-temperature data to a third-order Birch-Murnaghan equation of state yields the thermoelastic parameters including bulk modulus ($K_{T0}$), its pressure derivative ($K'_{T0}$), temperature derivative (($∂K_T/∂T)_P$), and thermal expansion coefficient ($α_T$). The densities of the high-Fe and low-Fe eclogites were then modeled along typical geotherms of the normal mantle and the subducted oceanic crust to the transition zone depth (550 km). The metastable low-Fe eclogite could be a reason for the stagnant slabs within the upper range of the transition zone. Eclogite would be responsible for density anomalies within 100–200 km in the upper mantle of Asia.

58 GEOSCIENCES↗

Quantitatively Monitoring Bubble-Flow at a Seep Site Offshore Oregon: Field Trials and Methodological Advances for Parallel Optical and Hydroacoustical Measurements

Two lander-based devices, the Bubble-Box and GasQuant-II, were used to investigate the spatial and temporal variability and total gas flow rates of a seep area offshore Oregon, United States. The Bubble-Box is a stereo camera–equipped lander that records bubbles inside a rising corridor with 80 Hz, allowing for automated image analyses of bubble size distributions and rising speeds. GasQuant is a hydroacoustic lander using a horizontally oriented multibeam swath to record the backscatter intensity of bubble streams passing the swath plain. The experimental set up at the Astoria Canyon site at a water depth of about 500 m aimed at calibrating the hydroacoustic GasQuant data with the visual Bubble-Box data for a spatial and temporal flow rate quantification of the site. For about 90 h in total, both systems were deployed simultaneously and pressure and temperature data were recorded using a CTD as well. Detailed image analyses show a Gaussian-like bubble size distribution of bubbles with a radius of 0.6–6 mm (mean 2.5 mm, std. dev. 0.25 mm); this is very similar to other measurements reported in the literature. Rising speeds ranged from 15 to 37 cm/s between 1- and 5-mm bubble sizes and are thus, in parts, slightly faster than reported elsewhere. Bubble sizes and calculated flow rates are rather constant over time at the two monitored bubble streams. Flow rates of these individual bubble streams are in the range of 544–1,278 mm 3 /s. One Bubble-Box data set was used to calibrate the acoustic backscatter response of the GasQuant data, enabling us to calculate a flow rate of the ensonified seep area (~1,700 m 2 ) that ranged from 4.98 to 8.33 L/min (5.38 × 10 6 to 9.01 × 10 6 CH 4 mol/year). Such flow rates are common for seep areas of similar size, and as such, this location is classified as a normally active seep area. For deriving these acoustically based flow rates, the detailed data pre-processing considered echogram gridding methods of the swath data and bubble responses at the respective water depth. The described method uses the inverse gas flow quantification approach and gives an in-depth example of the benefits of using acoustic and optical methods in tandem.

54 ENVIRONMENTAL SCIENCES↗

ECAR-5633 AGR-5/6/7 Daily As-Run Thermal Analyses

The purpose of this engineering and calculations report is to document the results of the thermal analyses performed to calculate the Advanced Gas-Cooled Reactor (AGR)-5/6/7 as-run daily temperatures of the fuel compacts. Temperature data provided by this report will be used to evaluate fuel performance. The AGR-5/6 portion of the experiment was for fuel qualification at prototypic temperatures, while the AGR-7 portion of the experiment was a margin test at very high temperatures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Winter-responding proxy temperature reconstructions and the North Atlantic Oscillation

Instrumental temperature data for the Northern Hemisphere (30°–90°N) clearly indicate that winter season variability is larger than equivalent measures for summer. This should not be surprising as temperatures in winter are dominated by variability caused by changes in atmospheric circulation features, whereas in summer variability is more dominated by local changes in cloudiness. Here we consider most of the few winter-responding annually resolved proxy reconstructions of temperature from the northern North Atlantic and northwestern European regions. We find the expected out-of-phase relationship between northwest Europe and Greenland due to the North Atlantic Oscillation (NAO), which is stronger when the series from the two locations are formed from more than one series. On 3 year time scales this relationship between the two locations shows no century-scale variations since 1250 CE (Common Era), the start of our reconstructions, in contrast to the strong positive NAO values before 1400 CE implied by the study of Trouet et al. (2009).

54 ENVIRONMENTAL SCIENCES↗

CMB polarization features from inflation versus reionization

The angular power spectrum of the cosmic microwave background temperature anisotropy observed by WMAP has an anomalous dip at l{approx}20 and a bump at l{approx}40. One explanation for this structure is the presence of features in the primordial curvature power spectrum, possibly caused by a step in the inflationary potential. The detection of these features is only marginally significant from temperature data alone. However, the inflationary feature hypothesis predicts a specific shape for the E-mode polarization power spectrum with a structure similar to that observed in temperature at l{approx}20-40. Measurement of the CMB polarization on few-degree scales can therefore be used as a consistency check of the hypothesis. The Planck satellite has the statistical sensitivity to confirm or rule out the model that best fits the temperature features with 3{sigma} significance, assuming all other parameters are known. With a cosmic variance limited experiment, this significance improves to 8{sigma}. For tests of inflationary models that can explain both the dip and the bump in temperature, the primary source of uncertainty is confusion with polarization features created by a complex reionization history, which, at most, reduces the significance to 2.5{sigma} for Planck and 5{sigma}-6{sigma} for an ideal experiment. Smoothing of the polarization spectrum by a large tensor component only slightly reduces the ability of polarization to test for inflationary features, as does requiring that polarization is consistent with the observed temperature spectrum, given the expected low level of TE correlation on few-degree scales. If polarized foregrounds can be adequately subtracted, Planck will supply valuable evidence for or against features in the primordial power spectrum. A future high-sensitivity polarization satellite would enable a decisive test of the feature hypothesis and provide complementary information about the shape of a possible step in the inflationary potential.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal Effusivity Tomography from Pulsed Thermal Imaging

The software program generates 3D volume distribution of thermal effusivity within a test material from one—sided pulsed thermal imaging data. Thsi is the first software capable of accurate, fast and automated thermal tomographic imaging of inhomogeneoirs materials to produce 3D images similar to those obtained from 3D X—ray CT (all previous thepnal—imaging software can only produce 20 results) . Because thermal effusivity is an Intrisic material property that is related to material constituent, density, conductivity, etc., quantitative imaging of eftusivity allowed direct visualization of material’s internal constituent/structure and damage distributions, thereby potentially leading to quantitative prediction of other material properties such as strength. I can be therefre be used for 3D imaging of material structure in fundamental material studies, nondestructive characterization of defects/flaws in structural engineering components, health monitoring of material damage and degradation during service, and medical imaging and diagnostics. This technology is one—sided, non contact and sensitive to material’s thermal property and discontinuity. One major advantage of this tomographic technology over x-ray CT and ultrasounds is its natural efficiency for 3D imaging of the volume under a large surface area. This software is implemented with a method for thermal computed tomography of thermal effusivity from one—sided pulsed thermal imaging (or thermography) data. The method is based on several solutions of the governing heat transfer equation under pulsed thermography test condition. In particular, it consists of three components. 1) It utilized the thermal effusivity as the imaging parameter to construct the 3D image. 2) It established a relationship between the space (depth) and the time, because thermography data are in the time domain. 3) It incorporated a deconvolution algorithm to solve the depth porfile of the material thermal effusivity from the measured (temporal) surface temperature data. The predicted effusivity is a direct function of depth, not an average or convolved parameter, so it is an accurate (and more sensitive) representation of local property along depth.

Sun, Jiangang↗

Configurational entropy of polar glass formers and the effect of electric field on glass transition

A model of low-temperature polar liquids is constructed that accounts for the configurational heat capacity, entropy, and the effect of a strong electric field on the glass transition. The model is based on the Padé-truncated perturbation expansions of the liquid state theory. Depending on parameters, it accommodates an ideal glass transition of vanishing configurational entropy and its avoidance, with a square-root divergent enumeration function at the point of its termination. A composite density-temperature parameter ρ{sup γ}/T, often used to represent combined pressure and temperature data, follows from the model. The theory is in good agreement with the experimental data for excess (over the crystal state) thermodynamics of molecular glass formers. We suggest that the Kauzmann entropy crisis might be a signature of vanishing configurational entropy of a subset of degrees of freedom, multipolar rotations in our model. This scenario has observable consequences: (i) a dynamical crossover of the relaxation time and (ii) the fragility index defined by the ratio of the excess heat capacity and excess entropy at the glass transition. The Kauzmann temperature of vanishing configurational entropy and the corresponding glass transition temperature shift upward when the electric field is applied. The temperature shift scales quadratically with the field strength.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mathematical modeling of gas desorption from a metal–organic supercontainer cavity filled with stored N 2 gas at critical limits

Metal–organic supercontainer (MOSC) molecules are ideal candidates for gas storage applications due to their construction with customizable ligands and tunable cavity and window sizes, which are found to be elastic in nature. Force field molecular dynamics (MD) are used to evaluate the utilization of MOSCs as nanoporous structures for gas storage. A MOSC, with nitrogen gas molecules filling the cavity, progresses through MD and releases gas molecules by applying temperature to the MOSC. It is the MOSC's elasticity which is responsible for the desorption of guests at elevated temperatures. Data obtained from MD serves as a guide for the derivation of analytical equations that can be used to describe and explain the mechanism of gas desorption from within the cavity. Mathematical modeling of gas desorption from the center cavity can provide a method of predicting MOSC behavior for a broader range of pressures and temperatures, which is challenging for direct atomistic modeling. The utilization of MD can provide data for a wide variety of properties and processes in various materials under different conditions for a broad range of technology-related applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Multilayer Reservoir Thermal Stratification Module for Earth System Models

Thermal stratification in reservoirs is a critical process that regulates downstream riverine energy and biogeochemical cycling. Current stratification models either simplify reservoir geometry or neglecting the effects of reservoir operation. Here we present a new multi-layer reservoir stratification model that can be coupled to earth system models at regional or global scale. With a multi-layer vertical discretization, we introduce a newly developed storage-area-depth dataset to improve parameterization of advection processes in and out of the reservoir. The new model better represents vertical temperature gradient and subsequently temperature of water released to downstream. The stratification model is applied to 1400 reservoirs over the contiguous US and validated against observed surface, profile, and outflow temperature data over 130 reservoirs subjected to various levels of regulation. The Nash-Sutcliffe values are higher than 0.5 for about 77% of the validated reservoirs using surface temperature while the average values of root mean square error and bias are 3.6oC and -1.1oC, respectively. Using the new reservoir storage-area-depth dataset improves the simulation of surface temperature at over 69% of the validated reservoirs compared to using simplified reservoir geometry. The reservoir stratification model contributes to improving predictive understanding of anthropogenic impact on terrestrial hydrological, ecological and biogeochemical cycles.

Yigzaw, Wondmagegn↗

Evaluation of a low-cost and accurate ocean temperature logger on subsurface mooring systems

Monitoring seawater temperature is important to understanding evolving ocean processes. To monitor internal waves or ocean mixing, a large number of temperature loggers are typically mounted on subsurface mooring systems to obtain high-resolution temperature data at different water depths. In this study, we redesigned and evaluated a compact, low-cost, self-contained, high-resolution and high-accuracy ocean temperature logger, TC-1121. The newly designed TC-1121 loggers are smaller, more robust, and their sampling intervals can be automatically changed by indicated events. They have been widely used in many mooring systems to study internal wave and ocean mixing. The logger’s fundamental design, noise analysis, calibration, drift test, and a long-term sea trial are discussed in this paper.

Internal waves, Ocean mixing, Temperature loggers,↗

We Just Want to Pump…You Up! Forecasting Grid-Connected Heat Pump Water Heater Energy Savings and Load Shifting Potential for the Southeast U.S.

Heat pump water heaters (HPWH) can achieve energy savings of 60-70% compared to conventional electric-resistance water heaters. However, even with a favorable simple payback period within the typical product lifetime, HPWHs make up only 1% of all electric water heaters sold in the residential sector. Market adoption is challenged, in part, by the lack of effective energy efficiency programs in the U.S. region with the greatest amount of residential electric water heaters. The recent integration of connected functionality into HPWHs offers the capability to shift load without undue negative impact on customers. This capability can provide value to utilities with peak load constraints, motivating them to promote HPWHs for the first time. This paper will present a methodology to forecast connected HPWH energy use and extrapolate load shifting potential for the Southeast U.S. region. The methodology leverages data from a robust connected HPWH field study conducted in the Pacific Northwest. A coefficient of performance (COP) relationship for HPWHs was developed using ambient and inlet water temperature data to forecast HPWH performance on a month-by-month basis. Using the forecasted COP, HPWH operating hours were calculated for meeting load, which serve as the proxy to extrapolate load shifting potential from the Pacific Northwest to the Southeast. As a use case, analytical results are presented for a specific utility. This methodology, in combination with market analysis, facilitates the development of customized energy savings and load shifting forecasts to understand the potential impacts of launching connected HPWH programs in specific utility service territories.

heat pump water heater, energy savings, load shift↗

Oxide Film and Porosity Defects in Magnesium Alloy AZ91

Porosity is a major concern in the production of light metal parts. This work aims to identify some of the mechanisms of microporosity formation in magnesium alloy AZ91. Microstructure analysis was performed on several samples obtained from gravity-poured ingots in graphite plate molds. Temperature data during cooling was acquired with type K thermocouples at 60 Hz at three locations of each casting. The microstructure of samples extracted from the regions of measured temperature was then characterized with optical metallography. Tensile tests and conventional four point bend tests were also conducted on specimens cut from the cast plates. Scanning electron microscopy was then used to observe the microstructure on the fracture surface of the specimens. The results of this study revealed the existence of abundant oxide film defects, similar to those observed in aluminum alloys. Remnants of oxide films were detected on some pore surfaces, and folded oxides were observed in fracture surfaces indicating the presence of double oxides entrained during pouring.

36 MATERIALS SCIENCE↗

Computational and Experimental Validation of Fractal-Fin, Dimpled Solar Heat Collector

A 3 foot x 3 foot x 3 foot aluminum solar collector was manufactured using computer numerical control. The interior of the device included six triangular dimpled fins for enhanced heat transfer. The interior vertical wall on the south side was also dimpled. The solar collector working fluid was based on water, and the collector consisted solely of passive heat transfer mechanisms (no moving parts), making it ideal for off-the-grid and rural applications. Two types of heat transfer experiments were conducted. One experiment had external flat heaters attached on the top and the front side, while the other four sides were insulated. Except for the bottom surface, the second experiment had all its exterior surfaces sprayed with black solar paint to collect as much solar heat as possible. Temperature data as a function of time was collected using 14 thermocouples spread strategically throughout the solar collector. In addition, computational fluid dynamics (CFD) simulations were conducted using the dynamic Smagorinsky large eddy simulation turbulence model. The first simulation considered that both the top and front surfaces were exposed to a fixed temperature of 313.7 K (105 °F), while the remaining four surfaces were insulated. For the second simulation, all conditions were the same, except that the temperature for both heated surfaces was raised to 350 K (170.3 °F). The two temperatures are expected to bound the solar collector operational temperature during the late- Spring, Summer, and early-Fall months. The solar collector design, experimental data, CFD output, and a discussion of five manufacturing approaches and costs are documented in this report.

14 SOLAR ENERGY↗

Soil water content, matric potential, carbon dioxide and oxygen concentrations, Oct 2018-Dec 2021, Slate River Floodplain, Crested Butte, Colorado

This data package includes a time series of soil sensor data (temperature, water content, bulk electrical conductivity, porewater dissolved oxygen and porewater dissolved carbon dioxide) in a vertical profile from the Slate River floodplain outside Crested Butte, Colorado, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? The package includes: (1) soil temperature, volumetric water content and electrical conductivity at 40, 60 and 82.5 cm depth; (2) soil matric potential at 40, 60, 79 and 100 cm depth; (3) soil CO2 concentrations at 40, 60 and 82.5 cm depth; and (4) soil oxygen concentrations at 60, 82.5, 100, 135, 170 and 182 cm depth. Both the carbon dioxide and oxygen sensors are optical sensors that can measure the partial pressure of oxygen in both saturated and unsaturated conditions. Unfortunately, soil CO2 in the profile is unexpectedly high and above the sensor calibration range (0-25,000 ppm). In addition, soil CO2 sensors failed within a year of deployment, so we only report CO2 data from 2019-2020.Within the data package, "FLMD.csv" describes file-level metadata and "dd.csv" defines column headers and universal terms across the dataset. The data package includes 4 "*data.csv" files, one for each calendar year in the dataset. Each "*data.csv" file has a corresponding "*_InstallationMethods.csv" file that describes the location, sensor model, sensor serial number and other metadata corresponding for each measured parameter. Because sensors have been added over time, not every sensor has data dating back to Oct 2018. Note that there is a data gap over winter 2019-2020 due to a power outage. While this repository currently only contains data through December 2021, the dataset will be updated as additional years are collected and processed.

54 ENVIRONMENTAL SCIENCES↗

Reconstruction of Central European daily weather types back to 1763

Weather type classifications (WTCs) are a simple tool to analyse variations in weather patterns. Long series of WTCs could be used to address decadal changes in weather as a basis for studying changes in variability or extremes or for addressing contributions of sea-surface temperature or external forcings using climate models. However, there is no long series of daily objective weather types (WTs). A new method (Shortest Mahalanobis Distance, SMD) using daily European weather data is developed to reconstruct WTCs back in time. Here the SMD method is applied on the Cluster Analysis of Principal Components (CAP9) classification used by MeteoSwiss. The CAP9 daily WT time series (computed with ERA-40) is used as reference over the 1958–1998 period. Daily data (temperature, mean sea level pressure and pressure tendency) from 13 European stations covering the period 1763–2009 are used for the reconstruction. The reference CAP9 is reduced from nine to seven types so the new daily WTC is called CAP7. As an assessment, CAP7 is compared to the original classification CAP9 and to the same WTs computed with the Twentieth Century Reanalysis (20CR and 20CRv2c). Over the reference period up to 90% of all the daily WTs can be correctly reproduced in the new WTC compared to the original series, with higher reliability in winter than in summer. In addition, the reliability of the classification is increasing from 1763 onward. The annual occurrence of each type reveals some trends, mostly a decrease in the number of cyclonic days and an increase of cyclonic days.

54 ENVIRONMENTAL SCIENCES↗

Microstructure and high temperature tensile properties of 316L fabricated by laser powder-bed fusion

316L stainless steel fabricated by laser powder-bed fusion (LPBF) has attracted significant attention due to a unique combination of strength and ductility at room temperature. Understanding of high temperature tensile properties of LPBF fabricated 316L is, however, limited. In the present investigation, tensile testing was conducted at 20–700ºC on LPBF 316L in as printed condition and after annealing for 5 h at 500–800ºC. Room temperature data confirmed the excellent ductility of the LPBF-processed 316L steel due to the cellular structure with high dislocation density. However, a significant decrease in ductility was observed at temperatures above 200ºC. These results are consistent with a change of deformation mechanisms observed in wrought 316L, with twinning playing a key role at room temperature. Finally, microstructure characterization and tensile testing revealed that the cellular structure is stable up to 500ºC, but a decrease of yield strength was observed at temperatures above 600ºC likely due to a decrease in dislocation density via annealing.

36 MATERIALS SCIENCE↗

Interdependence between Cooling Rate, Microstructure and Porosity in Mg Alloy AE42

Porosity is a major concern in the production of light metal parts. This work aims to identify some of the mechanisms of microporosity formation during the gravity-poured castings of magnesium alloy AE42. Two graphite plate molds and a ceramic cylindrical mold were selected to produce a wide range of cooling rates. Temperature data during cooling was acquired with type K thermocouples at 60 Hz at two or three locations of each casting. The microstructure of samples extracted from the regions of measured temperature was then characterized with optical metallography. The results of this study revealed the existence of oxide film defects, similar to those observed in aluminum alloys. The cooling rates showed significant effect on the formation of porosity.

36 MATERIALS SCIENCE↗