Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “targeted imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

DESI z ≳ 5 Quasar Survey. I. A First Sample of 400 New Quasars at z ~ 4.7–6.6

We report the first results of a high-redshift (z ≳ 5) quasar survey using the Dark Energy Spectroscopic Instrument (DESI). As a DESI secondary target program, this survey is designed to carry out a systematic search and investigation of quasars at 4.8 < z < 6.8. The target selection is based on the DESI Legacy Imaging Surveys (the Legacy Surveys) DR9 photometry, combined with the Pan-STARRS1 data and J-band photometry from public surveys. A first quasar sample has been constructed from the DESI Survey Validation 3 (SV3) and first-year observations until 2022 May. This sample includes more than 400 new quasars at redshift 4.7 ≤ z < 6.6, down to 21.5 magnitude (AB) in the z band, discovered from 35% of the entire target sample. Remarkably, there are 220 new quasars identified at z ≥ 5, more than one-third of existing quasars previously published at this redshift. The observations so far result in an average success rate of 23% at z > 4.7. The current spectral data set has already allowed analysis of interesting individual objects (e.g., quasars with damped Lyα absorbers and broad absorption line features), and statistical analysis will follow the survey's completion. A set of science projects will be carried out leveraging this program, including quasar luminosity function, quasar clustering, intergalactic medium, quasar spectral properties, intervening absorbers, and properties of early supermassive black holes. Additionally, a sample of 38 new quasars at z ~ 3.8–5.7 discovered from a pilot survey in the DESI SV1 is also published in this paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep learning-based noise filtering toward millisecond order imaging by using scanning transmission electron microscopy

Application of scanning transmission electron microscopy (STEM) to in situ observation will be essential in the current and emerging data-driven materials science by taking STEM’s high affinity with various analytical options into account. As is well known, STEM’s image acquisition time needs to be further shortened to capture a targeted phenomenon in real-time as STEM’s current temporal resolution is far below the conventional TEM’s. However, rapid image acquisition in the millisecond per frame or faster generally causes image distortion, poor electron signals, and unidirectional blurring, which are obstacles for realizing video-rate STEM observation. Here we show an image correction framework integrating deep learning (DL)-based denoising and image distortion correction schemes optimized for STEM rapid image acquisition. By comparing a series of distortion corrected rapid scan images with corresponding regular scan speed images, the trained DL network is shown to remove not only the statistical noise but also the unidirectional blurring. This result demonstrates that rapid as well as high-quality image acquisition by STEM without hardware modification can be established by the DL. The DL-based noise filter could be applied to in-situ observation, such as dislocation activities under external stimuli, with high spatio-temporal resolution.

47 OTHER INSTRUMENTATION↗

STILGAR End-of-Project Report

The Subsurface Tunnel Imaging LeveraGed by Analysis of Rayleigh wave ellipticity (STILGAR) project demonstrated an integrated geophysical approach for detecting, locating, and characterizing underground structural changes using dense seismic arrays and advanced inversion techniques. Field campaigns were conducted at two operational mines—the Redmond salt mine (Utah) and Graymont Pleasant Gap limestone mine (Pennsylvania)—providing real-world testbeds for monitoring anthropogenic subsurface activity. At the Redmond salt mine, seismic interferometry combined with back-projection inversion successfully identified continuous, low-amplitude signals from mining operations. The approach differentiated stationary from migrating anthropogenic sources, captured daily operational cycles, and validated the potential of passive seismic monitoring for remote detection of underground activity. At the Graymont Pleasant Gap mine, two dense seismic deployments in the spring and fall of 2023 generated over 4 TB of high-resolution data. Key outcomes included the relocation of 199 underground and 8 surface explosions with accuracies within tens of meters and the development of a 3D P-wave velocity model using the triple-difference tomography algorithm (tomoTD) that resolved major structural features such as the mine entrance, low-velocity tunnels, and roof-collapse areas. Ambient noise cross-correlation and back-projection analyses revealed persistent sources linked to ongoing mining activity, whereas horizontal-to-vertical spectral ratio (HVSR) and ellipticity studies confirmed stable site responses across seasons and identified soil thickness trends consistent with regional erosional and depositional processes. Checkerboard and sensitivity tests further validated the robustness of the tomographic results. Overall, the findings emphasize that although significant progress has been made in subsurface imaging, further work is needed to enhance the detection and localization of underground structures. Accurate imaging requires higher frequencies, yet anthropogenic sources tend to dominate the seismic record at those frequencies, and high-frequency surface waves are affected by higher modes that complicate interpretation. The improved detection and localization of human-induced signals enabled detailed temporal and spatial mapping of daily mine operations, demonstrating the feasibility of continuous anthropogenic source monitoring. Sensitivity to signals from nontraditional sources, such as fan operations, highlights the broader applicability of this approach to other industrial environments in which continuous and impulsive signals are present. The field campaigns produced a substantial volume of high-quality seismic data, supporting the development and testing of new methods for seismic source characterization and subsurface imaging. Future deployments should include sensors capable of recording lower frequencies to probe deeper structures, increase bandwidth to enhance resolution and sensitivity to both shallow and deep targets, and collect additional large-scale datasets to refine imaging and source characterization techniques. Moreover, conducting 3D modeling studies of seismic wavefields at higher frequencies will provide a better understanding of wave scattering and cavity–wavefield interactions in complex underground environments. In conclusion, the STILGAR project demonstrated that integrated seismic monitoring can effectively characterize underground operations, capturing both natural and anthropogenic signals. The approaches developed provide a foundation for improved detection, localization, and imaging of subsurface structures and are directly transferable to broader industrial monitoring applications.

58 GEOSCIENCES↗

Summary: SEE4GEO

The seismoelectric effects technique (SEE) is a new and innovative approach for geothermal subsurface imaging and monitoring at reservoir scale. The objective of this project is to assess SEE in terms of data acquisition, cost and quality, and to determine its capability in comparison with classical imaging and monitoring techniques, particularly decoupled seismic and electromagnetic methods. This will be achieved by (1) development of a fast, true 3D numerical package, handling SEE imaging and subsurface properties characterization, including resistivity and permeability, (2) laboratory experiments performed in a controlled environment to define optimal deployment design, data quality, and inform field deployment, and (3) field surveys to ultimately test and draw lessons for practical use of SEE technology. There is a relatively extensive body of work in the literature on SEE, and members of this consortium have been involved in theoretical and numerical development of SEE modeling as well as laboratory experiments. Nevertheless, to our knowledge few, if any, documented efforts have been specifically targeting the use of SEE for geothermal subsurface imaging and monitoring. The strength and originality of our proposal rely on an integrated approach leveraging numerical, laboratory and field experiments, to properly document the practical use of SEE. Through this process, SEE in-hand technology for the geothermal industry will be able to progress from a TRL 1 to TRL 3.

58 GEOSCIENCES↗

Seismoelectric Effects for Geothermal Resources Assessment and Monitoring (SEE4GEO)

The seismoelectric effects technique (SEE) is a new and innovative approach for geothermal subsurface imaging and monitoring at reservoir scale. The objective of this project is to assess SEE in terms of data acquisition, cost and quality, and to determine its capability in comparison with classical imaging and monitoring techniques, particularly decoupled seismic and electromagnetic methods. This will be achieved by (1) development of a fast, true 3D numerical package, handling SEE imaging and subsurface properties characterization, including resistivity and permeability, (2) laboratory experiments performed in a controlled environment to define optimal deployment design, data quality, and inform field deployment, and (3) field surveys to ultimately test and draw lessons for practical use of SEE technology. There is a relatively extensive body of work in the literature on SEE, and members of this consortium have been involved in theoretical and numerical development of SEE modeling as well as laboratory experiments. Nevertheless, to our knowledge few, if any, documented efforts have been specifically targeting the use of SEE for geothermal subsurface imaging and monitoring. The strength and originality of our proposal rely on an integrated approach leveraging numerical, laboratory and field experiments, to properly document the practical use of SEE. Through this process, SEE in-hand technology for the geothermal industry will be able to progress from a TRL 1 to TRL 3.

58 GEOSCIENCES↗

A Resonant Metamaterial Line Array for Ultrasound Compressive Imaging

Abstract Acoustic metamaterials have been proposed for numerous applications including subwavelength imaging, impedance matching, and lensing. Yet, their application in compressive sensing and imaging has not been fully investigated. When metamaterials are used as resonators at certain frequencies, they can generate random radiation patterns in the transmitted waves from the transducers and received waves from a target. Compressive sensing favors such randomness inasmuch as it can increase incoherence by decreasing the amount of mutual information between any two different measurements. This study aims at assessing whether the use of resonating metamaterial unit cells in a single-layered non-optimized array between a number of ultrasound transceivers and targets can improve the sensing capacity, point-spread function of the sensing array (their beam focusing ability), and imaging performance in point-like target detection. The theoretical results are promising and can open the way for more efficient metamaterial designs with the aim of enhancing ultrasound imaging with lower number of transceivers compared to the regular systems.

Acoustics↗

Structural and optical properties of nanoparticles formed by laser ablation of porous silicon in liquids: Perspectives in biophotonics

The paper discusses the possibility of manufacturing silicon nanoparticles, which are suitable for contrasting biological tissues imaged by optical coherence tomography, by femtosecond laser ablation of porous silicon in various liquids. The manufactured nanoparticles are characterised by average sizes of 87, 112, and 102 nm for cases of ablation in water, ethanol, and liquid nitrogen, respectively, as well as a relatively narrow size distribution, which provides additional advantages for subsequent delivery into biological tissues. Electrochemical etching, which results in the formation of layers of porous silicon, allows the yield of ablation products to be increased several-fold by lowering the ablation threshold, thereby increasing the light scattering efficiency of the prepared suspensions compared with the case of using crystalline silicon as targets. The possibility of obtaining high-contrast images of a biotissue phantom based on an agar gel with embedded nanoparticles is shown. The magnitude of the contrast depends on the liquid used for ablation and correlates with the values of the reduced scattering coefficient of the studied suspensions. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cancer cell membrane-coated rare earth doped nanoparticles for tumor surgery navigation in NIR-II imaging window

With the attractive characteristics of low toxicity, narrow emission spectra, long fluorescence lifetime, and no photobleaching, rare-earth doped nanoparticles (RENPs) have become promising imaging nanoplatforms in the second near-infrared window (NIR-II, 1000–1700 nm). Many studies have been devoted to different surface modification strategies of RENPs to achieve good NIR-II tumor imaging property. However, the tumor imaging efficiency of these approaches remains disappointing. Herein, two methods were pursued to modify RENPs with either polyethylene glycol (PEG) or cancer-cell-membrane to generate PEGylated-RENPs and cancer-cell-membrane camouflaged RENPs (CC-RENPs), respectively. Furthermore, this study demonstrated that cancer-cell-membrane coating of RENPs greatly improved tumor imaging performance in NIR-II window than PEG coating. Besides, CC-RENPs uptakes in liver and spleen significantly decreased. Importantly, CC-RENPs was found to be capable to aid us to pursue precise resection of the tumor. In conclusion, CC-RENPs are capable of targeting tumors and show high tumor NIR-II imaging quality. They are highly promising nanomaterials for future medical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Associated Particle Imaging of Neutron Inelastic Scatter: 3-D Reconstruction, Capabilities, and Challenges

Associated particle imaging (API) offers unique advantages for 3-D imaging of neutron inelastic scatter, including single-view tomographic imaging and data acquisition when access is limited to only one side of the interrogated object. However, widespread adoption of neutron inelastic scatter imaging has been impeded by several inherent challenges, most prominently spatial resolution, self-attenuation, and statistical noise. Here, in this work, the capabilities and challenges of neutron inelastic scatter imaging are investigated. Instead of focusing on a single imaging application, we identify imaging principles that hold for various neutron inelastic scatter imaging techniques. The primary challenges for 3-D imaging are characterized. The inherent spatial resolution in the time-of-flight (TOF) dimension is derived based on the known system timing resolution and scan geometry. Three reconstruction algorithms are described and demonstrated, including the introduction of modern iterative reconstruction incorporating a physics-based system model. Simulation is leveraged to demonstrate imaging capability with varying coincidence count levels and system timing resolution. An example of measured data with both back-scatter and forward-scatter detector positioning is presented. System design characteristics and their effects on image quality are identified. The imaging framework presented in this article has the potential to facilitate growth of 3-D neutron inelastic scatter API by identifying applications that are a good match for the technique and by targeting system development resources toward the requirements of a specific imaging task.

Associated particle imaging (API)↗

Microscopy imaging device with advanced imaging properties

Systems, methods and devices are implemented for microscope imaging solutions. One embodiment of the present disclosure is directed toward an epifluorescence microscope. The microscope includes an image capture circuit including an array of optical sensor. An optical arrangement is configured to direct excitation light of less than about 1 mW to a target object in a field of view of that is at least 0.5 mm 2 and to direct epi-fluorescence emission caused by the excitation light to the array of optical sensors. The optical arrangement and array of optical sensors are each sufficiently close to the target object to provide at least 2.5 μm resolution for an image of the field of view.

Ghosh, Kunal↗

Microscopy imaging device with advanced imaging properties

Systems, methods and devices are implemented for microscope imaging solutions. One embodiment of the present disclosure is directed toward an epifluorescence microscope. The microscope includes an image capture circuit including an array of optical sensor. An optical arrangement is configured to direct excitation light of less than about 1 mW to a target object in a field of view of that is at least 0.5 mm2 and to direct epi-fluorescence emission caused by the excitation light to the array of optical sensors. The optical arrangement and array of optical sensors are each sufficiently close to the target object to provide at least 2.5 μm resolution for an image of the field of view.

Ghosh, Kunal↗

Innovative approaches to neutron beam optimization: A case study of FP14 at LANSCE

This paper describes an experimental method to acquire high resolution energy- and spatially- resolved neutron beam spots using the time-gated neutron imaging system with Teledyne Pi-MAX4 camera. These experimental data offer a unique opportunity for benchmarking beam spot simulations. High-quality simulations depend significantly on a high-fidelity geometry model, which can be challenging for legacy facilities. We informed our MCNPX geometry model by latest metrology survey employing Leica laser tracker ATS600. It gave us a high fidelity description of our facility geometry. Such a robust integration of novel tools and methods yields a previously unattainable level of accuracy in both predicting and capturing neutron beam spots, marking a notable advancement over traditional methods reliant on static image plates. Here, to demonstrate the practical application of these tools, we are showing a non-uniform beam spot challenge at our Flight Path 14 (FP14) at the Los Alamos Neutron Science Center (LANSCE). Our precise MCNPX prediction of beam spot shifting as function of neutron energy was confirmed by experimental beam spot measured with extremely high level of detail. Results of this research demonstrate a significant leap in neutron beam optimization at LANSCE and set a new benchmark in beam spot characterization. The advanced methods presented here have potential for adoption at similar research facilities worldwide, aiming at substantial improvement in neutron beam delivery for experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimating cluster masses from SDSS multiband images with transfer learning

ABSTRACT The total masses of galaxy clusters characterize many aspects of astrophysics and the underlying cosmology. It is crucial to obtain reliable and accurate mass estimates for numerous galaxy clusters over a wide range of redshifts and mass scales. We present a transfer-learning approach to estimate cluster masses using the ugriz-band images in the SDSS Data Release 12. The target masses are derived from X-ray or SZ measurements that are only available for a small subset of the clusters. We designed a semisupervised deep learning model consisting of two convolutional neural networks. In the first network, a feature extractor is trained to classify the SDSS photometric bands. The second network takes the previously trained features as inputs to estimate their total masses. The training and testing processes in this work depend purely on real observational data. Our algorithm reaches a mean absolute error (MAE) of 0.232 dex on average and 0.214 dex for the best fold. The performance is comparable to that given by redMaPPer, 0.192 dex. We have further applied a joint integrated gradient and class activation mapping method to interpret such a two-step neural network. The performance of our algorithm is likely to improve as the size of training data set increases. This proof-of-concept experiment demonstrates the potential of deep learning in maximizing the scientific return of the current and future large cluster surveys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image Deconvolution and Point-spread Function Reconstruction with STARRED: A Wavelet-based Two-channel Method Optimized for Light-curve Extraction

We present starred, a point-spread function (PSF) reconstruction, two-channel deconvolution, and light-curve extraction method designed for high-precision photometric measurements in imaging time series. An improved resolution of the data is targeted rather than an infinite one, thereby minimizing deconvolution artifacts. In addition, starred performs a joint deconvolution of all available data, accounting for epoch-to-epoch variations of the PSF and decomposing the resulting deconvolved image into a point source and an extended source channel. The output is a high-signal-to-noise-ratio, high-resolution frame combining all data and the photometry of all point sources in the field of view as a function of time. Of note, starred also provides exquisite PSF models for each data frame. We showcase three applications of starred in the context of the imminent LSST survey and of JWST imaging: (i) the extraction of supernovae light curves and the scene representation of their host galaxy; (ii) the extraction of lensed quasar light curves for time-delay cosmography; and (iii) the measurement of the spectral energy distribution of globular clusters in the "Sparkler," a galaxy at redshift z = 1.378 strongly lensed by the galaxy cluster SMACS J0723.3-7327. starred is implemented in jax, leveraging automatic differentiation and graphics processing unit acceleration. This enables the rapid processing of large time-domain data sets, positioning the method as a powerful tool for extracting light curves from the multitude of lensed or unlensed variable and transient objects in the Rubin-LSST data, even when blended with intervening objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Time-resolved imaging of atoms and molecules in laser-produced uranium plasmas

Gas-phase oxidation of uranium (U), plume chemistry, and its impact on optical emission features of the uranium plasma are investigated. Plasmas were produced via nanosecond laser ablation of a natural uranium target in a chamber where uranium oxidation was controlled by varying the oxygen partial pressure within argon cover gas. Monochromatic imaging of uranium atoms and monoxide molecules was performed using narrowband optical filters, which clearly reveals the spatio-temporal evolution of these species in the plasma. Uranium oxides are found to be formed at the plasma edges, where lower temperatures favor molecular recombination. Segregation between the distribution of uranium atoms and monoxide species is observed at later times of plasma evolution, and is more apparent at lower oxygen partial pressures. At higher oxygen partial pressures, significant variation in plume morphology is noticed for UO species, which is attributed to higher rate of oxide (UxOy) formation at the plume edges. The monochromatic images of U atoms and molecules and corresponding spectral features at various oxygen partial pressures presented here provide a unique insight into gas-phase, high-temperature uranium oxidation, and its chemistry and have implications for a wide range of nuclear applications, from stand-off detection of radioisotopes to forensics and safeguards.

(140.3440) Laser-induced breakdown, (280.4788) Opt↗

Origin, parameters, and underlying deformation mechanisms of propagating deformation bands in irradiated 316L stainless steel

Lüders-type propagating deformation bands were observed in specimens of irradiated 316L stainless steel samples removed from Spallation Neutron Source target vessels after service. Mechanical testing with digital image correlation (DIC) and in-situ tensile testing with scanning electron microscopy electron backscatter diffraction showed that the observed Lüders-type behavior was not related to the known transformation-induced plasticity or twinning-induced plasticity behavior. Instead, the phenomenon occurs at small local strain values before a significant amount of martensite or deformation twins appear in the microstructure. Microstructural analysis and in-situ mechanical test results suggest Lüders-type band formation and propagation were related to the appearance and evolution of defect-free channels—analogous to slip bands. A modified Swift equation with a Ludwigson-like component was offered to rationalize the phenomenon and model the strain-softening processes at small strain values. Finally, the results indicate complex microstructural processes and deformation mechanisms were active at small strain values and underline the benefits of advanced mechanical test approaches such as DIC.

36 MATERIALS SCIENCE↗

Magneto mitochondrial dysfunction mediated cancer cell death using intracellular magnetic nano-transducers

Mitochondria are crucial regulators of the intrinsic pathway of cancer cell death. The high sensitivity of cancer cells to mitochondrial dysfunction offers opportunities for emerging targets in cancer therapy. Herein, magnetic nano-transducers, which convert external magnetic fields into physical stress, are designed to induce mitochondrial dysfunction to remotely kill cancer cells. Spindle-shaped iron oxide nanoparticles were synthesized to maximize cellular internalization and magnetic transduction. The magneto-mechanical transduction of nano-transducers in mitochondria enhances cancer cell apoptosis by promoting a mitochondrial quality control mechanism, referred to as mitophagy. Furthermore, in the liver cancer animal model, nano-transducers are infused into the local liver tumor via the hepatic artery. After treatment with a magnetic field, in vivo mitophagy-mediated cancer cell death was also confirmed by mitophagy markers, mitochondrial DNA damage assay, and TUNEL staining of tissues. This study is expected to contribute to the development of nanoparticle-mediated mitochondria-targeting cancer therapy and biological tools, such as magneto-genetics.

60 APPLIED LIFE SCIENCES↗

Design, performance, and field operation of twisting heliostats for 3,000-sun concentration and high temperature

The idea is to combine the solar energy reflected from a field of many heliostats to obtain a single focus of high concentration and high power. We exploit a new type of “twisting” heliostat” in which as the mount is moved to track the sun through the day, the reflector shape is twisted to maintain a focused image of the sun’s disc on the target, through the day over a wide range of angles of incidence. By combining the light reflected by many twisting heliostats into a single focus, we are not only able to accomplish but also maintain very high concentration and temperature through the day, with higher efficiency than has previously been possible with conventional heliostats having a fixed shape. A circular field of twisting heliostats is used to power a single intense focus atop a central tower. The light from all the heliostats is relayed to an upward facing receiver at the focus via a central Cassegrain secondary reflector located above the receiver. In a specific design targeting 1 MW of power, a 100 m diameter field arrays 431 twisting heliostats, each with a 7 m2 reflector. The secondary reflector ,7.2 m in diameter, is located 24 m above the heliostat field, bringing sunlight with annual average power of 1 MW to a circular focus 0.8 m in diameter, at a concentration averaging 3,000 suns.

14 SOLAR ENERGY↗