Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Powering the Blue Economy Foundational Research & Development Topics Reliability for Marine Energy Power Systems

Ocean observing platforms are deployed across the world’s oceans to collect meteorological and oceanographic data. Current technology makes use of solar panels and battery banks to provide power to these platforms, which can be challenging at high latitudes due to lack of solar insolation and cold temperatures. Marine renewable energy (MRE) generation offers a potential improvement in consistent power generation throughout the year for this use on ocean observation buoys. This report analyzes existing reliability of high latitude coastal weather buoys and tsunami detection buoys to determine performance standards that MRE generation sources must meet to become viable power sources for these remote systems. Using measurements recorded from the U.S. National Data Buoy Center’s coastal weather buoys and tsunami detection buoys, the analysis calculated the historic data availability – or the percentage of time a measurement is recorded – to evaluate the reliability of ocean observation buoys. The results show that coastal weather buoys operate at 74% data availability and the tsunami detection systems operate at an average 72% data availability. The results describe the total reliability of the system, including many different types of failures not associated with the power system such as mooring failures or equipment failures caused by extreme weather. Power system outages may only account for a small portion of the system failures. Reliability is an important design criterion for the power system of ocean observation platforms. Future power systems that would be designed for these buoys, such as an MRE generator, need to have a minimum reliability of 72% and 74% to meet the overall performance of the weather buoys and tsunami buoys, respectively. However, power system reliability likely needs to be much higher than overall system reliability, so that power system outages do not negatively impact the overall performance of the buoy.

42 ENGINEERING↗

Reliability Analysis of Power Grids Considering Component Failures of Variable Energy Resources

This paper proposes an improved model for the reliability assessment of power systems considering component failures of variable energy resources (VER). The inherent intermittency of VER such as solar photovoltaic (PV) and wind farms, along with their susceptibility to component failures, present significant challenges to reliable system operation. These issues, combined with power grid operation and network constraints, complicate the reliable operation of VER-integrated power systems. Here, to address these concerns, this paper introduces a reliability assessment framework that considers VER input variability, its impact on component availability, and their resulting impact on overall system reliability. Stochastic models based on discrete Markov processes are developed to incorporate variable irradiance, wind speeds, and their effects on PV and wind component failure rates. A next-event and state transition-based approach is then developed to integrate the stochastic models into a mixed-timing sequential Monte Carlo simulation framework for composite reliability assessment. Case studies on the RTS-GMLC system demonstrate the effectiveness of the proposed model in evaluating the reliability of VER-integrated systems.

Pandit, Dilip [Sandia National Laboratories (SNL-N↗

Ultra-Fast Resonant DC Breaker

This project’s focus was to create an ultra-fast resonant hybrid dc circuit breaker for medium voltage electric systems. Medium voltage DC systems offer higher efficiency, additional resiliency, more controllability, and greater flexibility over comparable AC systems. Although technically, medium voltage DC systems are more attractive than their AC counterparts, no solution exists for the protection of medium voltage DC systems, and thus one cannot build a reliable MVDC system. This research will fill the technology gap, providing a MVDC protection solution, allowing mass adoption and proliferation of MVDC systems. MVDC systems will allow greater integration of renewable energy sources, higher efficiency of transmission and distribution, reduced losses in transmission lines, reduce carbon emissions, and higher electric power reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Supportive Loads - A New Approach to Increasing Renewable Energy in Power Systems

This paper demonstrates the potential of inverter-based loads to support grid reliability during power system transients thereby enabling reliable integration of renewable energy in power systems. Such loads are referred to in this paper as grid-supportive loads (GSLs). A new GSL model is developed that simulates the transient response capabilities that can be programmed in electronic loads. The model’s design enables it to be easily integrated in widely used commercial power system transient analysis software. Theoretical expressions are derived that explain the workings of the GSL model. The performance, numerical stability, and impact of the GSL model is validated on 9-bus and 2000-bus synthetic power system models using generator tripping and bus fault disturbances. Results on the 2000 bus system show that in the absence of frequency support from wind/solar generation resources, just 20% of loads with grid-supportive capabilities can improve frequency response by up to 2000 MW/0.1 Hz and reduce deviation in frequency at nadir by up to 60% compared to the situation when GSLs are absent. Power system reliability also improves under fault events. Here, it is further shown that GSLs can aid in integrating more renewable generation without degrading the overall transient response of the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Indoor Occupant Counting by RF Backscattering

Building HVAC (heating, ventilation and air conditioning) consumes approximately 13% of all energy consumption in USA. Motion detectors, cameras and user programmable thermostats have been shown to be ineffective for HVAC controls to save energy, mostly due to the user concerns of comfort, reliability and privacy. A new HVAC control system based on real-time occupant counting that is fully automated, highly accurate, economically sensible and preserving privacy and aesthetics can thus bring forth a disruptive impact to this large energy sector. Our indoor occupant monitoring technology is based on the radio-frequency identification system (RFID), deployed in the room, not on the occupants. One reader with four antennas can be deployed on the ceiling or behind the ceiling panels for every thousand square feet in home, office and assisted living, with or without room partitions. The sticker-like passive tag, 10 cents each and maintenance-free, are profusely hidden on the wall or inside the furniture at arbitrary position, preserving privacy and aesthetics. The large number of tags can realize diverse observation points to accommodate arbitrary room layouts, which is impractical by other active units of camera, infrared, radar or lidar. With 20 tags, the system can reliably detect the number of occupants. For 100 tags, occupant posture and location can be known. The technology has been verified in the research labs and test buildings with very high accuracy. When the real-time occupant number can be accurately known without assuming devices on occupants or occupant motion, the building HVAC system can be automated to achieve building energy saving without sacrificing occupant comfort. According to our limited testing in a few types of building models and the simplified cost calculation, the RFID system has low overall cost in production, deployment, operation and maintenance. The signal processing algorithm based on machine learning requires very small number of training cases as most learning is transferrable for various layouts, and very low computational needs during operation, according to our testing in four different room sizes and layouts. In our preliminary estimate from HVAC saving alone, the RFID system can potentially pay for itself within 1.5 years, in addition to the other enhancement in building automation systems (BAS). Our commercialization strategy and business pitch deck focus on venturing this Cornell occupant monitoring technology into BAS and energy management markets. We have identified three broad BAS market segments of senior living, residential buildings, and office buildings. We have put together the minimum viable product characteristics for these identified segments, including analyses on total cost and competing technologies, as well as the fit and technical gaps for these market segments. We intend to bring the technology to market by licensing or partnering with existing BAS vendors. A list of potential collaborators and licensing partner candidates was assembled for different aspects of integrating our technology into a potential product that can be used with BAS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Impact of Managed EV Charging for Reliable Operation of Bulk Power Systems with High Non-Dispatchable Generation

The growth of electric vehicles (EVs) and variable-generation (VG) sources introduces new challenges for power-system operations. This study introduces a modeling framework and evaluates five EV charging strategies under projected 2040 grid conditions in the Evergy service territory with high non-dispatchable generation. Using realistic EV behavior and generation models, their impacts on system peak demand, ramp rate, and reserve capacity are evaluated. Results show that only the peak-avoidance strategy effectively reduces system peak demand, while decentralized strategies-particularly cost based dynamic charging-can exacerbate peaks due to synchronized user behavior. However, ramp-rate minimization strategy significantly reduce the stress on dispatchable generation achieving the lowest maximum absolute ramp rate (MARR) (56.81 MW) and lowest reserve requirement (2.39 GW). In contrast, unmanaged and TOU random strategies increase the stress on dispatchable generation sources with increased MARR and reserve requirements. These findings highlight the importance of coordinated, system-aware managed charging strategies to ensure reliable and affordable grid operation in the presence of EVs and VG sources.

14 - SOLAR ENERGY↗

Rapid Characterization and Statistical Analysis of High-Volume Field-Harvested Photovoltaic Connectors

Photovoltaic (PV) installations heavily depend on connectors for efficient module and string interconnections without requiring skilled labor. Yet this seemingly innocuous component of PV systems is a leading cause of module failures, multiple high-profile fires, and lawsuits in the PV industry. This work aims to answer critical questions regarding why connectors fail and the contributing factors to their failure. The study involves collecting and analyzing more than 17,000 field-harvested connectors from various solar installations across the United States. The vast dataset, which includes connector metadata, visual inspections, and resistance measurements, provides unprecedented insight into the state of health of PV connectors across the US, including the geographic locations, connector types, and installation practices most prone to failures. The work presented here describes a novel rapid characterization method for processing large numbers of connectors and is supported by parallel forensic analysis to discern the root causes of failures as well as a levelized cost of lifetime model to determine the economic ramifications of connector failure. Ultimately, the findings may inform PV developers about the best practices to extend connector longevity and lead to more resilient and reliable PV systems.

connectors↗

System Health and Status Reporting is Used to Improve Infrastructure Systems at the Hanford Site - 20449

Reliable physical infrastructure systems are vital to completing the clean-up mission and the start-up and commissioning of new nuclear waste processing facilities at the Hanford Site. Key infrastructure systems at Hanford include water, sewer, and electrical utilities, roads, telecommunications/network systems, and fire systems. All of the infrastructure systems are non-nuclear, General Service systems that are being maintained under formal engineering configuration control and none are specifically credited in any documented safety analysis (DSA). Starting in calendar year 2017, the Hanford Site's infrastructure and services contractor started producing system health and status reports for a total of 15 critical infrastructure systems as means to get a better understanding of each system's health and how it could be improved to ensure better and more reliable service delivery. As the reporting, tracking, and use of the metrics has matured, the number of systems for which reports are being developed has been expanded to a total of 23. Each of the critical infrastructure systems are assigned primary and alternate design authorities that complete qualifications on each assigned system. The design authorities actively manage and maintain configuration control on each of their systems and track metrics associated with availability, maintenance (corrective and preventive), and configuration of the technical baseline. The metrics are based on the principles established in Chapter V of DOE O 420.1C, Facility Safety, [1] and have been tailored as appropriate to each of the key infrastructure systems. An overall assessment of system health is performed and documented on a routine basis (e.g., quarterly). Included in this documentation is a quantitative score for each of the metrics (i.e., availability, maintenance, configuration management) along with results of system walk-downs, description of any permanent design modifications, identification of new or emerging issues and vulnerabilities affecting the system, and an assessment by the design authority of actions necessary to improve the system health score. The overall status scores are calculated using a formula and based on a pre-determined grading scale, a color is assigned for simple presentation. The information gained from developing the reports is being used to (1) assist with making timely and better informed decisions through the use of solid technical bases that are increasing the overall reliability and capabilities of the Site's infrastructure systems as new expense and capital projects in the Reliability Projects Investment Portfolio (RPIP) are prioritized and executed; (2) feed the risk management program, and (3) integrate the technical content of Master Plans that describe the Site's needs for the system and the system's capabilities to meet those future needs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

System Study: Emergency Power System 1998–2018

This report presents an unreliability evaluation of the emergency power system (EPS) at 104 U.S. commercial nuclear power plants. Demand, run hours, and failure data from 1998 through 2018 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the EPS results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Performance SOFCs with a Superior Stability for Reliable and Durable Power Systems

Next generation of fuel cells, electrolyzers, and batteries requires higher power, faster kinetics, and larger energy density, which necessitate the use of compositionally complex oxides to achieve multifunctionalities and activity. These compositionally complex oxides may change their phases and structures during an electrochemical process – a so-called “electrochemically driven phase transformation”. The origin for such a phase change has remained obscure. More importantly, there is a need to develop high performance solid oxide fuel cells with an enhanced stability. In this work, the La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3 (LSCF) cathode surface is modified by infiltration of Pr 6 O 11 and the power density at 0.8V and 750 °C is improved by 21%. In addition, by replacing the traditional barrier layer Gd 0.2 Ce 0.8 O 1.9 with mixed conducting Pr 0.1 Gd 0.1 Ce 0.8 O 1.9 , the power density increases by 38%. The different mechanism of promotions was investigated by electrochemical impedance spectroscopy. The ohmic resistance is dramatically reduced by applying the PGCO interlayer, and the distribution of relaxation time was used to analyze the mechanism for which the polarization resistance was decreased attributing to the mixed conduction nature in PrO x . An increase of power density at 0.8 V of 0.358 W/cm 2 (71%) is achieved with the implementation of both surface modification and buffer layer engineering. An experimental study and a theoretical analysis were then carried out on phase evolution in praseodymium nickelates. Nickelate-based electrodes show up to 60× greater phase transformation during operation when compared to thermally annealed ones. Theoretical analysis suggests that the presence of a reduced oxygen partial pressure at the interface between the oxygen electrode and the electrolyte is the origin for the phase change in an oxygen electrode. Guided by the theory, an addition of the electronic conduction in the interface layer leads to the significant suppression of phase change, while improving cell performance and performance stability. When an oxygen electrode is under polarization, the oxygen partial pressure at the interface between the oxygen electrode and the electrolyte is lower than that of incoming oxidant. Under a high polarization, the environment at the aforementioned interface may lead to phase transformation of the oxygen electrode. The local oxygen partial pressure is determined by the transport properties at the interfaces. An addition of the electronic conduction in the interface layer, for instance using (Pr,Gd)-doped ceria to replace Gd-doped ceria, results in improved cell performance and performance stability, while the phase transformation is significantly suppressed. This work provides a fundamental understanding of the origin for phase transformation in oxygen electrodes during operation and use this knowledge to develop a high-performance electrode that exhibits improved performance stability.

30 DIRECT ENERGY CONVERSION↗

Mississippi's Strategic Resilience: A multi-systems approach to secure, reliable, and adaptable electric grid infrastructure

Mississippi’s electric grid resilience challenges are linked to an intersection of complex socioeconomic, ecological, technological, historical, and political challenges, exacerbated by increasing severe weather like flooding and tornado events. The state’s legacy of underinvestment in critical energy infrastructure, particularly in rural areas and vulnerable floodplains, have stressed an aging grid, creating long-lasting disruptions in electric service during weather-related outages. Effective emergency management and preparedness is further hampered by a lack of coordination across local, county, and regional scales. Using the TASTI-GRID platform and partnership with Oak Ridge National Laboratory (ORNL), Mississippi is developing a comprehensive regional resilience strategy to overcome energy security and reliability challenges, mitigating the impacts of natural hazards, and positioning Mississippi as a resilient and premier destination for residents, businesses, and economic development.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hazard Analysis to Support Fusion Systems Safety Assessments

Reliability, safety, and performance are vital aspects of any nuclear operation. Fusion technology continues to grow in public, private, and research interest, and coupled with rapidly growing energy needs, fusion technology research is poised for fast progress. The development of a Fusion Nuclear Science Facility (FNSF) is seen as stepping stone for demonstrating long-cycle fusion. Naturally, such operation requires systems that are available, reliable, and safe. This work provides a novel demonstration of systems theory coupled with traditional hazard analysis to provide insights into the risk priority of components and systems found within the FNSF. The results of this work are a set of identified hazards that should be considered for the risk-informed design and development of the FNSF.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensitivity and Importance Measure Analyses for Various Design Architectures for High Safety-Significant Safety-Related Digital Instrumentation and Control Systems of Nuclear Power Plants

A transition from analog instrumentation and control (I&C) technologies to digital I&C technologies is taking place for license renewals of existing nuclear power plants and for operating licenses of new advanced reactors. This transition necessitates research on risk and economic assessments of digital I&C technologies to ensure the long-term safety and reliability of vital systems, reduce uncertainty in licensing costs in addition to timeline, support integration of digital I&C systems in the plant, and find the most efficient technology upgrades. Adding redundancy within systems or components is a common means of improving design safety; however, it can also make designs more prone to common-cause failures (CCFs). Introducing diversity into redundant systems or components is a way to mitigate and possibly eliminate CCFs, but it also increases plant complexity and may be costly. The balance between redundancy and diversity remains a challenge for digital I&C systems. This study performs sensitivity and importance analyses for four design architectures of two digital I&C systems—the reactor-trip system and the engineered safety features actuation system. For each system, two architectures are examined, including a redundant, non-diverse configuration and a redundant, diverse configuration. The sensitivity analysis will provide insights on the impact of introducing diversity to system reliability. The importance results will help identify risk-significant and risk-sensitive components and failure modes, which may be good candidates for future design improvement.

99 GENERAL AND MISCELLANEOUS↗