Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Absolute x-ray dosimetry on a synchrotron medical beam line with a graphite calorimeter

Purpose: The absolute dose rate of the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter. The calorimetry results were compared to measurements from the existing free-air chamber, to provide a robust determination of the absolute dose in the synchrotron beam and provide confidence in the first implementation of a graphite calorimeter on a synchrotron medical beam line. Methods: The graphite calorimeter has a core which rises in temperature when irradiated by the beam. A collimated x-ray beam from the synchrotron with well-defined edges was used to partially irradiate the core. Two filtration sets were used, one corresponding to an average beam energy of about 80 keV, with dose rate about 50 Gy/s, and the second filtration set corresponding to average beam energy of 90 keV, with dose rate about 20 Gy/s. The temperature rise from this beam was measured by a calibrated thermistor embedded in the core which was then converted to absorbed dose to graphite by multiplying the rise in temperature by the specific heat capacity for graphite and the ratio of cross-sectional areas of the core and beam. Conversion of the measured absorbed dose to graphite to absorbed dose to water was achieved using Monte Carlo calculations with the EGSnrc code. The air kerma measurements from the free-air chamber were converted to absorbed dose to water using the AAPM TG-61 protocol. Results: Absolute measurements of the IMBL dose rate were made using the graphite calorimeter and compared to measurements with the free-air chamber. The measurements were at three different depths in graphite and two different filtrations. The calorimetry measurements at depths in graphite show agreement within 1% with free-air chamber measurements, when converted to absorbed dose to water. The calorimetry at the surface and free-air chamber results show agreement of order 3% when converted to absorbed dose to water. The combined standard uncertainty is 3.9%. Conclusions: The good agreement of the graphite calorimeter and free-air chamber results indicates that both devices are performing as expected. Further investigations at higher dose rates than 50 Gy/s are planned. At higher dose rates, recombination effects for the free-air chamber are much higher and expected to lead to much larger uncertainties. Since the graphite calorimeter does not have problems associated with dose rate, it is an appropriate primary standard detector for the synchrotron IMBL x rays and is the more accurate dosimeter for the higher dose rates expected in radiotherapy applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optoelectronic Picosecond Detection of Synchrotron X-rays

The goal of this research program was to develop a detector that would measure x-ray time profiles with picosecond resolution. This was specifically aimed for use at x-ray synchrotrons, where x-ray pulse profiles have Gaussian time spreads of 50-100 ps (FWHM), so the successful development of such a detector with picosecond resolution would permit x-ray synchrotron studies to break through the pulse width barrier. That is, synchrotron time-resolved studies are currently limited to pump-probe studies that cannot reveal dynamics faster than ~50 ps, whereas the proposed detector would push this into the physically important 1 ps domain. The results of this research effort, described in detail below, are twofold: 1) the original plan to rely on converting electronic signals from a semiconductor sensor into an optical signal proved to be insufficient for generating signals with the necessary time resolution and sensitivity to be widely applicable; and 2) an all-optical method was discovered whereby the x-rays are directly absorbed in an optoelectronic material, lithium tantalate, which can then be probed by laser pulses with the desired picosecond sensitivity for detection of synchrotron x-rays. This research program has also produced new fundamental understanding of the interaction of x-rays and optical lasers in materials that has now created a viable path for true picosecond detection of synchrotron x-rays.

36 MATERIALS SCIENCE↗

SPECTRUM AND ANISOTROPY OF TURBULENCE FROM MULTI-FREQUENCY MEASUREMENT OF SYNCHROTRON POLARIZATION

We consider turbulent synchrotron-emitting media that also exhibit Faraday rotation and provide a statistical description of synchrotron polarization fluctuations. In particular, we consider these fluctuations as a function of the spatial separation of the direction of the measurements and as a function of wavelength for the same line of sight. On the basis of our general analytical approach, we introduce several measures that can be used to obtain the spectral slopes and correlation scales of both the underlying magnetic turbulence responsible for emission and the spectrum of the Faraday rotation fluctuations. We show the synergetic nature of these measures and discuss how the study can be performed using sparsely sampled interferometric data. We also discuss how additional characteristics of turbulence can be obtained, including the turbulence anisotropy and the three-dimensional direction of the mean magnetic field. In addition, we consider the cases when the synchrotron emission and Faraday rotation regions are spatially separated. Appealing to our earlier study, we explain that our new results are applicable to a wide range of spectral indexes of relativistic electrons responsible for synchrotron emission. We expect wide application of our techniques, both with existing synchrotron data sets and with big forthcoming data sets from LOFAR and SKA.

79 ASTRONOMY AND ASTROPHYSICS↗

Efficiency of Synchrotron Radiation from Rotation-powered Pulsars

Synchrotron radiation is widely considered to be the origin of the pulsed non-thermal emissions from rotation-powered pulsars in optical and X-ray bands. In this paper, we study the synchrotron radiation emitted by the created electron and positron pairs in the pulsar magnetosphere to constrain the energy conversion efficiency from the Poynting flux to the particle energy flux. We model two pair creation processes, two-photon collision, which efficiently works in young γ -ray pulsars (≲10{sup 6} year), and magnetic pair creation, which is the dominant process to supply pairs in old pulsars (≳10{sup 6} year). Using the analytical model, we derive the maximum synchrotron luminosity as a function of the energy conversion efficiency. From the comparison with observations, we find that the energy conversion efficiency to the accelerated particles should be an order of unity in the magnetosphere, even though we make a number of the optimistic assumptions to enlarge the synchrotron luminosity. In order to explain the luminosity of the non-thermal X-ray/optical emission from pulsars with low spin-down luminosity L {sub sd} ≲ 10{sup 34} erg s{sup −1}, non-dipole magnetic field components should be dominant at the emission region. For the γ -ray pulsars with L {sub sd} ≲ 10{sup 35} erg s{sup −1}, observed γ -ray to X-ray and optical flux ratios are much higher than the flux ratio between curvature and the synchrotron radiations. We discuss some possibilities such as the coexistence of multiple accelerators in the magnetosphere as suggested from the recent numerical simulation results. The obtained maximum luminosity would be useful to select observational targets in X-ray and optical bands.

79 ASTRONOMY AND ASTROPHYSICS↗

Synchrotron Spectrum of Fast Cooling Electrons in GRBs

We discuss the synchrotron emission of fast cooling electrons in shocks. The fast cooling electrons behind the shocks can generate a position-dependent inhomogeneous electron distribution if they do not have enough time to mix homogeneously. This can lead to a very different synchrotron spectrum in low-frequency bands from that in the homogeneous case, due to the synchrotron absorption. In this paper, we calculate the synchrotron spectrum in the inhomogeneous case in a gamma-ray burst (GRB). Both the forward shock and the reverse shock are considered. We find that for the reverse shock dominated case, we would expect a “reverse shock bump” in the low-frequency spectrum. The spectral bump is due to the combination of synchrotron absorption in both the forward and reverse shock regions. In the low frequencies the forward shock spectrum has two unconventional segments, with spectral slopes of ≲1 and 11/8. The slope of 11/8 has been found by some authors, while the slope of ≲1 is new and due to the approximately constant electron temperature in the optically thick region. In the future, simultaneous observations in multiple bands (especially in the low-frequency bands) in the GRB early afterglow or prompt emission phases will possibly reveal these spectral characteristics and enable us to identify the reverse shock component and distinguish between the forward and reverse shock emissions. This also may be a method with which to diagnose the electron distribution status (homogeneous or inhomogeneous) after fast cooling in the relativistic shock region.

79 ASTRONOMY AND ASTROPHYSICS↗

Synchrotron Self-Compton Emission from the Crab and Other Pulsars

Results of a simulation of synchrotron-self Compton (SSC) emission from a rotation-powered pulsar are presented. The radiating particles are assumed to be both accelerated primary electrons and a spectrum of electron-positron pairs produced in cascades near the polar cap. They follow trajectories in a slot gap using 3D force-free magnetic field geometry, gaining pitch angles through resonant cyclotron absorption of radio photons, radiating and scattering synchrotron emission at high altitudes out to and beyond the light cylinder. Full angular dependence of the synchrotron photon density is simulated in the scattering and all processes are treated in the inertial observer frame. Spectra for the Crab and Vela pulsars as well as two energetic millisecond pulsars, B1821-24 and B1937+21 are simulated using this model. The simulation of the Crab pulsar radiation can reproduce both the flux level and the shape of the observed optical to hard X-ray emission assuming a pair multiplicity of M+ = 3x10(exp 5), as well as the very-high- energy emission above 50 GeV detected by MAGIC and VERITAS, with both the synchrotron and SSC components reflecting the shape of the pair spectrum. Simulations of Vela, B1821-24 and B1937+21, for M+ up to 10(exp 5), do not produce pair SSC emission that is detectable by current telescopes, indicating that only Crab-like pulsars produce significant SSC components. The pair synchrotron emission matches the observed X-ray spectrum of the millisecond pulsars and the predicted peak of this emission at 1-10 MeV would be detectable with planned Compton telescopes.

Self-Compton↗

High-Resolution Infrared Spectroscopy with Synchrotron Sources

Most applications of synchrotron radiation lie in the ultraviolet and X-ray region, but it also serves as a valuable continuum source of infrared (IR) light which is much brighter (i.e. more highly directional) than that from normal thermal sources. The synchrotron brightness advantage was originally exploited for high spatial resolution spectroscopy of condensed-phase samples. But it is also valuable for high spectral resolution of gas-phase samples, particularly in the difficult far-IR (terahertz) range (1/{lambda} {approx} 10-1000 cm{sup -1}). Essentially, the synchrotron replaces the usual thermal source in a Fourier transform IR spectrometer, giving a increase of up to two (or even more) orders of magnitude in signal at very high-resolution. Following up on pioneering work in Sweden (MAX-lab) and France (LURE), a number of new facilities have recently been constructed for high-resolution gas-phase IR spectroscopy. In the present paper, this new field is reviewed. The advantages and difficulties associated with synchrotron IR spectroscopy are outlined, current and new facilities are described, and past, present, and future spectroscopic results are summarized.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synchrotron Radiation Therapy from a Medical Physics point of view

Synchrotron radiation (SR) therapy is a promising alternative to treat brain tumors, whose management is limited due to the high morbidity of the surrounding healthy tissues. Several approaches are being explored by using SR at the European Synchrotron Radiation Facility (ESRF), where three techniques are under development Synchrotron Stereotactic Radiation Therapy (SSRT), Microbeam Radiation Therapy (MRT) and Minibeam Radiation Therapy (MBRT).The sucess of the preclinical studies on SSRT and MRT has paved the way to clinical trials currently in preparation at the ESRF. With this aim, different dosimetric aspects from both theoretical and experimental points of view have been assessed. In particular, the definition of safe irradiation protocols, the beam energy providing the best balance between tumor treatment and healthy tissue sparing in MRT and MBRT, the special dosimetric considerations for small field dosimetry, etc will be described. In addition, for the clinical trials, the definition of appropiate dosimetry protocols for patients according to the well established European Medical Physics recommendations will be discussed. Finally, the state of the art of the MBRT technical developments at the ESRF will be presented. In 2006 A. Dilmanian and collaborators proposed the use of thicker microbeams (0.36-0.68 mm). This new type of radiotherapy is the most recently implemented technique at the ESRF and it has been called MBRT. The main advantage of MBRT with respect to MRT is that it does not require high dose rates. Therefore it can be more easily applied and extended outside synchrotron sources in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetry protocol for the forthcoming clinical trials in synchrotron stereotactic radiation therapy (SSRT)

Purpose: An adequate dosimetry protocol for synchrotron radiation and the specific features of the ID17 Biomedical Beamline at the European Synchrotron Radiation Facility are essential for the preparation of the forthcoming clinical trials in the synchrotron stereotactic radiation therapy (SSRT). The main aim of this work is the definition of a suitable protocol based on standards of dose absorbed to water. It must allow measuring the absolute dose with an uncertainty within the recommended limits for patient treatment of 2%-5%. Methods: Absolute dosimetry is performed with a thimble ionization chamber (PTW semiflex 31002) whose center is positioned at 2 g cm{sup -2} equivalent depth in water. Since the available synchrotron beam at the ESRF Biomedical Beamline has a maximum height of 3 mm, a scanning method was employed to mimic a uniform exposition of the ionization chamber. The scanning method has been shown to be equivalent to a broad beam irradiation. Different correction factors have been assessed by using Monte Carlo simulations. Results: The absolute dose absorbed to water at 80 keV was measured in reference conditions with a 2% global uncertainty, within the recommended limits. The dose rate was determined to be in the range between 14 and 18 Gy/min, that is to say, a factor two to three times higher than the 6 Gy/min achievable in RapidArc or VMAT machines. The dose absorbed to water was also measured in a RW3 solid water phantom. This phantom is suitable for quality assurance purposes since less than 2% average difference with respect to the water phantom measurements was found. In addition, output factors were assessed for different field sizes. Conclusions: A dosimetry protocol adequate for the specific features of the SSRT technique has been developed. This protocol allows measuring the absolute dose absorbed to water with an accuracy of 2%. It is therefore satisfactory for patient treatment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a containment apparatus for synchrotron XAS measurements of radioactive fluid samples under high temperatures and pressures

The simple working principles and versatility of the hydrothermal diamond-anvil cell (HDAC) make it signifcantly useful for synchrotron x-ray studies of aqueous and fluid samples at high pressure-temperature (P-T) conditions. Yet, safety concerns need to be overcome in order to use the HDAC for synchrotron studies of aqueous radioactive samples at high temperatures and pressures. For accomplishment of such hydrothermal experiments of radioactive materials at synchrotron beamlines, the samples are required to be enclosed in a containment system employing three independent layers of airtight sealing at some synchrotron facilities while enabling access to the sample using several experimental probes, including incoming and outgoing x-rays. In this article, we report the design and implementation of a complete radiological safety enclosure system for an HDAC specialized for high P-T x-ray absorption spectroscopy (XAS) measurements of aqueous solutions containing the actinides at synchrotron beamlines. The enclosure system was successfully tested for XAS experiments using the HDAC with aqueous samples containing depleted uranium at temperatures ranging from 25 to 500 °C and pressures ranging from vapor pressure to 350 MPa.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SYNCHROTRON-LOSS SPECTRAL BREAKS IN PULSAR-WIND NEBULAE AND EXTRAGALACTIC JETS

Flows of synchrotron-emitting material can be found in several astrophysical contexts, including extragalactic jets and pulsar-wind nebulae (PWNe). For X-ray synchrotron emission, flow times are often longer than electron radiative lifetimes, so the effective source size at a given X-ray energy is the distance electrons radiating at that energy can convect before they burn off. Since synchrotron losses vary strongly with electron energy, the source size drops with increasing X-ray energy, resulting in a steepening of the synchrotron spectrum. For homogeneous sources, this burnoff produces the well known result of a steepening by 0.5 in the source's integrated spectral index. However, for inhomogeneous sources, different amounts of steepening are possible. I exhibit a simple phenomenological picture of an outflow of relativistic electrons with bulk nonrelativistic flow speed, with transverse flow-tube radius, magnetic field strength, matter density, and flow velocity all varying as different powers of distance from the injection point. For such a picture, I calculate the value of the spectral index above the break as a function of the power-law indices, and show the possible range of steepenings. I show that these simple calculations are confirmed by full integrations of source luminosity, which also include the spectral 'bump' below the break from the accumulation of electrons formerly at higher energies. In many cases, extragalactic jets show X-ray synchrotron emission steeper by more than 0.5 than the radio emission; the same phenomenon is exhibited by many PWNe. It is possible that source inhomogeneities are responsible in at least some cases, so that the amount of spectral steepening becomes a diagnostic for source dynamical or geometrical properties.

79 ASTRONOMY AND ASTROPHYSICS↗

SYNCHROTRON EMISSION FROM ELLIPTICAL GALAXIES CONSEQUENT TO ACTIVE GALACTIC NUCLEUS OUTBURSTS

Both radiative and mechanical feedback from active galactic nuclei have been found to be important for the evolution of elliptical galaxies. We compute how a shock may be driven from a central black hole into the gaseous envelope of an elliptical galaxy by such feedback (in the form of nuclear winds) using high resolution one-dimensional hydrodynamic simulations. We calculate the synchrotron emission from the electron cosmic rays accelerated by the shocks (not the jets) in the central part of elliptical galaxies, and we also study the synchrotron spectrum's evolution using the standard diffusive shock acceleration mechanism, which is routinely applied to supernova remnants. We find quantitative consistency between the synchrotron radio emission produced via this mechanism with extant observations of elliptical galaxies which are undergoing outbursts. Additionally, we also find that synchrotron optical and X-ray emission can co-exist inside elliptical galaxies during a specific evolutionary phase subsequent to central outbursts. In fact, our calculations predict a peak synchrotron luminosity of {approx}1.3 x 10{sup 6} L{sub sun} at the frequency 5 GHz (radio band), of {approx}1.1 x 10{sup 6} L{sub sun} at 4.3 x 10{sup 14} Hz (corresponding to the absolute magnitude -10.4 in R band), and of {approx}1.5 x 10{sup 7} L{sub sun} at 2.4 x 10{sup 17} Hz (soft X-ray, 0.5-2.0 keV band).

79 ASTRONOMY AND ASTROPHYSICS↗

Averaged invariants in storage rings with synchrotron motion

In an ideal accelerator, the single-particle dynamics can be decoupled into transverse motion—the betatron oscillations— and longitudinal motion—the synchrotron oscillations. Chromatic and dispersive effects introduce a coupling between these dynamics, the so-called synchro-betatron coupling. We present an analysis of the fully coupled dynamics over a single synchrotron oscillation that leads to an averaged invariant with synchro-betatron coupling in a generic lattice. Here, we apply this analysis to two problems: first, a toy lattice where the computations are analytically tractable, then a design for a rapid cycling synchrotron built using the integrable optics described by Danilov and Nagaitsev, showing that although there is fairly complex behavior over the course of a synchrotron oscillation, the Danilov-Nagaitsev invariants are nevertheless periodic with the synchrotron motion.

43 PARTICLE ACCELERATORS↗

Effects of Synchrotron Motion on Nonlinear Integrable Optics

An integrable Rapid-Cycling Synchrotron (iRCS) has been proposed as a replacement for the Fermilab Booster to achieve multi-MW beam power for the Fermilab high-energy neutrino program.* The successful application of nonlinear integrable optics to proton synchrotrons requires careful examination of single-particle longitudinal effects, especially synchrotron motion. For example, synchrobetatron coupling may excite transverse resonances in the ring. We will use the Synergia code to simulate the effects of this synchrobetatron coupling on the iRCS design with nonlinear inserts. Our goal will be to identify new invariants in the presence of this coupling. Assuming the synchrotron tune is sufficiently small, we have identified one or more adiabatic invariants of the motion. These invariants suggest that integrable optics with synchrobetatron coupling retains integrability when averaged over a synchrotron period.

43 PARTICLE ACCELERATORS↗

Experimental and synthetic measurements of polarized synchrotron emission from runaway electrons in Alcator C-Mod

This paper presents the first experimental analysis of polarized synchrotron emission from relativistic runaway electrons (REs) in a tokamak plasma. Importantly, we show that the polarization information of synchrotron radiation can be used to diagnose spatially-localized RE pitch angle distributions. Synchrotron-producing REs were generated during low density, Ohmic, diverted plasma discharges in the Alcator C-Mod tokamak. The ten-channel Motional Stark Effect diagnostic was used to measure spatial profiles of the polarization angle and the fraction of detected light that was linearly-polarized. Spatial transitions in the polarization angle of 90 degrees---from horizontal to vertical polarization and vice versa---are observed in experimental data and are well-explained by the gyro-motion of REs and high directionality of synchrotron radiation. Polarized synchrotron emission is modeled with the synthetic diagnostic SOFT; its output Green's (or detector response) functions reveal a critical RE pitch angle at which the polarization angle flips by 90 degrees and the polarization fraction is minimal. Using SOFT, we determine the dominant RE pitch angle which reproduces measured polarization angle and fraction values. The spatiotemporal evolutions of the polarization angle and fraction are explored in detail for one C-Mod discharge. For channels viewing REs near the magnetic axis and flux surfaces q = 1 and 4/3, disagreements between synthetic and experimental signals suggest that the sawtooth instability may be influencing RE dynamics. Furthermore, other sources of pitch angle scattering, not considered in this analysis, could help explain discrepancies between simulation and experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compton and synchrotron processes in spherically-symmetric non-thermal sources

A framework is developed for the accurate calculation of Compton and synchrotron processes in a special class of spherically-symmetric sources. The models considered take a distribution in magnetic field values and high-energy electron density that varies smoothly from central values to values at the outer boundary of the source. Further, the assumption is made that the magnetic field has local disorder (isotropy) and the high-energy electron distribution has local isotropy. Then, in terms of parameters of the source, the synchrotron brightness distribution, total synchrotron flux, Compton-synchrotron flux, and synchrotron self-absorption turnover are all computed accurately. Results are given with a view toward application to the analysis of compact non-thermal sources.

Gould, R. J.↗

Synchrotron radiation - Applications in the earth sciences

Synchrotron-radiation sources and their characteristics are overviewed along with recent synchrotron-based research on earth materials and future earth-science applications utilizing the next generation of synchrotron-radiation sources presently under construction. Focus is placed on X-ray scattering studies of earth materials (crystalline and noncrystalline) under ambient conditions, diffraction studies of earth materials at high pressures and/or temperatures, spectroscopic studies, primarily X-ray absorption spectroscopy, and spatially resolved X-ray fluorescence studies of compositional variations in earth materials. It is noted that other synchrotron-based methods, such as X-ray tomography and topography may become important in characterizing earth materials, while soft X-ray/vacuum ultraviolet radiation from synchrotron sources can be applied to problems involving the structural environments of low-atomic-number elements and the characterization of surface reactions of minerals with liquids and gases.

Bassett, W. A.↗

A Self Consistent 2D Simulation of Coherent Synchrotron Radiation Effects on Beam Dynamics

An increasing interest in high quality and high current electron beams necessitates a thorough understanding and prediction of coherent synchrotron radiation effects. The self-interaction of charged particles in a beam undergoing synchrotron motion is a physically significant process that is all too often computationally intensive with very little analytical results to rely on for the general case. The coherent spectrum of this interaction is of utmost importance to the design of free electron lasers (FELs) and an accurate assessment is imperative for their design. This work presents a novel implementation to the numerical simulation of charged particle beams. The simulation is a self-consistent approach including the self-fields generated by the beam of which coherent synchrotron radiation effects are of primary interest. A particle-in-cell model is used where a planar beam sampled by point particles is deposited on an encompassing grid at each timestep. The electromagnetic fields are calculated on the grid using the retarded potentials according to causality. The electromagnetic forces from the fields are interpolated on each particle which in turn advance in time. The simulation is benchmarked against well-established results for coherent synchrotron radiation effects. In addition, studies are provided that show the convergence of simulation results for increasing resolution. A study into the transverse beam size effects on beam dynamics is performed as well as a proof of concept where the simulation is used by a genetic algorithm to optimize the design parameters of a beam lattice. The results of these studies in tandem verify the efficacy of the simulation for its practical use in accelerator design or the study of synchrotron radiation effects

Duffin, Dallan [Old Dominion Univ., Norfolk, VA (U↗