Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchronized sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Photothermal behaviour of titanium nitride nanoparticles evaluated by transient X-ray diffraction

The photothermal properties of metal nitrides have recently received significant attention owing to diverse applications in solar energy conversion, photothermal therapies, photoreactions, and thermochromic windows. Here, the photothermal response of titanium nitride nanoparticles is examined using transient X-ray diffraction, in which optical excitation is synchronized with X-ray pulses to characterize dynamic changes in the TiN lattice. Photoinduced diffraction data is quantitatively analyzed to determine increases in the TiN lattice spacing, which are furthermore calibrated against static, temperature-dependent diffraction patterns of the same samples. Measurements of 20 nm and 50 nm diameter TiN nanoparticles reveal transient lattice heating from room temperature up to similar to 175 degrees C for the highest pump fluences investigated here. Increasing excitation intensity drives sublinear increases in lattice temperature, due to increased heat capacity at the higher effective temperatures achieved at higher powers. Temporal dynamics show that higher excitation intensity drives not only higher lattice temperatures, but also unexpectedly slower cooling of the TiN nanoparticles, which is attributed to heating of the solvent proximal to the nanoparticle surface.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The VLBA correlator: Real-time in the distributed era

The correlator is the signal processing engine of the Very Long Baseline Array (VLBA). Radio signals are recorded on special wideband (128 Mb/s) digital recorders at the 10 telescopes, with sampling times controlled by hydrogen maser clocks. The magnetic tapes are shipped to the Array Operations Center in Socorro, New Mexico, where they are played back simultaneously into the correlator. Real-time software and firmware controls the playback drives to achieve synchronization, compute models of the wavefront delay, control the numerous modules of the correlator, and record FITS files of the fringe visibilities at the back-end of the correlator. In addition to the more than 3000 custom VLSI chips which handle the massive data flow of the signal processing, the correlator contains a total of more than 100 programmable computers, 8-, 16- and 32-bit CPUs. Code is downloaded into front-end CPU's dependent on operating mode. Low-level code is assembly language, high-level code is C running under a RT OS. We use VxWorks on Motorola MVME147 CPU's. Code development is on a complex of SPARC workstations connected to the RT CPU's by Ethernet. The overall management of the correlation process is dependent on a database management system. We use Ingres running on a Sparcstation-2. We transfer logging information from the database of the VLBA Monitor and Control System to our database using Ingres/NET. Job scripts are computed and are transferred to the real-time computers using NFS, and correlation job execution logs and status flow back by the route. Operator status and control displays use windows on workstations, interfaced to the real-time processes by network protocols. The extensive network protocol support provided by VxWorks is invaluable. The VLBA Correlator's dependence on network protocols is an example of the radical transformation of the real-time world over the past five years. Real-time is becoming more like conventional computing. Paradoxically, 'conventional' computing is also adopting practices from the real-time world: semaphores, shared memory, light-weight threads, and concurrency. This appears to be a convergence of thinking.

Wells, D. C.↗

THIRTY NEW LOW-MASS SPECTROSCOPIC BINARIES

As part of our search for young M dwarfs within 25 pc, we acquired high-resolution spectra of 185 low-mass stars compiled by the NStars project that have strong X-ray emission. By cross-correlating these spectra with radial velocity standard stars, we are sensitive to finding multi-lined spectroscopic binaries. We find a low-mass spectroscopic binary fraction of 16% consisting of 27 SB2s, 2 SB3s, and 1 SB4, increasing the number of known low-mass spectroscopic binaries (SBs) by 50% and proving that strong X-ray emission is an extremely efficient way to find M-dwarf SBs. WASP photometry of 23 of these systems revealed two low-mass eclipsing binaries (EBs), bringing the count of known M-dwarf EBs to 15. BD-22 5866, the ESB4, was fully described in 2008 by Shkolnik et al. and CCDM J04404+3127 B consists of two mid-M stars orbiting each other every 2.048 days. WASP also provided rotation periods for 12 systems, and in the cases where the synchronization time scales are short, we used P{sub rot} to determine the true orbital parameters. For those with no P{sub rot}, we used differential radial velocities to set upper limits on orbital periods and semimajor axes. More than half of our sample has near-equal-mass components (q > 0.8). This is expected since our sample is biased toward tight orbits where saturated X-ray emission is due to tidal spin-up rather than stellar youth. Increasing the samples of M-dwarf SBs and EBs is extremely valuable in setting constraints on current theories of stellar multiplicity and evolution scenarios for low-mass multiple systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Literature Review of Generalized Two-Dimensional Correlation Spectroscopy (2D-COS)

Generalized two-dimensional correlation spectroscopy (2D-COS) is a technique that has improved on traditional spectroscopic techniques by exposing samples to a variable amount of an external perturbation before they have been probed spectroscopically through IR, UV, Raman, etc. These perturbed signals are plotted over a second independent wavenumber axis and after mathematical manipulation, a dynamic spectrum is created that shows the synchronous and asynchronous spectra. The dynamic spectrum shows the way spectral changes in the material are correlated to each other, and a mechanism of material degradation can be proposed through a set of rules that Noda proposed. This technique is important to spectroscopic studies because of improved spectral resolution and the identification of complex or overlapping bands that cannot be distinguished in traditional analytical methods. This technique has been widely utilized since its inception, and has developed towards protein studies, as well as even wine chemistry, because of the advanced capabilities of band separation. Two-dimensional hetero-spectral correlation analysis has also been developed to find correlations in spectra with different spectroscopic probes. 2D-COS as an analytical technique has increasing avenues of expansion, and can be creatively used in many other fields in the future.

2D-COS↗

Coincident particle observations from AE-C and ATS 6 during the October 28, 1977, geomagnetic storm

Simultaneous measurements of ion and electron energy spectra recorded during the October 28, 1977 geomagnetic storm by the AE-C and ATS 6 spacecraft when both were nearly on the same L shell are evaluated and compared. The orbit of the AE-C generates wide longitudinal coverage of the auroral oval, whereas the ATS 6, which is located at geosynchronous orbit, samples the equatorial particle population. It is shown that the coincident electron energy spectra obtained by the two satellites agree well above 5 keV and the spectra of electrons peak near 1 keV at ionospheric altitudes, while no peaks in energy appear at synchronous altitude.

Zanetti, L. J.↗

Cloud cover sampling capability of various satellite combinations for ISCCP

One of the most important objectives of the International Satellite Cloud Climatology Project (ISCCP) is the quantification of cloud cover and associated radiation parameters for climate research. The time-varying nature of cloud cover requires a measurement system that obtains cloud radiance at sufficient time intervals for determining accurate values of cloudiness for the appropriate averaging period. Current plans for the ISCCP call for such day to be acquired every 3 hours during both data and night to ensure that the diurnal cycle of cloud cover is adequately sampled. The satellite system proposed is an array of geostationary and polar-orbiting satellites. The error in mean cloud cover estimates for observation systems which do not include geostationary satellites are quantified. Candidates for such a system include two NOAA Sun-synchronous satellites with daylight equatorial-crossing times of 0730 and 1430, and a USSR satellite in an 81 deg. inclination, 900-km altitude orbit.

Harrison, E. F.↗

Resonant propagation of extreme-ultraviolet pulses through strongly driven high-density media

We show that by combining strong-field dressing and resonant propagation of XUV pulses, the transition of absorption lines from their natural Lorentzian profiles through Fano and complex multipeak shapes all the way back to broadened near-Lorentzian profiles can be achieved, in the limit of optically thick samples. The final stage of this spectral modification can be understood in terms of a significant temporal stretching and delay of the resonant XUV pulse as it propagates through the dense gas, which alters the ultrafast absorption that is modified by the time-synchronized few-femtosecond laser pulse. We first demonstrate this concept in numerical calculations, both using a model system and through a fully coupled solution of the time-dependent Schrödinger equation and the Maxwell wave equation. The applicability and generality of the underlying mechanism is then illustrated in proof-of-principle attosecond transient absorption measurements in a helium gas with a widely varying atomic density. These results provide insights into the interaction of ultrashort laser pulses with dense media and its coherent control. Published by the American Physical Society 2025

He, Yu (ORCID:0000000152120176)↗

Accelerated Dimension-Independent Adaptive Metropolis

This work describes improvements from algorithmic and architectural means to black-box Bayesian inference over high-dimensional parameter spaces. The well-known adaptive Metropolis (AM) algorithm [33] is extended herein to scale asymptotically uniformly with respect to the underlying parameter dimension for Gaussian targets, by respecting the variance of the target. The resulting algorithm, referred to as the dimension-independent adaptive Metropolis (DIAM) algorithm, also shows improved performance with respect to adaptive Metropolis on non-Gaussian targets. This algorithm is further improved, and the possibility of probing high-dimensional (with dimension d 1000) targets is enabled, via GPU-accelerated numerical libraries and periodically synchronized concurrent chains (justi ed a posteriori). Asymptotically in dimension, this GPU implementation exhibits a factor of four improvement versus a competitive CPU-based Intel MKL parallel version alone. Strong scaling to concurrent chains is exhibited, through a combination of longer time per sample batch (weak scaling) and yet fewer necessary samples to convergence. The algorithm performance is illustrated on several Gaussian and non-Gaussian target examples, in which the dimension may be in excess of one thousand.

97 MATHEMATICS AND COMPUTING↗

Statistical studies in stellar rotation 2: A method of analyzing rotational coupling in double stars and an introduction to its applications

The correlation between the equatorial velocities of the components of double stars is studied from a statistical standpoint. A theory of rotational correlation is developed and discussed with regard to its applicability to existing observations. The theory is then applied to a sample of visual binaries which are the least studied for rotational coupling. Consideration of eclipsing systems and spectroscopic binaries is limited to show how the degrees of freedom in the spin parallelism problem can be reduced. The analysis lends support to the existence of synchronism in closely spaced binaries.

Bernacca, P. L.↗

On-site Real-Time Inspection System for Pump-impeller using X-band Linac X-ray Source

The methods of nondestructive testing (NDT) are generally ultrasonic, neutron, eddy-current and X-rays, NDT by using X-rays, in particular, is the most useful inspection technique having high resolution. We can especially evaluate corroded pipes of petrochemical complex, nuclear and thermal-power plants by the high energy X-ray NDT system. We develop a portable X-ray NDT system with X-band linac and magnetron. This system can generate a 950 keV electron beam. We are able to get X-ray images of samples with 1 mm spatial resolution. This system has application to real time impeller inspection because linac based X-ray sources are able to generate pulsed X-rays. So, we can inspect the rotating impeller if the X-ray pulse rate is synchronized with the impeller rotation rate. This system has application in condition based maintenance (CBM) of nuclear plants, for example. However, 950 keV X-ray source can only be used for thin tubes with 20 mm thickness. We have started design of a 3.95 MeV X-band linac for broader X-ray NDT application. We think that this X-ray NDT system will be useful for corrosion wastage and cracking in thicker tubes at nuclear plants and impeller of larger pumps. This system consists of X-band linac, thermionic cathode electron gun, magnetron and waveguide components. For achieving higher electric fields the 3.95 MeV X-band linac structure has the side-coupled acceleration structure. This structure has more efficient acceleration than the 950 keV linac with alternating periodic structure (APS). We adopt a 1.3 MW magnetron for the RF source. This accelerator system is about 30 cm long. The beam current is about 150 mA, and X-ray dose rate is 10 Gy at 1 m/500 pps. In this paper, the detail of the whole system concept and the electromagnetic field of designed linac structure will be reported.

43 PARTICLE ACCELERATORS↗

TH-EF-BRA-06: A Novel Retrospective 3D K-Space Sorting 4D-MRI Technique Using a Radial K-Space Acquisition MRI Sequence

Purpose: Current retrospective 4D-MRI provides superior tumor-to-tissue contrast and accurate respiratory motion information for radiotherapy motion management. The developed 4D-MRI techniques based on 2D-MRI image sorting require a high frame-rate of the MR sequences. However, several MRI sequences provide excellent image quality but have low frame-rate. This study aims at developing a novel retrospective 3D k-space sorting 4D-MRI technique using radial k-space acquisition MRI sequences to improve 4D-MRI image quality and temporal-resolution for imaging irregular organ/tumor respiratory motion. Methods: The method is based on a RF-spoiled, steady-state, gradient-recalled sequence with minimal echo time. A 3D radial k-space data acquisition trajectory was used for sampling the datasets. Each radial spoke readout data line starts from the 3D center of Field-of-View. Respiratory signal can be extracted from the k-space center data point of each spoke. The spoke data was sorted based on its self-synchronized respiratory signal using phase sorting. Subsequently, 3D reconstruction was conducted to generate the time-resolved 4D-MRI images. As a feasibility study, this technique was implemented on a digital human phantom XCAT. The respiratory motion was controlled by an irregular motion profile. To validate using k-space center data as a respiratory surrogate, we compared it with the XCAT input controlling breathing profile. Tumor motion trajectories measured on reconstructed 4D-MRI were compared to the average input trajectory. The mean absolute amplitude difference (D) was calculated. Results: The signal extracted from k-space center data matches well with the input controlling respiratory profile of XCAT. The relative amplitude error was 8.6% and the relative phase error was 3.5%. XCAT 4D-MRI demonstrated a clear motion pattern with little serrated artifacts. D of tumor trajectories was 0.21mm, 0.23mm and 0.23mm in SI, AP and ML directions, respectively. Conclusion: A novel retrospective 3D k-space sorting 4D-MRI technique has been developed and evaluated on human digital phantom. NIH (1R21CA165384-01A1)

60 APPLIED LIFE SCIENCES↗

The Mars Observer database

Mars Observer will study the surface, atmosphere, and climate of Mars in a systematic way over an entire Martian year. The observations of the surface will provide a database that will be invaluable to the planning of a future Mars sample return mission. Mars Observer is planned for a September 1992 launch from the Space Shuttle, using an upper-stage. After the one year transit the spacecraft is injected into orbit about Mars and the orbit adjusted to a near-circular, sun-synchronous low-altitude, polar orbit. During the Martian year in this mapping orbit the instruments gather both geoscience data and climatological data by repetitive global mapping. The scientific objectives of the mission are to: (1) determine the global elemental and mineralogical character of the surface material; (2) define globally the topography and gravitational field; (3) establish the nature of the magnetic field; (4) determine the time and space distribution, abundance, sources, and sinks of volatile material and dust over a seasonal cycle; and (5) explore the structure and aspects of the circulation of the atmosphere. The science investigations and instruments for Mars Observer have been chosen with these objectives in mind. These instruments, the principal investigator or team leader and the objectives are discussed.

Albee, Arden L.↗

The earth radiation budget satellite system for climate research

The mission implications of providing earth radiation budget data for climate studies have been thoroughly studied. The results of these studies indicate the need for a multisensor, multisatellite system consisting of high and midinclination orbits. To meet this need, NASA and NOAA are planning a joint Earth Radiation Budget Satellite System (ERBSS) composed of instruments on two of NOAA's near-polar Sun-synchronous TIROS-N/NOAA A through G series of operational satellites and on an NASA midinclination satellite of the Applications Explorer Mission (AEM) type referred to as ERBS-A/AEM. This paper describes the scientific objectives of ERBSS, the associated data analysis methods, mission analysis (sampling), and instrument definition.

Woerner, C. V.↗

Synchronized Electronic Shutter System and Method for Thermal Nondestructive Evaluation

The invention is a synchronized electronic shutter system (SESS) and method for same side and through transmission thermal analysis and inspection of a material for finding defects, corrosion, disbond defects, integrity of a weld and determination of paint thickness. The system comprises an infrared detector that acquires background images of the sample. A shutter then covers the detector and lamps rapidly heat the sample above ambient temperature. Shutters cover all lamps at the same time the shutter over the infrared detector is opened. The infrared detector acquires a series of temperature images over time radiated from the sample a s the sample cools down. After collecting a series of temperature images taken by the SESS, a processed image is developed using one of the group comprising time derivative calculation, temperature normalization data reduction routine, thermal diffusivity curve fitting and averaging the series of temperature images.

Joseph N Zalameda↗

Motion Parameters Determination of the SC and Phobos in the Project Phobos-Grunt

The SC "Phobos-Grunt" flight is planned to 2009 in Russia with the purpose to deliver to the Earth the soil samples of the Mars satellite Phobos. The mission will pass under the following scheme [1-4]: the SC flight from the Earth to the Mars, the SC transit on the Mars satellite orbit, the motion round the Mars on the observation orbit and on the quasi-synchronous one [5], landing on Phobos, taking of a ground and start in the direction to the Earth. The implementation of complicated dynamical operations in the Phobos vicinity is foreseen by the project. The SC will be in a disturbance sphere of gravitational fields from the Sun, the Mars and the Phobos. The SC orbit determination is carried out on a totality of trajectory measurements executed from ground tracking stations and measurements of autonomous systems onboard space vehicle relatively the Phobos. As ground measurements the radio engineering measurements of range and range rate are used. There are possible as onboard optical observations of the Phobos by a television system and ranges from the SC up to the Phobos surface by laser locator. As soon as the Phobos orbit accuracy is insufficient for a solution of a problem of landing its orbit determination will be carried out together with determination of the SC orbit. Therefore the algorithms for joint improving of initial conditions of the SC and the Phobos are necessary to determine parameters of the SC relative the Phobos motion within a single dynamical motion model. After putting on the martial satellite orbit, on the Phobos observation orbit, on the quasi-synchronous orbit in the Phobos vicinity the equipment guidance and the following process of the SC orbit determination relatively Phobos requires a priori knowledge of the Phobos orbit parameters with sufficiently high precision. These parameters should be obtained beforehand using both all modern observations and historical ones.

Akim, E. L.↗

Temporal dynamics of protein and post-translational modification abundances in Populus leaf across a diurnal period

Populus spp. are dedicated woody biomass feedstocks for advanced biofuels and bioproducts. Proper growth and fitness of poplar as a sustainable feedstock depends on timely perception and response to environmental signals (e.g., light, temperature, water). Poplar leaves, like other C3 photosynthesis plants, have evolved oscillating or circadian rhythms that play important roles in synchronizing biological processes with external cues. To characterize this phenomenon at a molecular level, we employed bottom-up proteomics using high-resolution mass spectrometry and de novo-assisted database searching to identify abundance changes in proteins and post-translational modifications in poplar leaf tissue sampled across a 12/12-hour light/dark diurnal period.

09 BIOMASS FUELS↗

Observations of the Ca II infrared triplet in chromospherically active single and binary stars

Spectroscopic observations of the Ca II infrared triplet (8498, 8542, 8662 A) have been obtained for 45 stars which are known or suspected to be chromospherically active. The sample includes both single and binary stars of spectral types from F2 to M5 spanning luminosity classes III, IV, and V. Several different types of activity diagnostics were measured, and their relative merits are discussed. Dependence of chromospheric emission upon rotation period, luminosity, temperature, and duplicity are analyzed. Synchronous binaries show a slight trend of increased emission with decreasing period while the asynchronous binaries show abnormally high activity levels for their rotation periods. Several stars exhibit rotationally modulated emission which is anticorrelated with the stellar brightness. Finally, estimates of chromospheric energy losses are presented with the result that the total loss in the infrared triplet is about twice that of the H and K lines.

Dempsey, Robert C.↗

MO-A-BRD-06: In Vivo Cherenkov Video Imaging to Verify Whole Breast Irradiation Treatment

Purpose: To show in vivo video imaging of Cherenkov emission (Cherenkoscopy) can be acquired in the clinical treatment room without affecting the normal process of external beam radiation therapy (EBRT). Applications of Cherenkoscopy, such as patient positioning, movement tracking, treatment monitoring and superficial dose estimation, were examined. Methods: In a phase 1 clinical trial, including 12 patients undergoing post-lumpectomy whole breast irradiation, Cherenkov emission was imaged with a time-gated ICCD camera synchronized to the radiation pulses, during 10 fractions of the treatment. Images from different treatment days were compared by calculating the 2-D correlations corresponding to the averaged image. An edge detection algorithm was utilized to highlight biological features, such as the blood vessels. Superficial dose deposited at the sampling depth were derived from the Eclipse treatment planning system (TPS) and compared with the Cherenkov images. Skin reactions were graded weekly according to the Common Toxicity Criteria and digital photographs were obtained for comparison. Results: Real time (fps = 4.8) imaging of Cherenkov emission was feasible and feasibility tests indicated that it could be improved to video rate (fps = 30) with system improvements. Dynamic field changes due to fast MLC motion were imaged in real time. The average 2-D correlation was about 0.99, suggesting the stability of this imaging technique and repeatability of patient positioning was outstanding. Edge enhanced images of blood vessels were observed, and could serve as unique biological markers for patient positioning and movement tracking (breathing). Small discrepancies exists between the Cherenkov images and the superficial dose predicted from the TPS but the former agreed better with actual skin reactions than did the latter. Conclusion: Real time Cherenkoscopy imaging during EBRT is a novel imaging tool that could be utilized for patient positioning, movement tracking, treatment monitoring, superficial dose and skin reaction estimation and prediction.

60 APPLIED LIFE SCIENCES↗