Causes of and Solutions to Wind Speed Bias in NREL's 2020 Offshore Wind Resource Assessment for the California Pacific Outer Continental Shelf

This report provides the results of a detailed analysis into the causes of high wind speed bias in the 20-year wind resource data set for offshore California the National Renewable Energy Laboratory (NREL) released in 2020, herein called CA20. The data set was developed using the state-of-the-art Weather Research and Forecasting (WRF) model. Notably, no floating lidars were available at the time in offshore California to validate offshore hub-height wind speeds. In late 2020, the Pacific Northwest National Laboratory (PNNL) deployed two floating lidars in the California outer continental shelf (OCS), near the Bureau of Ocean Energy Management (BOEM) call areas of Humboldt and Morro Bay. Using these observations through 2021, NREL found considerable bias in modeled hub-height winds at both locations: up to +2 m/s at Humboldt over a 6-month period, and up to +1 m/s at Morro Bay over a one-year period. Upon the discovery of this bias, the Department of Energy (DOE) and BOEM funded NREL and PNNL to investigate the causes of, impacts of, and solutions to the bias in the CA20 data set. This report summarizes the findings of this research. We first investigated whether different WRF model setups could lead to reduced bias. We found that the choice of planetary boundary layer (PBL) scheme - which controls the vertical turbulent mixing of momentum, heat, and moisture in the lowermost part of the atmosphere - greatly affected hub-height wind speeds in the region. Specifically, switching from the Mellor-Yamada-Nakanishi-Niino (MYNN) scheme used in CA20 (and widely used across a range of operational and research weather models) to the less common Yonsei University (YSU) scheme nearly eliminated the bias at both the Humboldt and Morro Bay lidar locations. The large discrepancy between the MYNN- and YSU-modeled hub-height winds pointed towards the role of atmospheric stability. In general, PBL schemes agree well in conditions of high turbulence and mixing, normally referred to as "unstable" conditions. By contrast, PBL schemes start to diverge in "stable" conditions, where turbulence is low and thermal stratification (i.e., higher temperature air sitting on top of colder air) greatly suppresses vertical mixing. Under such conditions, winds aloft can decouple from surface effects and greatly accelerate, causing high wind speeds at hub-height and frequent low-level jets (LLJs). We determined that these stable conditions are in fact dominant in offshore California. The region is characterized by moderate-to-extreme stable stratification with a LLJ on average around 200 meters above sea-level. To our knowledge, no wind energy area globally has as strongly stable stratification as offshore California. Under these extreme conditions, we determined that the MYNN scheme models higher stability than YSU, resulting in less vertical turbulent mixing than YSU, allowing for the acceleration of hub-height winds, more intense LLJs, and higher-amplitude inertial oscillations. Using surface observations, we found that MYNN overestimates near-surface stability, whereas YSU tends to model stability better. We then considered several short-term case studies to assess additional meteorological drivers of the bias at Humboldt. We found that during synoptic scale northerly flows driven by the North Pacific High and inland thermal low, a coastal warm bias in the MYNN case studies contributes to the modeled wind speed bias by altering the boundary layer thermodynamics via a thermal wind mechanism. Given the strong performance of the YSU-based runs in offshore California, NREL has produced and published an updated version of the CA20 data set with YSU as the PBL scheme. This updated data set is now part of NREL's 2023 National Offshore Wind (NOW-23) data set, which covers all the U.S. offshore waters. The development and final validation of the NOW-23 data set in offshore California is documented in this report.

17 WIND ENERGY↗

Dynamic control of nonequilibrium metal-insulator transitions

Here, we demonstrate a first order metal-insulator phase transition in the repulsive, fully frustrated, single-band Hubbard model as a function of the coupling to a fermion bath. Time dependent manipulation of the bath coupling allows switching between metallic and insulating states both across the phase transition and within the coexistence region. We propose a simple nanoelectronic device for experimentally realizing dynamic control of the bath coupling. Analysis of the device characteristics shows that it can act as a two-terminal memristor.

36 MATERIALS SCIENCE↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

Futures for electrochromic windows on high performance houses in arid, cold climates

This study investigates high performance electrochromic windows used on a passive house and residential dwelling to IECC 2021 (i.e., IECC dwelling). In the lab, the electrochromic film switches transmitted solar heat gain coefficient (SHGC) from 0.09 to 0.7 and visible transmittance from 0.15 to 0.82 with power consumption of 1.23 W/m 2 during switching times less than 3 minutes. We extrapolate these results to a window assembly. Building energy models of the houses were evaluated in Santa Fe, New Mexico. A Monte Carlo analysis for 2020, 2040, 2060, and 2080 was conducted for Shared Socioeconomic Pathways 2-4.5, 3-7.0, and 5-8.5. Cases with and without the electrochromic windows and with and without electricity were used to determine energy use intensity and hours beyond thermal safety thresholds. The passive house showed 1.3-3.1% mean energy savings and the IECC dwelling 4.4-5.1% with electrochromic efficiency benefits growing into the future for both cases. Even so, overall savings decrease into the future for the passive house, due to growth in cooling load being dominant, conversely overall energy savings increase into the future for the IECC dwelling due to heating loads being dominant. For thermal resilience, the passive house exhibited a mean percent decrease of 0.02-0.31% hours in the extreme caution (i.e., > 32.2 °C, ≤ 39.4 °C) range while the IECC dwelling exhibited 0.38-4.38%. The study therefore shows that electrochromic windows will have smaller benefits for the passive house in comparison to the IECC dwelling. The relationship between electrochromic windows is shown to have a complex relationship between house efficiency and climate change by these results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deuteration removes quantum dipolar defects from KDP crystals

Abstract Dielectric properties of the hydrogen-bonded ferroelectric crystal KH 2 PO 4 (KDP) differ significantly from those of KD 2 PO 4 (DKDP). It is well established that deuteration affects the interplay of hydrogen-bond switches and heavy ion displacements that underlie the emergence of macroscopic polarization, but a detailed microscopic model is missing. We show that all-atom path integral molecular dynamics simulations can predict the isotope effects, revealing the microscopic mechanism that differentiates KDP and DKDP. Proton tunneling generates phosphate configurations that do not contribute to the polarization. At low temperatures, these quantum dipolar defects are substantial in KDP but negligible in DKDP. These intrinsic defects explain why KDP has lower spontaneous polarization and transition entropy than DKDP. The prominent role of quantum fluctuations in KDP is related to the unusual strength of the hydrogen bonds and should be equally important in other crystals of the KDP family, which exhibit similar isotope effects.

Yang, Bingjia (ORCID:0000000340749553)↗

A driven Kerr oscillator with two-fold degeneracies for qubit protection

We present the experimental finding of multiple simultaneous two-fold degeneracies in the spectrum of a Kerr oscillator subjected to a squeezing drive. This squeezing drive resulting from a three-wave mixing process, in combination with the Kerr interaction, creates an effective static two-well potential in the phase space rotating at half the frequency of the sinusoidal drive generating the squeezing. Remarkably, these degeneracies can be turned on-and-off on demand, as well as their number by simply adjusting the frequency of the squeezing drive. We find that when the detuning Δ between the frequency of the oscillator and the second subharmonic of the drive equals an even multiple of the Kerr coefficient K , Δ / K = 2 m , the oscillator displays m + 1 exact, parity-protected, spectral degeneracies, insensitive to the drive amplitude. These degeneracies can be explained by the unusual destructive interference of tunnel paths in the classically forbidden region of the double well static effective potential that models our experiment. Exploiting this interference, we measure a peaked enhancement of the incoherent well-switching lifetime, thus creating a protected cat qubit in the ground state manifold of our oscillator. Our results illustrate the relationship between degeneracies and noise protection in a driven quantum system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Uncertainty Quantification of Capacitor Switching Transient Location using Machine Learning

Identification of capacitor switching transient location provides valuable insight into the state of the associated equipment. Machine learning (ML) models, and convolutional neural networks (CNNs) in particular, have demonstrated remarkable performance in signal location. However, ML models are data driven whose predictions are affected by noise in data and may also suffer from large extrapolation errors when applied to new conditions. Uncertainty quantification (UQ) is necessary to ensure model trustworthiness and avoid overconfident predictions in extrapolation. Here, in this work, we propose a novel UQ method, called PI3NN, to quantify prediction uncertainty of ML models and integrate the method with CNNs for transient source location. PI3NN calculates Prediction Intervals by training 3 Neural Networks and uses root-finding methods to determine the interval precisely. Additionally, PI3NN can identify out-of-distribution (OOD) data in a nonstationary condition to avoid overconfident prediction. Results indicate that with PI3NN, transient signals are not only correctly identified, but when said signals are subject to corruptions characteristic of an actual power monitoring system (e.g. non-ideal sensors), the model recognizes when it is uncertain about its predictions, effectively letting the user know when to accept or discard the results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Switching between Magnetic Bloch and Néel Domain Walls with Anisotropy Modulations

It has been shown previously that the presence of a Dzyaloshinskii-Moriya interaction in perpendicularly magnetized thin films stabilizes N\'eel type domain walls. We demonstrate, using micromagnetic simulations and analytical modeling, that the presence of a uniaxial in-plane magnetic anisotropy can also lead to the formation of N\'eel walls in the absence of a Dzyaloshinskii-Moriya interaction. It is possible to abruptly switch between Bloch and N\'eel walls via a small modulation of both the in-plane, but also the perpendicular magnetic anisotropy. This opens up a route towards electric field control of the domain wall type with small applied voltages through electric field controlled anisotropies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

End-to-End Modeling of the TDM Readout System for CMB-S4

The CMB-S4 experiment is developing next-generation ground-based microwave telescopes to observe the cosmic microwave background with unprecedented sensitivity. This will require an order of magnitude increase in the 100-mK detector count, which, in turn, increases the demands on the readout system. The CMB-S4 readout will use time-division multiplexing (TDM), taking advantage of faster switches and amplifiers in order to achieve an increased multiplexing factor. To facilitate the design of the new readout system, we have developed a model that predicts the bandwidth and noise performance of this circuitry and its interconnections. This is then used to set requirements on individual components in order to meet the performance necessary for the full system. Here, we present an overview of this model and compare the model results to the performance of both legacy and prototype readout hardware.

47 OTHER INSTRUMENTATION↗

A thermally-limited bubble growth model for the relaxation time of superheated fuels

Here, we propose a novel approach to evaluate the relaxation time of vapor bubble growth in the context of the flash boiling of a superheated liquid. In alternative to the empirical correlation derived from superheated water experiments almost fifty years ago, the new model describes the thermally-dominated growth of vapor bubbles in terms that are dependent on the local Jakob number (the ratio of sensible heat to latent heat during phase change) and the number density of vapor bubbles. The model is tested by plugging the resulting relaxation time into the Homogenous Relaxation Model (HRM). Flash-boiling simulations carried out with HRM are compared with n-pentane (C 5 H 12 ) injection and boil-off experiments conducted with a real-size, axial-hole, transparent gasoline injector discharging into a constant-pressure vessel. The long-distance microscopy images from the experiments, processed to derive the projected liquid volume (PLV) of the spray, provide a unique set of time-resolved validation data for direct fuel injection simulations. At conditions ranging from flaring to mild and minimal flash boiling, we show that switching to the new relaxation time improves the agreement with the measured PLV profiles with respect to the standard empirical model. Particularly at flaring conditions, the predicted increase in gas cooling caused by rapid vapor production is shown to be more consistent with the observed boil-off.

42 ENGINEERING↗

Towards an “$\mathrm{AdS}_1$/$\mathrm{CFT}_0$” correspondence from the $\mathrm{D}$(-1)/$\mathrm{D}$7 system?

We argue that a type IIB Euclidean supergravity solution of the form $\mathbb{R}$ x S 1 x $\mathbb{T}$ 8 with imaginary self-dual F 1 flux through $\mathbb{R}$ x S 1 belongs to the chain of AdS d x S d x $\mathbb{T}$ 10-2d vacua with (imaginary) self-dual Fd flux, where d ≤ 5. Such vacua come from the near-horizon of D(d - 2)/D(8 - d) branes and are supersymmetric for odd values of d. For d = 1 we speculate that the hallmark of conformal symmetry for the matrix model dual is a vanishing free energy. The matrix dual was recently constructed by [1] by adding matrix interactions coming from strings stretching between the D(-1) and D7 branes to the IKKT matrix model. We find that the corresponding supergravity solution indeed has vanishing on-shell action. Specific F 5 fluxes need to be switched on as a consequence of (a T-dual version of) the Hanany-Witten effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Feed-Forward Compensation for Model Predictive Control in Tri-port Current-Source Medium-Voltage String Inverters for PV-Plus-Storage Farms

The novel tri-port current-source medium-voltage string inverter (TCS-MVSI) is a promising candidate for large-scale PV-plus-storage (PVS) farms owing to its galvanic isolation, easy storage integration, soft-switching capability across entire load range, controlled low dv/dt and EMI, benign fault tolerance, etc. Due to its low inertia feature, traditional PI-based control cannot manage large transients effectively. Instead, a model-based predictive control (MPC) is proposed to achieve robust and stable operation. As is well known, the control performance of MPC is compromised by the sampling and computational delay during implementation significantly, if not well addressed. This paper analyzed and quantified these delays and then proposes feed-forward compensation (FFC) for the MPC method to compensate the delays and the large parameter variations due to the low-inertia nature. In addition, this method also compensates for the high dc-link ripple within each switching cycle, a unique issue for low-inertia converters. Here, the proposed method requires low computational effort, allowing it to be extended for multiple ports. The effectiveness of the proposed method has been validated in experiments. In 10 kW test, the proposed method decreases the average dc-link current by 17%, leading to ~20% conduction losses and ~0.5% increase in converter efficiency. In addition, the peak dc-link current also decreases by 15%, resulting in reduced transformer size. As a result, an increased power density can be achieved with the proposed method. Similar improvements have been observed across the power range from 2 kW to 10 kW.

30 DIRECT ENERGY CONVERSION↗

A two-stage service restoration method for electric power distribution systems

Improving the reliability of power distribution systems is critically important for both utilities and customers. This calls for an efficient service restoration module within a distribution management system to support the implementation of self-healing smart grid networks. Although the emerging smart grid technologies, including distributed generators (DGs) and remote-controlled switches, enhance the self-healing capability and allow faster recovery, they still pose additional complexity to the service restoration problem, especially under cold load pickup (CLPU) conditions. Herein, a novel two-stage restoration framework is proposed to generate a restoration solutions with a sequence of control actions. The first stage generates a restoration plan that supports both the traditional service restoration using feeder reconfiguration and the grid-forming DG-assisted intentional islanding methods. The second stage generates an optimal sequence of switching operations to bring the outaged system quickly to the final restored configuration. The problem is formulated as a mixed-integer linear program that incorporates system connectivity, operating constraints, and the CLPU models. It is demonstrated that on using a multi-feeder test case, the proposed framework is effective in utilizing all available resources to quickly restore the service and generate an optimal sequence of switching actions to be used by the operator to reach the desired optimal configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tunable Microwave Conductance of Nanodomains in Ferroelectric PbZr 0.2 Ti 0.8 O 3 Thin Film

Ferroelectric materials exhibit spontaneous polarization that can be switched by electric field. Beyond traditional applications as nonvolatile capacitive elements, the interplay between polarization and electronic transport in ferroelectric thin films has enabled a path to neuromorphic device applications involving resistive switching. A fundamental challenge, however, is that finite electronic conductivity may introduce considerable power dissipation and perhaps destabilize ferroelectricity itself. In this work, tunable microwave frequency electronic response of domain walls injected into ferroelectric lead zirconate titanate (PbZr 0.2 Ti 0.8 O 3 ) on the level of a single nanodomain is revealed. Tunable microwave response is detected through first-order reversal curve spectroscopy combined with scanning microwave impedance microscopy measurements taken near 3 GHz. Contributions of film interfaces to the measured AC conduction through subtractive milling, where the film exhibited improved conduction properties after removal of surface layers, are investigated. Using statistical analysis and finite element modeling, we inferred that the mechanism of tunable microwave conductance is the variable area of the domain wall in the switching volume. These observations open the possibilities for ferroelectric memristors or volatile resistive switches, localized to several tens of nanometers and operating according to well-defined dynamics under an applied field.

36 MATERIALS SCIENCE↗

Black-to-Transmissive dual polymer complementary electrochromics with high coloration efficiency

In a complementary electrochromic device (ECD), both the anode and the cathode can synergistically change color in response to an electrical bias, allowing for a high coloration efficiency. Complementary ECD that can switch from black to transmissive state is rare, due to the difficulty of pairing two electrochromic electrodes. In this study, we report the construction of high coloration efficiency complementary ECDs by pairing polyazoisoindigo (PAI), an n-type electrochromic polymer that undergoes green-to-transmissive switching, with p-type magenta (ECP-M) and red (ECP-R) electrochromic polymers to obtain black-to-transmissive ECD. Physical modeling tool, COMSOL, is introduced for complementary color matching. Through balancing the charge densities of two electrochromic electrodes, black-to-transmissive ECDs with record-high coloration efficiencies of 688 cm 2 /C and 437 cm 2 /C have been achieved for PAI|ECP-M and PAI|ECP-R, respectively. This study provides a general protocol for the design and fabrication of complementary ECDs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DC Microgrid Reliability Enhancement with Adaptive Converter Thermal Management

Due to the different device selections, aging levels, and thermal dissipation performance, some converters may take additional thermal stress on switching devices than others in paralleled converter systems, which will reduce system reliability. To address this problem, this paper proposes a power-sharing strategy with adaptive thermal management. First, the temperature-based power loss model and electrical-thermal model are established. Based on that, a high-accuracy IGBT junction temperature estimate considering the power loss-temperature coupling can be achieved. Further, the thermal-sharing for all the switching devices in paralleled converters can be achieved with the proposed adaptive thermal management strategy. The proposed strategy can change the power-sharing ratio adaptively according to the system operation conditions, which will contribute to the system reliability enhancement. The effectiveness of the proposed strategy is verified through PLECS thermal simulation and joint real-time simulation with Dspace and RT-box.

DC microgrid↗

A Data-Driven Passive Islanding Detection Scheme

This paper proposes a novel statistical parameters based data driven approach for passive islanding detection. The proposed scheme relies in the voltage data, measured at the point of common coupling, and is comprised of three stages. The Stage-1 quickly detects what is termed as coarse islanding, Stage-2 computes the decaying DC detector (DDCD), and 3) finally, the digital relay logic (DRL) is devised in Stage-3. The proposed scheme is tested as per the IEEE-1547, UL 1741 and IEC-62116 standards. Various tests are investigated on the modified IEEE-13 bus system, modeled in PSCAD/EMTDC, under stringent test scenarios such as power mismatch, induction motor starting effect, capacitor bank switching and various level of loads changes, considered for both single and multiple DG systems. The test results reveal that the proposed scheme can detect islanding in less than 2 cycles, and results in nearly zero non detection zone (NDZ). Also, the scheme can very well be used for single-phase microgrids too as it relies only on the single phase voltage information.

anti-islanding protection↗

Amorphous Indium Oxide Channel FEFETs With Write Voltage of 0.9 V and Endurance >10 12 for Refresh-Free Embedded Memory

This work presents, for the first time, a back-end-of-the-line (BEOL)-compatible W-doped indium oxide (IWO) ferroelectric field-effect transistor (FEFET) with a record-low operating voltage below 0.9 V and a write speed of 20 ns while achieving a transient read current window (CW) ratio ( I LVT /I HVT ) greater than 10 4 . The device also exhibits exceptional reliability characteristics such as: 1) measured bipolar write endurance up to 10 12 cycles; 2) a fast read speed of 50 ns; 3) read endurance surpassing 10 12 cycles; and 4) retention exceeding 10 4 s at 85 ∘ C. Furthermore, a physics-based numerical model has been developed to investigate the nanoscale characteristics of BEOL FEFET devices, leveraging nucleation-limited switching in HfO 2 ferroelectrics and dc characterization to extract material and channel parameters for accurate device simulation. The simulation uncovers the stochastic switching behavior of BEOL amorphous oxide semiconductor (AOS) FEFETs and demonstrates an intrinsic switching time as low as 1 ps, highlighting the potential of BEOL AOS FEFETs for ultrafast memory applications. These results establish AOS FEFETs as a compelling candidate for high-density embedded memory applications for last-level cache (LLC) (L4) in advanced CMOS technology nodes.

1-V ferroelectric field-effect transistor (FEFET)↗