Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “structural loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Mid-frequency Band Dynamics of Large Space Structures

High and low intensity dynamic environments experienced by a spacecraft during launch and on-orbit operations, respectively, induce structural loads and motions, which are difficult to reliably predict. Structural dynamics in low- and mid-frequency bands are sensitive to component interface uncertainty and non-linearity as evidenced in laboratory testing and flight operations. Analytical tools for prediction of linear system response are not necessarily adequate for reliable prediction of mid-frequency band dynamics and analysis of measured laboratory and flight data. A new MATLAB toolbox, designed to address the key challenges of mid-frequency band dynamics, is introduced in this paper. Finite-element models of major subassemblies are defined following rational frequency-wavelength guidelines. For computational efficiency, these subassemblies are described as linear, component mode models. The complete structural system model is composed of component mode subassemblies and linear or non-linear joint descriptions. Computation and display of structural dynamic responses are accomplished employing well-established, stable numerical methods, modern signal processing procedures and descriptive graphical tools. Parametric sensitivity and Monte-Carlo based system identification tools are used to reconcile models with experimental data and investigate the effects of uncertainties. Models and dynamic responses are exported for employment in applications, such as detailed structural integrity and mechanical-optical-control performance analyses.

dynamics↗

Structural and aerodynamic loads and performance measurements of an SA349/2 helicopter with an advanced geometry rotor

A flight test program was conducted to obtain data from an upgraded Gazelle helicopter with an advanced geometry, three bladed rotor. Data were acquired on upper and lower surface chordwise blade pressure, blade bending and torsion moments, and fuselage structural loads. Results are presented from 16 individual flight conditions, including level flights ranging from 10 to 77 m/sec at 50 to 3000 m altitude, turning flights up to 2.0 g, and autorotation. Rotor aerodynamic data include information from 51 pressure transducers distributed chordwise at 75, 88, and 97% radial stations. Individual tranducer pressure coefficients and airfoil section lift and pitching moment coefficients are presented, as are steady state flight condition parameters and time dependence rotor loads. All dynamic data are presented as harmonic analysis coefficients.

Heffernan, Ruth M.↗

Forward Skirt Structural Testing on the Space Launch System (SLS) Program

Structural testing was performed to evaluate heritage forward skirts from the Space Shuttle program for use on the Space Launch System (SLS) program. One forward skirt is located in each solid rocket booster. Heritage forward skirts are aluminum 2219 welded structures. Loads are applied at the forward skirt thrust post and ball assembly. Testing was needed because SLS ascent loads are roughly 40% higher than Space Shuttle loads. Testing objectives were to determine margins of safety, demonstrate reliability, and validate analytical models. Two forward skirts were structurally tested using the test configuration. The test stand applied loads to the thrust post. Four hydraulic actuators were used to apply axial load and two hydraulic actuators were used to apply radial and tangential loads. The first test was referred to as FSTA-1 (Forward Skirt Structural Test Article) and was performed in April/May 2014. The purpose of FSTA-1 was to verify the ultimate capability of the forward skirt subjected to ascent ultimate loads. Testing consisted of two liftoff load cases taken to 100% limit load followed by an ascent load case taken to 110% limit load. The forward skirt was unloaded to no load after each test case. Lastly, the forward skirt was tested to 140% limit and then to failure using the ascent loads. The second test was referred to as FSTA-2 and performed in July/August of 2014. The purpose of FSTA-2 was to verify the ultimate capability of the forward skirt subjected to liftoff ultimate loads. Testing consisted of six liftoff load cases taken to 100% limit load followed by the six liftoff cases taken to 140% limit load. Two ascent load cases were then tested to 100% limit load. The forward skirt was unloaded to no load after each test case. Lastly, the forward skirt was tested to 140% limit and then to failure using the ascent loads. The forward skirts on FSTA-1 and FSTA-2 successfully carried all applied liftoff and ascent load cases. Both FSTA-1 and FSTA-2 were tested to failure by increasing the ascent loads. Failure occurred in the forward skirt thrust post radius. The forward skirts on FSTA-1 and FSTA-2 had nearly identical failure modes. FSTA-1 failed at 1.72 times limit load and FSTA-2 failed at 1.62 times limit load. This difference is primarily attributed to variation in material properties in the thrust post region. Test data were obtained from strain gages, deflection gages, ARAMIS digital strain measurement, acoustic emissions, and high-speed video. Strain gage data and ARAMIS strain were compared to finite element (FE) analysis predictions. Both the forward skirt and tooling were modeled. This allows the analysis to simulate the loading as close as possible to actual test configuration. FSTA-1 and FSTA-2 were instrumented with over 200 strain gages to ensure all possible failure modes could be captured. However, it turned out that three gages provided critical strain data. One was located in the post bore and two on the post radius. More gages were not specified due to space limitations and the desire to not interfere with the use of the ARAMIS system on the post radius. Measured strains were compared to analysis results for the load cycle to failure. Note that FSTA-1 gages were lost before failure was reached. FSTA-2 gages made it to the failure load but one of the radius gages was lost before testing began. This gage was not replaced because of the time and cost associated with disassembly of the test structure. Correlation to analysis was excellent for FSTA-1. FSTA-2 was not quite as good because there was more residual strain from previous load cycles. FSTA-2 was loaded and unloaded with 12 liftoff cases and two ascent cases before taking the skirt to failure. FSTA-1 only had two liftoff cases and one ascent case before taking the skirt to failure. The ARAMIS system was used to determine strain at the post radius by processing digital images of a speckled paint pattern. Digital cameras recorded images of the speckled paint pattern. ARAMIS strain results for FSTA-2 just prior to failure. Note a high strain location develops near the left side. This high strain compares well to analysis prediction for both FSTA-1 and FSTA-2. The strain at this location was also plotted versus limit load. Both FSTA-1 and FSTA-2 had excellent correlation between ARAMIS and analysis strains. Acoustic emission (AE) sensors were used to monitor for damage formation that may occur during testing (e.g., crack formation and growth or propagation). AE was very important because after disassembly of FSTA-1, a crack was observed in the ball fitting radius. The ball fitting did not crack on FSTA-2. AE data was used to reconstruct when the crack occurred. The AE energy versus time plot for FSTA. The energy increased considerably at 850 seconds (152% limit load), indicating a crack could have formed at this point. The only visual evidence found that could have corresponded to this was the crack that initiated in the ball fitting. The cracks in the forward skirt aluminum structures would likely have been lower energy due to a lower modulus and all that were found after failure correlated to occurring after the initial crack in the post radius. This was verified by high-speed cameras used to record the failure.

Lohrer, J. D.↗

Assessment of Wind Parameter Sensitivity on Extreme and Fatigue Wind Turbine Loads

Wind turbines are designed using a set of simulations to ascertain the structural loads that the turbine could encounter. While mean hub-height wind speed is considered to vary, other wind parameters such as turbulence spectra, sheer, veer, spatial coherence, and component correlation are fixed or conditional values that, in reality, could have different characteristics at different sites and have a significant effect on the resulting loads. This paper therefore seeks to assess the sensitivity of different wind parameters on the resulting ultimate and fatigue loads on the turbine during normal operational conditions. Eighteen different wind parameters are screened using an Elementary Effects approach with radial points. As expected, the results show a high sensitivity of the loads to the turbulence standard deviation in the primary wind direction, but the sensitivity to wind shear is often much greater. To a lesser extent, other wind parameters that drive loads include the coherence in the primary wind direction and veer.

17 WIND ENERGY↗

Vibration Testing of Electrical Cables to Quantify Loads at Tie-Down Locations

The standard method for defining static equivalent structural load factors for components is based on Mile s equation. Unless test data is available, 5% critical damping is assumed for all components when calculating loads. Application of this method to electrical cable tie-down hardware often results in high loads, which often exceed the capability of typical tie-down options such as cable ties and P-clamps. Random vibration testing of electrical cables was used to better understand the factors that influence component loads: natural frequency, damping, and mass participation. An initial round of vibration testing successfully identified variables of interest, checked out the test fixture and instrumentation, and provided justification for removing some conservatism in the standard method. Additional testing is planned that will include a larger range of cable sizes for the most significant contributors to load as variables to further refine loads at cable tie-down points. Completed testing has provided justification to reduce loads at cable tie-downs by 45% with additional refinement based on measured cable natural frequencies.

Dutson, Joseph D.↗

Strain Gage Load Calibration of the Wing Interface Fittings for the Adaptive Compliant Trailing Edge Flap Flight Test

This is the presentation to follow conference paper of the same name. The adaptive compliant trailing edge (ACTE) flap experiment safety of flight requires that the flap to wing interface loads be sensed and monitored in real time to ensure that the wing structural load limits are not exceeded. This paper discusses the strain gage load calibration testing and load equation derivation methodology for the ACTE interface fittings. Both the left and right wing flap interfaces will be monitored and each contains four uniquely designed and instrumented flap interface fittings. The interface hardware design and instrumentation layout are discussed. Twenty one applied test load cases were developed using the predicted in-flight loads for the ACTE experiment.

strain gage calibration↗

Materials constitutive models for nonlinear analysis of thermally cycled structures

Effects of inelastic materials models on computed stress-strain solutions for thermally loaded structures were studied by performing nonlinear (elastoplastic creep) and elastic structural analyses on a prismatic, double edge wedge specimen of IN 100 alloy that was subjected to thermal cycling in fluidized beds. Four incremental plasticity creep models (isotropic, kinematic, combined isotropic kinematic, and combined plus transient creep) were exercised for the problem by using the MARC nonlinear, finite element computer program. Maximum total strain ranges computed from the elastic and nonlinear analyses agreed within 5 percent. Mean cyclic stresses, inelastic strain ranges, and inelastic work were significantly affected by the choice of inelastic constitutive model. The computing time per cycle for the nonlinear analyses was more than five times that required for the elastic analysis.

Kaufman, A.↗

Assessment of Wind Parameter Sensitivity on Ultimate and Fatigue Wind Turbine Loads: Preprint

Wind turbines are designed using a set of simulations to ascertain the structural loads that the turbine could encounter. While mean hub-height wind speed is considered to vary, other wind parameters such as turbulence spectra, sheer, veer, spatial coherence, and component correlation are fixed or conditional values that, in reality, could have different characteristics at different sites and have a significant effect on the resulting loads. This paper therefore seeks to assess the sensitivity of different wind parameters on the resulting ultimate and fatigue loads on the turbine during normal operational conditions. Eighteen different wind parameters are screened using an Elementary Effects approach with radial points. As expected, the results show a high sensitivity of the loads to the turbulence standard deviation in the primary wind direction, but the sensitivity to wind shear is often much greater. To a lesser extent, other wind parameters that drive loads include the coherence in the primary wind direction and veer.

17 WIND ENERGY↗

Analyses of composite fuselage structure under various loading conditions

With the characteristics of high strength/weight and stiffness/weight ratios in advanced composite materials, composite plate structures have been successfully applied to secondary load-carrying structural components in the aerospace industry for the past two decades. Recently, filament wound composite shells are being considered for design of primary fuselage structures. To implement the design the structural response under various loading conditions needs to be predicted accurately. Therefore, it is essential to establish a rigorous analytical solution in the area of composite laminated shells. A closed form solution is presented that predicts the response of a composite shell subjected to internal pressure, axial tension, bending, and torsion. The material of the shell is assumed to be general cylindrically anisotropic. Based on the theory of cylindrical anisotropic elasticity coupled partial differential governing equations are developed using Lehknitskii's stress function approach. The general expressions for the stresses and displacements in the composite cylinders under these loading conditions is discussed. Three examples (45) off-axis unidirectional, (45/45) unsymmetric, and (45/45)(sub s) symmetric angle-ply fiber-reinforced laminated shells are shown to illustrate the effect of radius-to-thickness ratios, coupling, and stacking sequence.

Yuan, Fuh-Gwo↗

International Space Station 2A Array Modal Analysis

On December 9th 2009, the International Space Station (ISS) 2A solar array mast experienced prolonged longeron shadowing during a Soyuz undocking. Analytical reconstruction of induced thermal and dynamic structural loads showed an exceedance of the mast buckling limit. Possible structural damage to the solar array mast could have occurred during this event. A Low fidelity video survey of the 2A mast showed no obvious damage of the mast longerons or battens. The decision was made to conduct an on-orbit dynamic test of the 2A array on December 18th, 2009. The test included thruster pluming on the array while photogrammetry data was recorded. The test was similar to other Dedicated Thruster Firings (DTFs) that were performed to measure structural frequency and damping of a solar array. Results of the DTF indicated lower frequency mast modes than model predictions, thus leading to speculation of mast damage. A detailed nonlinear analysis was performed on the 2A array model to assess possible solutions to modal differences. The setup of the parametric nonlinear trade study included the use of a detailed array model and the reduced mass and stiffness matrices of the entire ISS being applied to the array interface. The study revealed that the array attachment structure is nonlinear and thus was the source of error in the model prediction of mast modes. In addition, a detailed study was performed to determine mast mode sensitivity to mast longeron damage. This sensitivity study was performed to assess if the ISS program has sufficient instrumentation for mast damage detection.

Laible, Michael↗

High Energy Density and Stable Three-Dimensionally Structured Se-Loaded Bicontinuous Porous Carbon Battery Electrodes

Here, 3D structured Se-loaded bicontinuous porous carbon (BPC) electrodes were fabricated through colloidal templating of BPC followed by pulsed-voltage Se electrodeposition. The resultant electrodes were found to deliver a specific capacity of 665 mA h g -1 at a rate of 0.1 C, near the theoretical value for Se. When a vinylene carbonate containing electrolyte was utilized, the capacity fade over 500 cycles at 1 C rate was as small as a few percent. Impedance measurements and physical characterization of cycled electrodes indicated the exceptionally stable cycling performance was possibly due to vinylene carbonate resulting in formation of a stable SEI during cycling. Along with cycling stability, the rate performance of the 3D Se/BPC electrodes was also good. Due to the bicontinuous structure of carbonaceous current collector at rates as high as 5 C, the deliverable capacity was about 300 mA h g -1 .

25 ENERGY STORAGE↗

An optimality criterion for sizing members of heated structures with temperature constraints

A thermal optimality criterion is presented for sizing members of heated structures with multiple temperature constraints. The optimality criterion is similar to an existing optimality criterion for design of mechanically loaded structures with displacement constraints. Effectiveness of the thermal optimality criterion is assessed by applying it to one- and two-dimensional thermal problems where temperatures can be controlled by varying the material distribution in the structure. Results obtained from the optimality criterion agree within 2 percent with results from a closed-form solution and with results from a mathematical programming technique. The thermal optimality criterion augments existing optimality criteria for strength and stiffness related constraints and offers the possibility of extension of optimality techniques to sizing structures with combined thermal and mechanical loading.

Rao, G. V.↗

Robust multi‐loop control of a floating wind turbine

Abstract A principal challenge facing the control of floating offshore wind turbines (FOWTs) is the problem of instability, or “negative damping,” when using blade pitch feedback to control generator speed. This closed‐loop instability can be attributed to non‐minimum phase zeros in the transfer function from blade pitch to generator speed. Standard approaches to improving stability and performance include robust tuning of control gains and introducing multiple feedback loops to respond to platform motion. Combining these approaches is nontrivial because multiple control loops complicate the impact of coupling in the system dynamics. The single‐loop approach to analyzing stability robustness neglects inter‐loop coupling, while a simplistic multi‐loop approach is highly sensitive to dimensional scaling and overestimates the robustness of the single‐loop controller. This work proposes a sensitivity representation that separates some of the natural FOWT dynamic coupling into a parallel feedback loop in the sensitivity function loop to address both of these concerns. The modified robustness measure is used with a simplified linear FOWT model to optimize scheduled multi‐loop control parameters in an automated tuning procedure. This controller is implemented for the 10‐MW Ultraflexible Smart FLoating Offshore Wind Turbine (USFLOWT) and compared against conventional single‐ and multi‐loop controllers tuned using frequency‐domain analysis and high‐fidelity OpenFAST simulations. The multi‐loop robust controller shows the highest overall performance in generator speed regulation and tower load reduction, though consideration of power quality, actuator usage, and other structural loading leads to additional trade‐offs.

Stockhouse, David↗

Engineering analysis division internal note. OFT-1 margin assessment

The results are documented of an analysis conducted to determine space shuttle vehicle (SSV) subsystem margins for the reference flight profile for the first orbital flight test (OFT-1). In general, the results show increased margins for the OFT-1 indicators when compared to Mission 3A resutls. The inclusion of element and wing aerodynamic variations on OFT-1, in combination with winds and systems dispersions, resulted in the forward Z (FTO1) attach load indicator exceeding specified limits. The inboard and outboard elevon hinge moment margins (9 percent and 3 percent, respectively) on OFT-1 reflect values consistent with the load relief requirements dictated by elevon hinge moment variations. All other structural load indicators for OFT-1 had margins in excess of 10 percent. The SSV first stage stagnation heating indicators for OFT-1 were about 45 percent less than for Mission 3A. The hydraulic systems demands for both missions were essentially the same. The results also show OFT-1 performance requirements from the consideration of winds and dispersions to be approximately 3,300 lbs greater than Mission 3A.

Austin, L. D., Jr.↗

Device for Temporal Measurement of Loads in Parachute Suspension Systems

In order to understand the distribution of loads in parachutes, the NASA Low Density Supersonic Decelerators (LDSD) project developed a wireless instrument to measure loads in the parachute suspension lines. The load cells are titanium links that are connected in the primary structural load path of the parachute system. Strain gages measure the elongation of the links and an onboard data acquisition system records the data to ash memory. The load cells have onboard power, and include a radio transceiver that is used to receive timing information. The load cells are designed to be interfaced with cordage, packed in a parachute bag, and deployed with a standard parachute deployment. The devices are triggered passively during the deployment of the parachute. Prototype devices with a mass of 100 grams and a load capability of 16,000 lbs were built as a proof of concept.

Brandeau, Erich J.↗