Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “strain gage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

High-temperature Strain Sensor and Mounting Development

This report describes Government Work Package Task 29 (GWP29), whose purpose was to develop advanced strain gage technology in support of the National Aerospace Plane (NASP) Program. The focus was on advanced resistance strain gages with a temperature range from room temperature to 2000 F (1095 C) and on methods for reliably attaching these gages to the various materials anticipated for use in the NASP program. Because the NASP program required first-cycle data, the installed gages were not prestabilized or heat treated on the test coupons before first-cycle data were recorded. NASA Lewis Research Center, the lead center for GWP29, continued its development of the palladium-chromium gage; NASA Langley Research Center investigated a new concept gage using Kanthal A1; and the NASA Dryden Flight Research Center chose the well-known BCL-3 iron-chromium-aluminum gage. Each center then tested all three gages. The parameters investigated were apparent strain, drift strain, and gage factor as a function of temperature, plus gage size and survival rate over the test period. Although a significant effort was made to minimize the differences in test equipment between the three test sites (e.g., the same hardware and software were used for final data processing), the center employed different data acquisition systems and furnace configurations so that some inherent differences may be evident in the final results.

Williams, W. Dan↗

Simultaneous measurement of temperature and strain using four connecting wires

This paper describes a new signal-conditioning technique for measuring strain and temperature which uses fewer connecting wires than conventional techniques. Simultaneous measurement of temperature and strain has been achieved by using thermocouple wire to connect strain gages to signal conditioning. This signal conditioning uses a new method for demultiplexing sampled analog signals and the Anderson current loop circuit. Theory is presented along with data to confirm that strain gage resistance change is sensed without appreciable error because of thermoelectric effects. Furthermore, temperature is sensed without appreciable error because of voltage drops caused by strain gage excitation current flowing through the gage resistance.

Parker, Allen R., Jr.↗

Extreme Wind Velocity Measurement System

A wind velocity measurement system employs two different principles of physics to measure wind speed: (1) the aerodynamic force imparted to a low profile, rigidly mounted cylindrical rod, and (2) the vibrating frequency of the rod as vortices are shed from the rod's cylindrical surface. A set of strain gages is used as a common sensor for both measurements, and these provide force measurements imparted by the wind on the rod. The signals generated by the strain gages are fed to processing circuitry that calculates the wind speed and direction from the signals. The force measurement is proportional to the square of the wind speed. Since it is a vector quantity, it can also be used to derive wind direction. The vortex shedding frequency is a scalar quantity and is linearly proportional to wind speed. This frequency can be calculated by analyzing the force measurements generated by the strain gages over time. Both of the wind velocity calculations can be advantageously used by the processing circuitry to generate an accurate wind velocity reading.

Jan A Zysko↗

In-flight investigation of shuttle tile pressure orifice installations

To determine shuttle orbiter wing loads during ascent, wing load instrumentation was added to Columbia (OV-102). This instrumentation included strain gages and pressure orifices on the wing. The loads derived from wing pressure measurements taken during STS 61-C did not agree with those derived from strain gage measurements or with the loads predicted from the aerodynamic database. Anomalies in the surface immediately surrounding the pressure orifices in the thermal protection system (TPS) tiles were one possible cause of errors in the loads derived from wing pressure measurements. These surface anomalies were caused by a ceramic filler material which was installed around the pressure tubing. The filler material allowed slight movement of the TPS tile and pressure tube as the airframe flexed and bent under aerodynamic loads during ascent and descent. Postflight inspection revealed that this filler material had protruded from or receeded beneath the surface, causing the orifice to lose its flushness. Flight tests were conducted at NASA Ames Research Center Dryden Flight Research Facility to determine the effects of any anomaly in surface flushness of the orifice installation on the measured pressures at Mach numbers between 0.6 and 1.4. An F-104 aircraft with a flight test fixture mounted beneath the fuselage was used for these flights. Surface flushness anomalies typical of those on the orbiter after flight (STA 61-C) were tested. Also, cases with excessive protrusion and recession of the filler material were tested. This report shows that the anomalies in STS 61-C orifice installations adversely affected the pressure measurements. But the magnitude of the affect was not great enough to account for the discrepancies with the strain gage measurements and the aerodynamic predictions.

Moes, Timothy R.↗

Vibration Survey of Blades in 19XB Axial-Flow Compressor: Preliminary Engine Investigation - 3

Strain gages were used to measure blade vibrations possibly causing failure in the 10-stage compressor of the 19XB jet-propulsion engine. The seventh and tenth stages were of great concern as a result of failures experienced by the manufacturer. Strain-gage records were obtained from all stages during acceleration, deceleration, and constant speed runs. Curves are presented herein showing the maximum allowable vibratory stress for a given speed, the change of the damping coefficient with the mounting of a strain gage at the base of the blade, the effect of rotor speed, on blade natural frequency, and the effect of the order of first bending-mode vibration on stress. It was found that for all stages the lower the order of vibration the higher the stress but no destructive vibrations were detected.

Meyer, Andre J., Jr.↗

A comparative evaluation of in-plane shear test methods for laminated graphite-epoxy composites

The objectives were to evaluate popular shear test methods for various forms of graphite-epoxy composite materials and to determine the shear response of graphite-epoxy composites with various forms of fiber architecture. Numerical and full-field experimental stress analyses were performed on four shear test configurations for unidirectional and bidirectional graphite-epoxy laminates to assess the uniformity and purity of the shear stress (strain) fields produced in the specimen test section and to determine the material in-plane shear modulus and shear response. The test methods were the 10 deg off-axis, the +/- 45 deg tension, the Iosipescu V-notch, and a compact U-notch specimen. Specimens were prepared from AS4/3501-6 graphite-epoxy panels, instrumented with conventional strain gage rosettes and with a cross-line moire grating, and loaded in a convenient testing machine. The shear responses obtained for each test method and the two methods of specimen instrumentation were compared. In a second phase of the program the shear responses obtained from Iosipescu V-notch beam specimens were determined for woven fabric geometries of different weave and fiber architectures. Again the responses of specimens obtained from strain gage rosettes and moire interferometry were compared. Additional experiments were performed on a bidirectional cruciform specimen which was also instrumented with strain gages and a moire grating.

Morton, John↗

Verification and application of the Iosipescu shear test method

Finite element models were used to study the effects of notch angle variations on the stress state within an Iosipescu shear test speciment. These analytical results were also studied to determine the feasibility of using strain gage rosettes and a modified extensometer to measure shear strains in this test specimen. Analytical results indicate that notch angle variations produced only small differences in simulated shear properties. Both strain gage rosettes and the modified extensometer were shown to be feasible shear strain transducers for the test method. The Iosipoescu shear test fixture was redesigned to incorporate several improvements. These improvements include accommodation of a 50 percent larger specimen for easier measurement of shear train, a clamping mechanism to relax strict tolerances on specimen width, and a self contained alignment tool for use during specimen installation. A set of in-plane and interlaminar shear properties were measured for three graphite fabric/epoxy composites of T300/934 composite material. The three weave patterns were Oxford, 5-harness satin, and 8-harness satin.

Walrath, D. E.↗

A computer program for plotting stress-strain data from compression, tension, and torsion tests of materials

A computer program for plotting stress-strain curves obtained from compression and tension tests on rectangular (flat) specimens and circular-cross-section specimens (rods and tubes) and both stress-strain and torque-twist curves obtained from torsion tests on tubes is presented in detail. The program is written in FORTRAN 4 language for the Control Data 6000 series digital computer with the SCOPE 3.0 operating system and requires approximately 110000 octal locations of core storage. The program has the capability of plotting individual strain-gage outputs and/or the average output of several strain gages and the capability of computing the slope of a straight line which provides a least-squares fit to a specified section of the plotted curve. In addition, the program can compute the slope of the stress-strain curve at any point along the curve. The computer program input and output for three sample problems are presented.

Greenbaum, A.↗

An experimental investigation of Iosipescu specimen for composite materials

A detailed experimental evaluation of the Iosipescu specimen tested in the modified Wyoming fixture is presented. Moire interferometry is employed to determine the deformation of unidirectional and cross-ply graphite-epoxy specimens. The results of the moire experiments are compared to those from the traditional strain-gage method. It is shown that the strain-gage readings from one surface of a specimen together with corresponding data from moire interferometry on the opposite face documented an extreme sensitivity of some fiber orientations to twisting. A localized hybrid analysis is introduced to perform efficient reduction of moire data, producing whole-field strain distributions in the specimen test sections.

Ho, H.↗

Evaluation of the Hinge Moment and Normal Force Aerodynamic Loads from a Seamless Adaptive Compliant Trailing Edge Flap in Flight

A seamless adaptive compliant trailing edge (ACTE) flap was demonstrated in flight on a Gulfstream III aircraft at the NASA Armstrong Flight Research Center. The trailing edge flap was deflected between minus 2 deg up and plus 30 deg down in flight. The safety-of-flight parameters for the ACTE flap experiment require that flap-to-wing interface loads be sensed and monitored in real time to ensure that the structural load limits of the wing are not exceeded. The attachment fittings connecting the flap to the aircraft wing rear spar were instrumented with strain gages and calibrated using known loads for measuring hinge moment and normal force loads in flight. The safety-of-flight parameters for the ACTE flap experiment require that flap-to-wing interface loads be sensed and monitored in real time to ensure that the structural load limits of the wing are not exceeded. The attachment fittings connecting the flap to the aircraft wing rear spar were instrumented with strain gages and calibrated using known loads for measuring hinge moment and normal force loads in flight. The interface hardware instrumentation layout and load calibration are discussed. Twenty-one applied calibration test load cases were developed for each individual fitting. The 2-sigma residual errors for the hinge moment was calculated to be 2.4 percent, and for normal force was calculated to be 7.3 percent. The hinge moment and normal force generated by the ACTE flap with a hinge point located at 26-percent wing chord were measured during steady state and symmetric pitch maneuvers. The loads predicted from analysis were compared to the loads observed in flight. The hinge moment loads showed good agreement with the flight loads while the normal force loads calculated from analysis were over-predicted by approximately 20 percent. Normal force and hinge moment loads calculated from the pressure sensors located on the ACTE showed good agreement with the loads calculated from the installed strain gages.

Hinge Moment Loads↗

Damage Tolerance Testing of a NASA TransHab Derivative Woven Inflatable Module

Current options for Lunar habitat architecture include inflatable habitats and airlocks. Inflatable structures can have mass and volume advantages over conventional structures. Inflatable structures are perceived to carry additional risk because they are at a lower Technical Readiness Level (TRL) than conventional metallic structures. One of the risks associated with inflatable structures is understanding the tolerance to component damage and the resulting behavior of the system after the damage is introduced. The Damage Tolerance Test (DTT) is designed to study the structural integrity of an expandable structure during and subsequent to induced damage. The TransHab Project developed an experimental inflatable module developed at Johnson Space Center in the 1990's. The TransHab design was originally envisioned for use in Mars Transits but was also studied as a potential habitat for the International Space Station (ISS). The design of the TransHab module was based on a woven design using an Aramid fabric. Testing of this design demonstrated a high level of predictability and repeatability and good correlation with analytical predictions of stresses and deflections. Based on JSC's experience with the design and analysis of woven inflatable structures, the Damage Tolerance Test article was designed and fabricated using a woven design. The Damage Tolerance Test Article consists of a load bearing restraint layer, a bladder or gas barrier, and a structural metallic core. The test article restraint layer is fabricated from one inch wide Kevlar webbing that is woven in a basket weave pattern. Underneath the structural restraint layer is the bladder or gas barrier. For this test the bladder was required to maintain pressure for testing only and was not representative of a flight design. The bladder and structural restraint layer attach to the structural core of the module at steel bulkheads at each end. The two bulkheads are separated by a 10 foot center tube which provides the structural support for the module when in a non-inflated state as well as resists a portion of the axial load when pressurized. The longitudinal members of the structural restraint layer are attached to the bulkheads using a series of clevises that are bolted to the bulkheads. Strain gages are placed on the clevises that can measure change in load when the structural restraint is inflated. The test module is 88 inches in diameter and 120 inches in height. The objectives of the DTT are to (1) verify the structural integrity of the assembled and pressurized structure when a section of the structural restraint layer is cut by a foreign object, and (2) verify the load distribution of the structural restraint layer during pressurization, before and after the structural restraint layer is severed. For this test, a longitudinal structural restraint strap will be severed using a linear shape charge. The linear shape charge was designed specifically for this application to cut only a single longitudinal strap, while not damaging the bladder. An array of strain gages were located at the bulkhead mounted clevises where the longitudinal restraint layer straps are attached. The DTT article was inflated to 45 psig, 25% of the ultimate design pressure, and one of the one-inch wide longitudinal structural members was severed. Strain gage measurements of loading in an array of longitudinal straps were taken throughout pressurization of the module to 45 psig, before firing of the linear shape charge, and after firing of the shape charge and separation of the strap. During testing not only were the original objectives met but better than expected results occurred. This paper will discuss space inflatable structures, damage tolerance analysis, test results, and applicability to the Lunar architecture.

Edgecombe, John↗

Wind tunnel balance

A flow-through balance is provided which includes a non-metric portion and a metric portion which form a fluid-conducting passage in fluid communication with an internal bore in the sting. The non-metric and metric portions of the balance are integrally connected together by a plurality of flexure beams such that the non-metric portion, the metric portion and the flexure beams form a one-piece construction which eliminates mechanical hysteresis between the non-metric and the metric portion. The system includes structures for preventing the effects of temperature, pressure and pressurized fluid from producing asymmetric loads on the flexure beams. A temperature sensor and a pressure sensor are located within the fluid-conducting passage of the balance. The system includes a longitudinal bellows member connected at two ends to one of the non-metric portion and the metric portion and at an intermediate portion thereof to the other of (1) and (2). A plurality of strain gages are mounted on the flexure beams to measure strain forces on the flexure beams. The flexure beams are disposed so as to enable symmetric forces on the flexure beams to cancel out so that only asymmetric forces are measured as deviations by the strain gages.

Horne, Warren L.↗

Regression Analysis and Calibration Recommendations for the Characterization of Balance Temperature Effects

Analysis and use of temperature-dependent wind tunnel strain-gage balance calibration data are discussed in the paper. First, three different methods are presented and compared that may be used to process temperature-dependent strain-gage balance data. The first method uses an extended set of independent variables in order to process the data and predict balance loads. The second method applies an extended load iteration equation during the analysis of balance calibration data. The third method uses temperature-dependent sensitivities for the data analysis. Physical interpretations of the most important temperature-dependent regression model terms are provided that relate temperature compensation imperfections and the temperature-dependent nature of the gage factor to sets of regression model terms. Finally, balance calibration recommendations are listed so that temperature-dependent calibration data can be obtained and successfully processed using the reviewed analysis methods.

wind tunnel test↗

Testing of fiber composites at high strain rates

An experimental investigation was conducted to determine strain rate effects in fiber composites. Unidirectional composite specimens of boron/epoxy, graphite/epoxy, S-glass/epoxy and Kevlar/epoxy were tested at tensile strain rates of up to 27 m/m/sec. Longitudinal, transverse and in-plane shear properties, including modulus, Poisson's ratio, strength and ultimate strain, were determined by testing 0-, 90and 10-degree unidirectional coupons. Strains were measured by means of strain gages bonded on the coupons and loads were measured by means of a strain gage load cell. All specimens were loaded in an electrohydraulic loading system. The 0-degree properties which are governed by the fibers do not vary much with strain rate except for the Kevlar/epoxy material which shows an increase in both modulus and strength. The strain rate effects on 90-degree properties were small with a general trend toward higher strength with increasing strain rate. The most noticeable effect was on in-plane shear properties with shear strength values at high strain rates approximately fifteen percent higher than static values.

Daniel, I. M.↗

Rapid helium-air analyzer can measure other binary gas mixtures

Instrument comprised of an ionization pressure gage and a diaphragm pressure gage consisting of strain gages to make a four-arm bridge, and a ratiometer is constructed for analyzing gas mixtures. The ratio of the outputs of the two gages is proportional to the mixture composition.

Melfi, L. T.↗

Residual stresses in angleplied laminates and their effects on laminate behavior

Evidence of the presence of lamination residual stresses in angleplied laminates were transply cracks and warpage of unsymmetric laminates which occur prior to application of any mechanical load. Lamination residual strains were measured using the embedded strain gage technique. These strains result from the temperature differences between cure and room temperature and vary linearly within this temperature range. Lamination residual stresses were usually present in angleplied fiber composites laminates; they were also present in unidirectional hybrids and superhybrids. For specific applications, the magnitudes of lamination residual stresses were determined and evaluated relative to the anticipated applied stresses. Particular attention was given to cyclic thermal loadings in applications where the thermal cycling takes place over a wide temperature range.

Chamis, C. C.↗

Unsteady environments and responses of the shuttle combined loads orbiter test

Both separate and combined wind tunnel and vibration shaker tests were conducted on two structural panels representative of the Shuttle orbiter in the NASA LaRC 8-foot transonic pressure tunnel (TPT) to determine the effects of combined loads on the thermal protection system (TPS). The primary objective of this test was to provide a combined full-scale load environment and realistic time history of the dynamic pressures, Mach numbers (through transonic), and dynamic structural responses of these panels. The panels were selected from orbiter locations where interactive load sources such as aerodynamic shock waves, turbulent boundary layers, strut-induced vorticity, and substrate deformation combined to provide high bonding loads between the TPS and the orbiter structure. The test panels for this program were highly instrumented with static and dynamic pressure gages, accelerometers, deflectometers, strain gages, Schileren and high-speed photography, and special instrumentation necessary to determine TPS/structure interface loads and tile motions. Two test specimens of each orbiter panel were utilized. Both were high-fidelity representations of the selected orbiter location. The first panel (calibration panel) for each test was utilized to calibrate the tunnel and shaker system as well as provide a data-gathering source for applied static and dynamic loads. The second panel (test panel) for each test was subjected to flight time exposures only so that TPS characteristics as a function of flight mission exposure could be determined. These tests were the last in a series that was suce6ssfully completed and necessary to certify the TPS prior to the first launching of the Shuttle.

P. H. Schuetz↗

Residual stresses in continuous graphite fiber Al metal matrix composites

The residual stresses in graphite fiber reinforced aluminum (Gr/Al) composites with various thermal histories are measured using X-ray diffraction (XRD) methods. The XRD stress analysis is based on the determination of lattice strains by precise measurements of the interplanar spacings in different directions of the sample. The sample is a plate consisting of two-ply P 100 Gr/Al 6061 precursor wires and Al 6061 overlayers. Prior to XRD measurement, the 6061 overlayers are electrochemically removed. In order to calibrate the relationship between stress magnitude and lattice spacing shift, samples of Al 6061 are loaded at varying stress levels in a three-point bend fixture, while the stresses are simultaneously determined by XRD and surface-attached strain gages. The stresses determined by XRD closely match those determined by the strain gages. Using these calibrations, the longitudinal residual stresses of P 100 Gr/Al 6061 composites are measured for various heat treatments, and the results are presented.

Park, Hun Sub↗