Development and Analysis of Control Strategies for a 1 MW/3.2 MWh Energy Storage System at Avista Utilities

This report documents the work performed by Pacific Northwest National Laboratory (PNNL) and Washington State University (WSU) supporting an effort to develop control strategies for a 1 MW/3.2 MWh energy storage system (ESS) at Avista Utilities (Avista). The ESS project is funded though the Washington Clean Energy Fund (CEF) program administered by the Washington State Department of Commerce (DOC). A tri-party Cooperative Research and Development Agreement (CRADA), namely the CRADA 360, was created in 2015 to facilitate this work.

25 ENERGY STORAGE↗

Effects of Environmental Exposure on Barium Oxide Cathode Operation

Hollow cathode assemblies (HCA) are typically designed around a cylindrical emitter for the electron source. Barium oxide (BaO) emitters are one type of emitter commonly used, which consists of a porous tungsten matrix impregnated with a mixture of barium oxide, calcium oxide, and alumina. Barium oxide emitters are susceptible to poisoning by a variety of substances, including oxygen, water vapor, carbon dioxide, and air. Poisoning can occur both during operation and exposure during storage. Water vapor is the primary contaminant of concern with ground exposure, and has been historically controlled by appropriate storage and handling procedures. Over the past several years, NASA Glenn Research Center (GRC)has been testing BaO cathodes to observe the effects on cathode operation after extended environmental exposures

electric propulsion↗

Performance Modeling of Network-Attached Storage Device Based Hierarchical Mass Storage Systems

Network attached storage devices improve I/O performance by separating control and data paths and eliminating host intervention during the data transfer phase. Devices are attached to both a high speed network for data transfer and to a slower network for control messages. Hierarchical mass storage systems use disks to cache the most recently used files and a combination of robotic and manually mounted tapes to store the bulk of the files in the file system. This paper shows how queuing network models can be used to assess the performance of hierarchical mass storage systems that use network attached storage devices as opposed to host attached storage devices. Simulation was used to validate the model. The analytic model presented here can be used, among other things, to evaluate the protocols involved in 1/0 over network attached devices.

Menasce, Daniel A.↗

Site demonstration and performance evaluation of MPC for a large chiller plant with TES for renewable energy integration and grid decarbonization

Thermal energy storage (TES) for a cooling plant is a crucial resource for load flexibility. Traditionally, simple, heuristic control approaches, such as the storage priority control which charges TES during the nighttime and discharges during the daytime, have been widely used in practice, and shown reasonable performance in the past benefiting both the grid and the end-users such as buildings and district energy systems. However, the increasing penetration of renewables changes the situation, exposing the grid to a growing duck curve, which encourages the consumption of more energy in the daytime, and volatile renewable generation which requires dynamic planning. The growing pressure of diminishing greenhouse gas emissions also increases the complexity of cooling TES plant operations as different control strategies may apply to optimize operations for energy cost or carbon emissions. This paper presents a model predictive control (MPC), site demonstration and evaluation results of optimal operation of a chiller plant, TES and behind-meter photovoltaics for a campus-level district cooling system. The MPC was formulated as a mixed-integer linear program for better numerical and control properties. Compared with baseline rule-based controls, the MPC results show reductions of the excess PV power by around 25%, of the greenhouse gas emission by 10%, and of peak electricity demand by 10%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparing the economic performance of ice storage and batteries for buildings with on-site PV through model predictive control and optimal sizing

Integrating renewable energy and energy storage systems provides a way of operating the electrical grid system more energy efficiently and stably. Thermal storage and batteries are the most common devices for integration. However, it is not clear which integrated storage system performs better in terms of overall economics. Ice storage has low initial and maintenance costs, but there is an efficiency penalty for charging of storage and it can only shift electrical loads associated with building cooling requirements. A battery's round-trip efficiency, on the contrary, is quite consistent and batteries can be used to shift both HVAC and non-HVAC loads. However, batteries have greater initial costs and a shorter life. Finally, this research presents a tool, using model predictive control and optimal sizing, and provides a case study for comparing life-cycle economics of battery and ice storage systems for commercial buildings that have chillers for cooling and an on-site photovoltaic system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Network, system, and status software enhancements for the autonomously managed electrical power system breadboard. Volume 2: Protocol specification

This volume (2 of 4) contains the specification, structured flow charts, and code listing for the protocol. The purpose of an autonomous power system on a spacecraft is to relieve humans from having to continuously monitor and control the generation, storage, and distribution of power in the craft. This implies that algorithms will have been developed to monitor and control the power system. The power system will contain computers on which the algorithms run. There should be one control computer system that makes the high level decisions and sends commands to and receive data from the other distributed computers. This will require a communications network and an efficient protocol by which the computers will communicate. One of the major requirements on the protocol is that it be real time because of the need to control the power elements.

Mckee, James W.↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

SIMS prototype system 1 test results: Engineering analysis

The space and domestic water solar heating system designated SIMS Prototype Systems 1 was evaluated. The test system used 720 ft (gross) of Solar Energy Products Air Collectors, a Solar Control Corporation SAM 20 Air Handler with Model 75-175 control unit, a Jackson Solar Storage tank with Rho Sigma Mod 106 controller, and 20 tons of rack storage. The test data analysis performed evaluates the system performance and documents the suitability of SIMS Prototype System 1 hardware for field installation.

Source record↗

Modular Isolated Soft-Switching Medium Voltage String Inverter for Large-Scale PV Farm

This paper presents a single-stage modular isolated soft-switching medium voltage string inverter (MVSI) with tri-port configuration to interconnect PV and storage to medium voltage (MV) grid. The modular MVSI provides advanced functionalities such as energy storage elements integration without additional converters, connection to MV grid resulting in lower distribution losses in the PV farm, high-frequency galvanic isolation, independent control of PV, storage and grid power, high modularity and scalability. The topology of the MVSI, operation principle and model-predictive priority-switching (MPPS) control to achieve fast dynamic balancing across stacked modules are discussed. The independent power control is validated in PLECS simulation and the operation of stacked MVSI with MPPS control is verified through Hardware-in-the-loop (HIL) simulation. Here, the hardware prototype of 25 kVA MVSI building block is developed. 18 kW experimental results of single building block verifying tri-ports operation and 20 kW experimental results of two modules stacked operation are presented. A clean sinusoidal waveform with negligibly low THD in both tests is obtained. A low dv/dt of <; 1kV/us and soft-switching are achieved.

30 DIRECT ENERGY CONVERSION↗

Cyclic Injection Leads to Larger and More Frequent Induced Earthquakes under Volume-Controlled Conditions

As carbon storage technologies advance globally, methods to understand and mitigate induced earthquakes become increasingly important. Although the physical processes that relate increased subsurface pore pressure changes to induced earthquakes have long been known, reliable methods to forecast and control induced seismic sequences remain elusive. Suggested reservoir engineering scenarios for mitigating induced earthquakes typically involve modulation of the injection rate. Some operators have implemented periodic shutdowns (i.e., effective cycling of injection rates) to allow reservoir pressures to equilibrate (e.g., Paradox Valley) or shut-in wells after the occurrence of an event of concern (e.g., Basel, Switzerland). Other proposed scenarios include altering injection rates, actively managing pressures through coproduction of fluids, and preinjection brine extraction. Here, in this work, we use 3D physics-based earthquake simulations to understand the effects of different injection scenarios on induced earthquake rates, maximum event magnitudes, and postinjection seismicity. For comparability, the modeled injection considers the same cumulative volume over the project’s operational life but varies the schedule and rates of fluid injected. Simulation results show that cyclic injection leads to more frequent and larger events than constant injection. Furthermore, with intermittent injection scenario, a significant number of events are shown to occur during pauses in injection, and the seismicity rate remains elevated for longer into the postinjection phase compared to the constant injection scenario.

58 GEOSCIENCES↗

Off-design operation and performance of pumped thermal energy storage

In this article, we describe off-design models and control strategies for a Pumped Thermal Energy Storage (PTES) system that uses liquid thermal energy storage: specifically molten salt for hot storage and methanol for cold storage. Off-design conditions arise when load-following, or due to variations in storage tank temperatures or ambient temperatures. We propose a control strategy that uses inventory control to manage the mass flow rate in the thermodynamic cycles, which facilitates load following. We also propose a control strategy for the storage fluid mass flow rates, which are varied to ensure the molten salt is maintained at its design temperature. This maximizes efficiency and minimizes problems with salt freezing or degradation. The cold storage fluid mass flow rate is varied so that the cold tanks have the same state-of-charge as the hot tanks. This leads to variations in cold fluid temperature, but these variations are shown to be acceptably small (e.g. 7.5% increase), and this control method is shown to be simpler and more efficient than an alternative strategy where tanks become unbalanced. The ambient temperature and storage tank temperatures are moved ±50 °C from the design values and the impact on power, duration, and tank temperatures is quantified. Results demonstrate that the proposed control strategy is stable and self-correcting - that is, storage temperatures converge on stable values after two-to-three charge-discharge cycles. When inputs return to design values, the system returns to its design point after two charge-discharge cycles. We also demonstrate that inventory control enables delivery of the target power output even when off-design conditions exist that would normally reduce the power output.

25 ENERGY STORAGE↗

Heat Melt Compaction as an Effective Treatment for Eliminating Microorganisms from Solid Waste

One of the technologies being tested at Ames Research Center as part of the logistics and repurposing project is heat melt compaction (HMC) of solid waste to reduce volume, remove water and render a biologically stable and safe product. Studies at Kennedy Space Center have focused on the efficacy of the heat melt compaction process for killing microorganisms in waste and specific compacter operation protocols, i.e., time and temperature, required to achieve a sterile, stable product. The work reported here includes a controlled study to examine the survival and potential re-growth of specific microorganisms over a 6-month period of storage after heating and compaction. Before heating and compaction, ersatz solid wastes were inoculated with Bacillus amyloliquefaciens and Rhodotorula mucilaginosa, previously isolated from recovered space shuttle mission food and packaging waste. Compacted HMC tiles were sampled for microbiological analysis at time points between 0 and 180 days of storage in a controlled environment chamber. In addition, biological indicator strips containing spores of Bacillus atrophaeus and Ceo bacillus stearothermophilus were imbedded in trash to assess the efficacy of the HMC process to achieve sterilization. Analysis of several tiles compacted at 180 C for times of 40 minutes to over 2 hours detected organisms in all tile samples with the exception of one exposed to 180 C for approximately 2 hours. Neither of the inoculated organisms was recovered, and the biological indicator strips were negative for growth in all tiles indicating at least local sterilization of tile areas. The findings suggest that minimum time/temperature combination is required for complete sterilization. Microbial analysis of tiles processed at lower temperatures from 130 C-150 C at varying times will be discussed, as well as analysis of the bacteria and fungi present on the compactor hardware as a result of exposure to the waste and the surrounding environment. The two organisms inoculated into the waste were among those isolated and identified from the HMC surfaces indicating the possibility of cross contamination.

Hummerick, Mary P.↗

Heat Melt Compaction as an Effective Treatment for Eliminating Microorganisms from Solid Waste

One of the technologies being tested at Ames Research Center as part of the logistics and repurposing project is heat melt compaction (HMC) of solid waste to reduce volume, remove water and render a biologically stable and safe product. Studies at Kennedy Space Center have focused on the efficacy of the heat melt compaction process for killing microorganisms in waste and specific compacter operation protocols, i.e., time and temperature required to achieve a sterile, stable product. The work. reported here includes a controlled study to examine the survival and potential re-growth of specific microorganisms over a 6-month period of storage after heating and compaction. Before heating and compaction, ersatz solid wastes were inoculated with Bacillus amyloliquefaciens and Rhodotorula mucilaginosa, previously isolated from recovered space shuttle mission food and packaging waste. Compacted HMC tiles were sampled for microbiological analysis at time points between 0 and 180 days of storage in a controlled environment chamber. In addition, biological indicator strips containing spores of Bacillus atrophaeus and Geobacillus stearothermophilus were imbedded in trash to assess the efficacy of the HMC process to achieve sterilization. Analysis of several tiles compacted at 180deg C for times of 40 minutes to over 2 hours detected organisms in all tile samples with the exception of one exposed to 180deg C for approximately 2 hours. Neither of the inoculated organisms was recovered, and the biological indicator strips were negative for growth in all tiles indicating at least local sterilization of tile areas. The findings suggest that minimum time/temperature combination is required for complete sterilization. Microbial analysis of tiles processed at lower temperatures from 130deg C-150deg C at varying times will be discussed, as well as analysis of the bacteria and fungi present on the compactor hardware as a result of exposure to the waste and the surrounding environment. The two organisms inoculated into the waste were among those isolated and identified from the HMC surfaces indicating the possibility of cross contamination.

Hummerick, Mary P.↗

Using Controlled-Source Electromagnetic (CSEM) for CO 2 Storage Monitoring in the North Dakota CarbonSAFE Project

Conference presentation for International Meeting for Applied Geophysics & Energy (IMAGE), September 26 – October 1, 2021, Denver, CO. Geophysical methods are key for characterizing the geologic formations to store CO 2 and monitor the injected CO 2 over time to ensure containment. In the integrated multimeasurement geophysical approach considered for this project, it is expected that the controlled-source electromagnetic (CSEM) method is a strong contributor to mapping the CO 2 movement. A feasibility study of the CSEM method, including 1D and 3D modeling and a field noise test, was conducted to determine its effectiveness in monitoring CO 2 in the Broom Creek and Deadwood Formations. The study results demonstrate that the CSEM method can be used for CO 2 storage monitoring in the study area.

20 FOSSIL-FUELED POWER PLANTS↗

Tidal energy extraction modifies tidal asymmetry and transport in a shallow, well-mixed estuary

Tidal energy extraction is increasingly being studied as a potential renewable energy resource in estuaries worldwide. Although it is understood that energy extraction via tidal stream turbines can modify currents and transport within estuaries, it is not clear how the underlying nonlinear physical mechanisms dictating tidal hydrodynamics are modulated. This research investigates the influence of a hypothetical tidal stream turbine array on barotropic tidal processes in a shallow, well-mixed system: the Piscataqua River – Great Bay (PRGB) estuary, using a numerical model. The modeled turbine farm includes 180 turbines which would extract an estimated 44.7 GWh of energy, annually. The tidal hydrodynamic model for the existing condition is validated with in-situ observations of currents and water level before analyzing tidal asymmetry and transport with and without tidal turbines. Results indicate that the tidal turbine array will decrease tidal elevation and current magnitudes system-wide, but generally reduce ebb currents and transport more than flood over most of the estuary footprint, thereby diminishing tidal asymmetry. The smaller asymmetric distortion compared to the no-turbine case is attributed to reductions in the storage volume of water over the estuary’s extensive tidal flat regions between low and high waters which decreases the associated nonlinear intertidal storage mechanism up to 25%. This leads to weakened ebb dominance over estuary sections from the mouth to mid-reaches, where depths are deep enough to keep the combined nonlinear shallow water and frictional effects from asserting control over the storage mechanism. Even in upstream shallow regions where depth-dependent friction controls asymmetry in both cases, the frictional mechanism is reduced only by 10% with turbines. Some environmental considerations of this work are discussed, with focus on sediment transport, water quality, and ecology.

16 TIDAL AND WAVE POWER↗

Time-lapse seismic data inversion for estimating reservoir parameters using deep learning

Geologic carbon sequestration involves the injection of captured carbon dioxide ([Formula: see text]) into subsurface formations for long-term storage. The movement and fate of the injected [Formula: see text] plume is of great concern to regulators because monitoring helps to identify potential leakage zones and determines the possibility of safe long-term storage. To address this concern, we design a deep-learning framework for [Formula: see text] saturation monitoring to determine the geologic controls on the storage of the injected [Formula: see text]. We use different combinations of porosities and permeabilities for a given reservoir to generate saturation and velocity models. We train the deep-learning model with a few time-lapse seismic images and their corresponding changes in saturation values for a particular [Formula: see text] injection site. The deep-learning model learns the mapping from the change in the time-lapse seismic response to the change in [Formula: see text] saturation during the training phase. We then apply the trained model to data sets comprising different time-lapse seismic image slices (corresponding to different time instances) generated using different porosity and permeability distributions that are not part of the training to estimate the [Formula: see text] saturation values along with the plume extent. Our algorithm provides a deep-learning assisted framework for the direct estimation of [Formula: see text] saturation values and plume migration in heterogeneous formations using the time-lapse seismic data. Our method improves the efficiency of time-lapse inversion by streamlining the large number of intermediate steps in the conventional time-lapse inversion workflow. This method also helps to incorporate the geologic uncertainty for a given reservoir by accounting for the statistical distribution of porosity and permeability during the training phase. Tests on different examples verify the effectiveness of our approach.

Geochemistry & Geophysics↗

Deep in the Sierra Nevada critical zone: saprock represents a large terrestrial organic carbon stock

Large uncertainty remains in the spatial distribution of deep soil organic carbon (OC) storage and how climate controls belowground OC. This research aims to quantify OC stocks, characterize soil OC age and chemical composition, and evaluate climatic impacts on OC storage from the soil surface through the deep critical zone to bedrock. These objectives were carried out at four sites along a bio-climosequence in the Sierra Nevada, California. On average, 74% of OC was stored below the A horizon, and up to 30% of OC was stored in saprock (friable weakly weathered bedrock). Radiocarbon, spectroscopic, and isotopic analyses revealed the coexistence of very old organic matter (OM) (mean radiocarbon age = 20 300 years) with relatively recent OM (mean radiocarbon age = 4800 years) and highly decomposed organic compounds with relatively less decomposed material in deep soil and saprock. This co-mingling of OM suggests OC is prone to both active cycling and long-term protection from degradation. In addition to having direct effects on OC cycling, climate indirectly controls deep OC storage through its impact on the degree of regolith weathering (e.g. thickening). Although deep OC concentrations are low relative to soil, thick saprock represents a large, previously unrealized OC pool.