Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “steam flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Eccentricity effects on leakage of a brush seal at low speeds

The effects of eccentricity on brush seal leakage at low rotational speeds were investigated. Included are the leakage results for ambient temperature air and nearly saturated streams at three different rotor eccentricities at both 0 and 400 rpm. A brush seal with a nominal bore diameter of 13.647 cm. (5.3730 in.) was used. It had a radial concentric interference of 0.071 cm (0.0028 in.) and a fence height of 0.0927 cm (0.0365 in.). There were 1060 bristles per centimeter of circumference (2690 bristles per inch of circumference). Rotor eccentricities of 0.003, 0.010, 0.038, and 0.043 cm (0.001, 0.004, 0.015, and 0.017 in.) were achieved by using bushings with different offsets. The results were compared with an annular seal model (FLOWCAL) for air and to a standard labyrinth seal model for steam. The annular seal model was also compared with a bulk flow model of a concentric brush seal in air. Large eccentricities did not damage the brush seals or their Haynes 25 bristles. However, the 304 stainless steel rotor did not show wear, indicating a harder surface is needed. Only the stream data showed hysteresis and were affected by shaft rotation. The brush seal had lower leakage rates than those predicted for comparable annular and labyrinth seals (conventional) because of the large clearances those seals require to accommodate large shaft excursions.

Schlumberger, Julie A.↗

A3 Subscale Rocket Hot Fire Testing

This paper gives a description of the methodology and results of J2-X Subscale Simulator (JSS) hot fire testing supporting the A3 Subscale Diffuser Test (SDT) project at the E3 test facility at Stennis Space Center, MS (SSC). The A3 subscale diffuser is a geometrically accurate scale model of the A3 altitude simulating rocket test facility. This paper focuses on the methods used to operate the facility and obtain the data to support the aerodynamic verification of the A3 rocket diffuser design and experimental data quantifying the heat flux throughout the facility. The JSS was operated at both 80% and 100% power levels and at gimbal angle from 0 to 7 degrees to verify the simulated altitude produced by the rocket-rocket diffuser combination. This was done with various secondary GN purge loads to quantify the pumping performance of the rocket diffuser. Also, special tests were conducted to obtain detailed heat flux measurements in the rocket diffuser at various gimbal angles and in the facility elbow where the flow turns from vertical to horizontal upstream of the 2nd stage steam ejector.

Saunders, G. P.↗

Simulation of Fluid Flow and Collection Efficiency for a SEA Inc. Multi-Element Probe and Ice Crystal Detector Using GlennICE

Numerical simulation results of fluid flow and collection efficiency of the Science Engineering Associates Inc. Multi-Element Probe (Multiwire) and Ice Crystal Detector (ICD) are presented. Fluid flow simulations were conducted using NASA's FUN3D while collection efficiency simulations were conducted using NASA's LEWICE3D software and GlennICE software. For both probes, 3D unsteady flow results were time-averaged. Simulations were computed for free steam velocities ranging from 85 to 185 m/s and freestream total pressures of 44.8 and 93.1 kPa. Collection efficiency results were computed for four spherical particle diameter sizes of 5, 20, 50, and 100 µm. GlennICE collection efficiency results for the multiwire were compared with previously published collection efficiency values calculated using LEWICE3D. Numerical collection efficiency results for the Ice Crystal Detector are presented for the first time.

aircraft, icing, Computational Fluid Dynamics↗

Fuel injection and mixing systems having piezoelectric elements and methods of using the same

A fuel injection and mixing system is provided that is suitable for use with various types of fuel reformers. Preferably, the system includes a piezoelectric injector for delivering atomized fuel, a gas swirler, such as a steam swirler and/or an air swirler, a mixing chamber and a flow mixing device. The system utilizes ultrasonic vibrations to achieve fuel atomization. The fuel injection and mixing system can be used with a variety of fuel reformers and fuel cells, such as SOFC fuel cells.

42 ENGINEERING↗

Simulations of a Helical Tube Bundle in Cross-Flow for Application to Flow-Induced Vibration

Helical tubes have been used in a number of systems, including the energy and chemical processing industries. Helical-Coil Steam Generators (HCSGs) in particular have special application in systems for which spatial constraints are important. Variants of these designs are notably included in a number of integral-vessel small modular reactor (SMR) designs which are currently in development by multiple companies. These designs typically have the primary side located within the vessel, with the secondary side flowing upward through the helical tubes. One complexity in implementing an HCSG within the reactor pressure vessel is that any potential flow-induced vibration (FIV) can impact reactor safety. In a typical power plant, heat exchanger tube failures caused by FIV can be costly, but generally do not have immediate impact on the core safety due to their relative isolation from the core area. In an integral-vessel design, a tube rupture could eject material from the secondary side into the primary flow, potentially damaging the core itself or other crucial components. Thus a higher degree of confidence in predicting and/or preventing FIV should be attained for implementing the helical tubes in these designs. A significant campaign is currently underway to address the topic of FIV in helical tube arrays. The U.S. Department of Energy, under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) initiative, has deemed this a 'high-impact problem'. This will include both experimental and computational contributions from a consortium consisting of multiple universities, industry partners, and national laboratories, including Argonne National Laboratory. The primary industrial partner is NuScale, which will see direct benefits from this initiative to the development of their SMR and its component design. The primary focus of this paper is to establish some of the computational efforts that have been made to this stage and the initial benchmarking of computational tools. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cold-Flow Testing of a Proposed Integrated Center-Body Diffuser/Steam Blocker Concept for Plum Brook Station's B-2 Test Facility

The center-body diffuser (CBD) steam blocker (SB) system is a concept that incorporates a set of secondary drive nozzles into the envelope of a CBD, such that both nozzle systems (i.e., the rocket engine and the steam blocking nozzles) utilize the same supersonic diffuser, and will operate either singularly or concurrently. In this manner, the SB performs as an exhaust system stage when the rocket engine is not operating, and virtually eliminates discharge flow on rocket engine shutdown. A 2.25-percent scale model of a proposed SB integrated into a diffuser for the Plum Brook B-2 facility was constructed and cold-flow tested for the purpose of evaluating performance characteristics of various design options. These specific design options addressed secondary drive nozzle design (method of steam injection), secondary drive nozzle location relative to CBD throat, and center-body throat length to diameter (L/D) ratios. The objective of the test program is to identify the desired configuration to carry forward should the next phase of design proceed. The tested scale model can provide data for various pressure ratios; however, its design is based on a proposed B-2 spray chamber (SC) operating pressure of 4.0 psia and a steam supply pressure of 165 psia. Evaluation of the test data acquired during these tests indicate that either the discrete axial or annular nozzle configuration integrated into a CBD, with an annular throat length of 1.5 L/D at the nominal injection position, would be suitable to carry forward from the SB's perspective. Selection between these two then becomes more a function of constructability and implementation than performance. L/D also has some flexibility, and final L/D selection can be a function of constructability issues within a limited range.

Edwards, Daryl A.↗

Orificed Flow Results for a Two-Phase Natural Circulation Loop

Researchers at University of Wisconsin - Madison have constructed a 1/4 scaled experimental facility to study the operation of a two-phase natural circulation decay heat removal system. The Reactor Cavity Cooling System (RCCS) is a decay heat removal safety system designed for high temperature generation IV reactors. The system removes decay heat by encircling the outside of the walls of the pressure/containment vessel with cooling channels. These channels are filled with either air in an open loop configuration or water in a closed loop configuration. Radiative and convective heat loads from the pressure vessel induce a buoyancy driven flow in the risers. In accident conditions, the water-based system reaches saturation and the resulting steam is vented off further removing heat until the water inventory is depleted. The water based system has been under investigation at University of Wisconsin - Madison for variations in performance under various flow restriction cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Three-Dimensional Computational Fluid Dynamics Modeling of Solid Oxide Electrolysis Cells and Stacks

A three-dimensional computational fluid dynamics (CFD) electrochemical model has been created for detailed analysis of a high-temperature electrolysis stack (solid oxide fuel cells operated as electrolyzers). Inlet and outlet plenum flow distributions are discussed. Maldistribution of plena flow show deviations in per-cell operating conditions due to non-uniformity of species concentrations. Models have also been created to simulate experimental conditions and for code validation. Comparisons between model predictions and experimental results are discussed. Mass, momentum, energy, and species conservation and transport are provided via the core features of the commercial CFD code FLUENT. A solid-oxide fuel cell (SOFC) model adds the electrochemical reactions and loss mechanisms and computation of the electric field throughout the cell. The FLUENT SOFC user-defined subroutine was modified for this work to allow for operation in the electrolysis mode. Model results provide detailed profiles of temperature, Nernst potential, operating potential, activation over-potential, anode-side gas composition, cathode-side gas composition, current density and hydrogen production over a range of stack operating conditions. Variations in flow distribution, and species concentration are discussed. End effects of flow and per-cell voltage are also considered. Predicted mean outlet hydrogen and steam concentrations vary linearly with current density, as expected. Contour plots of local electrolyte temperature, current density, and Nernst potential indicate the effects of heat transfer, reaction cooling/heating, and change in local gas composition.

08 HYDROGEN↗

Effective direct steam regeneration of bis-iminoguanidine solid sorbent used for carbon dioxide capture

A cost-effective, energy-efficient sorbent regeneration process for phase-changing guanidines used for CO 2 capture was developed based on direct-steam stripping. This approach enhances the regeneration rate, simplifies the overall CO 2 capture process, and reduces the energy cost compared to conventional conductive thermal regeneration. A direct-steam sorbent regeneration reactor was developed, demonstrating that aqueous bis(iminoguanidines) (BIG) sorbents, e.g., methylglyoxal-bis(iminoguanidine) (MGBIG) and glyoxal-bis(iminoguanidine) (GBIG), could be efficiently regenerated with up to ~ 99 % CO 2 recovery through direct-steam stripping. Using low-temperature steam at 100 °C, a 4.5 times faster regeneration rate for GBIG carbonate sorbent (e.g., 30 min for 10 g) was demonstrated compared to conductive-heating (e.g., 135 min for 10 g) at 130 °C. Additionally, fully regenerated MGBIG converts into an aqueous MGBIG solution when the steam condenses onto the sorbent surface. Condensed steam with the guanidine can be easily recycled as an aqueous solution into the gas–liquid contactor to achieve a continuous-flow CO 2 -capture process. Molecular dynamics simulation was employed to provide a better understanding of the process. Higher heat transfer rates from steam to guanidine carbonate, compared to air heating, were attributed to the vibration resonance of water molecules within MGBIG with that of vapor molecules and the effective transfer of kinetic energy from vapor to solid. Technoeconomic analysis demonstrated that direct-steam stripping significantly decreases the CO 2 capture cost by 50 % compared to traditional conductive heating methods. Further, enhanced mass transfer facilitated by low-temperature steam and subsequent condensation effectively heats up the H 2 O-containing BIG-carbonate crystals, facilitating the desorption of CO 2 from the solid crystals, thereby leading to fast, effective, and energy-efficient sorbent regeneration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exfoliation Propensity of Oxide Scale in Heat Exchangers Used for Supercritical CO2 Power Cycles

Supercritical CO2 (sCO2) Brayton cycle systems offer the possibility of improved efficiency in future fossil energy power generation plants operating at temperatures of 650 C and above. As there are few data on the oxidation/corrosion behavior of structural alloys in sCO2 at these temperatures, modeling to predict the propensity for oxide exfoliation is not well developed, thus hindering materials selection for these novel cycles. The ultimate goal of this effort is to provide needed data on scale exfoliation behavior in sCO2 for confident alloy selection. To date, a model developed by ORNL and EPRI for the exfoliation of oxide scales formed on boiler tubes in high-temperature, high-pressure steam has proven useful for managing exfoliation in conventional steam plants. A major input provided by the model is the ability to predict the likelihood of scale failure and loss based on understanding of the evolution of the oxide morphologies and the conditions that result in susceptibility to exfoliation. This paper describes initial steps taken to extend the existing model for exfoliation of steam-side oxide scales to sCO2 conditions. The main differences between high-temperature, high-pressure steam and sCO2 that impact the model involve (i) significant geometrical differences in the heat exchangers, ranging from standard pressurized tubes seen typically in steam-producing boilers to designs for sCO2 that employ variously-curved thin walls to create shaped flow paths for extended heat transfer area and small channel cross-sections to promote thermal convection and support pressure loads; (ii) changed operating characteristics with sCO2 due to the differences in physical and thermal properties compared to steam; and (iii) possible modification of the scale morphologies, hence properties that influence exfoliation behavior, due to reaction with carbon species from sCO2. The numerical simulations conducted were based on an assumed sCO2 operating schedule and several generic heat exchanger channel shapes and cross-sectional areas. Implications for the evolution of stresses in the oxide scales formed on sCO2 heat exchangers, and ensuing critical oxide thicknesses for exfoliation, were derived and compared with expectations for an equivalent conventional tubular heat exchanger in a steam cycle (for a given alloy).

Sabau, Adrian S↗

A collaborative detection approach for internal steam leakage of tyre vulcanization workshop with artificial immune algorithm

In manufacturing industry, internal leakage of steam trap usually results in great steam waste. In particular, internal steam leakage in tyre vulcanization workshop has significant influences on its production safety and energy efficiency. In practice, internal steam leakage problem often is ignored and it tends to be difficult to detect this leakage due to lack of comprehensive flow meter or method. This paper presents a collaborative detection method for this problem in tyre vulcanization workshop with artificial immune algorithm. In the method, internal leakage of steam trap is defined as nonself antigens, and steam pressure differentials between steam pipe and steam rooms (or bladders) are extracted as epitopes of antigens. Furthermore, periodic energy efficiency and steam pressure of vulcanizer as the danger signals are simultaneously detected. Energy efficiency is represented by damaged cells which will be identified firstly for locating the leaking steam straps through antibodies. Furthermore, the self-adaptive danger thresholds for energy efficiency are evaluated through a steam consumption model and the Levenberg–Marquardt back propagation algorithm. An immune-based clustering algorithm aiNet is then adopted to generate antibodies (detectors) for detection on the steam pressure of vulcanizer. Finally, a case study is implemented to validate this method, which shows that collaborative detection method allows locating the specific leaking steam trap and is a feasible tool to reduce steam waste and ensure the safety of steam supply.

42 ENGINEERING↗

Stepwise conversion of a single source precursor into crystalline AlN by transamination reaction

Ammonolysis of the monomeric, base-stabilized trisaminoalane Me{sub 3}N-Al[N(H)Dipp)]{sub 3} (Dipp=2,6-{sup i}Pr{sub 2}-C{sub 6}H{sub 3}) yielded Al-N oligomers, which were characterized in detail by solid state NMR spectroscopy ({sup 1}H, {sup 13}C, {sup 15}N, {sup 27}Al) and TGA/DTA. Pyrolysis of as-prepared oligomers at different temperatures in an argon steam yielded carbon-containing black solids, whereas pyrolysis under a steady flow of NH{sub 3} produced pure aluminum nitride (AlN). The role of the pyrolysis temperature and the influence of NH{sub 3} on the formation of crystalline materials were investigated. As-prepared AlN was characterized by solid state NMR spectroscopy ({sup 15}N, {sup 27}Al), X-ray diffraction (XRD), transmission electron microscopy (TEM) and electron energy loss spectroscopy (EELS). Theoretical calculations were performed in order to identify potential reaction intermediates. - Graphical abstract: Ammonolysis reactions of Me{sub 3}N-Al(NHDipp){sub 3} in liquid NH{sub 3} yielded Al-N oligomers, which can be transformed into nanocrystalline aluminum nitride particles under thermolysis conditions at 1000 deg. C. Theoretical calculations were performed in order to identify potential reaction intermediates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental investment of a pulse combustion steam generator and assessment of its environmental characteristics

The design of a steam generator constructed on the basis of a pulse combustion apparatus equipped with a swirl combustion chamber and an aerodynamic vale is described, and results of its experimenta; investment are presented. The quantity of nitrogen oxide emissions is estimated. A schematic arrangement for practical application of such an apparatus is proposed.

01 COAL, LIGNITE, AND PEAT↗

Thermal Energy Storage for Dispatchable Geothermal Power

Dispatchable generation refers to sources of electricity that can be turned on or off, or can adjust their power output accordingly to an order. Geothermal plants are usually used for base-load power rather than dispatchable power. Flexibility is a challenge for a geothermal plant because the heat source does not naturally respond quickly to changes in demand. The current state-of-the-art approach to address this challenge is to maintain the geothermal fluid flows at relatively steady rates while providing a bypass around the generation equipment as needed. Under part load, some of the geothermal fluid is pumped to the surface, bypasses the generation equipment, and is re-injected to the ground without extracting any useful enthalpy. This approach is robust but necessarily incurs high parasitic power draws at part load due to the constant, full-flow pumping power requirements. There are even more challenges and unknowns for steam and flash geothermal plants, which were the focus for this project. As a process improvement to this existing configuration of a dispatchable geothermal plant, we examined the use of a phase-change thermal-energy storage (TES) unit that will provide some “inertia” against temperature fluctuations. The TES phase change material (PCM) could be in the form of eutectic molten nitrate salts, organic sugar alcohols, or the like based on the required temperature. This configuration allowed the power plant to meet the ramp rate requirements while allowing the geothermal resource to drawn down at the duty-cycle-averaged extraction rate rather than the full-rated-output extraction rate. The project team performed an experimental and computational evaluation of a peak shaving technical approach that used thermal storage to switch between two nominal operating points: full rated power and 50% power. In the initial requirements definition phase, the team decided to examine the PCM/TES-enhanced geothermal plant in the context of a 40-MW two-stage flash plant operating in mid-Southern California. Steady-state process simulations were used to understand the equipment sizing and the energetics. Dynamic process simulations were used to understand the response rate of the system to changes in requested power output from the utility. The technical approach was also guided by a techno-economic analysis (TEA) and a high-level analysis of the reservoir. Recognizing that performance of the thermal storage was a key risk element, high-fidelity finite-element simulations of the PCM-TES heat exchanger were performed to better understand its performance and temporal response. These simulations were validated with a subscale PCM-TES experimental apparatus that mimicked the geometry of the full-scale system. The key outcomes of this Phase I project were that: 1) the PCM-TES heat exchanger met the target for gravimetric energy storage density, 2) the dispatchable geothermal plant met its target for response rate, 3) the peak shaving approach reduces the number of production wells and does not disturb the wellfield, and 4) the incentives for properly remunerating dispatchable operation were identified.

15 GEOTHERMAL ENERGY↗

The Northwest Geysers Enhanced Geothermal System Demonstration Project, The Geysers, California (Final Report)

An Enhanced Geothermal System (EGS) Demonstration Project was completed in the northwest portion of The Geysers geothermal field in Northern California. The goal was to demonstrate the feasibility of stimulating a deep, high temperature reservoir (HTR) with measured temperatures up to 750 °F (400 °C). We note that while some of the traditional Hot Dry Rock EGS concepts involves one or a few repeated hydraulically pressurized stimulations, our concept involves continuous injection over a periods of years at relatively low injection flows and at low pressures. Important measures of success are a sustained steam production rate and decreasing noncondensible gas (NCG) concentrations within the EGS Demonstration area. The project was completed in three phases and this Final Report characterizes the EGS reservoir and documents the successful stimulation of the HTR by the continuous injection of treated wastewater under only a gravity pressure head.

15 GEOTHERMAL ENERGY↗

Geothermal down well pumping system

A key technical problem in the exploitation of hot water geothermal energy resources is down-well pumping to inhibit mineral precipitation, improve thermal efficiency, and enhance flow. A novel approach to this problem involves the use of a small fraction of the thermal energy of the well water to boil and super-heat a clean feedwater flow in a down-hole exchanger adjacent to the pump. This steam powers a high-speed turbine-driven pump. The exhaust steam is brought to the surface through an exhaust pipe, condensed, and recirculated. A small fraction of the high-pressure clean feedwater is diverted to lubricate the turbine pump bearings and prevent leakage of brine into the turbine-pump unit. A project demonstrating the feasibility of this approach by means of both laboratory and down-well tests is discussed.

Matthews, H. B.↗

Modeling and optimization of a modified claus process as part of an integrted gasification combined cycle (IGCC) power plant with CO2 capture

The modified Claus process is one of the most common technologies for sulfur recovery from acid gas streams. Important design criteria for the Claus unit, when part of an Integrated Gasification Combined Cycle (IGCC) power plant, are the ability to destroy ammonia completely and recover sulfur thoroughly from a relatively low purity acid gas stream without sacrificing flame stability. Due to these criteria, modifications are often required to the conventional process, resulting in a modified Claus process. For the studies discussed here, these modifications include the use of a 95% pure oxygen stream as the oxidant, a split flow configuration, and the preheating of the feeds with the intermediate pressure steam generated in the waste heat boiler (WHB). In the future, for IGCC plants with CO2 capture, the Claus unit must satisfy emission standards without sacrificing the plant efficiency in the face of typical disturbances of an IGCC plant such as rapid change in the feed flowrates due to load-following and wide changes in the feed composition because of changes in the coal feed to the gasifier. The Claus unit should be adequately designed and efficiently operated to satisfy these objectives. Even though the Claus process has been commercialized for decades, most papers concerned with the modeling of the Claus process treat the key reactions as equilibrium reactions. Such models are validated by manipulating the temperature approach to equilibrium for a set of steady-state operating data, but are of limited use for dynamic studies. One of the objectives of this study is to develop a model that can be used for dynamic studies. In a Claus process, especially in the furnace and the WHB, many reactions may take place. In this work, a set of linearly independent reactions has been identified and kinetic models of the furnace flame and anoxic zones, WHB, and catalytic reactors have been developed. To facilitate the modeling of the Claus furnace, a four-stage method was devised so as to determine which set of linearly independent reactions would best describe the product distributions from available plant data. Various approaches are taken to derive the kinetic rate expressions which are either missing in the open literature or found to be inconsistent. A set of plant data is used for optimal estimation of the kinetic parameters. The final model agrees well with the published plant data. Using the developed kinetics models of the Claus reaction furnace, WHB, and catalytic stages, two optimization studies are carried out. The first study shows that there exists an optimal steam pressure generated in the WHB that balances hydrogen yield, oxygen demand, and power generation. In the second study, it is shown that an optimal H2S/SO2 ratio exists that balances single-pass conversion, hydrogen yield, oxygen demand, and power generation. In addition, an operability study has been carried out to examine the operating envelope in which both H2S/SO2 ratio and adiabatic flame temperature can be controlled in the face of disturbances typical for the operation of an IGCC power plant with CO2 capture. Impact of CO2 capture on the Claus process has also been discussed.

08 HYDROGEN↗

Thermal Propulsion Capture System Heat Exchanger Design

One of the biggest challenges of manned spaceflight beyond low earth orbit and the moon is harmful radiation that astronauts would be exposed to on their long journey to Mars and further destinations. Using nuclear energy has the potential to be a more effective means of propulsion compared to traditional chemical engines (higher specific impulse). An upper stage nuclear engine would allow astronauts to reach their destination faster and more fuel efficiently. Testing these engines poses engineering challenges due to the need to totally capture the engine exhaust. The Thermal Propulsion Capture System is a concept for cost effectively and safely testing Nuclear Thermal Engines. Nominally, hydrogen exhausted from the engine is not radioactive, but is treated as such in case of fuel element failure. The Thermal Propulsion Capture System involves injecting liquid oxygen to convert the hydrogen exhaust into steam. The steam is then cooled and condensed into liquid water to allow for storage. The Thermal Propulsion Capture System concept for ground testing of a nuclear powered engine involves capturing the engine exhaust to be cooled and condensed before being stored. The hydrogen exhaust is injected with liquid oxygen and burned to form steam. That steam must be cooled to saturation temperatures before being condensed into liquid water. A crossflow heat exchanger using water as a working fluid will be designed to accomplish this goal. Design a cross flow heat exchanger for the Thermal Propulsion Capture System testing which: Eliminates the need for water injection cooling, Cools steam from 5800 F to saturation temperature, and Is efficient and minimizes water requirement.

Richard, Evan M.↗