MODIS Pre-launch and On-orbit Calibration

Two nearly identical MODIS instruments are currently operated on-orbit: one on-board the EOS Terra spacecraft launched in December 1999 and the other on-board the Aqua spacecraft launched in May 2002. Both sensors went through extensive pre-launch calibration and characterization activities that had provided many critically important parameters and sensor characteristics in support of their on-orbit operation and calibration. On-orbit each MODIS instrument is calibrated and characterized via a set of on-board calibrators (OBC) that include a solar diffuser (SD), a solar diffuser stability monitor (SDSM), a blackbody (BB), and a spectroradiometric calibration assembly (SRCA). This paper provides an overview of MODIS calibration and characterization methodologies and measurements performed, pre-launch and on-orbit, for both the reflective solar bands (RSB) and thermal emissive bands (TEB). It discusses issues on the calibration transfer from ground to on-board and from pre-launch to on-orbit, and illustrates the calibration consistency between Terra and Aqua MODIS. Examples in three key areas, radiometric, spatial, and spectral, are presented. Also addressed in the paper are the challenges and lessons learned during MODIS pre-launch and on-orbit calibration and performance.

Xiong, X.↗

A review of precision oscillators

Precision oscillators used in PTTI applications include quartz crystal, rubidium gas cell, cesium beam, and hydrogen maser oscillators. A general characterization and comparison of these devices is given including accuracy, stability, environmental sensitivity, size, weight, power consumption, availability and cost. Areas of special concern in practical applications are identified and a projection of future performance specifications is given. An attempt is made to predict physical and performance characteristics of new designs potentially available in the near future.

Hellwig, H.↗

Space Shuttle Main Engine (SSME) Pogo testing and results

To effectively assess the Pogo stability of the space shuttle vehicle, it was necessary to characterize the structural, propellant, and propulsion dynamics subsystems. Extensive analyses and comprehensive testing programs were established early in the project as an implementation of management philosophy of Pogo prevention for space shuttle. The role of the space shuttle main engine (SSMF) in the Pogo prevention plans, the results obtained from engine ground testing with analysis, and measured data from STS-1 flight are discussed.

Fenwick, J. R.↗

Surface film effects on drop tube undercooling studies

The effects of various gaseous atmospheric constituents on drop-tube solidified samples of elemental metals were examined from a microstructural standpoint. All specimens were prepared from the purest available elements, so effects of impurities should not account for the observed effects. The drop-tube gas has a definite effect on the sample microstructure. Most dramatically, the sample cooling rate is effected. Some samples receive sufficient cooling to solidify in free fall while others do not, splating at the end of the drop tube in the sample catcher. Gases are selectively absorbed into the sample. Upon solidification gas can become less soluble and as a result forms voids within the sample. The general oxidation/reduction characteristics of the gas also affect sample microstructures. In general, under the more favorable experimental conditions including reducing atmospheric conditions and superheatings, examination of sample microstructures indicates that nucleation has been suppressed. This is indicated by underlying uniform dendrite spacings throughout the sample and with a single dendrite orientation through most of the sample. The samples were annealed yielding a few large grains and single or bi-crystal samples were commonly formed. This was especially true of samples that were inadvertently greatly superheated. This is in contrast with results from a previous study in which surface oxides were stable and contained numerous sites of nucleation. The number of nucleation events depends upon the surface state of the specimen as determined by the atmosphere and is consistent with theoretical expectations based upon the thermodynamic stability of surface oxide films. Oxide-free specimens are characterized by shiny surfaces, with no observable features under the scanning electron microscope at 5000X.

Ethridge, E. C.↗

Microbial mats and modern stromatolites in Shark Bay, Western Australia

Distribution, external morphology, texture, and microbial composition of microbial mats in Hamelin Pool, Shark Bay, Western Australia, have been studied and reviewed along a composite representative profile starting from the permanently submerged zone, across the zones of periodic flooding, toward permanently emerged land and coastal dunes. The following nine types of algal mats have been recognized: colloform, gelatinous, smooth, pincushion, tufted, mamillate, film, reticulate, and blister. Solar ponds represent a particular environment. The mat types represent microbial communities that are characterized by one or more dominant microorganisms. The colonization and stabilization of loose sediment is carried out by a microbial assemblage of generalists that prepare the ground for later replacement and succession by specialized microflora. Lithification of microbial mats takes place periodically, mainly during the austral summer. This process is destructive for the microbial community but increases the preservation potential of the stromatolitic structures.

Golubic, S.↗

Types of planetary tori

While satellite tori are morphologically similar, they divide into dynamically distinct groups whose global balances of ions and neutrals are presently modeled in order to determine how a torus behaves as a consequence of whether it generates itself and whether it disperses or recombines in place. Six possible types of behavior result; attention is given to the equilibrium and stability of each type. The behavior of a perturbation is characterized by a trajectory in the two-dimensional space formed by the ion density and neutral density perturbations. The equilibrium is stable if a perturbation follows its trajectory toward the origin, but is unstable if the motion is away from it. An attempt is made to classify the Jupiter and Saturn tori in this light.

Huang, T. S.↗

Calibration of photon counting imaging microchannel plate detectors for EUV astronomy

The calibration of photon counting imaging detectors for satellite based EUV astronomy is a complex process designed to ensure the validity of the data received 'in orbit'. The methods developed to accomplish calibration of microchannel plate detectors for the Extreme Ultraviolet Explorer are described and illustrated. The characterization of these detectors can be subdivided into three categories: stabilization, performance tests, and environmental tests.

Siegmund, O. H. W.↗

Ladder polymers for use as high temperature stable resins or coatings

An object of the invention is to synthesize a new class of ladder and partial ladder polymers. In accordance with the invention, the new class of ladder and partial ladder polymers are synthesized by polymerizing a bis-dienophile with a bis-diene. Another object of the invention is to provide a fabricated, electrically conducting, void free composite comprising the new class of the ladder and partial ladder polymers described above. The novelty of the invention relates to a new class of ladder and partial ladder polymers and a process for synthesizing these polymers. These polymers are soluble in common organic solvents and are characterized with a unique dehydration property at temperatures of 300 to 400 C to provide thermo-oxidatively stable pentiptycene units along the polymeric backbone. These polymers are further characterized with high softening points and good thermo-oxidative stability properties. Thus these polymers have potential as processable, matrix resins for high temperature composite applications.

Meador, Mary Ann↗

The Use of Pristine and Intercalated Graphite Fiber Composites as Buss Bars in Lead-Acid Batteries

This study was conducted as a part of the Firefly Energy Space Act Agreement project to investigate the possible use of composite materials in lead acid batteries. Specifically, it examined the use of intercalated graphite composites as buss bars. Currently, buss bars of these batteries are made of lead, a material that is problematic for several reasons. Over time, the lead is subject to both corrosion at the positive plate and sulfation at the negative plate, resulting in decreased battery life. In addition, the weight and size of the lead buss bars make for a heavy and cumbersome battery that is undesirable. Functionality and practicality of lead buss bars is adequate at best; consequently, investigation of more efficient composite materials would be advantageous. Practically speaking, graphite composites have a low density that is nearly one fourth that of its lead counterpart. A battery made of less dense materials would be more attractive to the consumer and the producer because it would be light and convenient. More importantly, low weight would be especially beneficial because it would result in greater overall power density of the battery. In addition to power density, use of graphite composite materials can also increase the life of the battery. From a functional standpoint, corrosion and sulfation at the positive and negative plates are major obstacles when considering how to extend battery life. Neither of these reactions are a factor when graphite composites replace lead parts because graphite is chemically non-reactive with the electrolyte within the battery. Without the problem of corrosion or sulfation, battery life expectancy can be almost doubled. The replacement of lead battery parts with composite materials is also more environmentally favorable because of easy disposal of organic materials. For this study, both pristine and bromine intercalated single-ply graphite fiber composites were created. The composites were fabricated in such a way as to facilitate their use in a 3" x 1/2" buss bar test cell. The prime objective of this investigation was to examine the effectiveness of a variety of graphite composite materials to act as buss bars and carry the current to and from the positive and negative battery plates. This energy transfer can be maximized by use of materials with high conductivity to minimize the buss resistance. Electrical conductivity of composites was measured using both a contactless eddy current probe and a four point measurement. In addition, the stability of these materials at battery-use conditions was characterized.

Opaluch, Amanda M.↗

Solar Dynamics Observatory On-Orbit Jitter Testing, Analysis, and Mitigation Plans

The recently launched Solar Dynamics Observatory (SDO) has two science instruments onboard that required sub-arcsecond pointing stability. Significant effort has been spent pre-launch to characterize the disturbances sources and validating jitter level at the component, sub-assembly, and spacecraft levels. However, an end-to-end jitter test emulating the flight condition was not performed on the ground due to cost and risk concerns. As a result, the true jitter level experienced on orbit remained uncertain prior to launch. Based on the pre-launch analysis, several operational constraints were placed on the observatory aimed to minimize the instrument jitter levels. If the actual jitter is below the analysis predictions, these operational constraints can be relaxed to reduce the burden of the flight operations team. The SDO team designed a three-day jitter test, utilizing the instrument sensors to measure pointing jitter up to 256 Hz. The test results were compared to pre-launch analysis predictions, used to determine which operational constraints can be relaxed, and analyzed for setting the jitter mitigation strategies for future SDO operations.

Liu, Kuo-Chia↗

Impact of MODIS SWIR Band Calibration Improvements on Level-3 Atmospheric Products

The spectral reflectance measured by the MODIS reflective solar bands (RSB) is used for retrieving many atmospheric science products. The accuracy of these products depends on the accuracy of the calibration of the RSB. To this end, the RSB of the MODIS instruments are primarily calibrated on-orbit using regular solar diffuser (SD) observations. For lambda < 0.94 microns the SDs on-orbit bi-directional reflectance factor (BRF) change is tracked using solar diffuser stability monitor (SDSM) observations. For lambda > 0.94 microns, the MODIS Characterization Support Team (MCST) developed, in MODIS Collection 6 (C6), a time-dependent correction using observations from pseudo-invariant earth-scene targets. This correction has been implemented in C6 for the Terra MODIS 1.24 micron band over the entire mission, and for the 1.375 micron band in the forward processing. As the instruments continue to operate beyond their design lifetime of six years, a similar correction is planned for other short-wave infrared (SWIR) bands as well. MODIS SWIR bands are used in deriving atmosphere products, including aerosol optical thickness, atmospheric total column water vapor, cloud fraction and cloud optical depth. The SD degradation correction in Terra bands 5 and 26 impact the spectral radiance and therefore the retrieval of these atmosphere products. Here, we describe the corrections to Bands 5 (1.24 microns) and 26 (1.375 microns), and produce three sets (B5, B26 correction on/on, on/off, and off/off) of Terra-MODIS Level 1B (calibrated radiance product) data. By comparing products derived from these corrected and uncorrected Terra MODIS Level 1B (L1B) calibrations, dozens of L3 atmosphere products are surveyed for changes caused by the corrections, and representative results are presented. Aerosol and water vapor products show only small local changes, while some cloud products can change locally by > 10%, which is a large change.

Calibration↗

Advanced Mirror Technology Development (AMTD): Year Five Status

The Advanced Mirror Technology Development (AMTD) project is in Phase 2 of a multiyear effort initiated in Fiscal Year (FY) 2012, to mature the Technology Readiness Level (TRL) of critical technologies required to enable 4-m-or-larger monolithic or segmented ultraviolet, optical, and infrared (UVOIR) space telescope primary-mirror assemblies for general astrophysics, ultra-high-contrast observations of exoplanets, and National Interest missions. Key accomplishments of 2016/17 include the completion of the Harris Corp approximately 150 Hz 1.5-meter Ultra-Low Expansion (ULE Registered trademark) mirror substrate using stacked core method to demonstrate lateral stability of the stacked core technology, as well as the characterization and validation by test of the mechanical and thermal performance of the 1.2-meter Zerodur (Registered trademark) mirror using the STOP model prediction and verification of CTE homogeneity.

Space Mirror Technology↗

Barium Fluoride as a Standard Reference Material for Infrared Refractometry

This work proposes a standard reference material (SRM) for measurements of refractive index in the infrared spectral region (1–12 μm). The purpose of this material is to enable cross-method comparison of refractive index data obtained through minimum deviation, ellipsometry, interferometry, and prism coupling techniques. This will allow vendors and metrology laboratories, regardless of which technique they employ, to certify that their measurements meet required levels of accuracy, precision, and repeatability. Drawing on foundational work by Tilton at the National Bureau of Standards, a figure of merit for candidate SRM materials is outlined, and three materials are selected for further evaluation. Ultimately, barium fluoride is proposed as the most suitable SRM for the infrared spectral region, based on its broad transmission range, chemical and mechanical stability, low temperature dependence of refractive index, and well-characterized dispersion behavior.

Andrew Howe↗

Results and Lessons from MODIS Reflective Solar Bands Calibration: Pre-launch to On-orbit

MODIS is a major instrument for the NASA EOS Terra (1aunched in December 1999) and Aqua (launched in May 2002) missions. It was designed and built to enhance and extend its heritage sensors' measurements and data records with applications covering a wide range of studies of the Earth's land, oceans, and atmosphere. MODIS has 36 spectral bands (0.41 - 14.4 micrometers) located on four focal plane assemblies (FPAs). It makes measurements at three nadir spatial resolutions: 250m (bands 1-2), 500m (bands 3-7), and lkm (bands 8-36). Because of instrument design complexity and stringent calibration requirements, extensive calibration and characterization activities were conducted pre-launch by the sensor vendor (Raytheon / Santa Barbara Remote Sensing) for both Tesa and Aqua MODIS. For the 20 reflective solar bands (RSB), these activities include measurements for the detectors noise characterization and radiometric performance, system level response versus scan-angle (RVS), polarization sensitivity, and relative spectral response (RSR). Key radiometric performance was evaluated using thermal vacuum observations. On-orbit MODIS RSB calibration is performed using a solar diffuser (SD) and solar diffuser stability monitor (SDSM) system. The SD bi-directional reflectance factor (BRF) was characterized pre-launch by the sensor vendor with reference samples traceable to NIST reflectance standards. This paper provides a summary of Terra and Aqua MODIS RSB pre-launch and on-orbit calibration and characterization activities and results with focus on the detectors' noise characterization and radiometric performance. Challenging and concerning issues and lessons learned from RSB pre-launch calibration and their impact on post launch performance are also presented. A similar summary for MODIS thermal emissive bands (TEB) is reported in a separate paper in these proceedings.

Xiong, X.↗

Characterization and durability testing of plasma-sprayed zirconia-yttria and hafnia-yttria thermal barrier coatings. Part 1: Effect of spray parameters on the performance of several lots of partially stabilized zirconia-yttria powder

Initial experiments conducted on thermal barrier coatings prepared in the newly upgraded research plasma spray facility and the burner rig test facilities are discussed. Part 1 discusses experiments which establish the spray parameters for three baseline zirconia-yttria coatings. The quality of five similar coating lots was judged primarily by their response to burner rig exposure supplemented by data from other sources such as specimen characterizations and thermal diffusivity measurements. After allowing for burner rig variability, although there appears to be an optimum density (i.e., optimum microstructure) for maximum burner rig life, the distribution tends to be rather broad about the maximum. In Part 2, new hafnia-yttria-based coatings were evaluated against both baseline and alternate zirconia-yttria coatings. The hafnia-yttria coatings and the zirconia-yttria coatings that were prepared by an alternate powder vendor were very sensitive to plasma spray parameters, in that high-quality coatings were only obtained when certain parameters were employed. The reasons for this important observation are not understood. Also not understood is that the first of two replicate specimens sprayed for Part 1 consistently performed better than the second specimen. Subsequent experiments did not display this spray order affect, possibly because a chiller was installed in the torch cooling water circuit. Also, large changes in coating density were observed after switching to a new lot of electrodes. Analyses of these findings were made possible, in part, because of the development of a sensitive density measurement technique described herein in detail. The measured thermal diffusivities did not display the expected strong relationship with porosity. This surprising result was believed to have been caused by increased microcracking of the denser coatings on the stainless steel substrates.

Miller, Robert A.↗

High-temperature Adhesive Development and Evaluation

High-temperature adhesive systems are evaluated for short and long-term stability at temperatures ranging from 232C to 427C. The resins selected for characterization include: NASA Langley developed polyphenylquinoxaline (PPQ), and commercially available polyimides (PI). The primary method of bond testing is single lap shear. The PPQ candidates are evaluated on 6A1-4V titanium adherends with chromic acid anodize and phosphate fluoride etch surface preparations. The remaining adhesives are evaluated on 15-5 PH stainless steel with a sulfuric acid anodize surface preparation. Preliminary data indicate that the PPQ adhesives tested have stability to 3000 hours at 450F with chromic acid anodize surface preparation. Additional studies are continuing to attempt to improve the PPQ's high-performance by formulating adhesive films with a boron filler and utilizing the phosphate fluoride surface preparation on titanium. Evaluation of the polyimide candidates on stainless-steel adherends indicates that the FM-35 (American Cyanamid), PMR-15 (U.S. Polymeric/Ferro), TRW partially fluorinated polyimide and NR 150B2S6X (DuPont) adhesives show sufficient promise to justify additional testing.

Hendricks, C. L.↗

Radiometric Stability in 16 years of AIRS Hyperspectral Infrared Data (SPIE OP-431-20)

With global warming at the rate of 10 mK/yr, it is important to at least characterize any trend in the AIRS data, which may impact the use of AIRS data for climate change research. We evaluated the stability of the AIRS v5 calibration for seven atmospheric window channels between 2002 and 2018 under tropical ocean clear conditions. Trends for the channels between 961, 1128 and 1231 cm-1 channels are typically +3 mK/yr; for 790 and 901 cm-1 the trend is 6 mK/yr, i.e. the observations are increasingly getting warmer than expected. The trends are day/night consistent. The trend for the 2508 and 2616 cm-1 channels is close to 10 mK/yr at night, but closer to 6 mK/yr during the day. On an absolute scale these trends are small, but not when viewed in the context of global warming at a 10 mK/yr rate. While the warming trends are consistent with increased scattering from the scan mirrors, which create an error in reading the Onboard Blackbody Calibration, the resulting changes in the gain are a factor of about five larger than observed changes in the gain. The effects of scattering due to scan mirror contamination are evident at extremely cold temperatures, but scattering does not produce the observed warming at warm temperatures. It is possible that much of the observed warming in the AIRS window channels is a geophysical effect related to the warming of the oceans, resulting in a shift in the diurnal cycle and skin effect correction. This requires more careful evaluation.

Manning, Evan M.↗