Multi-Segmented Electron Spectrometer for the measurement of E0 transitions
Oral presentation describing the development and commissioning of the MUlti-Segmented Electron conversion Spectrometer (MUSES).
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Oral presentation describing the development and commissioning of the MUlti-Segmented Electron conversion Spectrometer (MUSES).
Satellite measurements of plasma density and temperature help predict the intensity of geomagnetic storms, which can impact satellites, communications, and power systems. Accurate forecasting requires knowledge of plasma composition. However, typical orbital mass spectrometers have difficulty distinguishing between nitrogen (N+) and oxygen (O+) ions due to their similar masses. This limitation makes it difficult to validate modern space weather models, which depend on accurate knowledge of ion composition in near-Earth space. N+ and O+ ions behave differently in space due to differences in their origin, transport, and loss mechanisms. Improving our ability to distinguish between these ions is critical for understanding and predicting space weather.
We are developing a polarized 3He target for use in high luminosity electron scattering experiments within the high magnetic field environment of Jefferson Lab's CLAS12 spectrometer. By combining recent advancements in metastability exchange optical pumping (MEOP) of 3He with cryogenic, double-cell target methods as used for the MIT-Bates 88-02 experiment, a target with polarization and gas density comparable to traditional, low-field polarized 3He targets can be reached within high magnetic field environments. We have begun polarizing sealed 3He cells at fields up to 5 T at Jefferson Lab, and are preparing for our first tests exploring polarization performance versus magnetic field and gas pressure in a single cell before we move to the construction of a full, cryogenic, double-cell prototype target. A key focus of our research is the determination of polarization relaxation under the irradiation of an ionizing particle beam within high magnetic fields.
The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.
We present field deployment results of a portable optical absorption spectrometer for localization and quantification of fugitive methane (CH 4 ) emissions. Our near-infrared sensor targets the 2$ν_3$ R(4) CH 4 transition at 6057.1 cm −1 (1651 nm) via line-scanned tunable diode-laser absorption spectroscopy (TDLAS), with Allan deviation analysis yielding a normalized 2.0 ppmv∙Hz −1/2 sensitivity (4.5 × 10 −6 Hz −1/2 noise-equivalent absorption) over 5 cm open-path length. Controlled CH 4 leak experiments are performed at the METEC CSU engineering facility, where concurrent deployment of our TDLAS and a customized volatile organic compound (VOC) sensor demonstrates good linear correlation (R 2 = 0.74) over high-flow (>60 SCFH) CH 4 releases spanning 4.4 h. In conjunction with simultaneous wind velocity measurements, the leak angle-of-arrival (AOA) is ascertained via correlation of CH 4 concentration and wind angle, demonstrating the efficacy of single-sensor line-of-sight (LOS) determination of leak sources. Finally, source magnitude estimation based on a Gaussian plume model is demonstrated, with good correspondence (R 2 = 0.74) between calculated and measured release rates.
X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO 2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.
Knowledge of the chemical composition and mixing state of aerosols at a single-particle level is critical for gaining insights into atmospheric processes. One common tool to make these measurements is single-particle mass spectrometry. There remains a need to compare the performance of different single-particle mass spectrometers (SPMSs). An intercomparison of SPMSs was conducted at the Aerosol Interaction and Dynamics in the Atmosphere (AIDA) chamber at the Karlsruhe Institute of Technology (KIT) in November 2014, as part of the first phase of the Fifth International Workshop on Ice Nucleation (FIN-01). In this paper we compare size distributions and mass spectra of atmospherically relevant particle types measured by five SPMSs. These include different minerals, desert and soil dusts, soot, bioaerosol (Snomax; protein granule), secondary organic aerosol (SOA), and SOA-coated mineral particles. Most SPMSs reported similar vacuum aerodynamic diameter (d va ) within typical instrumental ranges from ~100–200 nm (lower limit) to ~2–3 µm (upper limit). In general, all SPMSs exhibited a wide dynamic range (up to ~10 3 ) and high signal-to-noise ratio (up to ~10 4 ) in mass spectra. Common spectral features with small diversities in mass spectra were found with high average Pearson's correlation coefficients, i.e., for average positive spectra r avg-pos =0.74 ± 0.12 and average negative spectra r avg-neg =0.67 ± 0.22. We found that instrument-specific detection efficiency (DE) was more dependent on particle size than particle type, and particle identification favored the use of bipolar, rather than monopolar, instruments. Particle classification from “blind experiments” showed that all instruments differentiated SOA, soot, and soil dust and detected subtle changes in the particle internal mixing but had difficulties differentiating among specific mineral types and dusts. This study helps to further understand the capabilities and limitations of the single-particle mass spectrometry technique in general and the specific performance of the instrument in characterizing atmospheric aerosol particles.
Retrievals of total column NO 2 (TCNO 2 ) are compared for 14 sites from the Ozone Measuring Instrument (OMI using OMNO2-NASA v3.1) on the AURA satellite and from multiple ground-based PANDORA spectrometer instruments making direct-sun measurements. While OMI accurately provides the daily global distribution of retrieved TCNO 2 , OMI almost always underestimates the local amount of TCNO 2 by 50 % to 100 % in polluted areas, while occasionally the daily OMI value exceeds that measured by PANDORA at very clean sites. Compared to local ground-based or aircraft measurements, OMI cannot resolve spatially variable TCNO 2 pollution within a city or urban areas, which makes it less suitable for air quality assessments related to human health. In addition to systematic underestimates in polluted areas, OMI's selected 13:30 Equator crossing timepolar orbit causes it to miss the frequently much higher values of TCNO 2 that occur before or after the OMI overpass time. Six discussed Northern Hemisphere PANDORA sites have multi-year data records (Busan,Seoul, Washington DC, Waterflow, New Mexico, Boulder, Colorado, and Mauna Loa),and one site in the Southern Hemisphere (Buenos Aires, Argentina). The first four of these sites and Buenos Aires frequently have high TCNO 2 (TCNO 2 > 0.5 DU). Eight additional sites have shorter-term data records in the US and South Korea. One of these is a 1-year data record from a highly polluted site at City College in New York City with pollution levels comparable to Seoul, South Korea. OMI-estimated air mass factor, surface reflectivity, and the OMI 24 km × 13 km FOV (field of view)are three factors that can cause OMI to underestimate TCNO 2 . Because of the local inhomogeneity of NO x emissions, the large OMI FOV is the most likely factor for consistent underestimates when comparing OMI TCNO 2 to retrievals from the small PANDORA effective FOV (measured in m 2 ) calculated from the solar diameter of 0.5°.
Abstract. Aerosol hygroscopic growth plays an important role in atmospheric particle chemistry and the effects of aerosol on radiation and hence climate. The hygroscopic growth is often characterized by a growth factor probability density function (GF-PDF), where the growth factor is defined as the ratio of the particle size at a specified relative humidity to its dry size. Parametric, least-squares methods are the most widely used algorithms for inverting the GF-PDF from measurements of the humidified tandem differential mobility analyzer (HTDMA) and have been recently applied to the GF-PDF inversion from measurements of the humidity-controlled fast integrated mobility spectrometer (HFIMS). However, these least-squares methods suffer from noise amplification due to the lack of regularization in solving the ill-posed problem, resulting in significant fluctuations in the retrieved GF-PDF and even occasional failures of convergence. In this study, we introduce nonparametric, regularized methods to invert the aerosol GF-PDF and apply them to HFIMS measurements. Based on the HFIMS kernel function, the forward convolution is transformed into a matrix-based form, which facilitates the application of the nonparametric inversion methods with regularizations, including Tikhonov regularization and Twomey's iterative regularization. Inversions of the GF-PDF using the nonparameteric methods with regularization are demonstrated using HFIMS measurements simulated from representative GF-PDFs of ambient aerosols. The characteristics of reconstructed GF-PDFs resulting from different inversion methods, including previously developed least-squares methods, are quantitatively compared. The result shows that Twomey's method generally outperforms other inversion methods. The capabilities of Twomey's method in reconstructing the pre-defined GF-PDFs and recovering the mode parameters are validated.
This data set contains atmospheric ice nucleating particle (INP) measurements, using Colorado State University’s (CSU) Ice Spectrometer (IS), of filter collections taken at the U.S. DOE ARM AMF2 site onboard the R/V Polarstern P-deck during the Multidisciplinary Drifting Observatory for the Study of Arctic Climate (MOSAiC) field campaign. Samples were collected from October 27, 2019 to September 24, 2020. A filter sampler was mounted approximately 15 m above ground level on a railing in proximity to (and approximately 3 m below) the Aerosol Observation System (AOS) inlet. Single-use filter units open to the atmosphere were pre-cleaned and pre-loaded with 47-mm diameter Nuclepore polycarbonate (0.2 µm pore-diameter) filters. Filters were typically drawn for a three-day period, with an average volume of air filtered of 87,000 standard liters. Total volumes were calculated through recorded daily flow rates using a mass flow meter (TSI). After collection, filters were stored and transported frozen until analysis using CSU’s IS instrument (McCluskey et al., 2018). Aerosol particles were first re-suspended in 8 mL of 0.1 µm-filtered deionized (DI) water. Aliquots of each suspension, and corresponding 11-fold dilutions, were dispensed into polymerase chain reaction (PCR) trays and placed into the aluminum blocks of the IS. Samples were cooled at approximately 0.33 °C min -1 and freezing detected optically with corresponding temperatures recorded. Cumulative INP concentrations were determined through calculating the number of INPs per mL of suspension (Vali, 1971) and converting to concentration per standard L of air by accounting for the proportion of liquid used and volume of air collected. All samples were corrected for the number of INPs on the average of four field blanks (cleaned, handled, transported, and analyzed in the same way without air flow). Two-tailed, 95% confidence intervals for binomial sampling are provided (Agresti and Coull, 1998). Select samples were also heat treated (95 °C for 20 min) to denature and deactivate biological INPs present and digested in 10% H 2 O 2 at 95 °C under UV-B for 20 min to remove any organic carbon INPs. Agresti, A, and BA Coull. 1998. "Approximate is better than “exact” for interval estimation of binomial proportions." American Statistics 52: 119–126. https://doi.org/10.2307/2685469 McCluskey, CS, J Ovadnevaite, M Rinaldi, J Atkinson, F Belosi, D Ceburnis, … and PJ DeMott. 2018. "Marine and Terrestrial Organic Ice-Nucleating Particles in Pristine Marine to Continentally Influenced Northeast Atlantic Air Masses." Journal of Geophysical Research: Atmospheres 123 (11): 6196–6212, https://doi.org/10.1029/2017JD028033 Vali, G. 1971. "Quantitative Evaluation of Experimental Results and the Heterogeneous Freezing Nucleation of Supercooled Liquids." Journal of the Atmospheric Sciences 28: 402-209. https://doi.org/10.1175/1520-0469(1971)028<0402:QEOERA>2.0.CO;2
Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Soot particle-Aerosol Mass Spectrometer. (Aerodyne Inc.) Header: - Organic_GCVIoff[ug/m3]: Concentration of organic compounds measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Nitrate_GCVIoff[ug/m3]: Concentration of nitrate measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Sulfate_GCVIoff[ug/m3]: Concentration of sulfate measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Chloride_GCVIoff[ug/m3]: Concentration of chloride measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Ammonium_GCVIoff[ug/m3]: Concentration of ammonium via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Organic_GCVIon[ug/m3]: Concentration of organic compounds measured in-cloud via CVI in micrograms per cubic meter. - Nitrate_GCVIon[ug/m3]: Concentration of nitrate measured in-cloud via CVI in micrograms per cubic meter. - Sulfate_GCVIon[ug/m3]: Concentration of sulfate measured in-cloud via CVI in micrograms per cubic meter. - Chloride_GCVIon[ug/m3]: Concentration of chloride measured in-cloud via CVI in micrograms per cubic meter. - Ammonium_GCVIon[ug/m3]: Concentration of ammonium measured in-cloud via CVI in micrograms per cubic meter. - CVI_Flag[bool]: A boolean flag indicating whether the CVI was active (true) or inactive (false) during the measurement.
These measurements are provided by a differential mobility analyzer operated as a scanning mobility particle sizer, a printed particle optical spectrometer (POPS), and a continuous flow diffusion cloud condensation nuclei (CCN) counter. The instruments sample from either a counterflow virtual impactor inlet or an isokinetic inlet. The measurements provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. CCN measurements are performed in denuded and undenuded configuration, where denuded refers to the removal of low molecular weight organic vapors. A detailed NetCDF header is included with the datafiles. Users of these measurements are encouraged to consult with the authors about appropriate interpretation before submitting for publication, offering coauthorship where appropriate.
Measurements of non-refractory, sub-micron aerosol composition, namely organic, sulfate, nitrate, chloride, and ammonium aerosols, by a mini- aerosol mass spectrometer (mAMS, Aerodyne Research, Inc.) are reported. The instrument sampled ambient air through 3 different inlets: unperturbed ambient air, a Counter-flow Virtual Impactor (CVI), and an oxidation flow reactor (OFR). Users should consult the Sampling Key for proper interpretation of the data.
We are developing a polarized 3He target concept for use in high luminosity electron scattering experiments in the high magnetic field environment of Jefferson Lab's CLAS12 spectrometer. By combining recent advancements in metastability exchange optical pumping of 3He with cryogenic, double-cell target methods such as those used for the MIT-Bates 88-02 experiment, a target with polarization and gas density comparable to traditional, low-field polarized 3He targets can be reached within high magnetic fields. We have established a new 3He pumping system at JLab, and are preparing for our first tests exploring polarization performance versus magnetic field and gas pressure in a single cell before we move to the construction of a full, cryogenic, double-cell prototype target.
I describe a possible Forward Multiparticle Spectrometer (FMS) that could be installed downstream of the superconducting recombination dipole D1 in Run 4, from z = 96 m - 126 m to measure multi-TeV hadron spectra in low luminosity p + p collisions at Rt(s) = 14 TeV, as well as p + O and O + O collisions as relevant for cosmic ray showers. Light antinuclei and charmed hadrons at high Feynman xF can be measured, both of importance for astrophysics. At the full high luminosity HL-LHC a search for new long-lived neutral particles (LLPs) decaying in a 20 m long, 70 cm diameter vacuum pipe to visible decay modes (including gamma+gamma, e+e-, mu+mu-, tau+tau-, ccbar and jets) can be made. The FMS is especially well suited for LLPs with 1 GeV < M(X)< 10 GeV and lifetimes c.tau from about 10 m to several km. I discuss this as a possible addition to CMS but it has no formal approval yet, therefore the talk is not given on behalf of CMS.
An x-ray spectrometer includes: an x-ray plasma source that produces first x-rays; an x-ray optic in optical communication with the x-ray plasma source and that: receives the first x-rays from the x-ray plasma source; focuses the first x-rays to produce second x-rays; and communicates the second x-rays to a sample that produces product x-rays in response to receipt of the second x-rays and second light; and a microcalorimeter array detector in optical communication with the sample and that receives the product x-rays from the sample.
The next generation of long-baseline neutrino experiments will be capable of precision measurements of neutrino oscillation parameters, precision neutrino-nucleus scattering, and unprecedented sensitivity to physics beyond the Standard Model. Reduced uncertainties in neutrino fluxes are necessary to achieve high precision and sensitivity in these future precise neutrino measurements. New measurements of hadron-nucleus interaction cross sections are needed to reduce uncertainties of neutrino fluxes. We report measurements of the differential cross-section as a function of scattering angle for proton-carbon interactions with a single charged particle in the final state at beam momenta of 20, 30, and 120 GeV/c. These measurements are the result of a beam test for EMPHATIC, a hadron-scattering and hadron-production experiment. The total, elastic and inelastic cross-sections are also extracted from the data and compared to previous measurements. These results can be used in current and future long-baseline neutrino experiments, and demonstrate the feasibility of future measurements by an upgraded EMPHATIC spectrometer.
63rd Annual Meeting of the APS Division of Plasma Physics November 8-12, 2021 • Pittsburgh, Pennsylvania Virtual presentation must be uploaded by Nov 3rd 2pm PST Session Date / Time: 11/11/2021, 2:00 pm - 5:00 pm Title: HED: Laboratory Astrophysics Type: Oral Contributed Presentation: Higher order and penumbral blurring correction methodology for Opacity spectrometer used on the NIF.