Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sorbent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Advanced Supported Liquid Membranes for Carbon Dioxide Control in Cabin Applications

The development of new, robust, life support systems is critical to NASA's continued progress in space exploration. One vital function is maintaining the carbon dioxide (CO2) concentration in the cabin at levels that do not impair the health or performance of the crew. The carbon dioxide removal assembly (CDRA) is the current CO2 control technology on-board the International Space Station (ISS). Although the CDRA has met the needs of the ISS to date, the repeated cycling of the molecular sieve sorbent causes it to break down into small particles that clog filters or generate dust in the cabin. This reduces reliability and increases maintenance requirements. Another approach that has potential advantages over the current system is a membrane that separates CO2 from air. In this approach, cabin air contacts one side of the membrane while other side of the membrane is maintained at low pressure to create a driving force for CO2 transport across the membrane. In this application, the primary power requirement is for the pump that creates the low pressure and then pumps the CO2 to the oxygen recovery system. For such a membrane to be practical, it must have high CO2 permeation rate and excellent selectivity for CO2 over air. Unfortunately, conventional gas separation membranes do not have adequate CO2 permeability and selectivity to meet the needs of this application. However, the required performance could be obtained with a supported liquid membrane (SLM), which consists of a microporous material filled with a liquid that selectively reacts with CO2 over air. In a recently completed Phase II SBIR project, Reaction Systems, Inc. fabricated an SLM that is very close to meeting permeability and selectivity objectives for use in the Portable Life Support System (PLSS). This paper describes work carried out to evaluate its potential for use in the cabin.

Wickham, David T.↗

Design and Development Comparison of Rapid Cycle Amine 1.0, 2.0, and 3.0

The development of the Rapid Cycle Amine (RCA) swing-bed technology for carbon dioxide (CO2) removal has been in progress since favorable results were published in 1996. Shortly thereafter, a prototype was designed, developed, and tested successfully and delivered to Johnson Space Center in 1999. An improved prototype (RCA 1.0) was delivered to NASA in 2006 and sized for the extravehicular activity (EVA). The RCA swing-bed technology is a regenerative system which employs two alternating solid-amine sorbent beds to remove CO2 and water. The two-bed design employs a chemisorption process whereby the beds alternate between adsorption and desorption. This process provides for an efficient RCA operation that enables one bed to be in adsorb (uptake) mode, while the other is in the desorb (regeneration) mode. The RCA has progressed through several iterations of technology readiness levels. Test articles have now been designed, developed, and tested for the advanced space suit portable life support system (PLSS) including RCA 1.0, RCA 2.0, and RCA 3.0. The RCA 3.0 was the most recent RCA fabrication and was delivered to NASA-JSC in June 2015. The RCA 1.0 test article was designed with a pneumatically actuated linear motion spool valve. The RCA 2.0 and 3.0 test articles were designed with a valve assembly which allows for switching between uptake and regeneration modes while minimizing gas volume losses to the vacuum source. RCA 2.0 and 3.0 also include an embedded controller design to control RCA operation and provide the capability of interfacing with various sensors and other ventilation loop components. The RCA technology is low power, small, and has fulfilled all test requirements levied upon the technology during development testing thus far. This paper will provide an overview of the design and development of RCA 1.0, 2.0 and 3.0 including detail differences between the design specifications of each. Nomenclature.

Chullen, Cinda↗

Visible-Light-Responsive Photocatalysis: Ag-Doped TiO2 Catalyst Development and Reactor Design Testing

In recent years, the alteration of titanium dioxide to become visible-light-responsive (VLR) has been a major focus in the field of photocatalysis. Currently, bare titanium dioxide requires ultraviolet light for activation due to its band gap energy of 3.2 eV. Hg-vapor fluorescent light sources are used in photocatalytic oxidation (PCO) reactors to provide adequate levels of ultraviolet light for catalyst activation; these mercury-containing lamps, however, hinder the use of this PCO technology in a spaceflight environment due to concerns over crew Hg exposure. VLR-TiO2 would allow for use of ambient visible solar radiation or highly efficient visible wavelength LEDs, both of which would make PCO approaches more efficient, flexible, economical, and safe. Over the past three years, Kennedy Space Center has developed a VLR Ag-doped TiO2 catalyst with a band gap of 2.72 eV and promising photocatalytic activity. Catalyst immobilization techniques, including incorporation of the catalyst into a sorbent material, were examined. Extensive modeling of a reactor test bed mimicking air duct work with throughput similar to that seen on the International Space Station was completed to determine optimal reactor design. A bench-scale reactor with the novel catalyst and high-efficiency blue LEDs was challenged with several common volatile organic compounds (VOCs) found in ISS cabin air to evaluate the system's ability to perform high-throughput trace contaminant removal. The ultimate goal for this testing was to determine if the unit would be useful in pre-heat exchanger operations to lessen condensed VOCs in recovered water thus lowering the burden of VOC removal for water purification systems.

Photocatalysis↗

NASA ISS Portable Fan Assembly Acoustics

The Portable Fan Assembly (PFA) is a variable speed fan that can be used to provide additional ventilation inside International Space Station (ISS) modules as needed for crew comfort or for enhanced mixing of the ISS atmosphere. This fan can also be configured with a Shuttle era lithium hydroxide (LiOH) canister for CO2 removal in confined areas partially of fully isolated from the primary Environmental Control and Life Support System (ECLSS) on ISS which is responsible for CO2 removal. This report documents noise emission levels of the PFA at various speed settings and configurations. It also documents the acoustic attenuation effects realized when circulating air through the PFA inlet and outlet mufflers and when operating in its CO2 removal configuration (CRK) with a LiOH canister (sorbent bed) installed over the fan outlet.

Boone, Andrew↗

Evaluation of a Candidate Trace Contaminant Control Subsystem Architecture: The High Velocity, Low Aspect Ratio (HVLA) Adsorption Process

Traditional gas-phase trace contaminant control adsorption process flow is constrained as required to maintain high contaminant single-pass adsorption efficiency. Specifically, the bed superficial velocity is controlled to limit the adsorption mass-transfer zone length relative to the physical adsorption bed; this is aided by traditional high-aspect ratio bed design. Through operation in this manner, most contaminants, including those with relatively high potential energy are readily adsorbed. A consequence of this operational approach, however, is a limited available operational flow margin. By considering a paradigm shift in adsorption architecture design and operations, in which flows of high superficial velocity are treated by low-aspect ratio sorbent beds, the range of well-adsorbed contaminants becomes limited, but the process flow is increased such that contaminant leaks or emerging contaminants of interest may be effectively controlled. To this end, the high velocity, low aspect ratio (HVLA) adsorption process architecture was demonstrated against a trace contaminant load representative of the International Space Station atmosphere. Two HVLA concept packaging designs (linear flow and radial flow) were tested. The performance of each design was evaluated and compared against computer simulation. Utilizing the HVLA process, long and sustained control of heavy organic contaminants was demonstrated.

Kayatin, Matthew J.↗

Virtual Design of a Four-Bed Molecular Sieve for Exploration

Aboard the International Space Station, CO2 is removed from the cabin atmosphere by a four-bed molecular sieve (4BMS) process called the Carbon Dioxide Removal Assembly (CDRA).1 This 4BMS process operates by passing the CO2-laden air through a desiccant bed to remove any humidity and then passing the dried air through a sorbent bed to remove the CO2. While one pair of beds is in use, the other pair is thermally regenerated to allow for continuous CO2 removal.

Giesy, T. J.↗

Material Analysis and System Design for Exploration Life Support Systems 2017

Advanced Environmental Control and Life Support System (ECLSS) design is critical for manned space flight beyond Earth. Current systems enable extended missions in low-Earth orbit, but for deep-space missions, not only will astronauts be outside the reach of resupply operations from Earth but they will also need to handle malfunctions and compensate for the degradation of materials. These two daunting challenges must be overcome for long-term independent space flight. In order to solve the first, separation and recycling of onboard atmosphere is required. Current systems utilize space vacuum to fully regenerate CO2 sorbent beds, but this is not sustainable. The second challenge stems from material and performance degradation due to operational cycling and on-board contaminants. This report will review the recent work by the ECLSS team at Marshall Space Flight Center towards overcoming these challenges by characterizing materials via novel methods and by assessing new air revitalization systems.

Knox, Jim↗

Co-Adsorption of Carbon Dioxide on Zeolite 13X in the Presence of Preloaded Water

Environmental Control and Life Support requires highly effective CO2 removal systems. The current system onboard the International Space Station is known as Carbon Dioxide Removal Assembly. Recent high-fidelity simulation of this system predicted a major efficiency gain via reduction of desiccant zeolite. Commercial beaded 13X zeolite is used in the desiccant bed to scrub water below 1 ppm but is also a highly active CO2 sorbent. The simultaneous adsorption of water vapor and CO2 is known to strongly favor water, but more accurate measurements are needed. This work details the characterization of the zeolite to be used in the next-generation CO2 removal system for co-adsorption of water and CO2.

Cmarik, Gregory E↗

Co-Adsorption of Carbon Dioxide on Zeolite 13X in the Presence of Preloaded Water

Background: Carbon Dioxide removal is a key aspect of Life Support for long-duration missions - Need to improve Mass, Power, and Volume of systems; Cabin air has three major constituents - Oxygen and Nitrogen, Carbon dioxide (CO2), Water Vapor; The mechanism for strong CO2 adsorption in zeolites (and many sorbents) is also the same mechanism for H2O - Water vapor is selectively adsorbed over CO2.

Cmarik, Gregory E.↗

Upgrades to the International Space Station Water Processor Assembly

The International Space Station Water Processor Assembly provides contaminant control and deionization to the Water Recovery System. The Water Processor Assembly presently utilizes sorbent-based Multifiltration Beds and a downstream Catalytic Reactor for these operations. Upgrades and process improvements are desired to improve performance, increase reliability, and decrease consumable resupply. To this end, reverse osmosis membrane separation technologies were evaluated to reduce influent contaminant loads, candidate additives to inhibit wastewater biofilm formation were studied, and life stability testing was completed for a recently developed high-activity catalyst. Evaluation of an adsorption media integration concept was also completed. The performance and applicability of these new technologies within the Water Processor Assembly, as well as their suitability for exploration missions, are discussed herein.

Kayatin, Matthew J.↗

Evaluation of Ionic Liquids for Closed Air Revitalization

This document is the final report resulting from the work conducted by undergraduate students at the University of South Alabama during the 2018/2019 academic year and was prepared by the undergraduate students. As NASA pushes the boundaries further into space, the current technologies within the various life support systems must be improved upon. One such improvement is needed to the current air revitalization systems, specifically sorbents that can capture CO2 more effectively from enclosed habitats. Ionic liquids (ILs) have been considered as absorbents for flue gas, but little research has been done to test the ability of ILs at ambient pressures and relatively low concentration of CO2. The experiment outlined below utilizes the task-specific ionic liquid, tetramethylammonium taurinate (TMN), in a commercial off the shelf absorption system to capture CO2. The CO2 stream is combined with nitrogen to produce an inlet gas concentration relevant to close air revitalization applications. At an inlet gas flow with a CO2 partial pressure of 3.8 torr the system was capable of removing just under 97% of the inlet CO2. The concentration of CO2 in the outlet stream, partial pressure 0.16 torr, was less than that of atmospheric air. The duty required to separate the absorbed gas from the ionic liquid as well to cool the ionic liquid to be reintroduced to the column were acquired utilizing laboratory cooling/heating baths. These results show that TMN may be an efficient candidate for consideration in closed air revitalization.

Duck, Gerald↗

CO2 Removal Onboard the International Space Station – Material Selection and System Design

The previous three years of efforts have focused on the study of the sorbent materials available for use in a 4-bed molecular sieve system. The accumulation of knowledge has been invaluable for further decisions and for reflecting on the conclusions of past decisions. The goal of the next system is perfect uptime for nearly 20,000 hours of operation, but no complex life support system has yet reached this lofty goal. In addition to reliability, CO2 removal performance improvements have been intensively studied. The achievements toward this end include highly detailed isotherm measurements which drive system simulations as well as testing physical design improvements. Looking back on the successes and failures of past systems, correlating tests with long-duration data, and carefully projecting the future are all needed for the success of the next system. This work intends to reveal the path we have taken and illuminate the steps to come for CO2 removal life support with the 4BCO2 flight demonstration.

Cmarik, Gregory E.↗

CO2 Removal for the International Space Station – 4-Bed Molecular Sieve Material Selection and System Design

Efforts over the past three years have focused on the study of candidate sorbent materials for use in a 4BMS molecular sieve system. The accumulation of knowledge has been invaluable for further decisions and for reflecting on the conclusions of past decisions. The goal of the next generation CO2 removal system is continuous, failure-free operation for nearly 20,000 hours, but no complex life support system has yet reached this lofty goal. In addition to reliability, CO2 removal performance improvements have been intensively studied. The achievements toward this end include highly detailed isotherm measurements which drive system simulations as well as testing physical design improvements. Looking back on the successes and failures of past systems, correlating data from long-duration tests, and carefully projecting future results are all needed for the success of the next system. This work intends to reveal the path we have taken and illuminate the steps to come for CO2 removal life support with the 4BCO2 flight demonstration.

Cmarik, Gregory E.↗

Final Report: NASA X-HAB Space Habitat Research Group Iowa State University

This document serves as the Final Report for Iowa State University's Space Habitat group to fulfill the specifications of NASA's eXploration Systems and Habitation (X-Hab) 2019 Academic Innovation Challenge for the 'Implementation of Advanced Sorbents in a Carbon Dioxide Management Unit' portion of the challenge. The scope of this document includes a description of the current Carbon Dioxide management systems implemented on ISS, a description of the group’s design, a description of the operational environment and scenarios, risks and mitigations, performance and testing results of the system, outreach, and future work.

Smalls, Nevin↗

Electrochemical Solutions for Advanced Life Support

The Oxygen Generating Assembly (OGA) on-board the International Space Station (ISS) employs a polymer electrolyte membrane (PEM) water electrolysis cell stack to electrochemically dissociate water into its two components – oxygen and hydrogen. Oxygen is provided to the cabin atmosphere for crew respiration while the hydrogen is delivered to a carbon dioxide reduction system to recover oxygen as water. The design of the OGA evolved over a number of years to arrive at the system solution that is currently operational on ISS. Future manned missions to space will require advanced technologies that eliminate the need for resupply from earth and feature in-situ resource utilization to sustain crew life and to provide useful materials to the crew. The architects planning such missions should consider all potential solutions at their disposal to arrive at an optimal vehicle solution that minimizes crew maintenance time, launch weight, installed volume and energy consumption demands. Skyre is developing new technologies through funding from NASA, the Department of Energy, and internal investment based on PEM technology that could become an integral part of these new vehicle solutions. At varying stages of Technology Readiness Level (TRL) are: an oxygen concentrator and compressor that can separate oxygen from an air stream and provide an enriched oxygen resource for crew medical use and space suit recharge without any moving parts in the pure oxygen stream; a regenerative carbon dioxide removal system featuring a PEM-based sorbent regenerator; a carbon dioxide reduction system that electrochemically produces organic compounds that could serve as fuels or as a useful intermediary to more beneficial compounds; and an electrochemical hydrogen separator and compressor for hydrogen recycle. The technical maturity of these projects is presented along with pertinent performance test data that could be beneficial in future study efforts.

Roy, Robert J.↗

Performance, reliability and life issues for components of the Planck Sorption Cooler

Continuous-duty hydrogen sorption cryocoolers are being developed for the European Space Agency (ESA) Planck mission. To achieve an acceptable level of performance and robust operation with these hydride refrigerators during flight, detailed investigations have been performed on the sorbent materials and on critical hardware components.

sorption↗

Random Vibration Simulation and Testing of a Compact, Magnetic Bearing Supported Blower for Space Applications

NASA is developing a next-generation CO2 removal system, the Four Bed Carbon Dioxide Scrubber (4BCO2), which will use the International Space Station (ISS) as a testbed. A key component of both the existing and the new system is the blower that provides the airflow through the CO2 sorbent beds. To improve performance and reliability, magnetic bearings will be used in lieu of more conventional bearings (e.g. ball bearings or hydrodynamicbearings) to improve resistance to contaminants and enable extensibility with regards to blower speed, pressure rise and mass flow rate. The new blower features a high-efficiency permanent magnet motor, a five-axis, active magnetic bearing system, and a compact controller containing both a variable speed drive and magnetic bearing controller. The blower uses a centrifugal impeller to pull air from the inlet port and drive it through an annular space around the motor and magnetic bearing components to the exhaust port. Technical challenges of the blower and controller development include survival of the blower system under launch random vibration loads, operation in microgravity, packaging under strict size and weight requirements, and successful operation during 4BCO2 operational changeovers. Each serial build of the blower must pass a severe random vibration test to prove it will survive launch conditions. This paper discusses the vibration test requirements and provides details of a simulation performed to estimate the peak backup bearing displacements and loads. Results from the successful random vibration testing of the prototype build are discussed and compared to the simulation.

bearings↗