Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Room temperature electron transport properties of single C{sub 60} studied using scanning tunneling microscope and reak junctions.

We report the measurements of the electron transport of an individual C{sub 60} molecule through the combination of two experimental efforts. The nanometer-sized junctions were fabricated using electromigration combined with electron beam lithography and shadow effect evaporation. We performed the scanning tunneling microscopy/spectroscopy measurements of dispersed C{sub 60} molecules which were deposited on a highly ordered pyrolytic graphite substrate. The single electron tunneling through a single C{sub 60} molecule due to the Coulomb blockage effect is observed at room temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Final Report – Study of Shortwave Spectra in Fully 3D Environment. Synergy Between Scanning Radars and Spectral Radiation Measurements

ARM set out 20 years ago to “close” the radiation problem, that is, to improve radiation models to the point where they could routinely predict the observed spectral radiation fluxes knowing the optical properties of the surface and of gases, clouds and aerosols in the atmosphere. Only then could such radiation models form a proper springboard for global climate model (GCM) parameterizations of spectral radiation. Sustained efforts have more or less achieved that goal with regard to longwave radiation; ASR models now routinely predict ARM spectral longwave radiances to 1–2%. Similar efforts in the shortwave have achieved far less; the successes are mainly for carefully selected 1D stratiform cloud cases. Such cases amount, even with the most optimistic interpretation, to no more than 30% of all cases at SGP. The problem has not been lack of effort but lack of appropriate instruments.The new ARM stimulus-funded instruments, with their new capabilities, will dramatically improve this situation and once again make progress possible on the shortwave problem. The new shortwave spectrometers will provide a reliable, calibrated record including the near infrared – and for other climatic regimes than SGP. The new scanning radars will provide the 3D cloud view, making it possible to tackle fully 3D situations. Thus, our main theme for the project is the understanding and closure of the surface spectral shortwave radiation problem in fully 3D cloud situations by combining the new ARM scanning radars and shortwave spectrometers with the arsenal of radiative transfer tools.

54 ENVIRONMENTAL SCIENCES↗

An evaluation of selected NASA scientific and technical information products: Results of a pilot study

A pilot study was conducted to evaluate selected NASA scientific and technical information (STI) products. The study, which utilized survey research in the form of a self-administered mail questionnaire, had a two-fold purpose -- to gather baseline data regarding the use and perceived usefulness of selected NASA STI products and to develop/validate questions that could be used in a future study concerned with the role of the U.S. government technical report in aeronautics. The sample frame consisted of 25,000 members of the American Institute of Aeronautics and Astronautics in the U.S. with academic, government or industrial affiliation. Simple random sampling was used to select 2000 individuals to participate in the study. Three hundred fifty-three usable questionnaires (17 percent response rate) were received by the established cutoff date. The findings indicate that: (1) NASA STI is used and is generally perceived as being important; (2) the use rate for NASA-authored conference/meeting papers, journal articles, and technical reports is fairly uniform; (3) a considerable number of respondents are unfamiliar with STAR (Scientific and Technical Aerospace Reports), IAA (International Aerospace Abstracts), SCAN (Selected Current Aerospace Notices), and the RECON on-line retrieval system; (4) a considerable number of respondents who are familiar with these media do not use them; and (5) the perceived quality of NASA-authored journal articles and technical reports is very good.

Pinelli, Thomas E.↗

LDEF polymeric materials: 10 months versus 5.8 years of exposure

The chemical characterization of several polymeric materials which received 10 months of exposure and 5.8 years of exposure on a Row 9 Long Duration Exposure Facility (LDEF) experiment (A0134) is reported. Specimens include fluorinated ethylene propylene (FEP) teflon film, polysulfone film, and graphite fiber reinforced epoxy amd polysulfone matrix composites. The responses of these materials to the two LEO exposures are compared. The results of infrared, thermal, x-ray photoelectron, and scanning electron microscope analyses are reported. Solution property measurements of various molecular weight parameters are presented for the thermoplastic polysulfone materials. Molecular level effects attributable to exposure that were present in 10-month exposed specimens were not found in 5.8-year exposed specimens. This result suggests that increased atomic oxygen fluence toward the end of the LDEF mission may have eroded away selected environmentally induced changes in surface chemistry for 5.8-year exposure specimens.

Young, Philip R.↗

Results from Vernier scans during the RHIC 2008 PP Run

Using the vernier scan or Van der Meer scan technique, where one beam is swept stepwise across the other while measuring the collision rate as a function of beam displacement, the transverse beam profiles, the luminosity and the effective cross section of the detector in question can be measured. This report briefly recalls the vernier scan method and presents results from the 100 GeV 2008 RHIC polarized proton (pp) run.

43 PARTICLE ACCELERATORS↗

Performance of automatic scanning microscope for nuclear emulsion experiments

The impressive improvements in scanning technology and methods let nuclear emulsion to be used as a target in recent large experiments. We report the performance of an automatic scanning microscope for nuclear emulsion experiments. After successful calibration and alignment of the system, we have reached 99% tracking efficiency for the minimum ionizing tracks that penetrating through the emulsions films. The automatic scanning system is successfully used for the scanning of emulsion films in the OPERA experiment and plan to use for the next generation of nuclear emulsion experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of the Laser Scanning Rate on the Structure of Rotating Lattice Single Crystal Lines

Localized controlled heating of glass with a continuous wave laser has introduced the possibility of engineering the lattice of recently discovered rotating lattice single (RLS) crystals and thus obtaining novel metamaterials. On this account, we report the role of the laser scanning speed on the lattice structure of a model system: Sb 2 S 3 straight RLS crystal lines created in a 16SbI 3 -84Sb 2 S 3 glass. The electron backscatter diffraction analysis shows that above a critical laser scanning speed the lattice rotates along the direction of scanning, the rate of lattice rotation is relatively insensitive to scanning speed, and the growth front is symmetric. In contrast, for laser scanning speeds below this critical value, the rate and direction of lattice rotation are strongly affected by the speed. Further, the growth front becomes asymmetric, which promotes the formation of new grains misoriented by ≤10°. These observations are reported on in terms of the relative dominance of the temperature gradient from laser scanning vis-á-vis the intrinsic preferred crystallographic direction of crystal growth. In addition to providing guidelines for fabricating the RLS crystal of the desired rate of the lattice rotation, new insight is gained for the mechanism of plumose formation in spherulitic crystals.

36 MATERIALS SCIENCE↗

Automated All-Weather Lidar with Scanning Option

The design of the Depolarization and Backscatter Unattended Lidar (DABUL) was reported at the last ILRC. The addition of automated scanning in elevation angle within a single azimuthal plane permits more comprehensive sampling of clouds and more quantitative interpretation of the data, especially near the surface. Some highlights are described of measurements made during field tests of DABUL. Examples are also given of preliminary results from the current year-long deployment aboard a research vessel drifting in the arctic ice pack as part of the SHEBA (Surface HEat Budget of the Arctic) project and NASA's arctic cloud and satellite validation research.

Eberhard, Wynn L.↗

Soft x-ray spectromicroscopy using compact scanning transmission x-ray microscope at the photon factory

We report the stability and recent performances of a new type of scanning transmission X-ray microscopy. The optics and compact design of the microscope realized mobility and robust performance. Detailed consideration to the vibration control will be described. The insertion device upgraded to elliptical polarization undulator enabled linear dichroism and circular dichroism experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Architecture for removable media USB-ARM

A storage device is coupled to a computing system comprising an operating system and application software. Access to the storage device is blocked by a kernel filter driver, except exclusive access is granted to a first anti-virus engine. The first anti-virus engine is directed to scan the storage device for malicious software and report results. Exclusive access may be granted to one or more other anti-virus engines and they may be directed to scan the storage device and report results. Approval of all or a portion of the information on the storage device is based on the results from the first anti-virus engine and the other anti-virus engines. The storage device is presented to the operating system and access is granted to the approved information. The operating system may be a Microsoft Windows operating system. The kernel filter driver and usage of anti-virus engines may be configurable by a user.

97 MATHEMATICS AND COMPUTING↗

Patient-specific dose estimation for pediatric chest CT

Current methods for organ and effective dose estimations in pediatric CT are largely patient generic. Physical phantoms and computer models have only been developed for standard/limited patient sizes at discrete ages (e.g., 0, 1, 5, 10, 15 years old) and do not reflect the variability of patient anatomy and body habitus within the same size/age group. In this investigation, full-body computer models of seven pediatric patients in the same size/protocol group (weight: 11.9-18.2 kg) were created based on the patients' actual multi-detector array CT (MDCT) data. Organs and structures in the scan coverage were individually segmented. Other organs and structures were created by morphing existing adult models (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. Organ and effective dose of these patients from a chest MDCT scan protocol (64 slice LightSpeed VCT scanner, 120 kVp, 70 or 75 mA, 0.4 s gantry rotation period, pitch of 1.375, 20 mm beam collimation, and small body scan field-of-view) was calculated using a Monte Carlo program previously developed and validated to simulate radiation transport in the same CT system. The seven patients had normalized effective dose of 3.7-5.3 mSv/100 mAs (coefficient of variation: 10.8%). Normalized lung dose and heart dose were 10.4-12.6 mGy/100 mAs and 11.2-13.3 mGy/100 mAs, respectively. Organ dose variations across the patients were generally small for large organs in the scan coverage (<7%), but large for small organs in the scan coverage (9%-18%) and for partially or indirectly exposed organs (11%-77%). Normalized effective dose correlated weakly with body weight (correlation coefficient: r=-0.80). Normalized lung dose and heart dose correlated strongly with mid-chest equivalent diameter (lung: r=-0.99, heart: r=-0.93); these strong correlation relationships can be used to estimate patient-specific organ dose for any other patient in the same size/protocol group who undergoes the chest scan. In summary, this work reported the first assessment of dose variations across pediatric CT patients in the same size/protocol group due to the variability of patient anatomy and body habitus and provided a previously unavailable method for patient-specific organ dose estimation, which will help in assessing patient risk and optimizing dose reduction strategies, including the development of scan protocols.

61 RADIATION PROTECTION AND DOSIMETRY↗

UT-GOM2-1 Hydrate Pressure Coring Expedition (Chapter 2. Expedition Methods)

This chapter documents the procedures and methods employed by the UT-GOM2-1 Expedition on the Helix D/V Q-4000 vessel; dockside at the demobilization dock, InterMoor, Port Fourchon, LA; and during subsequent limited shore-based analyses. Dockside analyses reported here include continued pressure core logging, curation, quantitative degassing, gas analysis, and mud lab activities. The limited shore-based analyses reported here include initial core scanning and core description at Ohio State University, smear slide and visual descriptions at the University of New Hampshire, and geochemical analyses at the University of Washington. All work discussed was completed between June and September 2017. Future shore-based analyses of UT GOM2-01 results will be described in separate individual publications. This expedition report is modeled after the reporting style of the International Ocean Discovery Program (IODP). The methods used during the expedition were designed to conform to IODP protocols as much as possible.

03 NATURAL GAS↗

Advanced detector signal acquisition and electron beam scanning for high resolution SEM imaging

We report the advancement of materials science at the mesoscale requires improvements in both sampling volumes/areas and spatial resolution in order to make statistically significant measurements of microstructures that influence higher-order material properties, such as fatigue and fracture. Therefore, SEM-based techniques have become desirable due to improvements in imaging resolution, large sample handling capability, and flexibility for in-situ instrumentation. By using fast sampling of SEM electron detector signals, intrinsic beam scanning defects have been identified that are related to the response time of the SEM electron beam deflectors and electron detectors. Mitigation of these beam scanning defects using detector sampling approaches and an adaptive model for settling time is shown to produce higher resolution SEM images, at faster image acquisition times, with a means to quantify the different response functions for various beam deflectors and detectors including those for electrons and ions.

47 OTHER INSTRUMENTATION↗

Defect-induced displacement of topological surface state in quantum magnet MnBi2Te4

The topological magnet MnBi2⁢Te4 (MBT), with gapped topological surface state, is an attractive platform for realizing quantum anomalous Hall and axion insulator states. However, the experimentally observed surface state gaps fail to meet theoretical predictions, although the exact mechanism behind the gap suppression has been debated. Recent theoretical studies suggest that intrinsic antisite defects push the topological surface state away from the MBT surface, closing its gap and making it less accessible to scanning probe experiments. Here, we report on the local effect of defects on the MBT surface states and demonstrate that high defect concentrations lead to a displacement of the surface states well into the MBT crystal, validating the theorized mechanism. The local and global influence of antisite defects on the topological surface states are studied with samples of varying defect densities by combining scanning tunneling microscopy, angle-resolved photoemission spectroscopy, and density functional theory. Our findings identify a combination of increased defect density and reduced defect spacing as the primary factors underlying the displacement of the surface states and suppression of surface gap, guiding further development of topological quantum materials.

Lupke, Felix [Carnegie Mellon University (CMU)]↗

Improvements in the orbitalwise scaling down of Perdew–Zunger self-interaction correction in many-electron regions

The Perdew-Zunger (PZ) method offers a way to remove the self-interaction (SI) error from density functional approximations on an orbital by orbital basis. The PZ method provides significant improvements for the properties such as barrier heights or dissociation energies but results in over-correcting the properties well described by SI-uncorrected semi-local functional. One cure to rectify the over-correcting tendency is to scale down the magnitude of SI-correction of each orbital in the many electron region. We have implemented the orbitalwise scaled down SI-correction (OSIC) scheme of Vydrov et al. [J. Chem. Phys. 124, 094108 (2006)] using the Fermi-L owdin SI-correction method. After validating the OSIC implementation with previously reported OSICLSDA results, we examine its performance with the most successful non-empirical SCAN meta-GGA functional. Using different forms of scaling factors to identify one-electron regions, we assess the performance of OSIC-SCAN for a wide range of properties: total energies, ionization potentials and electron affinities for atoms, atomization energies, dissociation and reaction energies, and reaction barrier heights of molecules. Our results show that OSIC-SCAN provides superior results than the previously reported OSIC-LSDA, -PBE, and -TPSS results. Furthermore, we propose selective scaling of OSIC (SOSIC) to remove its major shortcoming that destroys the -1/r asymptotic behavior of the potentials. The SOSIC method gives the highest occupied orbital eigenvalues practically identical to those in PZSIC and unlike OSIC provides bound atomic anions even with larger powers of scaling factors. Furthermore, SOSIC compared to PZSIC or OSIC provides more balanced description of total energies and barrier heights.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Construction of meta-GGA functionals through restoration of exact constraint adherence to regularized SCAN functionals

The strongly constrained and appropriately normed (SCAN) meta-GGA exchange–correlation functional is constructed as a chemical environment-determined interpolation between two separate energy densities: one describes single-orbital electron densities accurately and another describes slowly varying densities accurately. To conserve constraints known for the exact exchange–correlation functional, the derivatives of this interpolation vanish in the slowly varying limit. While theoretically convenient, this choice introduces numerical challenges that degrade the functional’s efficiency. We have recently reported a modification to the SCAN meta-GGA, termed restored-regularized-SCAN (r 2 SCAN) , that introduces two regularizations into SCAN, which improve its numerical performance at the expense of not recovering the fourth order term of the slowly varying density gradient expansion for exchange. Here, we show the derivation of a progression of density functional approximations [regularized SCAN (rSCAN), r++SCAN, r 2 SCAN, and r 4 SCAN] with increasing adherence to exact conditions while maintaining a smooth interpolation. The greater smoothness of r 2 SCAN seems to lead to better general accuracy than the additional exact constraint of SCAN or r 4 SCAN does.

, correlation energy↗

Sunspot bright rings and the thermal diffusivity of solar convection

Raster-scan observations of 10 sunspots, made in 1980 and 1981 with the 512-channel diode array and vacuum telescope at the Kitt Peak National Observatory, are reported. Data from several 10-min scans of 0.25-A passbands of clean continuum were summed to give an rms noise level of 0.25 percent, corrected by applying a limb-darkening curve, and analyzed to determine the average intensity for each of eight segments of a series of concentric rings around each sunspot. Faculae and pores were identified and discarded in constructing radial intensity profiles. Marginally significant bright symmetric rings (peak amplitude 0.1-0.3 percent) not attributable to residual facular signal or instrumental effects were observed around 6 of 10 sunspots. No evidence of more intense bright rings was found. These findings are discussed in terms of thermal-diffusion models proposed to explain the fate of the radiative flux blocked by sunspots.

Duvall, T., Jr.↗