Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampled value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Determination of acoustic nonlinearity parameters using thermal modulation of ultrasonic waves

This study presents a test method and its theoretical framework to determine the acoustic nonlinearity parameters (α, β, δ) of material using thermal modulation of ultrasonic waves. Temperature change-induced thermal strain excites the nonlinear response of the material and modulates the ultrasonic wave propagating in it. Experimental results showed a strong correlation between the relative wave velocity change and the temperature change. With a quadratic polynomial model, the acoustic nonlinearity parameters were obtained from the polynomial coefficients by curve fitting the experimental data. Their effects on thermal-induced velocity change were discussed. The parameters α, β, and δ govern the hysteretic gap, average slope, and curvature of the correlation curve, respectively. The proposed theory was validated on aluminum, steel, intact and damaged concrete samples. The obtained nonlinear parameters show reasonable agreement with values reported in the literature. Compared to other nonlinear acoustic methods using vibration or acoustic excitation, the thermal modulation method generates more uniform, slow changing, and larger strain field in the test sample. Employing the thermal effect as the driving force for nonlinearity instead of an undesired influencing factor, this method can measure the absolute values of α, β, and δ with good accuracy using a simple ultrasonic test setup.

Physics↗

On the dark matter haloes of optical and IR-selected AGNs in the local universe

ABSTRACT We use the technique of total satellite luminosity, Lsat, to probe the dark matter haloes around active galactic nuclei (AGNs) in the SDSS Main Galaxy Sample. Our results focus on galaxies and AGNs that are the central galaxy of their halo. Our two AGN samples are constructed from optical emission-line diagnostics and from Wide-Field Infrared Survey Explorer (WISE) infrared colours. Both optically selected and WISE-selected AGN have Lsat values twice as high as non-active galaxy samples when controlling for stellar mass and mean stellar age. This implies that the haloes are twice as massive, but we cannot rule out that the increase in Lsat is due to these AGNs residing in younger haloes at the same mass. When only controlling for host galaxy stellar mass, WISE-selected AGNs also have higher Lsat values than optical AGNs at the factor of two level, consistent with previous results comparing the clustering of obscured and unobscured AGNs. However, controlling for stellar age in the two populations of host galaxies removes half of this difference, attenuating the statistical significance of the difference. We perform permutation tests to quantify the difference in the halo populations of each sample. The difference in star formation properties does not fully explain the difference in the two AGN populations, however. Although AGN luminosity correlates with mean stellar age, the difference in stellar age between the WISE and optical samples cannot be fully explained by differences in their AGN luminosity distributions.

Alpaslan, Mehmet (ORCID:0000000303211033)↗

Surface Water Quality Data from Beaver-Impacted Streams; Trail Creek and East River, Colorado 2025

This data package contains surface water chemistry measurements collected in 2025 to evaluate how beaver damming and low-tech process-based stream restoration influence water quality and metal mobility in mountainous headwater systems of the Upper Colorado River Basin. Sampling was conducted at Trail Creek (Taylor Park watershed, Colorado), a tributary undergoing restoration through installation of low-tech process-based structures (i.e., beaver dam analogs), and at off-channel beaver ponds within the East River floodplain (East River watershed, Colorado). Samples were collected along longitudinal transects spanning upstream control reaches, beaver-influenced ponded reaches, and downstream segments. Additional samples were collected from near-surface pore waters within a beaver dam seepage face. The dataset includes concentrations of major and trace elements measured by inductively coupled plasma–mass spectrometry (ICP-MS) and inductively coupled plasma–optical emission spectrometry (ICP-OES), major anions measured by ion chromatography (IC), and dissolved organic carbon (DOC; reported as non-purgeable organic carbon, NPOC). Samples were size-fractionated at 0.45 micrometers (µm), 0.22 µm, and 0.02 µm to distinguish particulate (>0.45 µm), colloidal (0.22–0.02 µm), and dissolved (<0.02 µm) fractions. The data package consists of comma-separated value (.csv) files containing tabulated chemical concentration data, sample metadata (site identifiers, geographic coordinates, sampling dates, fraction type), and quality control flags. All files are provided in open, non-proprietary formats that can be accessed using standard data analysis software such as Microsoft Excel, R, Python, MATLAB, or other programs capable of reading .csv files. Units, detection limits, and analytical methods are documented in accompanying metadata files. The dataset is designed to support analyses of (1) how beaver impoundment and restoration structures alter elemental partitioning and transport, (2) the role of iron and organic carbon in mediating trace metal mobility, and (3) reach-scale changes in water quality across restoration gradients. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. Part of this work was performed at SLAC Accelerator Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-76SF00515.

Anions↗

Performance of a MQXF Nb 3 Sn Quadrupole Magnet Under Different Stress Level

In a dipole or in a quadrupole accelerator magnet, the displacement of the coil turns induced by the electromagnetic forces can cause quenches limiting the magnet performance. For this reason, an azimuthal preload is applied to avoid azimuthal movements of the coil up to the required operational current. However, several tests showed that accelerator magnets can operate with a partial preload, i.e. that coil unloading during the ramp does not prevent reaching higher currents. This issue is particularly relevant for Nb 3 Sn magnets, where the loads applied to the Nb3Sn filaments can reach the degradation limits of critical current. In order to investigate the impact of coil preload on the quench performance, the MQXFS6 short model quadrupole for the High Luminosity Upgrade was tested under an azimuthal preload at 80% of the short sample current, reaching 93% of short sample current at 1.9 K. The preload was then released to 60%, still showing ability to operate in the range of 80-85% of short sample current as required by HL-LHC project. With this lower preload, the ability of going above 90% of short sample was lost, and a significant training appeared above 85%. When the preload was restored to the original 80% value, the magnet reached with few quenches 95% of short sample (13.4 T peak field). Magnetic measurements confirm the larger movement of the coil in the case with lower preload, and agree with finite element simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measuring Signatures of Fuel Irradiation in Large Particle Samples

Understanding the operating history of a nuclear facility is one of the key goals in nuclear safeguards, enabling the verification of declared activities. This is accomplished via a number of mechanisms, including the analysis of samples collected at the facility. The best metrics for understanding and verifying the history of nuclear fuel are (1) actinide isotopic content and (2) actinide inter-element ratios. While techniques have long existed for measuring these values with high accuracy and precision in bulk samples, as samples become smaller – such as may be collected in environmental collection – new methods are required both for clean processing of pure samples, and for analysis of these small samples. This study describes a new extraction chromatography technique for recovering U, Pu, and Am from single small aliquots, and advanced mass spectrometry methods for high-precision and high-accuracy analysis of trace and ultra-trace levels of actinides. These techniques are applied to particle samples cut from fuel from a historic nuclear reactor. Ages calculated from Pu–Am chronometry of particles are in excellent agreement with the known operating history of the reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Retrieved Number concentration of Cloud Condensation Nuclei (RNCCN) Value-Added Product (VAP)

The objective of Retrieved Number concentration of Cloud Condensation Nuclei (RNCCN) Value-Added Product (VAP) is to provide the vertical distribution of cloud condensation nuclei (CCN) number concentrations to better represent aerosol indirect effects in climate models. The RNCCN VAP allows to collect a large number of independent samples of vertical CCN measurements at various supersaturation values from the ground. This helps to avoid the high cost of aircraft and increases the temporal distribution of retrieved CCN in the planetary boundary layer. The VAP method is based on Ghan and Collins (2004) and Ghan et al. (2006) proposed parameterizations that retrieve the vertical profiles of CCN directly from the ground level CCN, humidification factor, and in-situ lidar measurements. Further, the VAP accuracy is improved by using the quality controlled data that ensures that the boundary layer is well mixed.

54 ENVIRONMENTAL SCIENCES↗

VADER: A Tool for Criticality Safety Validation

The purpose of criticality safety is to prevent any inadvertent criticality from occurring during the handling or storage of fissile material. Calculations are frequently used to demonstrate that a sufficient subcritical margin exists. Validation is a key aspect of the evaluation process, establishing the suitability, accuracy, and associated uncertainty of the computational method and data to be used for the intended application. The validation process is performed by comparing the results of critical experiments with the calculated results from models of the experiments using the computational method to be validated. Laboratory critical experiments are controlled systems that achieve a k eff of approximately 1 in order to investigate the parameters at which such a critical condition is achieved. The validation parameters that are traditionally applied to safety analysis calculations are the bias and the bias uncertainty . The bias is the deviation of the average k eff of the validation suite from unity. The bias uncertainty accounts for the statistical uncertainty in the bias based on the standard deviation, sample size, and distribution of k eff values of the validation suite. The values of bias and bias uncertainty ensure that the systems predicted to be subcritical by the computational method will indeed be subcritical. The bias and bias uncertainty are often combined to determine an upper subcritical limit (USL) or computational margin that can then be applied to safety analysis calculations. Many methods have been developed by different organizations to calculate the bias and bias uncertainty for various types of criticality analyses. Each of these methods typically requires that the validity of various underpinning statistical assumptions be confirmed to demonstrate that the method is appropriate for the analysis of a given validation suite. An example of the validation decision making flow is shown in Fig.1. As shown in Fig. 1, the analyst performing the validation fits a trend line to the data and performs a test to determine if the trend was a statistically better representation of the data than if it were treated as an uncorrelated sample. If the trend line is a better representation of the data, then the analyst uses any one of a number of trending techniques to determine the bias and bias uncertainty. If a trend is not an appropriate representation of the data, then the analyst proceeds to perform a normality assessment for the data. If the normal assumption can be shown to be acceptable, then the analyst calculates the bias and bias uncertainty with the parametric technique. If the assumption of normality cannot be justified, then the nonparametric technique is used. Once the decision flow has been followed and the appropriate technique has been selected, the bias and bias uncertainty is typically combined with an administrative margin to determine a USL below which calculated values of k eff for safety analysis models can be considered subcritical. The calculations used in each decision are often performed with spreadsheets or with small programs available at various sites performing criticality analyses. Expertise in understanding and interpreting the results must be maintained to perform these calculations. This can often be an error-prone process. Oak Ridge National Laboratory (ORNL) is currently developing the Validation and Data Evaluation Resource (VADER) to simplify and automate the criticality safety validation process and to provide a software quality assurance pedigree to the calculational methods used. This paper discusses the use of the Fulcrum user interface with VADER, the anticipated initial capabilities of VADER to perform validation analyses, and the output from the code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Empirical Quantile Estimation Approach for Chance-Constrained Nonlinear Optimization Problems

We investigate an empirical quantile estimation approach to solve chance-constrained nonlinear optimization problems. Our approach is based on the reformulation of the chance constraint as an equivalent quantile constraint to provide stronger signals on the gradient. In this approach, the value of the quantile function is estimated empirically from samples drawn from the random parameters, and the gradient of the quantile function is estimated via a finite-difference approximation on top of the quantile-function-value estimation. We establish a convergence theory of this approach within the framework of an augmented Lagrangian method for solving general nonlinear constrained optimization problems. The foundation of the convergence analysis is a concentration property of the empirical quantile process, and the analysis is divided based on whether or not the quantile function is differentiable. In contrast to the sampling-and-smoothing approach used in the literature, the method developed in this paper does not involve any smoothing function and hence the quantile-function gradient approximation is easier to implement and there are less accuracy-control parameters to tune. Furthermore, we demonstrate the effectiveness of this approach and compare it with a smoothing method for the quantile-gradient estimation. Numerical investigation shows that the two approaches are competitive for certain problem instances.

Applied Probability↗

Total Dissolved Nitrogen and Ammonia Data for the East River Watershed, Colorado (2015-2025)

This data package contains mean values for total dissolved nitrogen (TDN) and ammonia concentrations for water samples taken from the East River Watershed in Colorado. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. TDN was analyzed using a Shimadzu Total Nitrogen Module (TNM-1) combined with the TOC-VCSH analyzer (Shimadzu Corporation, Japan). TNM-1 is a non-specific measurement of total nitrogen (TN). All nitrogen species in samples are combusted to nitrogen monoxide and nitrogen dioxide, then reacted with ozone to form an excited state of nitrogen dioxide. Upon returning to ground state, light energy is emitted. Then, TDN is measured using a chemiluminescence detector. Ammonia was determined using a Lachat's QuikChem 8500 Series 2 Flow Injection Analysis System (LACHAT Instruments, QuckChem 8500 series 2, Automated Ion Analyzer, Loveland, Colorado). When ammonia in water samples is heated (60 degrees C) with salicylate and hypochlorite in an alkaline phosphate buffer, an emerald green color is produced which is proportional to the ammonia concentration. The color is intensified by the addition of nitroprusside. Ethylenediaminetetraacetic acid (EDTA) is added to the buffer to prevent the interference of metal ions (Ca, Mg, and Fe etc.). Ammonia-N is then determined by LACHAT flow injection and a colorimetric assay at an absorbance wavelength 660 nm. (Reference: LACHAT Instruments: QuickChem Method 90-107-06-3-A, Determination of Ammonia by Flow Injection Analysis (High Throughput, Salicylate Method/DCIC) (Multi Matrix method). Written by Lynn Egan (Application group), February 08, 2011.) All files are labeled by location and variable, and data reported are the mean values upon replicate measurements. All samples were analyzed under a rigorous quality assurance and quality control (QA/QC) process as detailed in the methods. This data package contains (1) a zip file (tdn_ammonia_data_2015-2025.zip) containing a total of 299 files: 298 data files of ammonia and TDN data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v7_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v7_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the determination of Method Detection Limits (MDLs) for TDN data, which has been updated in 2026-08; and (5) PDF and docx files for the detemination of Method Detection Limits (MDLs) for Ammonia and the Interferences by LACHAT Flow Injection Analysis. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 105 locations containing TDN and Ammonia-N data. Update 2020-10-07: Updated the data files to remove times from the timestamps, so that only dates remain. The data values have not changed. Update 2021-04-11: Added Determination of Method Detection Limits (MDLs) for DIC, NPOC and TDN Analyses and Determination of Method Detection Limit for Ammonia and the Interferences by LACHAT Flow Injection Analysis documents, which can be accessed as PDFs or with Microsoft Word.Update on 6/10/2022: versioned updates to this dataset was made along with these changes: (1) updated total dissolved nitrogen and ammonia data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) restructure of units to comply with CSV reporting format requirements, (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2022-12-20: Updates were made to both the data files and reporting format specific files. Units were listed incorrectly, but have been fixed to reflect correct units (ug/L). File level metadata (flmd) and data dictionary (dd) files were updated to reflect the updated versions of these files. Available data was added up until 2022-06-01. Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-27. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Revised versions of the PDF and docx files for determination of MDLs for TDN were added to replace previous versions. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-10, of the PDF and docx files for determination of MDLs for TDN data were added to this dataset.

54 ENVIRONMENTAL SCIENCES↗

Detecting differential protein abundance by combining peptide level P -values

The majority of methods for detecting differentially abundant proteins between samples in label-free LC-MS bottom-up proteomics experiments rely on statistically testing inferred protein abundances derived from peptide ionization intensities or averaging peptide level statistics. Here in this paper, we statistically test peptide ionization intensities directly and combine the resulting dependent P-values using the Empirical Brown's Method (EBM), avoiding error introduced through the estimation of protein abundances or summarizing test statistics. We show that on a spike-in proteomics dataset, a peptide level approach using EBM outperforms differential abundance detection using a protein level approach and several analysis workflows, including MSstats. Additionally, we demonstrate the effectiveness of this approach by detecting enriched proteins from an activity-based protein profiling dataset.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of HRGS for forensic characterization of uranium oxides, pure uranium metals and uranium alloys

A nondestructive iterative method for uranium-bearing material characterization with HRGS developed earlier in (J. appl. Rad. Isotopes, 166 (2020) 109433) is applied to determine matrix densities and uranium isotope masses of a variety of uranium materials, namely uranium ore, UO 2 and U 3 O 8 powders, fuel elements in the form of UO2 microspheres, uranium metal and uranium alloys. It is shown that U 3 O 8 powders with uranium mass fraction of about 84% can be distinguished from the powders of UO 2 with uranium mass fraction of about 87%; uranium products in the form of liquid or loose powder with matrix density of 0.5-2.0 g/cm 3 can be distinguished from uranium products in the form of compacted fuel elements with matrix density of 6.0-10.0 g/cm 3 and from pure metal uranium and uranium alloys with matrix density of 14.0- 19.0 g/cm 3 . In fuel microspheres based on UO2 the uranium mass fraction 88.02% measured by HRGS is consistent, within the measurement uncertainties, with the results of isotope dilution mass spectrometry 87.76±0.64 % and also is confirmed by X-ray diffraction technique. The uranium mass fraction of the uranium ore estimated as 0.08% by HRGS is consistent, within the measurement uncertainties, with the value 0.09±0.01% determined with WDXRF. Densities of two different uranium metal samples, estimated as 18.42 g/cm 3 and 19.33 g/cm 3 by HRGS are consistent with values 18.24±0.55 g/cm 3 and 18.86±0.59 g/cm 3 , respectively, obtained by the gas pycnometry technique.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rice Bran Stabilisation and Oil Extraction Using the Microwave-Assisted Method and Its Effects on GABA and Gamma-Oryzanol Compounds

Rice bran oil (RBO) is a valuable ingredient extracted from rice bran (RB), a side stream of polishing rice grain in the milling process. RBO is rich in bioactive ingredients with potential health benefits, such as gamma-oryzanol (GO) and gamma-aminobutyric acid (GABA). Despite its benefits, the quality of RBO depends on the degree of stabilisation of the RB, which is easily affected by lipase enzymes, and thus needs an effective treatment prior to RBO production. To assess the potential of the microwave-assisted method for RB stabilisation and RBO extraction, three Carolino rice varieties (Ariete, Teti, Luna) were tested. The effect of RB stabilisation was evaluated via acid value, water absorption, and GO and GABA levels. The RBO yield was optimised by solvent, temperature, and solvent-to-sample ratio, and the GO and fatty acid levels were determined. The RB stabilisation for the Luna variety did not affect the GO and GABA; for the Ariete and Teti varieties, the GO decreased by 34.4% and 24.2%, and the GABA increased by 26.5% and 47.0%, respectively. The GO levels in RBO samples were not affected by RB stabilisation. The RBO nutritional value was confirmed by the suitable ratio (>2) between polyunsaturated (PUFA) and saturated fatty acids (SFA), with the Teti variety presenting the highest ratio.

Reis, Núria (ORCID:0000000194339109)↗

SAIL-Isotopologue (SAIL-iso) Field Campaign Report

The SAIL-iso project took place from November 19, 2022 to June 3, 2023 as part of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Surface Atmosphere Integrated Field Laboratory (SAIL) project at the main project site in Gothic, Colorado. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in a remote mountainous watershed. Water vapor isotopologue and humidity measurements were determined using a Los Gatos Research Triple Water Vapor Isotope Analyzer (TWVIA). The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through Teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. Multiple sources of uncertainty are introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) Vienna Standard Mean Ocean Water – Standard Light Antarctic Precipitation (VSMOW-SLAP) calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ 18 O.

54 ENVIRONMENTAL SCIENCES↗

Water vapor isotopic composition during TRACER IOP

The TRACER-Iso project took place from June 1 to September 30, 2022 as part of the intensive observation period (IOP) of the Tracking Aerosol Convection Interactions (TRACER) project at the main project site at the La Porte, Texas, municipal airport. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in deep convection in a polluted urban setting. Water vapor isotopologue and humidity measurements were determined using a Picarro L2130 Water Vapor Isotope Analyzer. The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, and a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. There are multiple sources of uncertainty introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) VSMOW-SLAP calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ18O.

54 ENVIRONMENTAL SCIENCES↗

Determination of transition metal ions in fossil fuel associated wastewaters using chelation ion chromatography

Here, this study outlines the development and subsequent validation of a method using chelation ion chromatography (CIC) pretreatment followed by traditional ion chromatography (IC) and post column UV/vis detection to measure transition metals in fossil fuel wastewaters, such as oil &amp; gas (O&G) brines and coal mine drainage (CMD) waters. Measurement of transition metals is often an important characterization step in the research of environmental and energy systems. IC represents one way to measure these metals with the advantages of being versatile, simple and relatively low cost compared to other analytical methods. However, high concentrations of alkali and alkaline earth metals present in fossil fuel wastewaters will decrease IC detectability of transition metals in these waters. In this study, a CIC method was developed for the analysis of transition metal ions (Fe 3+ , Cu 2+ , Ni 2+ , Zn 2+ , Co 2+ , Mn 2+ , and Fe 2+ ) in fossil fuel associated wastewaters such as Appalachian CMD and O&G wastewaters from the Permian and Bakken shale basins in the United States. CIC system incorporated an on-line chelator column (e.g., the MetPac CC-1) with high selectivity for transition metals over alkali and alkaline earth metals for salt matrix removal prior to transition metal separation and detection. Additional method developments also included acidifying all samples to 2% v/v HCl and using gradient elution rather than isocratic. The recoverability of transition metals in simple salt solutions commonly found in CMD and brine samples (e.g. NaCl, Na 2 SO 4 , CaCl 2 ) using CIC was evaluated and compared to that using traditional IC. Our results found that the CIC system significantly improved transition metal recoveries for samples in 10,000 mg/L CaCl 2 matrix, reaching 87%-108% recovery for all analytes, as opposed to 2-323% recovery in traditional IC. The limits of detection in this study achieved 10.09 – 161.2 μg/L, comparable to reported values in similar IC studies. The developed method was also verified with certified water samples, resulting in 89% - 111% recoveries in samples with higher analyte concentrations (i.e. >4x the LoDs). The developed method achieved 87% -112% recoveries for most analytes in CMD samples and 72%-138% recoveries for Bakken shale samples, relative to ICP-MS values. Overall, the current IC method can be a very good screening tool for fast and cheap analysis for transition metals at mg/L level, to facilitate selection of samples for more detailed ICP-MS analysis.

01 COAL, LIGNITE, AND PEAT↗

Proof-of-concept chemometric approach for environmental forensic sourcing of crude oil samples using SPME-GC-MS

Environmental exposure to crude oil through seepage and spillage poses risks to the immediate environment and the broader ecosystem as areas along the oil distribution path are affected by the influx of crude petroleum as well as the environmental, economic, and civil unrest that accompanies it. There is a large financial burden associated with the lost resources, including the cost of rehabilitation, and the affected sources of revenue for communities affected by oil spills. As such, it is crucial to determine the responsible parties. This work outlines an environmental forensics approach to determining the source of an un-weathered crude oil sample. The researchers employed solid phase microextraction coupled with gas chromatography mass spectrometry (SPME-GC-MS) to capture and analyze the gaseous components emitted by crude oil samples sourced from five locations. Samples were analyzed using Spearman's rank correlation and 3D covariance analysis. Both chemometric approaches yielded optimal performance results with no misclassifications, true positive rate (TPR) = 100 % and false positive rate (FPR) = 0 %. The similarity metrics calculated by each test noted clear delineations between the values of same-source and differently sourced samples. The Spearman's rank correlation test and 3D covariance calculations both demonstrated the ability to correctly identify sample source origin in this dataset. Finally, the authors outline an approach to the future application of these tests and suggest their joint use in future crude oil sourcing endeavors.

3D covariance mapping↗

Wide bandgap photoconductor (SiC:V)-based optically addressed light valve for high fluence operation

Optically addressable light valves based on wide bandgap 4H- and 6H-SiC as photoconductors were designed to withstand higher operational laser fluences than the state of-the-art bismuth silicon oxide (BSO; Bi 12 SiO 20 ) based devices. Vanadium-doped SiC was selected as the photoconductors due to their reasonable photoresponsivity while many fold improvement in laser induced damage threshold as compared to BSO. The laser induced damage threshold values of the materials were measured after exposing ~ 200 sites on the samples to increasing levels of fluence of a gaussian pulsed Nd: YAG laser system (1064 nm) with a 5 Hz repetition rate. The measured damage threshold values for BSO, 4H- and 6H-SiC were 0.4 J/cm 2 , 1.75 J/cm 2 and 1.8 J/cm 2 , respectively. Photoconductive switches based on 4H and 6H-SiC samples were characterized at wavelengths of 380 nm, 405 nm, and 447 nm. The peak photoresponsivity values of the 4H- and 6H-SiC materials were measured to be under 380 nm and 405 nm, respectively. The photoconductor was bonded to a BK7 optical window with 5 μm diameter microspheres as spacers. A twisted nematic type E7 liquid crystal (LC) was filled in the 5 μm gap in a vacuum chamber. The desired alignment of the liquid crystal was achieved by mutually orthogonal orientation of LC alignment layers on the two mating faces (SiC and BK7). The fabricated devices were modulated using address beams of wavelengths 380 nm, 405 nm, and 447 nm. In conclusion, required transmission levels of > 90% was achieved for the fabricated OALVs for a sinusoidal voltage waveform that meets the lifetime requirement of the device.

36 MATERIALS SCIENCE↗

Microstructure development and properties of micro-alloyed copper, Cu-0.3Zr-0.15Ag, produced by electron beam additive manufacturing

A micro-alloyed copper powder, Cu-0.3Zr-0.15Ag wt.%, was produced using gas atomization reaction synthesis. Zirconium was added to copper to sequester the oxygen present as copper oxide surface films on the powder particles. The as-received powders, as well as the intentionally oxidized powders were used to fabricate solid test articles by electron beam powder bed fusion additive manufacturing. Dense samples fabricated from as-received powder demonstrated nominal UTS, yield, and elongation values at 260 MPa, 150 MPa, and 34%, respectively. The average electrical conductivity of these samples was measured at 95% of the international annealed copper standard (IACS). Samples fabricated from the oxidized powder exhibited nominal UTS, yield, and elongation of 241 MPa, 146 MPa, and 43%, respectively, with an electrical conductivity of 95 % IACS. During characterization, it was observed that, rather than forming nano-scale dispersoids, the Zirconia (ZrO 2 ) appeared as discontinuous stringers in the metallographic cross-sections that crossed grain and melt pool boundaries. This was rationalized by tracing the presence of the micro-alloying addition of elemental zirconium, which was found to react with surface oxides dissociated in the melt pool to form ZrO 2 , which then solidified on the surface of the melt pool through an allotropic transformation to monoclinic ZrO 2 in discontinuous films and spheroids ranging in size from nanometers to microns. This was confirmed by microscopic analysis of the tops of the melt pools. On subsequent melt passes, these ZrO 2 structures were displaced and redistributed within the melt pool.

36 MATERIALS SCIENCE↗