Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample preparation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Effects of antimony substitution on bismuth based superconductors

The effect of Sb substitution and simultaneous substitution of Pb and Sb on the superconducting transition temperatures in the BiSrCaCuO system is investigated. The 2:2:2:3 phase is of particular interest since any small increase in the transition temperature could be of great interest. More that 90 different samples were prepared based on 2:2:2:3 stoichiometry in the BiSrCaCuO system. After this preliminary attempt, four different families of samples were investigated. In the first family of samples, Bi was substituted by Sb to form Bi(1.9)Sb(0.1)Sr2Ca2Cu3O(y). The second group of samples were prepared by simultaneous addition of Pb and Sb with nominal composition Bi(1.8)Pb(0.1)Sb(0.1)Sr2Ca2Cu3O(y). The third and fourth groups were prepared to determine the effect created when the Pb concentration is increased with the nominal compositions being Bi(1.7)Pb(0.1)Sr2Ca2Cu3O(y) and Bi(1.6)Sb(0.1)Sr2Ca2Cu3O(y). The results of these investigations are presented with a discussion.

Barrientos, Alfonso↗

Lithological maps of selected Apollo 14 Breccia samples

A booklet of mapped surfaces of some Apollo 14 samples was prepared as an intermediate step towards the preparation of a new Apollo 14 sample catalog. It contains recently obtained observations and pictures of some of the largest and less well documented Apollo breccia samples. Some of the samples (14303, 14305, 14306, and 14311) were chosen because they have large sawn surfaces. These were dusted and mapped using a binocular microscope through the window of the nitrogen cabinet.

Twedell, D. B.↗

An in Situ Technique for Elemental Analysis of Lunar Surfaces

An in situ analytical technique that can remotely determine the elemental constituents of solids has been demonstrated. Laser-Induced Breakdown Spectroscopy (LIBS) is a form of atomic emission spectroscopy in which a powerful laser pulse is focused on a solid to generate a laser spark, or microplasma. Material in the plasma is vaporized, and the resulting atoms are excited to emit light. The light is spectrally resolved to identify the emitting species. LIBS is a simple technique that can be automated for inclusion aboard a remotely operated vehicle. Since only optical access to a sample is required, areas inaccessible to a rover can be analyzed remotely. A single laser spark both vaporizes and excites the sample so that near real-time analysis (a few minutes) is possible. This technique provides simultaneous multielement detection and has good sensitivity for many elements. LIBS also eliminates the need for sample retrieval and preparation preventing possible sample contamination. These qualities make the LIBS technique uniquely suited for use in the lunar environment.

Kane, K. Y.↗

Curation of Frozen Samples

NASA's Johnson Space Center (JSC) and the Astromaterials Curator are charged by NPD 7100.10D with the curation of all of NASA s extraterrestrial samples, including those from future missions. This responsibility includes the development of new sample handling and preparation techniques; therefore, the Astromaterials Curator must begin developing procedures to preserve, prepare and ship samples at sub-freezing temperatures in order to enable future sample return missions. Such missions might include the return of future frozen samples from permanently-shadowed lunar craters, the nuclei of comets, the surface of Mars, etc. We are demonstrating the ability to curate samples under cold conditions by designing, installing and testing a cold curation glovebox. This glovebox will allow us to store, document, manipulate and subdivide frozen samples while quantifying and minimizing contamination throughout the curation process.

Fletcher, L. A.↗

Enhanced Cleaning of Genesis Solar Wind Sample 61348 for Film Residue Removal

The Genesis mission returned to Earth on September 8, 2004, experiencing a nonnominal reentry. During the recovery of the collector materials from the capsule, many of the collector fragments were placed on the adhesive protion of post-it notes to prevent the fragments from moving during transport back to Johnson Space Center. This unknowingly provided an additional contaminate that would prove difficult to remove with the limited chemistries allowed in the Genesis Curation Laboratory. Generally when collector material samples are prepared for allocation to PIs, the samples are cleaned front side only with Ultra-Pure Water (UPW) via megasonic dispersion to the collector surface to remove crash debris and contamination. While this cleaning method works well on samples that were not placed on post-its during recovery, it has caused movement of the residue on the back of the sample to be deposited on the front in at least two examples. Therefore, samples placed on the adhesive portion on post-it note, require enhanced cleaning methods since post-it residue has proved resistant to UPW cleaning.

Allums, K. K.↗

The 2009 Mars Telecom Orbiter Mission

This paper provides an overview of the Mars Telecom Orbiter (MTO) mission, and is an update to the paper presented at last year’s conference. Launched in 2009, MTO will provide Mars-to-Earth relay services for NASA missions arriving at Mars between 2010 and 2020, enabling far higher science data return and lowering the telecom and operations costs for these missions. MTO carries an optical communications payload, which will demonstrate downlink bit rates from 1 Mbps up to and possibly exceeding 30 Mbps. MTO will also demonstrate the ability to autonomously navigate, and to search for and rendezvous with an orbiting sample, in preparation for NASA’s proposed Mars Sample Return Mission. A to-be-defined science instrument will also be carried.

Boroson, Don↗

Preparation and analysis of standardized waste samples for Controlled Ecological Life Support Systems (CELSS)

The preparation and analysis of standardized waste samples for controlled ecological life support systems (CELSS) are considered. Analysis of samples from wet oxidation experiments, the development of ion chromatographic techniques utilizing conventional high pressure liquid chromatography (HPLC) equipment, and an investigation of techniques for interfacing an ion chromatograph (IC) with an inductively coupled plasma optical emission spectrometer (ICPOES) are discussed.

Carden, J. L.↗

In Situ Identification of Mineral Resources with an X-Ray-Optical "Hands-Lens" Instrument

The recognition of material resources on a planetary surface requires exploration strategies not dissimilar to those employed by early field geologists who searched for ore deposits primarily from surface clues. In order to determine the location of mineral ores or other materials, it will be necessary to characterize host terranes at regional or subregional scales. This requires geographically broad surveys in which statistically significant numbers of samples are rapidly scanned from a roving platform. To enable broad-scale, yet power-conservative planetary-surface exploration, we are developing an instrument that combines x-ray diffractometry (XRD), x-ray fluorescence spectrometry (XRF), and optical capabilities; the instrument can be deployed at the end of a rover's robotic arm, without the need for sample capture or preparation. The instrument provides XRD data for identification of mineral species and lithological types; diffractometry of minerals is conducted by ascertaining the characteristic lattice parameters or "d-spacings" of mineral compounds. D-spacings of 1.4 to 25 angstroms can be determined to include the large molecular structures of hydrated minerals such as clays. The XRF data will identify elements ranging from carbon (Atomic Number = 6) to elements as heavy as barium (Atomic Number = 56). While a sample is being x-rayed, the instrument simultaneously acquires an optical image of the sample surface at magnifications from lx to at least 50x (200x being feasible, depending on the sample surface). We believe that imaging the sample is extremely important as corroborative sample-identification data (the need for this capability having been illustrated by the experience of the Pathfinder rover). Very few geologists would rely on instrument data for sample identification without having seen the sample. Visual inspection provides critical recognition data such as texture, crystallinity, granularity, porosity, vesicularity, color, lustre, opacity, and so forth. These data can immediately distinguish sedimentary from igneous rocks, for example, and can thus eliminate geochemical or mineral ambiguities arising, say between arkose and granite. It would be important to know if the clay being analyzed was part of a uniform varve deposit laid down in a quiescent lake, or the matrix of a megabreccia diamictite deposited as a catastrophic impact ejecta blanket. The unique design of the instrument, which combines Debye-Scherrer geometry with elements of standard goniometry, negates the need for sample preparation of any kind, and thus negates the need for power-hungry and mechanically-complex sampling systems that would have to chip, crush, sieve, and mount the sample for x-ray analysis. Instead, the instrument is simply rested on the sample surface of interest (like a hand lens); the device can interrogate rough rock surfaces, coarse granular material, or fine rock flour. A breadboard version of the instrument has been deployed from the robotic arm of the Marsokhod rover in field trials at NASA Ames, where large vesicular boulders were x-rayed to demonstrate the functionality of the instrument design, and the ability of such a device to comply with constraints imposed by a roving platform. Currently under development is a flight prototype concept of this instrument that will weigh 0.3 kg, using about 4500 J of energy per sample analysis. It requires about 5 min. for XRD analysis, and about 30 min. for XRF interrogation. Its small mass and rugged design make it ideal for deployment on small rovers of the type currently envisaged for the exploration of Mars (e.g., Sojourner-scale platforms). The design utilizes a monolithic P-N junction photodiode pixel array for XRD, a Si PIN photodiode/avalanche photodiode system for XRF, and an endoscopic imaging camera system unobtrusively embedded between the detectors and the x-ray source (the endoscope with its board-mounted camera can be adapted for IR light in addition to visible wavelenths. A rugged, miniature (7 cu cm) x-ray source for the instrument has already been breadboarded.

Marshall, J.↗

Advanced Curation of Astromaterials for Planetary Science Over the Next Decade

Advanced curation is a cross-disciplinary field of research and development aiming to improve curation and sample acquisition practices in existing astromaterials collections and to enable future sample return activities.The primary result of advanced curation is to both reduce and quantify contamination to astromaterials and preserve the scientific integrity of all samples from mission inception to scientific analysis. Over the next decade, NASA should support advanced curation research and monitoring efforts as they pertain to improving our current collections and preparing for samples from current and future astromaterials acquisition activities.We highlight here five advanced curation activities of critical importance for the success of sample science supported by NASA over the coming decade, including: 1) supporting efforts to build contamination knowledge collections as part of sample return missions, which requires curation involvement from the earliest stages of sample return mission planning;2) supporting Earth-based astromaterials collection campaigns of meteorites and cosmic dust as they represent relatively inexpensive sample acquisition activities that continue to grow NASA’s astromaterials collections and enable new discoveries;3) preparing to curate and process samples under “cold” conditions to enable return of samples from volatile-rich Solar System targets like permanently shadowed regions on the lunar surface orcomets;4) determining how best to combine clean room technology and biosafety technology into one infrastructure to support curation of samples from bodies designated as Category V:Restricted Earth Return; and 5) supporting real-time monitoring and testing of curation labs to verify that sample processing environments remain clean from the standpoint of inorganic, organic, and biological contamination

Francis M. McCubbin↗

Sample Processor for Life on Icy Worlds (SPLIce): Design and Test Results

We report the design, development, and testing of the Sample Processor for Life on Icy Worlds (SPLIce) system, a microfluidic sample processor to enable autonomous detection of signatures of life and measurements of habitability parameters in Ocean Worlds. This monolithic fluid processing-and-handling system (Figure 1; mass 0.5 kg) retrieves a 50-L-volume sample and prepares it to supply a suite of detection instruments, each with unique preparation needs. SPLIce has potential applications in orbiter missions that sample ocean plumes, such as found in Saturns icy moon Enceladus, or landed missions on the surface of icy satellites, such as Jupiters moon Europa. Answering the question Are we alone in the universe? is captivating and exceptionally challenging. Even general criteria that define life very broadly include a significant role for water [1,2]. Searches for extinct or extant life therefore prioritize locations of abundant water whether in ancient (Mars), or present (Europa and Enceladus) times. Only two previous planetary missions had onboard fluid processing: the Viking Biology Experiments [3] and Phoenixs Wet Chemistry Laboratory (WCL) [4]. SPLIce differs crucially from those systems, including its capability to process and distribute L-volume samples and the integration autonomous control of a wide range of fluidic functions, including: 1) retrieval of fluid samples from an evacuated sample chamber; 2) onboard multi-year storage of dehydrated reagents; 3) integrated pressure, pH, and conductivity measurement; 4) filtration and retention of insoluble particles for microscopy; 5) dilution or vacuum-driven concentration of samples to accommodate instrument working ranges; 6) removal of gas bubbles from sample aliquots; 7) unidirectional flow (check valves); 8) active flow-path selection (solenoid-actuated valves); 9) metered pumping in 100 nL volume increments. The SPLIce manifold, made of three thermally fused layers of precision-machined cyclo-olefin polymer, supports all fluidic components (Figure 1) and integrated microchannels (125 x 250 m). Fluid is pumped by a stepper-motor-driven pump (Lee Co.). The functionality of the integrated MEMS pressure sensor (Honeywell) and passive check valves (Figure 2) were tested in conjunction with our newly designed integral bubble traps (Figure 3) and hydrophobic membrane-based concentrator (Figure 4). The concentrator (initially tested as a standalone component) demonstrated 5-fold vacuum-evaporative concentration. Polyethylene fused bead beds (PEFBBs; 50 porosity) store drylyophilized buffers, calibrants, and fluorescent dyes, and also promote mixing of sample with calibrant, dye, or H2O. Software-controlled automated tests demonstrated successful 1) fluid delivery to each component 2) valve and pump synchronization 3) sample aliquot delivery to instrument interface ports, and 4) rehydration of vacuum-dried fluorescent dye. In Figure 5, fluorescein on PEFBBs was rehydrated for 15 min using a pump-delivered water aliquot; it is displaced as H2O enters the bottom of the channel and pushes the dye into a check valve. Ultimately, SPLIce will fluorescently label amino acids in the sample for microchip-based electrophoretic (MCE) chiral separation and detection to seek and quantify key organic bio-signatures [5]; it will also deliver sample to a microfluidic version of WCL (mWCL) to measure soluble ions and redox-active species.

Life detection↗

Materials-Compliant Containers in Preparation for OSIRIS-REx Sample Return

The Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer (OSIRIS-REx) is a spacecraft that collected samples from near-Earth asteroid Bennu in 2020. NASA is expecting OSIRIS-REx to return about 250 grams of Bennu dust particles and rocky material (regolith) in the Sample Return Capsule landing on September 24, 2023.This carbonaceous material is predicted to be rich in water and organic compounds that will provide key information on the solar system's genesis. The NASA Johnson Space Center (JSC) curation team is preparing to process the returned regolith and flight hardware to support critical scientific investigations worldwide.

Curation↗

An investigation of some mechanical and thermal properties of lunar simulant materials heated at 2.45 GHz

Lunar simulant material was fabricated to simulate Apollo 11, Apollo 15, and Apollo 16 soils. The approximate compositions which these soils simulate are given. Samples of each soil simulate were fabricated into right circular cylinders, placed into a microwave reaction cavity, and heated using 2.45 GHz radiation to a particular processing temperature at which it was held for a prescribed length of time. Examples are given of two microwave heating programs for these simulant samples. Upon completion of thermal processing, each sample had its top and bottom surfaces polished. A technique was employed which looks at hardness data to determine the fracture toughness of a material and then relates this to thermal shock resistance. Some advantages of this technique are its low cost for analysis and thermal shock resistance as a function of initial sample orientation in the microwave field can be determined. Samples were prepared for testing and results are expected. At the same time, other samples are currently being investigated using scanning electron microscopy to determine their microstructures.

Meek, T. T.↗

Development of replicated optics for AXAF-1 XDA testing

Advanced optical systems for applications such as grazing incidence Wolter I x-ray mirror assemblies require extraordinary mirror surfaces in terms of fine finish and surface figure. The impeccable mirror surface is on the inside of the rotational mirror form. One practical method of producing devices with these requirements is to first fabricate an exterior surface for the optical device then replicate that surface to have the inverse component with lightweight characteristics. The replicated optic is not better than the master or mandrel from which it is made. This task identifies methods and materials for forming these extremely low roughness optical components. The objectives of this contract were to (1) prepare replication samples of electroless nickel coated aluminum, and determine process requirements for plating XDA test optic; (2) prepare and assemble plating equipment required to process a demonstration optic; (3) characterize mandrels, replicas and test samples for residual stress, surface contamination and surface roughness and figure using equipment at MSFC and; (4) provide technical expertise in establishing the processes, procedures, supplies and equipment needed to process the XDA test optics.

Engelhaupt, Darell↗

Stand Alone Electrical Equipment PRL 227a (Formerly PRL 227 LOC3) Confirmatory Sampling Report Addendum

HydroGeoLogic, Inc. (HGL) prepared this Confirmatory Sampling Report Addendum (CSRA) for the National Aeronautics and Space Administration (NASA), Kennedy Space Center (KSC), Florida. PRL 227a Location of Concern (LOC) 3 is located on 10th Street, west of the former Vertical Processing Facility (M7-1469), SWMU 077. The Load Break Switches (LBS) were installed in 1986 and are suspected to have formerly contained dielectric fluid that contained polychlorinated biphenyls (PCBs). The LBS were replaced in 1993 with new LBSs that do not contain PCBs. The LBS are located on a concrete pad surrounded by grass that is mowed and maintained. A total of 330 soil samples were collected between June 2020 and December 2022 from 88 locations at depths ranging from 0-0.5 to 19-20 ft bls. In general, soil samples collected from depths less than 5 ft were collected via hand auger and samples collected beyond 5 ft bls were collected using a direct-push technology drill rig. Soil samples collected from greater than 5 ft bls to 20 ft bls were collected to confirm PCBs were not present at depth in the aquifer matrix. Delineation samples were collected using an approximately 20 ft horizontal spacing. PCB impacted soil has been completely delineated to the State of Florida residential soil cleanup target level (SCTL) at PRL 227a horizontally and vertically. PCB concentrations have been identified above the residential and industrial SCTL as well as concentrations greater than or equal to 50 ppm requiring coordination with EPA and disposal at a facility authorized under TSCA. Based upon the CSRA sampling, an interim measure is recommended to remove PCB impacted soil above the residential SCTL. The total volume of PCB impacted soil to be removed is 591.6 cubic yards. This includes approximately 9.3 cubic yards of soil with PCB concentrations greater than or equal to 50 ppm. An interim measure work plan is included as an attachment to this report.

electrical equipment↗

Measuring Interdiffusion in Binary Liquids

Liquid-phase binary interdiffusion sample is prepared by enclosing wires of two metals in a capillary tube with ends touching. While sample is at elevated temperature, tube is kept oriented with lighter metal at top to prevent convection. New method is potential research tool in such areas as zone refining of metals, recycling of spent fuel rods, and improving removal of slag and inclusions from steel castings.

Gelles, S. H.↗

Effect of doping in the Bi-Sr-Ca-Cu-O superconductor

The results of the effect of doping on the superconducting transition in the Bi-Sr-Ca-Cu-O system are reported. Samples were prepared under identical conditions with varying types (Pb, Sb, Sn, Nb) and amounts of dopants. All samples consisted of multiple phases, and showed stable and reproducible superconducting transitions. Stabilization of the well known 110 K phase depends on both the type and amount of dopant. No trace of superconducting phase of 150 K and above was observed.

Akbar, S. A.↗