Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample delivery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Functional proteoliposome-like structure derived from simultaneous evisceration and enucleation of T-lymphoblastoid A3R5.7 cells: A top-down story

Highlights: • A3R5.7 and TF228.1.16 are capable of CD4-mediated membrane fusion. • Cytoplasmic and nuclear material can be removed simultaneously from A3R5.7 cells. • Resultant cell membrane remains intact, and retains presentation of CD4 and CXCR4. • Products are still capable of CD4-mediated membrane fusion with a target cell. • Useful for host-pathogen studies, and developing targeted delivery vehicles. Structurally-reduced cells and cell-derived structures are powerful tools for membrane studies. Using this approach, we probed whether a cell, without its nucleus and cytoplasm, is still capable of undergoing CD4-mediated membrane fusion. For this, we needed a cell-derived structure, akin to a giant liposome functionalised with CD4 and chemokine receptors. We present a method for the simultaneous removal of cytoplasmic and nuclear material from cells presenting CD4, CCR5, and CXCR4, using Colcemid treatment followed by hypotonic cytolysis, and then enriched using preparative flow cytometry. We show that the resultant cell membrane remains intact, retains presentation of CD4, CCR5, and CXCR4, and is still capable of CD4-mediated membrane fusion with a target cell. Finally, we detail how this protocol was developed, as well as how such samples should be handled for storage and assays. We envision the use of such systems for host-pathogen interaction studies, and the development of targeted delivery vehicles.

60 APPLIED LIFE SCIENCES↗

Using an external surrogate for predictor model training in real-time motion management of lung tumors

Purpose: Precise prediction of respiratory motion is a prerequisite for real-time motion compensation techniques such as beam, dynamic couch, or dynamic multileaf collimator tracking. Collection of tumor motion data to train the prediction model is required for most algorithms. To avoid exposure of patients to additional dose from imaging during this procedure, the feasibility of training a linear respiratory motion prediction model with an external surrogate signal is investigated and its performance benchmarked against training the model with tumor positions directly. Methods: The authors implement a lung tumor motion prediction algorithm based on linear ridge regression that is suitable to overcome system latencies up to about 300 ms. Its performance is investigated on a data set of 91 patient breathing trajectories recorded from fiducial marker tracking during radiotherapy delivery to the lung of ten patients. The expected 3D geometric error is quantified as a function of predictor lookahead time, signal sampling frequency and history vector length. Additionally, adaptive model retraining is evaluated, i.e., repeatedly updating the prediction model after initial training. Training length for this is gradually increased with incoming (internal) data availability. To assess practical feasibility model calculation times as well as various minimum data lengths for retraining are evaluated. Relative performance of model training with external surrogate motion data versus tumor motion data is evaluated. However, an internal–external motion correlation model is not utilized, i.e., prediction is solely driven by internal motion in both cases. Results: Similar prediction performance was achieved for training the model with external surrogate data versus internal (tumor motion) data. Adaptive model retraining can substantially boost performance in the case of external surrogate training while it has little impact for training with internal motion data. A minimum adaptive retraining data length of 8 s and history vector length of 3 s achieve maximal performance. Sampling frequency appears to have little impact on performance confirming previously published work. By using the linear predictor, a relative geometric 3D error reduction of about 50% was achieved (using adaptive retraining, a history vector length of 3 s and with results averaged over all investigated lookahead times and signal sampling frequencies). The absolute mean error could be reduced from (2.0 ± 1.6) mm when using no prediction at all to (0.9 ± 0.8) mm and (1.0 ± 0.9) mm when using the predictor trained with internal tumor motion training data and external surrogate motion training data, respectively (for a typical lookahead time of 250 ms and sampling frequency of 15 Hz). Conclusions: A linear prediction model can reduce latency induced tracking errors by an average of about 50% in real-time image guided radiotherapy systems with system latencies of up to 300 ms. Training a linear model for lung tumor motion prediction with an external surrogate signal alone is feasible and results in similar performance as training with (internal) tumor motion. Particularly for scenarios where motion data are extracted from fluoroscopic imaging with ionizing radiation, this may alleviate the need for additional imaging dose during the collection of model training data.

60 APPLIED LIFE SCIENCES↗

Perform Tests and Document Results and Analysis of Oxide Layer Effects and Comparisons

During the initial feasibility test using actual used nuclear fuel (UNF) cladding in FY 2012, an incubation period of 30–45 minutes was observed in the initial dry chlorination. The cladding hull used in the test had been previously oxidized in a dry air oxidation pretreatment prior to removal of the fuel. The cause of this incubation period was attributed to the resistance to chlorination of an oxide layer imparted by the dry oxidation pretreatment on the cladding. Subsequently in 2013, researchers at the Korea Atomic Energy Institute (KAERI) reported on their chlorination study [R1] on ~9-gram samples of unirradiated ZirloTM cladding tubes that had been previously oxidized in air at 500oC for various time periods to impart oxide layers of varying thickness. In early 2014, discussions with Indefinite Delivery, Indefinite Quantity (IDIQ) contracted technical consultants from Westinghouse described their previous development (and patents) [R2] on methods of chemical washing to remove some or all of the hydrous oxide layer imparted on UNF cladding during irradiation in light water reactors (LWRs) . Thus, the Oak Ridge National Laboratory (ORNL) study, described herein, was planned to extend the KAERI study on the effects of anhydrous oxide layers, but on larger ~100-gram samples of unirradiated zirconium alloy cladding tubes, and to investigate the effects of various methods of chemical pretreatment prior to chlorination with 100% chlorine on the average reaction rates and Cl2 usage efficiencies.

Korea Atomic Energy Institute (KAERI)↗

SU-F-T-305: Clinical Effects of Dosimetric Leaf Gap (DLG) Values Between Matched Varian Truebeam (TB) Linacs

Purpose: The dosimetric leaf gap (DLG) is an important parameter to be measured for dynamic beam delivery of modern linacs, like the Varian Truebeam (TB). The clinical effects of DLG-values on IMRT and/or VMAT commissioning of two “matched” TB linacs will be presented.Methods and Materials: The DLG values on two TB linacs were measured for all energy modalities (filtered and FFF-modes) as part of the dynamic delivery mode commissioning (IMRT and/or VMAT. After the standard beam data was modeled in eclipse treatment planning system (TPS) and validated, IMRT validation was performed based on TG1191 benchmark, IROC Head-Neck (H&N) phantom and sample of clinical cases, all measured on both linacs. Although there was a single-set of data entered in the TPS, a noticeable difference was observed for the DLG-values between the linacs. The TG119, IROC phantom and selected patient plans were furnished with DLG-values of TB1 for both linacs and the delivery was performed on both TB linacs for comparison. Results: The DLG values of TB1 was first used for both linacs to perform the testing comparisons. The QA comparison of TG119 plans revealed a great dependence of the results to the DLG-values used for the linac for all energy modalities studied, especially when moving from 3%/3mm to 2%/2mm γ-analysis. Conclusion: The DLG-values have a definite influence on the dynamic dose, delivery that increases with the plan complexity. We recommend that the measured DLG-values are assigned to each of the “matched” linacs, even if a single set of beam data describes multiple linacs. The user should perform a detail test of the dynamic delivery of each linac based on end-to-end benchmark suites like TG119 and IROC phantoms.1Ezzel G., et al., “IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119.” Med. Phys. 36:5359–5373 (2009). partly supported by CAMC Cancer Center and Alliance Oncology.

60 APPLIED LIFE SCIENCES↗

Impact of NASA’s Entry Systems Modeling Project on Planetary Mission Design

Planetary missions continue to grow larger and more complex. Furthermore, the current focus on human exploration of the Moon and Mars, as well as Mars Sample Return(MSR), place increas-ingly stringent requirements on the reliability of the entry, descent, and landing (EDL) system that ensures the safe delivery of payload or crew to their destination. Planetary EDL is an area in which mission designers are critically reliant on modeling and simulation to demonstrate the reliability of the system, as there are no ground facilities that are able to fully test these systems in a flight-relevant environment. NASA’s state-of-the-art modeling and simulation capability must continually evolve to meet the needs of the next generation of planetary EDL. To accomplish this aim, NASA’s Entry Systems Modeling (ESM) Project was formed in 2013and is funded bythe Space Technology Mission Directorate(STMD) and Science Mission Directorate (SMD). ESM is the Agency’s only cross-cutting effort for advancing entry systems modeling and simulation capabilities across a range of technical disciplines and Solar System destinations. ESM is a portfolio project covering a variety of mid-TRL research efforts within four core EDL-related areas of investment: (1) Thermal protection material modeling, (2) Shock layer kinetics and radiation, (3) Aerosciences, and (4) Guidance, navigation, and con-trol. The material modeling group creates detailed material response modelsof thermal protection systems (TPS)from the micro to macro scale, and at the fun-damental and engineering levels. Shock layer kinetics and radiation focuses on radiative heating of space-craft, quantum chemistry and benchmark experiments for validation.Aerosciences is a broad research area that impacts many aspects of entry systems, including parachutes, aerodynamics, and turbulent heating augmentation due to TPS roughness.The guidance, navigation,and control effort under ESM is expanding the capabilities of NASA’s main flight mechanics tool, POST2, for use on high-performance computing architectures and to generalize interoperability with external applications for more detailed end-to-end simula-tion.In addition, several focusedresearch topics have been approvedto augment ESM’s core portfolio. These include efforts for deep post-flight analysis of Mars 2020/MEDLI2 flight data; development ofTPS failure models; improvement of hypersonic wakeflow models; and a recently concluded effort to provide material response models for NuSil-coated PICA heat-shield material. This presentation will discuss each of these investment areas and demonstrate via real mission examples how advances to the state-of-the-art enabled by ESM are directly impacting the missions of today and tomorrow, including InSight, Mars 2020, Mars Sample Return, Orion, and Dragonfly.

Entry Systems Modeling↗

Measurement of laser power for photo-triggered drug delivery in vivo

Thus far, despite many investigations have been carried out for photo-triggered drug delivery systems, most of them suffer from an intrinsic drawback of without real-time monitoring mechanism. Incident intensity of light is a feasible parameter to monitor the drug release profiles. However, it is difficult to measure the incident laser power irradiated onto the photo-triggered carriers in drug delivery systems during in vivo therapy. We design an online measurement method based on the fluorescence intensity ratio (FIR) technique through upconversion nanoparticles. FIR value varies with temperature of sample due to the thermal effect induced by the incident laser, which validates the laser power measurement. Effects of rare earth doping concentration, as well as experimental conditions including laser spots and wavelengths on the measurement behavior were also investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Type 'A' V/STOL - One aircraft for all support missions

An investigation is conducted regarding the feasibility of developing a single support aircraft type for the Navy, taking into account the current naval inventory of utility aircraft types. Support mission characteristics are examined, giving attention to antisubmarine warfare, airborne early warning, marine assault, carrier on board delivery/vertical on board delivery, the aerial tanker mission, long-range rescue, surface attack, and aspects of combat, search, and rescue. With the aid of a sample design for a V/STOL aircraft with a medium disc loading lift system it is demonstrated that it is now possible to design an aircraft which, with minor modifications, can meet the wide variety of support missions.

Adelt, W. H.↗

The Marshall Space Flight Center Drop Tube Facility

The structural and instrumentation hardware and the improved experimental capabilities of a 105-m Drop Tube Facility are described. The structure is designed to provide a high-vacuum facility in a vertical orientation. The low-gravity environment obtained during free-fall and the containerless materials processing capabilities are discussed. Two furnaces, an electron-beam and an electromagnetic levitator, are used to melt metallic samples in a process environment ranging from 10 to the -6th torr to 1 atm. Specifics of the vacuum control and gas delivery systems are provided. The experimental instrumentation and data acquisition systems used to perform predrop and in-flight measurements of the melting and solidification process are discussed. Typical experimental results are presented as an indicator of the performance of the Drop Tube Facility.

Rathz, Thomas J.↗

WE-A-19A-01: SRT I: Comparison of SRT Techniques

Within the past several years, the field of radiosurgery has seen numerous technological enhancements, including new dedicated devices for stereotactic delivery, the use of re-locatable frames to facilitate fractionated delivery and the image guided frameless approaches. The goal of this symposium is to compare and contrast competing technologies for cranial SRS/SRT. The symposium will open with a review of the general concept of cranial SRS/SRT procedures as well as describe the key differences from conventional radiotherapy. The speakers will then review each of the delivery technique (Gamma Knife, CyberKnife and Conventional linear accelerator) in turn. The focus of each speaker will be to describe the general workflow of each SRS modality, indications and counterindications for treatment. To compare and contrast different technologies, 2–3 cases examples demonstrating interesting treatment situations and expected outcomes, a sample treatment plan (either live or pre-recorded with live commentary) demonstrating the treatment planning technique, and machine and patient-specific QA required for treatment (if applicable). Additionally, workflows and data describing the use of immobilization devices or tracking/monitoring during SRS/SRT delivery will also be discussed. The session will close with a roundtable discussion of methods to evaluate plan quality, and achievable technical and clinical goals for intracranial SRS. Learning Objectives: Understand the key differences between cranial SRS/SRT and conventional treatments. Review Gamma Knife, CyberKnife and Conventional Linac-based radiosurgery delivery techniques and quality assurance Compare and contrast treatment plans, treatment planning strategy and and quality assurance procedures for each technology. Be able to establish cranial SRS/SRT procedure with optimized quality assurance program for each technology.

60 APPLIED LIFE SCIENCES↗

Nanoflow electrospinning serial femtosecond crystallography

A low flow rate liquid microjet method for delivery of hydrated protein crystals to X-ray lasers is presented. Linac Coherent Light Source data demonstrates serial femtosecond protein crystallography with micrograms, a reduction of sample consumption by orders of magnitude. An electrospun liquid microjet has been developed that delivers protein microcrystal suspensions at flow rates of 0.14–3.1 µl min{sup −1} to perform serial femtosecond crystallography (SFX) studies with X-ray lasers. Thermolysin microcrystals flowed at 0.17 µl min{sup −1} and diffracted to beyond 4 Å resolution, producing 14 000 indexable diffraction patterns, or four per second, from 140 µg of protein. Nanoflow electrospinning extends SFX to biological samples that necessitate minimal sample consumption.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Unmanned Vehicle Material Flammability Test

Microgravity combustion phenomena have been an active area of research for the past 3 decades however, there have been very few experiments directly studying spacecraft fire safety under low-gravity conditions. Furthermore, none of these experiments have studied sample and environment sizes typical of those expected in a spacecraft fire. All previous experiments have been limited to samples of the order of 10 cm in length and width or smaller. Terrestrial fire safety standards for all other habitable volumes on earth, e.g. mines, buildings, airplanes, ships, etc., are based upon testing conducted with full-scale fires. Given the large differences between fire behavior in normal and reduced gravity, this lack of an experimental data base at relevant length scales forces spacecraft designers to base their designs using 1-g understanding. To address this question a large scale spacecraft fire experiment has been proposed by an international team of investigators. This poster presents the objectives, status and concept of this collaborative international project to examine spacecraft material flammability at realistic scales. The concept behind this project is to utilize an unmanned spacecraft such as Orbital Cygnus vehicle after it has completed its delivery of cargo to the ISS and it has begun its return journey to earth. This experiment will consist of a flame spread test involving a meter scale sample ignited in the pressurized volume of the spacecraft and allowed to burn to completion while measurements are made. A computer modeling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the examination of fire behavior on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation. This will be the first opportunity to examine microgravity flame behavior at scales approximating a spacecraft fire.

Combustion↗

A novel experimental approach to investigate radiolysis processes in liquid samples using collimated radiation sources

Here is detailed a novel and low-cost experimental method for high-throughput automated fluid sample irradiation. The sample is delivered via syringe pump to a nozzle, where it is expressed in the form of a hanging droplet into the path of a beam of ionising radiation. The dose delivery is controlled by an upstream lead shutter, which allows the beam to reach the droplet for a user defined period of time. The droplet is then further expressed after irradiation until it falls into one well of a standard microplate. The entire system is automated and can be operated remotely using software designed in-house, allowing for use in environments deemed unsafe for the user (synchrotron beamlines, for example). Depending on the number of wells in the microplate, several droplets can be irradiated before any human interaction is necessary, and the user may choose up to 10 samples per microplate using an array of identical syringe pumps, the design of which is described here. The nozzles consistently produce droplets of 25.1 ± 0.5 μl.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lunar Near-Surface Volatile Sample Return

The origin, distribution, depth and volume of lunar volatiles remain open questions. One of the possible sources of Moon's volatiles is their volcanic outgassing during the peak of lunar volcanic activity ~3.5 Ga. This same outgassing would also produce a tenuous transient atmosphere which would promote the delivery of volatiles from the volcanic sources to the polar cold traps. Though such an atmosphere could have played an important role in the evolution of the Moon, little is known about it due to high uncertainty level in the mechanisms involved. The only reliable proxy for the ancient lunar atmosphere are the primordial volatiles deposited by it, which are expected to be preserved in the polar cold traps, and could be studied through sample return. In this white paper we therefore advocate that a volatile sample return from the Moon's polar cold traps should be a fundamental part of the Artemis program.

Instrumentation and Methods for Astrophysics↗

A Novel Device for Intravaginal Electronic Brachytherapy

Purpose: Postoperative intravaginal brachytherapy for endometrial carcinoma is usually performed with {sup 192}Ir high-dose rate (HDR) afterloading. A potential alternative is treatment with a broadband 50kV X-ray point source, the advantage being its low energy and the consequential steep dose gradient. The aim of this study was to create and evaluate a homogeneous cylindrical energy deposition around a newly designed vaginal applicator. Methods and Materials: To create constant isodose layers along the cylindrical plastic vaginal applicator, the source (INTRABEAM system) was moved in steps of 17-19.5 mm outward from the tip of the applicator. Irradiation for a predetermined time was performed at each position. The axial shift was established by a stepping mechanism that was mounted on a table support. The total dose/dose distribution was determined using film dosimetry (Gafchromic EBT) in a 'solid water' phantom. The films were evaluated with Mathematica 5.2 and OmniPro-I'mRT 1.6. The results (dose D0/D5/D10 in 0/5/10 mm tissue depth) were compared with an {sup 192}Ir HDR afterloading plan for multiple sampling points around the applicator. Results: Three different dose distributions with lengths of 3.9-7.3 cm were created. The irradiation time based on the delivery of 5/7 Gy to a 5 mm tissue depth was 19/26 min to 27/38 min. D0/D5/D10 was 150%/100%/67% for electronic brachytherapy and 140%/100%/74% for the afterloading technique. The deviation for repeated measurements in the phantom was <7%. Conclusions: It is possible to create a homogeneous cylindrical dose distribution, similar to {sup 192}Ir HDR afterloading, through the superimposition of multiple spherical dose distributions by stepping a kilovolt point source.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Immortal Time Bias: A Frequently Unrecognized Threat to Validity in the Evaluation of Postoperative Radiotherapy

Purpose: To evaluate the influence of immortal time bias on observational cohort studies of postoperative radiotherapy (PORT) and the effectiveness of sequential landmark analysis to account for this bias. Methods and Materials: First, we reviewed previous studies of the Surveillance, Epidemiology, and End Results (SEER) database to determine how frequently this bias was considered. Second, we used SEER to select three tumor types (glioblastoma multiforme, Stage IA-IVM0 gastric adenocarcinoma, and Stage II-III rectal carcinoma) for which prospective trials demonstrated an improvement in survival associated with PORT. For each tumor type, we calculated conditional survivals and adjusted hazard ratios of PORT vs. postoperative observation cohorts while restricting the sample at sequential monthly landmarks. Results: Sixty-two percent of previous SEER publications evaluating PORT failed to use a landmark analysis. As expected, delivery of PORT for all three tumor types was associated with improved survival, with the largest associated benefit favoring PORT when all patients were included regardless of survival. Preselecting a cohort with a longer minimum survival sequentially diminished the apparent benefit of PORT. Conclusions: Although the majority of previous SEER articles do not correct for it, immortal time bias leads to altered estimates of PORT effectiveness, which are very sensitive to landmark selection. We suggest the routine use of sequential landmark analysis to account for this bias.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Simulation Monte Carlo Studies of the Gas Sampling for the VATMOS-SR Mission Concept

VATMOS-SR (Venus ATMOSpheric - Sample Return) is a small spacecraft mission concept which would return a gas sample from the upper atmosphere of Venus to Earth for scientific analysis. This could be the first sample return mission for an extra-terrestrial atmosphere, and potentially the first sample return from an Earth-sized planet. The VATMOS-SR mission concept consists of a SmallSat atmospheric sampling probe (45 deg. sphere/cone geometry, <1 m diameter) that is designed to skim through the Venus upper atmosphere and acquire gas samples below the homopause altitude (around ~110 km altitude), where the different atmospheric gases are mixed. The velocity of the spacecraft where sampling would occur is expected to be between ~10.5 km/s and ~13.1 km/s, depending on the trajectory chosen. This presentation will discuss hypervelocity sampling in the upper atmosphere of Venus, with respect to the VATMOS-SR mission concept. VATMOS-SR would enable critical atmospheric measurements to form a full picture of how, why, and when Venus evolved to be so different from Earth and Mars. The abundances and isotopic compositions of volatile elements (such as N, C, S, O and the noble gases) in planetary atmospheres record volatile delivery during accretion, outgassing from planetary interiors, and atmospheric loss to space. Precise and accurate determinations of atmospheric volatile signatures are the key to understanding the origins and geodynamical evolution of Venus compared to the other terrestrial planets. Hypersonic sampling poses unique technical and scientific challenges. To ensure it is possible to relate the composition of the sampled gases to the free stream atmospheric composition, large-scale numerical simulations are employed to model the flow through the VATMOS-SR sampling system. In particular, an emphasis is placed on quantifying noble gas isotopic fractionation that occurs during the sample acquisition and transfer process in order to determine how measured isotopic ratios of noble gases in the sample compare to actual isotopic ratios in the Venusian atmosphere. The Direct Simulation Monte Carlo (DSMC) code SPARTA, an open source software package developed by Sandia National Laboratories, is used in this work. SPARTA, based on Bird’s DSMC method, is a molecular-level gas-kinetic technique. As SPARTA is able to model hypervelocity reacting flows in strong chemical and thermal non-equilibrium, this software package is well suited to determine relevant flow properties for the VATMOS-SR mission concept, and to numerically quantify the expected level of elemental and/or isotopic fractionation in the sample acquired by VATMOS-SR. This presentation will show results from 3D simulations correlating the noble gas isotopic fractionation in the gas acquired at hypervelocity speeds to its ambient atmosphere value. In particular, emphasis will be placed at Xenon isotopes of masses 128 and 130, as precise measurements of that ratio would yield a comparison to Earth’s atmosphere. Additionally, sensitivity studies that quantify the uncertainties due to the freestream parameters as well as the modeling parameters will be performed.

direct simulation Monte Carlo↗