Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “roof”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

In-mine testing of a natural background sensor, part B

The capability of a natural background sensor for measuring the thickness of top coal on a longwall face was examined. The limitations on the time during which tests could be performed, and the roof conditions, did not produce readings of top coal measurements during the shearer operation. It was demonstrated that the system is capable to survive operating conditions in the mine environment, while the static tests confirmed that the natural background sensor approach is a valid method of measuring top coal thickness in mines where the roof rock provides a constant radiation level. It is concluded that the practical results will improve sequent development of an integrated vertical control system which is information from the natural background system.

Martzloff, F. D.↗

Side Shield for Wall Support

Method employs curved shield on each side of mining machine. In stowed position, shield folded against roof-support columns on one side. In deployed position, shield raised and braced against coal-seam wall by hydraulic cylinder. Shield supports wall until roof and wall properly secured by bolting and cement coating.

Lewis, E. V.↗

Residential Photovoltaic/Thermal Energy System

Proposed system supplies house with both heat and electricity. Pair of reports describes concept for self-sufficient heating, cooling, and power-generating system for house. Panels on walls of house provide hot water, space heating, and heat to charge heat-storage system, and generate electricity for circulation pumps and fans. Roof panels generate electricity for household, operate heat pump for summer cooling, and provide supplementary winter heating via heat pump, using solar-cell cooling-fluid loop. Wall and roof panels used independently.

Selcuk, M. K.↗

The structure of the Martian cryolithosphere upper levels

Structural inhomogeneities of the Martian cryolithosphere upper levels were studied by the proposed crater method. On the basis of analysis of 127 photomaps of 1:2 million scale morphological and morphometrical parameters of all the fresh craters larger than 1 km in diameter with fluidized ejecta and without it were investigated. Using the parameters of the craters, the roof depths of ice-bearing rocks were estimated and the data on the ice relative constant in the excavated permafrost layer were obtained. These data were used for the construction of maps of the boundary depth between ice-free nearsurface layer and ice-bearing rocks. A series of maps of the relative ice content for individual permafrost horizons was constructed. It was deduced from the obtained maps that the zone of the dryest nearsurface rocks on Mars is in the latitude belt + or - 30 degrees where maximum floor depths of the ice-bearing rocks vary from 400 to more than 400 m. It was found that the thickness of ice-free rocks in the Southern Hemisphere is larger than in the Northern one. The tendency of similarity of latitudinal zonality observed both on the maps of the minimal and mean roof depths may be considered as an indicator of structural stability of upper horizons of the Martian cryolithosphere down to the depths of 300 to 400 m. The areas of minimal ice content in the nearsurface layers coincide with the zone of maximum thickness of ice-free rocks. The ice relative content in Martian rocks becomes systematically higher from 30 deg latitude to the polars. The same tendency is observed in depth. The data obtained may be useful for the selecting of landing sites for Mars samples return and other missions.

Kuzmin, R. O.↗

Fate of a perched crystal layer in a magma ocean

The pressure gradients and liquid compressibilities of deep magma oceans should sustain the internal flotation of native crystals owing to a density crossover between crystal and liquid. Olivine at upper mantle depths near 250 km is considered. The behavior of a perched crystal layer is part of the general question concerning the fate of any transient crystal carried away from a cooling surface, whether this be a planetary surface or the roof of an intrusive magma body. For magma bodies thicker than a few hundred meters at modest crustal depths, the major cooling surface is the roof even when most solidification occurs at the floor. Importation of cool surroundings must also be invoked for the generation of a perched crystal layer in a magma ocean, but in this case the perched layer is deeply embedded in the hot part of the magma body, and far away from any cooling surface. Other aspects of this study are presented.

Morse, S. A.↗

Causes of failure of airship shed

The causes of the collapse of airship shed, which was being taken down at Niediergorsdorf, are discussed. This shed, which was built of iron, was 184 m long, 28 m high, and 35 m wide. The demolition of the shed had been assigned to unskilled men who proceeded to remove certain key structural supports, leaving the structure in such a condition that relatively small eccentricities of the columns or spans or of lateral forces could easily have caused the columns or spans to break down. A small gust of wind would have perhaps sufficed to bring the building down. An analysis is also given of the suction effects on the roof of an air shed in Staaken. The damage to this shed, which occurred during a storm, was due to the fact that the shed had no opening in its top for equalizing the air pressure within and without. The location of the plates blown off the roof correspond to the point of greatest suction.

Sonntag, R↗

Separation characteristics of generic stores from lee side of an inclined flat plate at Mach 6

An experimental investigation was conducted to determine the aerodynamic characteristics of a store as it was separated from the lee side of a flat plate inclined at 15 deg to the free-stream flow at Mach 6. Two store models were tested: a cone cylinder and a roof delta. Force and moment data were obtained for both stores as they were moved in 0.5-in. increments away from the flat plate lee-side separated flow region into the free-stream flow while the store angle of attack was held constant at either 0 deg or 15 deg. The results indicate that both stores had adverse separation characteristics (i.e., negative normal force and pitching moment) at an angle of attack of 0 deg, and the cone cylinder had favorable separation characteristics (i.e., positive normal force and pitching moment) at an angle of attack of 15 deg. At an angle of attack of 15 deg, the separation characteristics of the roof delta are indeterminate at small separation distances and favorable at greater separation distances. These characteristics are the result of the local flow inclination relative to the stores as they traversed through the flat plate lee-side flow field. In addition to plotted data, force and moment data are tabulated and schlieren photographs of the stores and flat plate are presented.

Wilcox, Floyd J., Jr.↗

President Clinton's Arrival at CCAS and Visit to KSC for Launch of STS-95

Live footage shows President Bill Clinton and First Lady Hillary Rodham Clinton arriving in Airforce 1 on the Skid Strip, viewing the launch, and tracking the plume of Space Shuttle Discovery, on mission STS-95. The viewing takes place on the roof of the Launch Control Center (LCC). Also present on the roof to watch this event are Astronaut Robert Cabana and Eileen Collins (both in flight suit), and the NASA Administrator Daniel Goldin. The President is shown giving a speech to the Launch Team and shaking hands with employees in the LCC.

Source record↗

Hostel for the Hajjis

Skidmore, Owings and Merrill (SOM), architects and engineers for the Haj Terminal, and the Saudi Ministry of Defense and Aviation needed to design some type of covered space that would process as many as 5,000 persons an hour and shelter up to 100,000 at a time during the annual haji pilgrimage. In this area, the temperature may reach 130 degrees Fahrenheit. The answer came from a fabric used by NASA in 1967 when they were looking for a new fabric for astronaut space suits. Owens Corning had been experimenting with an ultrafine pure glass finer yarn called Beta. The yarn was woven into a fabric, coated with Teflon and tailored for astronaut wear. SOM decided upon an open-sided, tented-roof structure with white Fiberglas fabric, coated with Teflon on both sides that reflects 75 percent of the solar radiation reaching the roof, thus helping to curb the intense heat.

Source record↗

High Accuracy 3D Processing of Satellite Imagery

Automatic DSM/DTM generation reproduces not only general features, but also detailed features of the terrain relief. Height accuracy of around 1 pixel in cooperative terrain. RMSE values of 1.3-1.5 m (1.0-2.0 pixels) for IKONOS and RMSE values of 2.9-4.6 m (0.5-1.0 pixels) for SPOT5 HRS. For 3D city modeling, the manual and semi-automatic feature extraction capability of SAT-PP provides a good basis. The tools of SAT-PP allowed the stereo-measurements of points on the roofs in order to generate a 3D city model with CCM The results show that building models with main roof structures can be successfully extracted by HRSI. As expected, with Quickbird more details are visible.

Gruen, A.↗

Radiative Forcing and Temperature Response to Changes in Urban Albedos and Associated CO2 Offsets

The two main forcings that can counteract to some extent the positive forcings from greenhouse gases from pre-industrial times to present-day are the aerosol and related aerosol-cloud forcings, and the radiative response to changes in surface albedo. Here, we quantify the change in radiative forcing and surface temperature that may be obtained by increasing the albedos of roofs and pavements in urban areas in temperate and tropical regions of the globe. Using the catchment land surface model (the land model coupled to the GEOS-5 Atmospheric General Circulation Model), we quantify the response of the total outgoing (outgoing shortwave+longwave) radiation to urban albedo changes. Globally, the total outgoing radiation increased by 0.5 W/square m and temperature decreased by -0.008 K for an average 0.003 increase in albedo. For the U.S. the total outgoing total radiation increased by 2.3 W/square meter, and temperature decreased by approximately 0.03 K for an average 0.01 increase in albedo. These values are for the boreal summer (Tune-July-August). Based on these forcings, the expected emitted CO2 offset for a plausible 0.25 and 0.15 increase in albedos of roofs and pavements, respectively, for all global urban areas, was found to be approximately 57 Gt CO2 . A more meaningful evaluation of the impacts of urban albedo increases on climate and the expected CO2 offsets would require simulations which better characterizes urban surfaces and represents the full annual cycle.

Menon, Surabi↗

A Sinuous Tumulus over an Active Lava Tube at Klauea Volcano: Evolution, Analogs, and Hazard Forecasts

Inflation of narrow tube-fed basaltic lava flows (tens of meters across), such as those confined by topography, can be focused predominantly along the roof of a lava tube. This can lead to the development of an unusually long tumulus, its shape matching the sinuosity of the underlying lava tube. Such a situation occurred during Klauea Volcanos (Hawaii, USA) ongoing East Rift Zone eruption on a lava tube active from July through November 2010. Short-lived breakouts from the tube buried the flanks of the sinuous, ridge-like tumulus, while the tumulus crest, its surface composed of lava formed very early in the flows emplacement history, remained poised above the surrounding younger flows. At least several of these breakouts resulted in irrecoverable uplift of the tube roof. Confined sections of the prehistoric Carrizozo and McCartys flows (New Mexico, USA) display similar sinuous, ridge-like features with comparable surface age relationships. We contend that these distinct features formed in a fashion equivalent to that of the sinuous tumulus that formed at Kīlauea in 2010. Moreover, these sinuous tumuli may be analogs for some sinuous ridges evident in orbital images of the Tharsis volcanic province on Mars. The short-lived breakouts from the sinuous tumulus at Kīlauea were caused by surges in discharge through the lava tube, in response to cycles of deflation and inflation (DI events) at Kīlauea's summit. The correlation between DI events and subsequent breakouts aided in lava flow forecasting. Breakouts from the sinuous tumulus advanced repeatedly toward the sparsely populated Kalapana Gardens subdivision, destroying two homes and threatening others. Hazard assessments, including flow occurrence and advance forecasts, were relayed regularly to the Hawaiʻi County Civil Defense to aid their lava flow hazard mitigation efforts while this lava tube was active.

volcanic hazards↗

Confinement of Screw Dislocations to Predetermined Lateral Positions in (0001) 4H-SiC Epilayers Using Homoepitaxial Web Growth

This paper reports initial demonstration of a cantilevered homoepitaxial growth process that places screw dislocations at predetermined lateral positions in on-axis 4H-SiC mesa epilayers. Thin cantilevers were grown extending toward the interior of hollow pre-growth mesa shapes etched into an on-axis 4H-SiC wafer, eventually completely coalescing to form roofed cavities. Each completely coalesced cavity exhibited either: 1) a screw dislocation growth spiral located exactly where final cantilever coalescence occurred, or 2) no growth spiral. The fact that growth spirals are not observed at any other position except the central coalescence point suggests that substrate screw dislocations, initially surrounded by the hollow portion of the pre-growth mesa shape, are relocated to the final coalescence point of the webbed epilayer roof. Molten potassium hydroxide etch studies revealed that properly grown webbed cantilevers exhibited no etch pits, confirming the superior crystal quality of the cantilevers.

Neudeck, Philip G.↗

Satellite Beach Energy - Restructuring the Energy Balance in Satellite Beach, Florida, by Quantifying Solar Energy Production Potential using NASA POWER Data Products and LiDAR

The City of Satellite Beach, Florida, has committed to supplying 100% of its energy use from renewable energy, primarily solar, by the year 2050. The team created a methodology for estimating rooftop solar power potential using a high-resolution Light Detection and Ranging (LiDAR) dataset and the NASA Prediction of Worldwide Energy Resources (POWER) dataset to assist Satellite Beach in reaching their solar renewable energy goals. The POWER dataset provides information on direct and diffuse solar irradiation on horizontal surfaces, surface albedo, and effects of local meteorology, such as clouds. The team integrated the solar irradiance data with the LiDAR data to model slope, aspect, and shadowing in the 7 km2 study area to find suitable roof segments for solar panel installation and estimate the solar potential of each segment. This process was supplemented by an analysis of land surface temperature and urban greenness measured through the Normalized Difference Vegetation Index (NDVI) from Landsat 8 Operational Land Imager and Thermal Infrared Sensor (OLI/TIRS) observations. These metrics serve to target areas for cooling initiatives aimed at reducing Satellite Beach’s overall energy consumption. The team found the total rooftop solar potential throughout the city to be 221,919,330KWh per year with an average annual rooftop photovoltaic, or PV, potential of 55,647KWh per building. As such, the average building could generate over five times the annual energy needs for an average household if PV panels were installed on all viable areas of its roof.

Spencer Nelson↗

DOE Zero Energy Ready Home Case Study: Durable Energy Builders - Houston, Texas

This case study describes a DOE Zero Energy Ready Home in Houston, Texas, that scored HERS 39 without PV and HERS 29 with PV. This 5,947 ft2 custom home has 11.5-inch ICF walls. The attic is insulated along the roof line with 5 to 7 inches of open-cell spray foam. Most of the home's drinking water is supplied by a 11,500-gallon rainwater cistern. Hurricane strapping connects the roof to the walls. The triple-pane windows are impact resistant. The foundation is a raised slab.

builder↗

Geostellar: Remote Solar Energy Assessments Personalized

Geostellar has produced an online tool that generates a unique solar profile for homeowners to learn about the financial benefits to installing rooftop solar panels on their home. The website incorporates the physical building characteristics of the home, including shading, slope, and orientation of the roof, and applies electricity costs and incentives to determine the best solar energy estimated energy production values against actual installed rooftop photovoltaic systems. The validation conducted by NREL concluded that over three-quarters of Geostellar's potential size estimates are at least as large as the actual installed systems, indicating a correct assessment of roof availability. In addition, 87% of Geostellar's 25-year production estimates are within 90% of the actual PV Watts results.

14 SOLAR ENERGY↗

Development of High Performance Composite Foam Insulation with Vacuum Insulation Cores

Development of a high performance thermal insulation (thermal resistance or R-value per inch of R-12 hr-ft2- F/Btu-in or greater), with twice the thermal resistance of state-of-the-art commercial insulation materials ( R6/inch for foam insulation), promises a transformational impact in the area of building insulation. In 2010, in the US, the building envelope-related primary energy consumption was 15.6 quads, of which 5.75 quads were due to opaque wall and roof sections; the total US consumption (building, industrial and transportation) was 98 quads. In other words, the wall and roof contribution was almost 6% of the entire US primary energy consumption. Building energy modeling analyses have shown that adding insulation to increase the R-value of the external walls of residential buildings by R10-20 (hr-ft2- F/Btu) can yield savings of 38-50% in wall-generated heating and cooling loads. Adding R20 will require substantial thicknesses of current commercial insulation materials, often requiring significant (and sometimes cost-prohibitive) alterations to existing buildings. This article describes the development of a next-generation composite insulation with a target thermal resistance of R25 for a 2 inch thick board (R12/inch or higher). The composite insulation will contain vacuum insulation cores, which are nominally R35-40/inch, encapsulated in polyisocyanurate foam. A recently-developed variant of vacuum insulation, called modified atmosphere insulation (MAI), was used in this research. Some background information on the thermal performance and distinguishing features of MAI has been provided. Technical details of the composite insulation development and manufacturing as well as laboratory evaluation of prototype insulation boards are presented.

Biswas, Kaushik↗