Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rf source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Femtosecond MeV Electron Energy-Loss Spectroscopy

Pump-probe electron energy-loss spectroscopy (EELS) with femtosecond temporal resolution will be a transformative research tool for studying nonequilibrium chemistry and electronic dynamics of matter. Here in this article, we propose a concept of femtosecond EELS utilizing mega-electron-volt electron beams from a radio-frequency (rf) photocathode source. The high acceleration gradient and high beam energy of the rf gun are critical to the generation of 10-fs electron beams, which enables an improvement of the temporal resolution by more than 1 order of magnitude beyond the state of the art. In our proposal, the “referencebeam technique” relaxes the energy stability requirement of the rf power source by roughly 2 orders of magnitude. The requirements for the electron-beam quality, photocathode, spectrometer, and detector are also discussed. Supported by particle-tracking simulations, we demonstrate the feasibility of achieving subelectron- volt energy resolution and approximately 10-fs temporal resolution with existing or near-future hardware performance.

43 PARTICLE ACCELERATORS↗

The Spallation Neutron Source Normal Conducting Linac RF System Design for the Proton Power Upgrade Project

The Proton Power Upgrade (PPU) project at the Spallation Neutron Source will double the available proton beam power from 1.4 to 2.8 MW by increasing the beam energy from 1.0 to 1.3 GeV and the beam current from 26 to 38 mA. The increase in beam current resulted in the need to redesign the existing normal conducting linac (NCL) RF Systems. High-power testing of the existing NCL RF Systems configured to accelerate PPU-level beam provided the data used to make the final design decisions. This paper describes the development and execution of those in-situ tests and the subsequent results.

Moss, John↗

Beam Homogeneity Dependence on the Magnetic Filter Field at the IPP Test Facility MANITU

The homogeneity of the extracted current density from the large RF driven negative hydrogen ion sources of the ITER neutral beam system is a critical issue for the transmission of the negative ion beam through the accelerator and the beamline components. As a first test, the beam homogeneity at the IPP long pulse test facility MANITU is measured by means of the divergence and the stripping profiles obtained with a spatially resolved Doppler-shift spectroscopy system. Since MANITU is typically operating below the optimum perveance, an increase in the divergence corresponds to a lower local extracted negative ion current density if the extraction voltage is constant. The beam H{sub {alpha}} Doppler-shift spectroscopy is a rather simple tool, as no absolute calibration - both for the wavelength and the emission - is necessary. Even no relative calibration of the different used lines of sight is necessary for divergence and stripping profiles as these quantities can be obtained by the line broadening of the Doppler-shifted peak and the ratio of the integral of the stripping peak to the integral of the Doppler-shifted peak, respectively. The paper describes the H{sub {alpha}} MANITU Doppler-shift spectroscopy system which is now operating routinely and the evaluation methods of the divergence and the stripping profiles. Beam homogeneity measurements are presented for different extraction areas and magnetic filter field configurations both for Hydrogen and Deuterium operation; the results are compared with homogeneity measurements of the source plasma. The stripping loss measurements are compared with model calculations.

43 PARTICLE ACCELERATORS↗

Sources of Emittance in RF Photocathode Injectors

Advances in electron beam technology have been central to creating the current generation of x-ray free electron lasers and ultra-fast electron microscopes. These once exotic devices have become essential tools for basic research and applied science. One important beam technology for both is the electron source which, for many of these instruments, is the photocathode RF gun. The invention of the photocathode gun and the concepts of emittance compensation and beam matching in the presence of space charge and RF forces have made these high-quality beams possible. Achieving even brighter beams requires a taking a finer resolution view of the electron dynamics near the cathode during photoemission and the initial acceleration of the beam. In addition, the high brightness beam is more sensitive to degradation by the optical aberrations of the gun’s RF and magnetic lenses. This paper discusses these topics including the beam properties due to fundamental photoemission physics, space charge effects close to the cathode, and optical distortions introduced by the RF and solenoid fields. Analytic relations for these phenomena are derived and compared with numerical simulations.

43 PARTICLE ACCELERATORS↗

Pre-conditioning procedure suitable for internal-RF-antenna of J-PARC RF-driven H{sup −} ion source

The Japan Proton Accelerator Research Complex (J-PARC) cesiated RF-driven H{sup −} ion source has been successfully operated for about 1 yr. By the world brightest level beam, the J-PARC design beam power of 1 MW was successfully demonstrated. Although no internal-RF-antenna failure, except for the once caused by an excess cesium due to a misoperation, occurred in the operation, many antennas failed in pre-conditionings for the first hundred days. The antenna failure rate was drastically decreased by using an antenna with coating thicker than a standard value and the pre-conditioning procedure repeating 15 min 25 kW RF-power operation and impurity-gas evacuation a few times, before the full power (50 kW) operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signal transmitter and methods for transmitting signals from animals

Injectable transmitters are provided that can include a body with the body housing a power source and an oscillator, the injectable transmitter also including an antenna extending from the body, the body and antenna being of sufficient size to be injected through a 9 gauge needle. Radio frequency transmitters are provided that can include a body extending from a nose to a tail with the body housing a power source and RF signal generator components. The power source of the transmitter can define at least a portion of the nose of the body. The transmitters can have an antenna extending from the tail. Methods for attaching a radio frequency (RF) transmitter to an animal are provided. The methods can include providing an RF transmitter and providing an injection device having a needle of gauge of 9 or smaller; providing the RF transmitter into the injection device; and providing the RF transmitter through the 9 gauge or smaller needle and into the animal.

Deng, Z. Daniel↗

Plasma And Beam Homogeneity Of The RF-Driven Negative Hydrogen Ion Source For ITER NBI

The neutral beam injection (NBI) system of ITER is based on a large RF driven negative hydrogen ion source. For good beam transmission ITER requires a beam homogeneity of better than 10%. The plasma uniformity and the correlation with the beam homogeneity are being investigated at the prototype ion sources at IPP. Detailed studies are carried out at the long pulse test facility MANITU with a source of roughly 1/8 of the ITER source size. The plasma homogeneity close to plasma grid is measured by optical emission spectroscopy and by fixed Langmuir probes working in the ion saturation region. The beam homogeneity is measured with a spatially resolved H{sub {alpha}} Doppler-shifted beam spectroscopy system. The plasma top-to-bottom symmetry improves with increasing RF power and increasing bias voltage which is applied to suppress the co-extracted electron current. The symmetry is better in deuterium than in hydrogen. The boundary layer near the plasma grid determines the plasma symmetry. At high ion currents with a low amount of co-extracted electrons the plasma is symmetrical and the beam homogeneity is typically 5-10%(RMS). The size scaling and the influence of the magnetic field strength of the filter field created by a plasma grid current is studied at the test facility RADI (roughly a 1/2 size ITER source) at ITER relevant RF power levels. In volume operation in deuterium (non-cesiated source), the plasma illumination of the grid is satisfying.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fine-tuning to minimize emittances of J-PARC RF-driven H{sup −} ion source

The Japan Proton Accelerator Research Complex (J-PARC) cesiated RF-driven H{sup −} ion source has been successfully operated for about one year. By the world’s brightest level beam, the J-PARC design beam power of 1 MW was successfully demonstrated. In order to minimize the transverse emittances, the rod-filter-field (RFF) was optimized by changing the triple-gap-lengths of each of pairing five piece rod-filter-magnets. The larger emittance degradation seems to be caused by impurity-gases than the RFF. The smaller beam-hole-diameter of the extraction electrode caused the more than expected improvements on not only the emittances but also the peak beam intensity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface Plasma Source Electrode Activation by Surface Impurities

In experiments with RF saddle antenna surface plasma sources (SPS), the efficiency of H- ion generation was increased by up to a factor of 5 by long time plasma electrode activation, without adding Cs from Cs supply, by heating the collar to high temperature using hot air flow and plasma discharge. Without cracking or heating the cesium ampoule, but likely with Cs recovery from impurities, the achieved energy efficiency was comparable to that of conventionally cesiated SNS RF sources with an external or internal Cs supply. In the experiments, perfect cesiation was produced (without additional Cs supply) by the collection and trapping of traces of remnant cesium compounds from SPS surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of a superconducting adiabatic radio frequency neutron resonant spin flipper

The neutron radio frequency (RF) spin flipper is one of the key components to implement neutron resonance spin echo (NRSE) for high resolution measurements of dynamics in materials. Various types of RF flippers have been built and implemented including adiabatic and non-adiabatic RF flippers. For a pulsed neutron source, adiabatic RF flipper is more favorable due to its wide operation bandwidth. However, the optimization criteria of an adiabatic RF flipper is still lacking. Also they are difficult to be operated in bootstrap mode, which can be use to minimize the phase aberration and increase the achievable resolution. In the report by Dadisman et al. (2019), an adiabatic RF flipper has been built for the first time with superconducting technologies, which allows bootstrap mode. Here in this article, the method of optimizing the device and the detailed design will be discussed for each component of the device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wireless power transfer to biomedical implants

Various examples are provided for wireless power transfer to implants. In one example, a system includes a radio frequency (RF) power source and a transmitter (TX) array comprising an excitation coil and resonant coils distributed about the excitation coil. The TX array can transfer power from the RF power source to a biomedical implant inserted below a skin surface of a subject when the TX array is positioned on the skin surface adjacent to the biomedical implant. A receiver (RX) coil of the biomedical implant can inductively couple with the TX array for the power. The resonant coils can allow power transfer when the RX coil is not aligned with the excitation coil.

Lin, Jenshan↗

Wireless power transfer to biomedical implants

Various examples are provided for wireless power transfer to implants. In one example, a system includes a radio frequency (RF) power source and a transmitter (TX) array comprising an excitation coil and resonant coils distributed about the excitation coil. The TX array can transfer power from the RF power source to a biomedical implant inserted below a skin surface of a subject when the TX array is positioned on the skin surface adjacent to the biomedical implant. A receiver (RX) coil of the biomedical implant can inductively couple with the TX array for the power transfer. The resonant coils can allow power transfer when the RX coil is not aligned with the excitation coil.

Lin, Jenshan↗

Versatile Low Level RF System For Linear Accelerators

The Low Level RF (LLRF) system is the source of all of the rf signals required for an rf linear accelerator. These signals are amplified to drive accelerator and buncher cavities. It can even provide the synchronizing signal for the rf power for a synchrotron. The use of Direct Digital Synthesis (DDS) techniques results in a versatile system that can provide multiple coherent signals at the same or different frequencies with adjustable amplitudes and phase relations. Pulsing the DDS allows rf switching with an essentially infinite on/off ratio. The LLRF system includes a versatile phase detector that allows phase-locking the rf frequency to a cavity at any phase angle over the full 360 deg. range. With the use of stepper motor driven slug tuners multiple cavity resonant frequencies can be phase locked to the rf source frequency. No external phase shifters are required and there is no feedback loop phase setup required. All that is needed is to turn the frequency feedback on. The use of Digital Signal Processing (DSP) allows amplitude and phase control over the entire rf pulse. This paper describes the basic principles of a LLRF system that has been used for both proton accelerators and electron accelerators, including multiple tank accelerators, sub-harmonic and fundamental bunchers, and synchrotrons.

43 PARTICLE ACCELERATORS↗

LCLS-II high power RF system overview and progress

A second X-ray free electron laser facility, LCLS-II, will be constructed at SLAC. LCLS-II is based on a 1.3 GHz, 4 GeV, continuous-wave (CW) superconducting linear accelerator, to be installed in the first kilometer of the SLAC tunnel. Multiple types of high power RF (HPRF) sources will be used to power different systems on LCLS-II. The main 1.3 GHz linac will be powered by 280 1.3 GHz, 3.8 kW solid state amplifier (SSA) sources. The normal conducting buncher in the injector will use four more SSAs identical to the linac SSAs but run at 2 kW. Two 185.7 MHz, 60 kW sources will power the photocathode dual-feed RF gun. A third harmonic linac section, included for linearizing the bunch energy spread before the first bunch compressor, will require sixteen 3.9 GHz sources at about 1 kW CW. A description and an update on all the HPRF sources of LCLS-II and their implementation is the subject of this paper.

43 PARTICLE ACCELERATORS↗

Particle-in-cell simulation of hydrogen discharge driven by combined radio frequency and pulse sources

A particle-in-cell plus Monte Carlo collision model is employed to investigate the low pressure hydrogen capacitive discharge driven by combined radio frequency (rf) and pulse sources. This work focuses on the evolutions of electron energy and density in the discharge to illustrate the role that a short pulse source plays. The simulation results show that an extra short pulse source can modulate the electron energy effectively: in the early and late pulse-on times, the electron energy is much higher than that in the single rf source discharge; during the pulse-off time, the electron energy can drop gradually to a low value. It is also found that a few peaks of attenuated electron energy appear periodically just after the pulse voltage drops to zero. The similar phenomena can also be found in the production rate of highly vibrationally excited hydrogen molecules. Physical mechanisms responsible for these phenomena are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radio frequency-driven proton source with a back-streaming electron dump

This article describes an rf ion source with a back-streaming electron dump. A quartz tube, brazed to a metal plug at one end, is fused in the center of a flat quartz plate. rf power (at 13.6 MHz) is coupled to generate hydrogen plasma using a planar external antenna bonded to the window. Bonding the water-cooled rf antenna to the quartz window significantly lowers its temperature. The water-cooled metal plug serves as the back-streaming electron dump. At 1800 W, the current density of extracted hydrogen ions reaches approximately 125 mA/cm{sup 2}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influences of impedance matching network on pulse-modulated radio frequency atmospheric pressure glow discharges

Pulse-modulated RF atmospheric pressure glow discharges (APDGs) were investigated in recent years to reduce the thermal accumulation and extend the operation region of the stable alpha glow mode. Different pulse-modulated voltage and current waveforms were acquired in previous experiments, but no attention was paid to the interpretation. We investigated this issue and associated phenomenon via positive and negative feedback effects derived from varying the series capacitor in the inversely L-shaped matching network used in our pulse-modulated RF APGD source. The evolutions of pulse-modulated RF waveforms were found to be associated with the feedback region and the pulsed plasma absorbed RF power. In the positive feedback region, pulse-modulated RF APGDs are relatively stable. In the negative feedback region, wide spikes as well as undershoots occur in RF voltage and current waveforms and the plasma absorbed RF power. In case of a high RF power discharge with a low modulation frequency, the pulse-modulated RF APGD is extinguished and re-ignited due to the enhanced undershoot during the initial pulse phase. The pulse-modulated RF APGD can transit from positive to negative feedback region in a range of series capacitance. Experimental results are discussed by the aid of equivalent circuit, negative and positive feedback effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗