Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “receiver functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Cyclic spectroscopy of the millisecond pulsar, B1937+21

Cyclic spectroscopy is a signal processing technique that was originally developed for engineering applications and has recently been introduced into the field of pulsar astronomy. It is a powerful technique with many attractive features, not least of which is the explicit rendering of information about the relative phases in any filtering imposed on the signal, thus making holography a more straightforward proposition. Here we present methods for determining optimum estimates of both the filter itself and the statistics of the unfiltered signal, starting from a measured cyclic spectrum. In the context of radio pulsars these quantities tell us the impulse response of the interstellar medium (ISM) and the intrinsic pulse profile. We demonstrate our techniques by application to 428 MHz Arecibo data on the millisecond pulsar B1937+21, obtaining the pulse profile free from the effects of interstellar scattering. As expected, the intrinsic profile exhibits main- and inter-pulse components that are narrower than they appear in the scattered profile; it also manifests some weak, but sharp, features that are revealed for the first time at low frequency. We determine the structure of the received electric field envelope as a function of delay and Doppler shift. Our delay Doppler image has a high dynamic range and displays some pronounced, low-level power concentrations at large delays. These concentrations imply strong clumpiness in the ionized ISM, on AU-size scales, which must adversely affect the timing of B1937+21.

79 ASTRONOMY AND ASTROPHYSICS↗

Heinz-resistant tomato cultivars exhibit a lignin-based resistance to field dodder ( Cuscuta campestris ) parasitism

Cuscuta species (dodders) are agriculturally destructive, parasitic angiosperms. These parasitic plants use haustoria as physiological bridges to extract nutrients and water from hosts. Cuscuta campestris has a broad host range and wide geographical distribution. While some wild tomato relatives are resistant, cultivated tomatoes are generally susceptible to C. campestris infestations. However, some specific Heinz tomato (Solanum lycopersicum) hybrid cultivars exhibit resistance to dodders in the field, but their defense mechanism was previously unknown. Here, we discovered that the stem cortex in these resistant lines responds with local lignification upon C. campestris attachment, preventing parasite entry into the host. Lignin Induction Factor 1 (LIF1, an AP2-like transcription factor), SlMYB55, and Cuscuta R-gene for Lignin-based Resistance 1, a CC-NBS-LRR (CuRLR1) are identified as factors that confer host resistance by regulating lignification. SlWRKY16 is upregulated upon C. campestris infestation and potentially negatively regulates LIF1 function. Intriguingly, CuRLR1 may play a role in signaling or function as an intracellular receptor for receiving Cuscuta signals or effectors, thereby regulating lignification-based resistance. In summary, these four regulators control the lignin-based resistance response in specific Heinz tomato cultivars, preventing C. campestris from parasitizing resistant tomatoes. This discovery provides a foundation for investigating multilayer resistance against Cuscuta species and has potential for application in other essential crops attacked by parasitic plants.

59 BASIC BIOLOGICAL SCIENCES↗

SU-G-TeP4-11: Implementation of a Non-Measurement-Based Patient-Specific IMRT QA Program

Purpose: To implement a comprehensive non-measurement-based verification program for patient-specific IMRT QA Methods: Based on published guidelines, a robust IMRT QA program should assess the following components: 1) accuracy of dose calculation, 2) accuracy of data transfer from the treatment planning system (TPS) to the record-and-verify (RV) system, 3) treatment plan deliverability, and 4) accuracy of plan delivery. Results: We have implemented an IMRT QA program that consist of four components: 1) an independent re-calculation of the dose distribution in the patient anatomy with a commercial secondary dose calculation program: Mobius3D (Mobius Medical Systems, Houston, TX), with dose accuracy evaluation using gamma analysis, PTV mean dose, PTV coverage to 95%, and organ-at-risk mean dose; 2) an automated in-house-developed plan comparison system that compares all relevant plan parameters such as MU, MLC position, beam iso-center position, collimator, gantry, couch, field size settings, and bolus placement, etc. between the plan and the RV system; 3) use of the RV system to check the plan deliverability and further confirm using “mode-up” function on treatment console for plans receiving warning; and 4) implementation of a comprehensive weekly MLC QA, in addition to routine accelerator monthly and daily QA. Among 1200 verifications, there were 9 cases of suspicious calculations, 5 cases of delivery failure, no data transfer errors, and no failure of weekly MLC QA. These 9 suspicious cases were due to the PTV extending to the skin or to heterogeneity correction effects, which would not have been caught using phantom measurement-based QA. The delivery failure was due to the rounding variation of MLC position between the planning system and RV system. Conclusion: A very efficient, yet comprehensive, non-measurement-based patient-specific QA program has been implemented and used clinically for about 18 months with excellent results.

60 APPLIED LIFE SCIENCES↗

Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107

At the time of this testing, the Low-Activity Waste Pretreatment System (LAWPS) was to provide for the initial production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility for immobilization. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 (hereafter called AP-107) be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange) then vitrified. A small-scale test platform to demonstrate the solids filtration, Cs removal, and LAW vitrification was constructed and installed at Pacific Northwest National Laboratory. Bench-scale ion exchange testing with approximately 9 L of AP-107 supernate was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Batch 2081000057). The ion exchange media was first tested with simulant and was previously described. This report describes the Cs ion exchange batch contact and column test results with the AP-107 tank waste. Batch contact testing helps to evaluate CST performance on tank waste supernate prior to processing it in the ion exchange columns. Batch contacts were performed with the waste at four Cs concentrations at a phase ratio of 200 (liquid volume to exchanger mass) with AP-107. The distribution coefficient (K d ) at the equilibrium condition of 8.57 µg Cs/mL (AP-107 feed condition) was determined to be 669 mL AP-107/g CST. With a CST bed density of 1.00 g/mL, this K d corresponded to a predicted 50% Cs breakthrough of 669 bed volumes (BVs). The Cs load capacity at the equilibrium feed condition was determined to be 7.5 mg Cs/g dry CST. The column testing was prototypic to the intended LAWPS operations in a lead-lag column format, although on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column at ~2.2 BV/h. Loading continued until the lag column reached the WTP waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and 137 Cs concentrations). For AP-107, the WAC is 0.114% of the influent 137 Cs concentration; this required a Cs decontamination factor of 876. The Cs effluent from the lag column reached the WAC after processing ~410 BVs. To keep the subsequent product effluent below the WAC, a replacement lag column was prepared, the lead column was removed from service (after processing a total of 471 BVs), the lag column was put into the lead column position, and the replacement lag column was installed. Feed processing continued and after another ~290 BVs the Cs effluent from the lag column again exceeded the WAC. In both cases, the lead columns only reached 25% Cs breakthrough before removal. Although 50% Cs breakthrough was not reached, this value was estimated and averaged based on extrapolation of the loading curves (640 BVs) and agreed within 4% of the predicted 50% Cs breakthrough from batch contact test results (669 BVs). Table ES.1 summarizes the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of laser heterodyne communications

Computer program, which predicts effects of optical aberrations on transmitters and receivers, includes effects of Gaussian pupil functions and utilizes algorithm that permits specification of number and location of output points for computed spread function results.

Cohen, S.↗

A versatile microprocessor-controlled hybrid receiver

A hybrid receiver has been designed for the Galileo Project. The receiver, located on the Galileo Orbiter, will autonomously acquire and track signals from the first atmospheric probe of Jupiter as well as demodulate, bit-synchronize, and buffer the telemetry data. The receiver has a conventional RF and LF front end but performs multiple functions digitally under firmware control. It will be a self-acquiring receiver that operates under a large frequency uncertainty; it can accommodate different modulation types, bit rates, and other parameter changes via reprogramming. A breadboard receiver and test set demonstrate a preliminary version of the sequential detection process and verify the hypothesis that a fading channel does not reduce the probability of detection.

Grant, T. L.↗

Definition study of land/sea civil user navigational location monitoring systems for NAVSTAR GPS: User requirements and systems concepts

A low-cost GPS civil-user mobile terminal whose purchase cost is substantially an order of magnitude less than estimates for the military counterpart is considered with focus on ground station requirements for position monitoring of civil users requiring this capability and the civil user navigation and location-monitoring requirements. Existing survey literature was examined to ascertain the potential users of a low-cost NAVSTAR receiver and to estimate their number, function, and accuracy requirements. System concepts are defined for low cost user equipments for in-situ navigation and the retransmission of low data rate positioning data via a geostationary satellite to a central computing facility.

Devito, D. M.↗

LANDSAT-D band 6 data evaluation

A filter, fabricated to match the spectral response of the LANDSAT band 6 sensors, was received and the combined system response function computed. The half power points for the aircraft system are 10.5 micrometer and 11.55 micrometer compared to the 10.4 and 11.6 micrometer values for the satellite. These discrepancies are considered acceptable; their effect on the apparent temperature observed at the satellite is being evaluated. The filter was installed in the infrared line scanner and the line scanner was installed in the aircraft and field checked. A daytime underflight of the satellite is scheduled for the next clear overpass and the feasibility of a nightime overpass is being discussed with NASA. The LOWTRAN 5 computer code was obtained from the Air Force Geophysical Laboratory and is being implemented for use on this effort.

Source record↗

A lidar instrument to measure H2O and aerosol profiles from the NASA ER-2 aircraft

Plans to develop the Lidar Atmospheric Sensing Experiment (LASE) instrument to conduct scientific experiments aboard a NASA U-2 (ER-2) aircraft are described. The LASE measurement objectives are listed, and the design of the LASE instrument is discussed, including performance criteria for the laser transmitter, wavemeter, telescope, optical receiver, and associated electronics. The instrument function is depicted with a block diagram, and layouts of various components are presented.

Vaughan, W. R.↗

Performances Of Fixed-Lag Phase-Smoothing Algorithms

Report discusses performances of fixed-lag nonlinear smoothing algorithms applied to estimation of phase and frequency of sinusoidal carrier signal with process phase noise and additive observation phase noise. Algorithm of type considered functions as suboptimal filter operating on received signal. Algorithm developed for system in which signal sampled at discrete times. Process noise assumed to be Gaussian with zero mean and independent of observation noise. Nonlinear smoothing equations derived in customary matrix-and-vector forms.

Kumar, Rajendra↗

Integrated Advanced Microwave Sounding Unit-A(AMSU-A). Performance Verification Report: METSAT AMSU-A2 Receiver Assembly, (P/N 1356441-1, S.N F04) S/N 107

The AMSU-A receiver subsystem comprises two separated receiver assemblies; AMSU-Al and AMSU-A2(PN1356441-1). The AMSU-A1 receiver contains 13 channels and the AMSU-A2 receiver 2 channels. The AMSU-AL receiver assembly is further divided into two parts; AMSU-A 1-1 (P/N 1356429-1) and AMSU-A 1-2 (P/N 1356409-1), which contain 9 and 4 channels, respectively. The AMSU-A receiver subsystem stands in between the antenna and signal processing subsystems of the AMSU-A instrument and comprises the RF and IF components from RF isolators to IF attenuators. It receives the RF signals from the antenna subsystem, down-converts the RF signals to IF signals, amplifies and defines the IF signals to proper power level and frequency bandwidth as specified for each channel, and inputs the IF signals to the signal processing subsystem. The test reports for the METSAT AMSU-A receiver subsystem are prepared separately for the A1 and A2 receivers so that each receiver stands alone during integration of instruments into the spacecraft. This test report presents the test data of the METSAT AMSU-A2 Flight Model No.4 (FM4) receiver. The tests are performed per the Acceptance Test Procedure for the AMSU-A Receiver Subsystem, AE-26002/6A. The functional performance tests are conducted either at the component or subsystem level. While the component-level tests are performed over the entire operating temperature range predicted by thermal analysis, the subsystem-level tests are conducted at ambient temperature only.

Kapper, R.↗

Effects of chronic lesions of the anteroventral third ventricle region on baroreceptor reflex function in conscious rats

This study determined baroreceptor reflex (BR) function in conscious rats which had received sham or electrolytic lesions of the anteroventral third ventricle (AV3V) 54-56 days previously. Resting mean arterial pressure (MAP) and heart rate (HR) values of the AV3V-lesion rats were similar to those of sham-lesion rats (P>0.05 for both comparisons). The sensitivity of the BR-mediated tachycardia in AV3V-lesion was greater than in sham-lesion rats (-9. 92+/-1.00 vs. -4.54+/-0.45 bpm/mmHg, P<0.05). The sensitivity of the BR-mediated bradycardia in AV3V-lesion rats was also greater than in rats with sham lesions (-3.56+/-0.38 vs. -2.06+/-0.42 bpm/mmHg, P<0. 05). The AV3V lesions did not affect other BR parameters. These findings demonstrate that chronic lesions of the AV3V region increase the sensitivity of the baroreceptor HR reflex in conscious rats. Copyright 1999 Published by Elsevier Science B.V.

Non-NASA Center↗

Measuring Ultrasonic Acoustic Velocity in a Thin Sheet of Graphite Epoxy Composite

A method for measuring the acoustic velocity in a thin sheet of a graphite epoxy composite (GEC) material was investigated. This method uses two identical acoustic-emission (AE) sensors, one to transmit and one to receive. The delay time as a function of distance between sensors determines a bulk velocity. A lightweight fixture (balsa wood in the current implementation) provides a consistent method of positioning the sensors, thus providing multiple measurements of the time delay between sensors at different known distances. A linear fit to separation, x, versus delay time, t, will yield an estimate of the velocity from the slope of the line.

Source record↗

Deriving Snow-Cover Depletion Curves for Different Spatial Scales from Remote Sensing and Snow Telemetry Data

During the melting of a snowpack, snow water equivalent (SWE) can be correlated to snow-covered area (SCA) once snow-free areas appear, which is when SCA begins to decrease below 100%. This amount of SWE is called the threshold SWE. Daily SWE data from snow telemetry stations were related to SCA derived from moderate-resolution imaging spectro radiometer images to produce snow-cover depletion curves. The snow depletion curves were created for an 80,000 sq km domain across southern Wyoming and northern Colorado encompassing 54 snow telemetry stations. Eight yearly snow depletion curves were compared, and it is shown that the slope of each is a function of the amount of snow received. Snow-cover depletion curves were also derived for all the individual stations, for which the threshold SWE could be estimated from peak SWE and the topography around each station. A stations peak SWE was much more important than the main topographic variables that included location, elevation, slope, and modelled clear sky solar radiation. The threshold SWE mostly illustrated inter-annual consistency.

snow depletion curves↗

Portable Medical Diagnosis Instrument

A system that integrates several technologies into a single, portable medical diagnostic apparatus for analyzing a sample body fluid (liquid and/or gas): (1) a mechanism to capture airborne microdroplets and to separate the body fluid into a first fluid component (primarily gas) and a second fluid component (primarily liquid); (2) a volatilizer to convert a portion of the second fluid component into a third fluid component that is primarily a gas; (3) a functionalized nanostructure (NS) array configured to receive, identify, and estimate concentration of at least one constituent in the first and/or third fluid components; (4) a miniaturized differential mobility spectrometer (DMS) module; and (5) a biomarker sensor, to detect volatile and non-volatile molecules in a sample fluid, which may contain one or more components of blood, breath, perspiration, saliva, and urine.

Straume, Tore↗

Method and apparatus for treatment planning using implanted radioactive seeds

A pre-computed sensitivity function providing ex ante assessment of optimal placement of a single radioactive seed, is used for sequential placement of multiple radioactive seeds. The location of each successive seed may also be constrained by an exclusion function omitting areas in the target receiving a pre-defined dose from the preexisting seeds. This technique makes possible optimization of additional dimensions of treatment planning including using a different number of needles and using mixed seed types.

62 RADIOLOGY AND NUCLEAR MEDICINE↗