Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “receiver”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Performance of a Nomogram Predicting Disease-Specific Survival After an R0 Resection for Gastric Cancer in Patients Receiving Postoperative Chemoradiation Therapy

Purpose: The internationally validated Memorial Sloan-Kettering Cancer Center (MSKCC) gastric carcinoma nomogram was based on patients who underwent curative (R0) gastrectomy, without any other therapy. The purpose of the current study was to assess the performance of this gastric cancer nomogram in patients who received chemoradiation therapy after an R0 resection for gastric cancer. Methods and Materials: In a combined dataset of 76 patients from the Netherlands Cancer Institute (NKI), and 63 patients from MSKCC, who received postoperative chemoradiation therapy (CRT) after an R0 gastrectomy, the nomogram was validated by means of the concordance index (CI) and a calibration plot. Results: The concordance index for the nomogram was 0.64, which was lower than the CI of the nomogram for patients who received no adjuvant therapy (0.80). In the calibration plot, observed survival was approximately 20% higher than the nomogram-predicted survival for patients receiving postoperative CRT. Conclusions: The MSKCC gastric carcinoma nomogram significantly underpredicted survival for patients in the current study, suggesting an impact of postoperative CRT on survival in patients who underwent an R0 resection for gastric cancer, which has been demonstrated by randomized controlled trials. This analysis stresses the need for updating nomograms with the incorporation of multimodal strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Positron Emission Tomography/Computed Tomography Findings During Therapy Predict Outcome in Patients With Diffuse Large B-Cell Lymphoma Treated With Chemotherapy Alone but Not in Those Who Receive Consolidation Radiation

Purpose: To assess the value of mid-therapy positron emission tomography (PET) findings for predicting survival and disease progression in patients with diffuse large B-cell lymphoma, considering type of therapy (chemotherapy with or without radiation therapy). Methods and Materials: We retrospectively evaluated 294 patients with histologically confirmed diffuse large B-cell lymphoma with respect to age, sex, disease stage, International Prognostic Index score, mid-therapy PET findings (positive or negative), and disease status after therapy and at last follow-up. Overall survival (OS) and progression-free survival (PFS) were compared according to mid-therapy PET findings. Results: Of the 294 patients, 163 (55%) were male, 144 (49%) were age >61 years, 110 (37%) had stage I or II disease, 219 (74%) had International Prognostic Index score ≤2, 216 (73%) received ≥6 cycles of rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisone, and 88 (30%) received consolidation radiation therapy. Five-year PFS and OS rates were associated with mid-therapy PET status: PFS was 78% for those with PET-negative (PET−) disease versus 63% for PET-positive (PET+) disease (P=.024), and OS was 82% for PET− versus 62% for PET+ (P<.002). These associations held true for patients who received chemotherapy only (PFS 71% for PET− vs 52% PET+ [P=.012], OS 78% for PET− and 51% for PET+ [P=.0055]) but not for those who received consolidation radiation therapy (PFS 84% PET− vs 81% PET+ [P=.88]; OS 90% PET− vs 81% PET+ [P=.39]). Conclusion: Mid-therapy PET can predict patient outcome, but the use of consolidation radiation therapy may negate the significance of mid-therapy findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Associations of ATM Polymorphisms With Survival in Advanced Esophageal Squamous Cell Carcinoma Patients Receiving Radiation Therapy

Purpose: To investigate whether single nucleotide polymorphisms (SNPs) in the ataxia telangiectasia mutated (ATM) gene are associated with survival in patients with esophageal squamous cell carcinoma (ESCC) receiving radiation therapy or chemoradiation therapy or surgery only. Methods and Materials: Four tagSNPs of ATM were genotyped in 412 individuals with clinical stage III or IV ESCC receiving radiation therapy or chemoradiation therapy, and in 388 individuals with stage I, II, or III ESCC treated with surgery only. Overall survival time of ESCC among different genotypes was estimated by Kaplan-Meier plot, and the significance was examined by log-rank test. The hazard ratios (HRs) and 95% confidence intervals (CIs) for death from ESCC among different genotypes were computed by a Cox proportional regression model. Results: We found 2 SNPs, rs664143 and rs664677, associated with survival time of ESCC patients receiving radiation therapy. Individuals with the rs664143A allele had poorer median survival time compared with the rs664143G allele (14.0 vs 20.0 months), with the HR for death being 1.45 (95% CI 1.12-1.89). Individuals with the rs664677C allele also had worse median survival time than those with the rs664677T allele (14.0 vs 23.5 months), with the HR of 1.57 (95% CI 1.18-2.08). Stratified analysis showed that these associations were present in both stage III and IV cancer and different radiation therapy techniques. Significant associations were also found between the SNPs and locosregional progression or progression-free survival. No association between these SNPs and survival time was detected in ESCC patients treated with surgery only. Conclusion: These results suggest that the ATM polymorphisms might serve as independent biomarkers for predicting prognosis in ESCC patients receiving radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The thirty gigahertz instrument receiver for the Q-U-I Joint Tenerife experiment: Concept and experimental results

This paper presents the analysis, design, and characterization of the thirty gigahertz instrument receiver developed for the Q-U-I Joint Tenerife experiment. The receiver is aimed to obtain polarization data of the cosmic microwave background radiation from the sky, obtaining the Q, U, and I Stokes parameters of the incoming signal simultaneously. A comprehensive analysis of the theory behind the proposed receiver is presented for a linearly polarized input signal, and the functionality tests have demonstrated adequate results in terms of Stokes parameters, which validate the concept of the receiver based on electronic phase switching.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crustal structure beneath two seismic stations in the Sunda-Banda arc transition zone derived from receiver function analysis

We analyzed receiver functions to estimate the crustal thickness and velocity structure beneath two stations of Geofon (GE) network in the Sunda-Banda arc transition zone. The stations are located in two different tectonic regimes: Sumbawa Island (station PLAI) and Timor Island (station SOEI) representing the oceanic and continental characters, respectively. We analyzed teleseismic events of 80 earthquakes to calculate the receiver functions using the time-domain iterative deconvolution technique. We employed 2D grid search (H-κ) algorithm based on the Moho interaction phases to estimate crustal thickness and Vp/Vs ratio. We also derived the S-wave velocity variation with depth beneath both stations by inverting the receiver functions. We obtained that beneath station PLAI the crustal thickness is about 27.8 km with Vp/Vs ratio 2.01. As station SOEI is covered by very thick low-velocity sediment causing unstable solution for the inversion, we modified the initial velocity model by adding the sediment thickness estimated using high frequency content of receiver functions in H-κ stacking process. We obtained the crustal thickness is about 37 km with VP/Vs ratio 2.2 beneath station SOEI. We suggest that the high Vp/Vs in station PLAI may indicate the presence of fluid ascending from the subducted plate to the volcanic arc, whereas the high Vp/Vs in station SOEI could be due to the presence of sediment and rich mafic composition in the upper crust and possibly related to the serpentinization process in the lower crust. We also suggest that the difference in velocity models and crustal thicknesses between stations PLAI and SOEI are consistent with their contrasting tectonic environments.

58 GEOSCIENCES↗

Thermal shock resistance of multilayer silicon carbide receiver tubes for 800°C molten salt concentrating solar power application

CSP power tower receiver systems during rapid transient weather periods can be vulnerable to thermal shock conditions from rain that which can facilitate the onset of leaks and failures that can have catastrophic consequences. Silicon carbide (SiC) materials have attractive receiver application characteristics for being light weight, having high-strength and excellent thermal shock resistance performance which make them a particularly good fit for receiver absorber materials in CSP. In this investigation, the performance characteristics of Ceramic Tubular Products (CTP) SiC ceramic matrix composite (CMC), multilayered tubes were explored with respect to thermal shock performance for solar receiver applications in next generation CSP plants. Here, thermal shock testing was performed at the Sandia National Laboratories (SNL) Solar Furnace facility using a dynamic stage and thermal shock tube test setup. The tubes tested under incident solar heat flux of 100 W/cm2 were heated with inner tube temperatures reaching approximately 800 °C, with outer temperatures exceeding or just reaching 1000 El for the multilayer and monolithic SiC tubes respectively. The tubes were then quenched with simulated rain. The tubes were then cooled and subjected to hoop stress analysis using an Instron device to assess their subsequent mechanical strength. Furthermore, the on-sun study experimental results indicate an average of 24.2% and 97% higher hoop strength for the CMC tubes than those composed of monolithic SiC and aluminum oxide (A1203) respectively.

14 SOLAR ENERGY↗

GaN-based W-band receiver chip development for fusion plasma diagnostics

Millimeter-wave diagnostics have proven effective on various magnetic fusion devices worldwide, yet the formidable challenges posed by the harsh environments of future burning plasma devices, characterized by extreme temperatures, pressures, and radiation levels, remain a significant hurdle. To address these challenges, the utilization of wide bandgap Gallium Nitride (GaN)-based millimeter-wave diagnostics is a most promising solution for fusion reactor safety monitoring and control. A noteworthy W-band GaN-based system-on-chip receiver has been the demonstrated by employing HRL T3 40 nm GaN technology. This receiver chip, compactly designed with dimensions of 3 × 5 mm 2 , incorporates essential components such as the 75–110 GHz RF Low-Noise Amplifier (LNA), mixer, Intermediate Frequency (IF) amplifier, and Local Oscillator (LO) chain. This receiver chip will be packaged as a millimeter-wave receiver module and applied on the DIII-D National Fusion Facility, for fusion plasma edge shape monitoring for operational safety and dangerous disruption prediction. The laboratory measurement results have demonstrated suitable performance. Furthermore, this advancement is pivotal for accurate analysis of plasma behavior in the extreme conditions of burning plasma devices, driving progress in fusion research and technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of Solar Receiver Performance for Chemical-Looping Integration With a Concentrating Solar Thermal System

This paper introduces a chemical-looping configuration integrated with a concentrating solar thermal (CST) system. The CST system uses an array of mirrors to focus sunlight, and the concentrated solar flux is applied to a solar receiver to collect and convert solar energy into thermal energy. The thermal energy then drives a thermal power cycle for electricity generation or provides an energy source to chemical processes for material or fuel production. Considerable interest in CST energy systems has been driven by power generation, with its capability to store thermal energy for continuous electricity supply or peak shaving. However, CST systems have other potential to convert solar energy into fuel or to support thermochemical processes. Thus, we introduce the concept of a chemical-looping configuration integrated with the CST system that has potential applications for thermochemical energy storage or solar thermochemical hydrogen production. The chemical-looping configuration integrated with a CST system consists of the following: a solar-receiver reactor for solar-energy collection and conversion, thermochemical energy storage, a reverse reactor for energy release, and system circulation. We describe a high-temperature reactor receiver that is a key component in the chemical-looping system. We also show the solar-receiver design and its performance analyzed by solar-tracing and thermal-modeling methods for integration within a CST system.

14 SOLAR ENERGY↗

Mass, height of burst, and source–receiver distance constraints on the acoustic coda phase delay method

Here, this research uses the acoustic coda phase delay method to estimate relative changes in air temperature between explosions with varying event masses and heights of burst. It also places a bound on source–receiver distance for the method. Previous studies used events with different shapes, height of bursts, and masses and recorded the acoustic codas at source–receiver distances less than 1 km. This research further explores the method using explosions that differ in mass (by up to an order of magnitude) and are placed at varying heights. Source–receiver distances also cover an area out to 7 km. Relative air temperature change estimates are compared to complementary meteorological observations. Results show that two explosions that differ by an order of magnitude cannot be used with this method because their propagation times in the near field and their fundamental frequencies are different. These differences are expressed as inaccuracies in the relative air temperature change estimates. An order of magnitude difference in mass is also shown to bias estimates higher. Small differences in height of burst do not affect the accuracy of the method. Finally, an upper bound of 1 km on source–receiver distance is provided based on the standard deviation characteristics of the estimates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Annual Efficiencies of High Temperature Central Receiver Concentrated Solar Power Plants With Thermal Energy Storage

The current study has examined four cases of a central receiver concentrated solar power plant with thermal energy storage using the DELSOL and SOLERGY computer codes. The current state-of-the-art base case was compared with a theoretical high temperature case which was based on the scaling of some input parameters and the estimation of other parameters based on performance targets from the Department of Energy SunShot Initiative. This comparison was done for both current and high temperature cases in two configurations: a surround field with an external cylindrical receiver and a north field with a single cavity receiver. There is a fairly dramatic difference between the design point and annual average performance, especially in the solar field and receiver subsystems, and also in energy losses due to the thermal energy storage being full to capacity. Additionally, there are relatively small differences (<2%) in annual average efficiencies between the Base and High Temperature cases, despite an increase in thermal to electric conversion efficiency of over 8%. This is due the increased thermal losses at higher temperature and operational losses due to subsystem start-up and shut-down. Thermal energy storage can mitigate some of these losses by utilizing larger thermal energy storage to ensure that the electric power production system does not need to stop and re-start as often, but solar energy is inherently transient. Economic and cost considerations were not considered here, but will have a significant impact on solar thermal electric power production strategy and sizing.

Ehrhart, Brian David↗

Central Receiver Optimization

Sandia National Laboratories (Sandia) and the Commonwealth Scientific and Industrial Research Organisation (CSIRO) collaborated to optimize central receivers in the temperature range of 600-900°C suitable for advanced power cycles. It was recognized that significant cost reductions can be made in concentrating solar power (CSP) if efficiency was substantially improved. Advanced cycles such as supercritical CO 2 (sCO 2 ) power cycles offer the potential for high efficiency, but the solar collector and receiver geometry must be considered together to ensure the required inlet conditions for the turbine can be met in a cost-effective manner. This project investigated heliostat life cycle costs, heliostat field layout and associated receiver geometry to better understand the optical and thermodynamic relationship between these components in this temperature range of interest, allowing subsequent optimization. This work will assist the mission of Sandia, the Department of Energy (DOE), and CSIRO to develop sustainable, cost-competitive energy technologies for public use. The purpose of this work was to investigate factors affecting performance and costs of heliostats, including in-field heliostat testing. Alternative receiver designs designed to achieve high temperatures (900 °C and above) were also explored in conjunction with the heliostat field.

Ho, Clifford K.↗

Continuation Report: Creep-fatigue Behavior and Damage Accumulation of a Candidate Structural Material for Concentrating Solar Thermal Receiver

At the start of this phase, six alloys were determined to be candidate materials for the concentrating solar power (CSP) thermal receiver: Alloys 617, 625, 740H, 230, 282 and Alloy X. From these, Alloys 740H and 282 were determined to be the most suitable, with both alloys exhibiting similar high temperature strength properties. Alloy 740H was selected due to its ease to work with (simpler heat treatments and welding procedures) and a larger database of existing data. Fatigue testing was started in this phase, with four fatigue tests having been completed, with additional fatigue testing planned, as well as tensile, creep and creep-fatigue tests starting in the next phase. Two fatigue tests performed at 850 °C and were completed in significantly fewer cycles than the two tests performed at 750 °C. Metallography was performed on the fatigued specimens to examine crack path and surrounding microstructure. These preliminary results suggest a significant drop in strength at elevated temperatures above 750 °C, however, more test results will be needed prior to setting design limits. Several potential model high temperature design methods were evaluated that could form the basis of our final recommended creep-fatigue design method for Alloy 740H. To do this we expanded on the receiver finite element model to develop a model representative of a potential Gen 3 design using KCl-MgCl2 salt coolant and operating with a salt inlet temperature of 550°C and salt outlet temperature of 720°C. Using the temperature fields from the model thermohydraulic analysis we determined the design life of the reference receiver assuming it was constructed from 740H seamless tubing and assuming high temperature design properties for 740H from literature data and, where required, naïve extrapolation. As experimental data is generated, these tentative design parameters will be updated to match the actual performance of 740H in elevated temperature service. The results of this design study are a rank ordering of potential design methods for two criteria: ease of use and design margin. The end goal of this project is to develop a creep-fatigue design method with adequate, but not over conservative, design margin that is straightforward to execute. Our receiver model is based on the preliminary design provided to DOE by Solar Reserve. Our analysis indicates a peak metal temperature of around 840° C for this design (comparable to Solar Reserve’s analysis, which shows a peak metal temperature of around 830° C). The Solar Reserve tube thickness is too thin to sustain creep-fatigue loading at this temperature. This means that the current trial design is not well-suited for evaluating different design methodologies, as we predict it will have a very short design life. We suggest that we modify our reference design with input from DOE in order to lower the maximum metal temperature to less than 800° C. We can then repeat these analyses and give a more meaningful comparison of different design methods before making a final selection.

14 SOLAR ENERGY↗

Abrasion wear at high temperature in particle receiver type Concentrating Solar Power Systems

The use of solid particles as a heat transfer fluid in receivers for concentrating solar powerplants has garnered much attention in the past decade. Particles are not only stable at temperatures above 700 °C but are also able to absorb solar energy directly, which gives them a distinct advantage over conventional molten salts. The use of particles can, however, cause material degradation from the flow of hot or cold particles through discharge hoppers or along the inner receiver surfaces and other system components (e.g. tubes, valves etc.), depending on operating mode of the receiver. Stainless steel alloy 316, nickel-based alloy Inconel® 740H®, Haynes 230, and a 60% alumina, low-cement refractory castable from Allied Mineral Products were tested for wear from first-of-a-kind high-temperature low-velocity abrasion-erosion experiments. The tests are designed to simulate potential conditions in Generation 3 falling particle Concentrating Solar Power (CSP) systems. Simultaneous experiments were conducted at room temperature as well to draw comparison on the role of temperature on abrasion wear rates. It was noted that the abrasion wear rate in candidate materials was driven by the oxidation resistance of the material. The findings from these experiments will be used to determine life-time of critical components in particle receiver concentrated solar powerplants.

14 SOLAR ENERGY↗

Volumetrically Absorbing Thermal Insulator (VATI) for High-temperature Receivers

This project seeks to exploit volumetric absorption of concentrated solar irradiation in a thin, high-temperature, thermally conductive medium. High efficiency thermal conversion is achieved by volumetric absorption of both incoming solar irradiation (short wavelength) and emitted irradiation (long wavelength), demonstrating a volumetrically absorbing thermally insulating (VATI) effect. The thermalized energy is conducted to the back wall, enclosing the working fluid (molten salt or supercritical CO 2 ). Reliance on conductive thermal transport requires a thermally conductive medium, in the absence of which large temperature gradients drive losses due to emission. The project’s outcomes are important to realize a cost-effective approach to reduce optical and thermal losses from CSP receivers at high temperatures (720°C). High-temperature stable and commercially available porous SiC structures (open-cell foams) were explored as a volumetrically absorbing and thermally insulating layer. To the best of our knowledge, the current state-of-the-art for industrially deployed coatings is Pyromark. However, Pyromark suffers degradation at 700+°C and diurnal temperature changes. This necessitates periodic recoating, and the downtime increases the overall levelized cost of energy (LCOE) production. On the other hand, contemporary research activities have generated significant advances in the development of selective emitter coatings, which present challenges with costs, scalability, and stability. The pursued approach alleviates these concerns by developing a receiver that utilizes the inherent structure of high-temperature stable porous materials to enable robust and cost-effective receivers which require no periodic maintenance downtimes. The overall goal of the project is to experimentally demonstrate a figure of merit (FOM) of 0.92 at a temperature of 720°C and solar irradiation of 1000x concentration with porous receivers. The relevant crystallographic (phase) optical and thermal properties of porous SiC were first characterized. Second, the 3-D geometry of the porous SiC was analyzed using micro-X-ray tomography and converted to CAD data using image processing analysis. Utilizing this 3-D geometry and relevant optical/thermal properties, Monte Carlo- Ray Tracing (MCRT) analysis was performed to extract important parameters governing solar-thermal energy conversion such as extinction coefficient (β, 1/m), scattering albedo (ω) and the scattering phase function (Φ). These properties were then integrated into an in-house radiative and conduction transport model to solve for temperature and transport fluxes characterizing the solar-thermal energy conversion. This model was utilized to predict the FOM for various SiC porous geometries and to identify the highest possible FOM. Testing of the optimized porous structures will be accomplished with a custom-built high-accuracy (< ±4%) FOM measurement test-stand and a 1000x solar concentrator. When neglecting convective losses and resistance at the open boundary and the back wall, the optimized SiC foam leads to a FOM of 0.84. This FOM does not surpass the performance of Pyromark 2500. Yet, conversely to Pyromark 2500, SiC is stable at high temperatures and does not degrade over time. Also, it is possible to boost the FOM of SiC by engineering its effective thermal conductivity and its scattering albedo. A FOM of 0.92 is predicted for an optimized foam by accounting for convective losses and resistance at the open boundary and the back wall. This largely exceeds the FOM of Pyromark 2500 (~0.86) predicted by neglecting convective losses and resistance. Therefore, further engineering of the foam could lead to unprecedented FOMs.

14 SOLAR ENERGY↗

High Flux Microchannel Receiver Development (Final Report)

The opportunity addressed in this project was using microscale heat exchanger technology for improving solar thermal central receiver efficiency. This will result in smaller, less expensive components and reduce the levelized cost of electricity from concentrated solar thermal power. This micro-pin solar receiver (MSR) directly heats high pressure (25 MPa) supercritical carbon dioxide (sCO 2 ) from 550°C to 720°C with an incident flux of at least 120 W/cm 2 at a receiver efficiency of >90% (assuming availability of 95% absorptivity coating), and receiver cost target of less than $\$$150/kWt. Realization of the MSR required an understanding of thermal hydraulic performance of sCO 2 in micro-pin passages, mechanical behavior of high nickel alloys at high temperatures including joints, advanced fabrication methods of high nickel alloys (etching, machining, brazing, welding, diffusion bonding), and the cost implications of these when the concept is scaled to production volumes. The technology can be used with gases (sCO 2 , helium, etc.) or with liquids such as molten salt or liquid metal. Given the high pressure associated with sCO 2 , its use demonstrates a “worst case” scenario, and the successful development of the MSR for this application will result in the development of a technology also applicable to a range of other heat transfer fluids that will enable next generation CSP plants, including support of the Gen3CSP program.

14 SOLAR ENERGY↗

Technoeconomics of Particle-based CSP Featuring Falling Particle Receivers with and without Active Heliostat Control

This report documents the results and conclusions of a recent project to understand the technoeconomics of utility-scale, particle-based concentrating solar power (CSP) facilities leveraging unique operational strategies. This project included two primary objectives. The first project objective was to build confidence in the modeling approaches applied to falling particle receivers (FPRs) including the effect s of wind. The second project objective was to create the necessary modeling capability to adequately predict and maximize the annual performance of utility-scale, particle-based CSP plants under anticipated conditions with and without active heliostat control. Results of an extensive model validation study provided the strongest evidence to date for the modeling strategies typically applied to FPRs, albeit at smaller receiver scales. This modeling strategy was then applied in a parametric study of candidate utility-scale FPRs, including both free-falling and multistage FPR concepts, to develop reduced order models for predicting the receiver thermal efficiency under anticipated environmental and operating conditions. Multistage FPRs were found to significantly improve receiver performance at utility-scales. These reduced order models were then leveraged in a sophisticated technoeconomic analysis to optimize utility-scale , particle-based CSP plants considering the potential of active heliostat control. In summary, active heliostat control did not show significant performance benefits to future utility-scale CSP systems though some benefit may still be realized in FPR designs with wide acceptance angles and/or with lower concentration ratios. Using the latest FPR technologies available, the levelized-cost of electricity was quantified for particle-based CSP facilities with nominal powers ranging from 5 MW e up to 100 MW e with many viable designs having costs < 0.06 $/kWh and local minimums occurring between ~25–35 MW e .

14 SOLAR ENERGY↗

Shaping High Efficiency, High Temperature Cavity Tubular Solar Central Receivers

High temperature solar receivers are developed in the context of the Gen3 solar thermal power plants, in order to power high efficiency heat-to-electricity cycles. Since particle technology collects and stores high temperature solar heat, CNRS (French National Center for Scientific Research) develops an original technology using fluidized particles as HTF (heat transfer fluid). The targeted particle temperature is around 750 °C, and the walls of the receiver tubes, reach high working temperatures, which impose the design of a cavity receiver to limit the radiative losses. Therefore, the objective of this work is to explore the cavity shape effect on the absorber performances. Geometrical parameters are defined to parametrize the design. The size and shape of the cavity, the aperture-to-absorber distance and its tilt angle. A thermal model of a 50 MW hemi-cylindrical tubular receiver, closed by refractory panels, is developed, which accounts for radiation and convection losses. Parameter ranges that reach a thermal efficiency of at least 85% are explored. This sensitivity analysis allows the definition of cavity shape and dimensions to reach the targeted efficiency. For an aperture-to-absorber distance of 9 m, the 85% efficiency is obtained for aperture areas equal or less than 20 m2 and 25 m2 for high, and low convection losses, respectively.

Gueguen, Ronny (ORCID:0000000252368638)↗

Design Evaluation of a Next-Generation High-Temperature Particle Receiver for Concentrating Solar Thermal Applications

High-temperature particle receivers are being developed to achieve temperatures in excess of 700 °C for advanced power cycles and solar thermochemical processes. This paper describes designs and features of a falling particle receiver system that has been evaluated and tested at the National Solar Thermal Test Facility at Sandia National Laboratories. These advanced designs are intended to reduce heat losses and increase the thermal efficiency. Novel features include aperture covers, active air flow, particle flow obstructions, and optimized receiver shapes that minimize advective heat losses, increase particle curtain opacity and uniformity, and reduce cavity wall temperatures. Control systems are implemented in recent on-sun tests to maintain a desired particle outlet temperature using an automated closed-loop proportional–integral–derivative controller. These tests demonstrate the ability to achieve and maintain particle outlet temperatures approaching 800 °C with efficiencies between 60 and 90%, depending on incident power, mass flow, and environmental conditions. Lessons learned regarding the testing of design features and overall receiver operation are also presented.

Mills, Brantley H.↗