Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “range measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Thermal Cross Section Measurements At The RPI LINAC

Recently, a cold moderator was designed and developed for use at the Rensselaer Polytechnic Institute Linear Accelerator (RPI LINAC). This cold moderator proved to easily and safely couple to an existing neutron producing target, while enhancing neutron flux below 0.02 eV by up to a factor of 8 by cooling polyethylene down to 29 K. This cold moderator capability allowed for significantly improved counting statistics below 0.02 eV not previously possible due to a poor signal to background ratio. Additionally, testing was performed to characterize the energy resolution of the new cold moderator system and found the system easily capable of resolving resonances in Ta-181 at 4 and 10 eV, while also clearly resolving the Bragg edges found in Be metal below 0.01 eV. Furthermore, following the design and development of a cold polyethylene moderator, a series of thermal total cross section measurements were performed for polyethylene, polystyrene, Plexiglas and yttrium hydride in the thermal region. These measurements serve to help validate thermal scattering law (TSL) evaluations in the 0.0005 – 1 eV energy range. For polyethylene and polystyrene, two sets of experiments were performed – one with the Enhanced Thermal Target (ETT) and another with the ETT plus the new cold moderator capability (ETTC). The yttrium hydride and Plexiglas measurements were only performed with the ETTC. The measurements for polyethylene help to validate the data processing methodology when using the ETTC, while extending the measured range of polyethylene down to 0.0005 eV. Two different Plexiglas, Plexiglas G and Plexiglas G-UVT, and two different concentrations of yttrium hydride, H/Y = 1.85 and 1.68, were measured. Overall, all materials had generally good agreement with their ENDF/B-VIII.0 TSL evaluations, though some discrepancies were noticed. In the case of the yttrium hydride, the high energy oscillations in the hydrogen cross section and the low energy Bragg edges in the yttrium cross section were clearly seen. These measurements represent the first total cross section measurements that encompass the entire thermal region from 0.0005 – 1 eV for polystyrene and yttrium hydride.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal cross section measurements at the RPI LINAC [Abstract]

Recently, a cold moderator was designed and developed for use at the RPI LINAC. This cold moderator proved to easily and safely couple to an existing neutron producing target, while enhancing neutron flux below 0.02 eV by cooling polyethylene down to 29 K. This cold moderator capability allowed for significantly improved counting statistics below 0.02 eV not previously possible due to a poor signal to background ratio. Additionally, testing was performed to characterize the energy resolution of the new cold moderator system and found the system easily capable of resolving resonances in Ta-181 at 4 and 10 eV, while also clearly resolving the Bragg edges found in Be metal below 0.01 eV. Following the design and development of a cold polyethylene moderator, a series of thermal total cross section measurements were performed for polyethylene, polystyrene, Plexiglas and yttrium hydride in the thermal region. These measurements serve to help validate thermal scattering law (TSL) evaluations in the 0.0006 – 20 eV energy range. For polyethylene and polystyrene, two sets of experiments were performed – one with the Enhanced Thermal Target (ETT) and another with the ETT plus the new cold moderator capability (ETTC). The yttrium hydride and Plexiglas measurements were only performed with the ETTC. The measurements for polyethylene help to validate the data processing methodology when using the ETTC, while extending the measured range of polyethylene down to 0.0007 eV. Two different Plexiglas, Plexiglas G and Plexiglas G-UVT, and two different concentrations of yttrium hydride, H/Y = 1.85 and 1.68, were measured. Overall, all materials had generally good agreement with their ENDF/B-VIII.0 TSL evaluations, though some discrepancies were noticed. In the case of the yttrium hydride, the high energy oscillations in the hydrogen cross section and the low energy Bragg edges in the yttrium cross section were clearly seen. These measurements represent the first total cross section measurements that encompass the entire thermal region from 0.0006 – 3 eV for polystyrene and yttrium hydride.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Joint Theoretical and Experimental Study of the Electronic, Magnetic, and Lattice Phonon Dynamics Properties of Ca x Fe y O z Compounds Applied to CO 2 Capture

Unleashing energy innovation ensures a resilient and reliable energy supply. There is a critical need for the development of new carbon dioxide (CO 2 ) captors that have improved energy efficiency accompanied by lower capital and operational costs to ensure abundant, affordable, and secure energy. Among solid materials, CaO is a good CO 2 sorbent for capture technology due to its wide availability and low cost. However, CaO also suffers from some disadvantages, such as high calcination temperature, decreasing capability due to sintering, attrition, and reaction with SO x and NO x . In this study, we employed an ab initio thermodynamic approach and experimental measurements to improve its CO 2 capture performance during the cycles. To do so, we explored the electronic, magnetic, and lattice dynamic properties of a series of calcium ferrites (Ca x Fe y O z ) and applied them for CO 2 capture. Our results showed that all of them can thermodynamically react with CO 2 to form CaCO 3 and iron oxides. Compared to pure CaO capturing CO 2 , CaFe 3 O 4 , CaFe 2 O 4 , and Ca 2 Fe 2 O 5 could shift the CO 2 regeneration temperature to a lower range. The experimental measurements showed that CaFeO 2 is a good CO 2 captor with or without the presence of an O 2 presence. The calculated thermodynamic properties of Ca x Fe y O z capturing the CO 2 reactions can be used to find their operational temperature ranges for different CO 2 capture technologies.

CO2 capture↗

Predicting 1 H NMR relaxation in Gd 3+ -aqua using molecular dynamics simulations

Atomistic molecular dynamics simulations are used to predict 1 H NMR T 1 relaxation of water from paramagnetic Gd 3+ ions in solution at 25 °C. Simulations of the T 1 relaxivity dispersion function r 1 computed from the Gd 3+ – 1 H dipole–dipole autocorrelation function agree within ≃8% of measurements in the range f 0 ≃ 5 ↔ 500 MHz, without any adjustable parameters in the interpretation of the simulations, and without any relaxation models. Here the simulation results are discussed in the context of the Solomon-Bloembergen-Morgan inner-sphere relaxation model, and the Hwang-Freed outer-sphere relaxation model. Below f 0 ≲ 5 MHz, the simulation overestimates r 1 compared to measurements, which is used to estimate the zero-field electron-spin relaxation time. The simulations show potential for predicting r 1 at high frequencies in chelated Gd 3+ contrast-agents used for clinical MRI.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter

Measurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb−1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Expanding the momentum field of view in angle-resolved photoemission systems with hemispherical analyzers

In photoelectron spectroscopy, the measured electron momentum range is intrinsically related to the excitation photon energy. Low photon energies <10 eV are commonly encountered in laser-based photoemission and lead to a momentum range that is smaller than the Brillouin zones of most materials. This can become a limiting factor when studying condensed matter with laser-based photoemission. An additional restriction is introduced by widely used hemispherical analyzers that record only electrons photoemitted in a solid angle set by the aperture size at the analyzer entrance. Here, we present an upgrade to increase the effective solid angle that is measured with a hemispherical analyzer. We achieve this by accelerating the photoelectrons toward the analyzer with an electric field that is generated by a bias voltage on the sample. Our experimental geometry is comparable to a parallel plate capacitor, and therefore, we approximate the electric field to be uniform along the photoelectron trajectory. With this assumption, we developed an analytic, parameter-free model that relates the measured angles to the electron momenta in the solid and verify its validity by comparing with experimental results on the charge density wave material TbTe3. By providing a larger field of view in momentum space, our approach using a bias potential considerably expands the flexibility of laser-based photoemission setups.

36 MATERIALS SCIENCE↗

Interference fringe (IF) technique for droplet contact angle and thickness measurements: Ultralow contact angle and nanoscale thickness measurement

Recently, reflection interference fringe (RIF) and transmission fringe (TIF) techniques have been introduced to investigate the origin of far-field interference fringe (IF) formation and to determine a droplet's contact angle and thickness by measuring the fringe radius. In this study, characteristics of the IF technique are analyzed based on the RIF and TIF by varying the schematics, such as configuration (transmission/reflection), the droplet's side (left-hand side/right-hand side), and the substrate types (flat/prism). The analysis also investigates the refraction effect at the droplet edge and the maximum incidence and contact angles. The schematic variation shows that the widest contact angle range can be measured in a transmission configuration with droplet's right-hand side, and that the fringe radius decreases with incidence angles on a prism substrate, consistent with the recent observation. Refraction at the droplet edge causes the fringe radius to increase or decrease depending on the degree of refraction. Based on the characteristics study, it is revealed that the IF technique can determine nanometer-scale thicknesses below 100 nm on droplets, corresponding to ultra-small contact angles of less than 0.01°, with an extended working distance of 3000 mm and an optimized incidence angle, assuming a spherical profile. This finding is significant, as it demonstrates that the nanoscale thickness can be determined in situ under ambient conditions using a simple optical configuration, without requiring a sophisticated setup, such as a microscope. It is anticipated that the IF technique can be combined with other nanoscale thickness measurement techniques to enhance its measurement reliability.

36 MATERIALS SCIENCE↗

Aqueous TiO 2 Nanoparticles React by Proton-Coupled Electron Transfer

Redox reactions of aqueous colloidal TiO 2 4 nm nanoparticles (NPs) have been examined, including both citratecapped and uncapped NPs (c-TiO 2 and uc-TiO 2 ). Photoreduction gave stable blue colloidal c-TiO 2 R NPs with 10–60 electrons per particle. Equilibration of these reduced NPs with soluble redox reagents such as methylviologen (MV 2+ ) provided measurements of the colloid reduction potential as a function of pH. The potentials of c-TiO 2 from pH 2–9 varied linearly with pH, with a slope of –60 ± 5 mV/pH. Estimates of the potential at pH 12 were consistent with extrapolating that line to high pH. The reduction potentials did not correlate with the zeta potentials (ζ) or the surface charge of the NPs across this pH range. Similar reduction potentials were observed for c- and uc-TiO 2 at low pH even though they have quite different ζ potentials. These results show that the common surface-charging explanation of the pH dependence is not tenable in these systems. Oxidation of reduced c-TiO 2 R with the electron-transfer oxidant potassium triiodide (KI 3 ) occurred with a significant drop in pH, showing that protons were released when the electrons were removed from the NPs. Smaller pH drops were observed for the proton-coupled electron transfer (PCET) reagents O 2 (air) and 4-MeO-TEMPO (4-methoxy-2,2,6,6-tetramethylpiperine-1-oxy radical). The difference in the number of protons released with KI 3 vs O 2 and 4-MeO-TEMPO was roughly one proton per electron removed. Thus, the thermodynamically preferred reactivity of these colloidal TiO 2 NPs is PCET over the pH 2–13 range studied. The measured redox potentials refer to the chemical process TiO 2 + H + + e – → TiO 2 ·e – ,H + ; and therefore they do not correspond with an electronic energy such as a conduction band edge or flat band potential. The 1e – /1H + stoichiometry means that the TiO 2 reduction potentials correspond to a TiO 2 –H bond dissociation free energy (BDFE), determined to be 49 ± 2 kcal mol –1 . The PCET description is consistent with the pH dependence of E(TiO 2 /TiO 2 ·e – ,H + ), the release of protons upon oxidation, the lack of correlation with ζ potentials, the similarity of capped and uncapped NPs, and the small change in the potential and BDFE from the first to the last electron/proton pair (H atom) removed. Furthermore, this behavior is suggested to be the norm for redox-active oxide/water interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design, upgrade and characterization of the silicon photomultiplier front-end for the AMIGA detector at the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to complement the study of ultra-high-energy cosmic rays (UHECR) by measuring the muon content of extensive air showers (EAS). It consists of an array of 61 water Cherenkov detectors on a denser spacing in combination with underground scintillation detectors used for muon density measurement. Each detector is composed of three scintillation modules, with 10 m 2 detection area per module, buried at 2.3 m depth, resulting in a total detection area of 30 m 2 . Silicon photomultiplier sensors (SiPM) measure the amount of scintillation light generated by charged particles traversing the modules. In this paper, the design of the front-end electronics to process the signals of those SiPMs and test results from the laboratory and from the Pierre Auger Observatory are described. Compared to our previous prototype, the new electronics shows a higher performance, higher efficiency and lower power consumption, and it has a new acquisition system with increased dynamic range that allows measurements closer to the shower core. The new acquisition system is based on the measurement of the total charge signal that the muonic component of the cosmic ray shower generates in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First fluctuation measurements using an Imaging Neutral Particle Analyzer on DIII-D

A recent upgrade to the Imaging Neutral Particle Analyzer (INPA) on DIII-D has allowed for the first fluctuation measurements using an INPA to be taken during a neoclassical tearing mode (NTM). The INPA signal tracked the mode over 150 ms as the mode frequency dropped to zero, capturing both the NTM with poloidal and toroidal mode numbers $m/n=2/1$ and a $3/2$ mode at double the frequency. Analysis shows that the signals originate from charge exchange events near the edge of the plasma, and relative fluctuation amplitudes are greater than 25% for the duration of the NTM. Filtered signals show frequency beating patterns that are phase-space dependent. Simulated signal is dominated by prompt transport from the neutral beams to the INPA sightline, while the contribution from the slowing down distribution is significantly lower. Simulated measurements in the range of pitches that the diagnostic is sensitive to (0.5≤|v∥/v|≤ 0.75) show the signal is dominated by trapped orbits that pass through magnetic islands near the edge of the plasma. Calculations of expected fluctuation levels show that only direct interaction with the NTM can provide the strong relative fluctuation levels seen experimentally. The prompt nature of the orbits and thin radial layer found to contribute to synthetic signals suggest INPA passive data may be used to measure the perturbations of confined orbits on a single pass through a plasma instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative analysis of the sensitivity of nanometallic thin film thermometers

Thin film platinum resistive thermometers are conventionally applied for resistance thermometry techniques due to their stability and proven measurement accuracy. Depending upon the required thermometer thickness and temperature measurement, however, performance benefits can be realized through the application of alternative nanometallic thin films. Herein, a comparative experimental analysis is provided on the performance of nanometallic thin film thermometers most relevant to microelectronics and thermal sensing applications: Al, Au, Cu, and Pt. Sensitivity is assessed through the temperature coefficient of resistance, measured over a range of 10–300 K for thicknesses nominally spanning 25–200 nm. In this work, the interplay of electron scattering sources, which give rise to the temperature-dependent TCR properties for each metal, are analyzed in the framework of a Mayadas–Shatzkes based model. Despite the prevalence of evaporated Pt thin film thermometers, Au and Cu films fabricated in a similar manner may provide enhanced sensitivity depending upon thickness. These results may serve as a guide as the movement toward smaller measurement platforms necessitates the use of smaller, thinner metallic resistance thermometers.

36 MATERIALS SCIENCE↗

Deep Direct-Use Geothermal Feasibility Study for Hawthorne NV

The Hawthorne Nevada, deep direct-use geothermal study is a two-year effort funded by the U.S. Department of Energy to determine the techno-economic feasibility of implementing a large-scale, direct-use facility for the Hawthorne Army Depot (HAD) and the public facilities of the city of Hawthorne and Mineral County. The approach links a production side analysis (PSA) and a demand side analysis (DSA) into a whole-system analysis (WSA) to provide an integrated assessment of the resource and the probability of delivering economically viable direct-use energy to Hawthorne. Hawthorne, Nevada is in the western part of the Basin and Range province and has been the focus of geothermal investigations for over 40 years. Over the last 15 years, several studies completed by the U.S. Navy Geothermal Program Office (GPO) in conjunction with industry professionals quantified the existence of several low temperature geothermal prospects, the most promising of which is called Prospect A. The promise of Prospect A is based on drilling and flow testing that produced ~100 °C water at flow rates of up to 31 l/s (500 gallons per minute). Measured productivity indexes range from 40-85 l/s/MPa, suggesting a warm and productive heat source. Despite the promise of the resource, uncertainties in its spatial extent and long-term sustainability mean that techno-economic analyses must include probabilities of the sustainability of the resource under different operating scenarios. Here, the PSA is conducted by integrating a wide range of disparate data to estimate lognormal P90, P50, and P10 resource capacities. These capacities are used as input to a thermal-hydrologic (T-H) model to estimate thermal drawdown for each capacity estimate for several different DSA scenarios. Using a systems-based approach, the WSA links the dynamic T-H simulations of the PSA/DSA combinations with the techno-economic model GEOPHIRES to account for both the temporal dynamics and uncertainties in the system to produce probabilistic distributions of several performance metrics including the levelized cost of heat (LCOH) and the return on investment (ROI). This report is the final delivery for the project and documents the study's activities and results.

15 GEOTHERMAL ENERGY↗

Complete Stokes vector analysis with a compact, portable rotating waveplate polarimeter

Accurate calibration of polarization dependent optical elements is often necessary in optical experiments. A versatile polarimeter device to measure the polarization state of light is a valuable tool in these experiments. Here we report a rotating waveplate-based polarimeter capable of complete Stokes vector analysis of collimated light. Calibration of the device allows accurate measurements over a range of wavelengths, with a bandwidth of >30 nm in this implementation. A photo-interrupter trigger system supplies the phase information necessary for full determination of the Stokes vector. An Arduino microcontroller performs rapid analysis and displays the results on a liquid crystal display. The polarimeter is compact and can be placed anywhere on an optical table on a single standard post. The components to construct the device are only a fraction of the cost of commercially available devices while the accuracy and precision of the measurements are of the same order of magnitude.

47 OTHER INSTRUMENTATION↗

Ultra-low loss visible light waveguides for integrated atomic, molecular, and quantum photonics

Atomic, molecular and optical (AMO) visible light systems are the heart of precision applications including quantum, atomic clocks and precision metrology. As these systems scale in terms of number of lasers, wavelengths, and optical components, their reliability, space occupied, and power consumption will push the limits of using traditional laboratory-scale lasers and optics. Visible light photonic integration is critical to advancing AMO based sciences and applications, yet key performance aspects remain to be addressed, most notably waveguide losses and laser phase noise and stability. Additionally, a visible light integrated solution needs to be wafer-scale CMOS compatible and capable of supporting a wide array of photonic components. While the regime of ultra-low loss has been achieved at telecommunication wavelengths, progress at visible wavelengths has been limited. Here, we report the lowest waveguide losses and highest resonator Qs to date in the visible range, to the best of our knowledge. We report waveguide losses at wavelengths associated with strontium transitions in the 461 nm to 802 nm wavelength range, of 0.01 dB/cm to 0.09 dB/cm and associated intrinsic resonator Q of 60 Million to 9.5 Million, a decrease in loss by factors of 6x to 2x and increase in Q by factors of 10x to 1.5x over this visible wavelength range. Additionally, we measure an absorption limited loss and Q of 0.17 dB/m and 340 million at 674 nm. This level of performance is achieved in a wafer-scale foundry compatible Si 3 N 4 platform with a 20 nm thick core and TEOS-PECVD deposited upper cladding oxide, and enables waveguides for different wavelengths to be fabricated on the same wafer with mask-only changes per wavelength. These results represent a significant step forward in waveguide platforms that operate in the visible, opening up a wide range of integrated applications that utilize atoms, ions and molecules including sensing, navigation, metrology and clocks.

Chauhan, Nitesh↗

Adsorption Equilibrium, Kinetics, and Column Breakthrough Data for Aqueous Solutions of Binary-Acid and Ternary-Acid Mixtures of Acetic Acid, Butyric Acid, and Lactic Acid on IRN-78 Ion-Exchange Resin at Initial pH Levels of ∼3–7 and at 25–55 °C

This work is part of an effort to develop thermophysical property data and models supporting adsorptive process development for organic acid separation from a dilute aqueous solution of fermentation broth. It presents systematic experimental measurements for aqueous-phase adsorption equilibrium, kinetics, and column breakthrough for three binary-acid aqueous mixtures (acetic acid + lactic acid, butyric acid + lactic acid, and acetic acid + butyric acid) and one ternary-acid aqueous mixture (acetic acid + butyric acid + lactic acid) on Amberlite IRN-78 ion-exchange resin. The equilibrium measurements covered broad ranges of the initial acid concentration (100–400 mmol/L), initial pH (∼3–7), and temperature (25–55 °C). The equilibrium data for the binary-acid and ternary-acid aqueous mixtures indicate selective adsorption of lactic acid at initial pH levels of ∼3 and 4, while acetic acid and butyric acid are selectively adsorbed at initial pH levels of 5, 6, and 7. The subsequent kinetics and column breakthrough experiments were performed at 200 mmol/L with equimolar ratios, an initial pH of 6, and 25 °C. In conclusion, the measurements provide essential data sets for rigorous thermodynamic modeling and process simulation of adsorptive separation processes for organic acid separation from fermentation broth.

Adsorption↗

Measurement of Υ production in pp collisions at $\sqrt{s}$ = 5 TeV

The production cross-sections of Υ mesons, namely Υ(1S), Υ(2S) and Υ(3S), in pp collisions at $\sqrt{s}$ = 5 TeV are measured with a data sample corresponding to an integrated luminosity of 9.13 ± 0.18 pb –1 collected by the LHCb detector. The Υ mesons are reconstructed in the decay mode Υ → μ + μ – . Double differential cross-sections times branching fractions, as functions of the transverse momentum p T and the rapidity y of the Υ mesons, are measured in the range p T < 20 GeV/c and 2.0 < y < 4.5. The results integrated over these p T and y ranges are $\sigma \left(\textrm{Y}(1S)\right)\times \mathcal{B}\left(\textrm{Y}(1S)\to {\mu}^{+}{\mu}^{-}\right)=2101\pm 33\pm 83\ \textrm{pb},$ $\sigma \left(\textrm{Y}(2S)\right)\times \mathcal{B}\left(\textrm{Y}(2S)\to {\mu}^{+}{\mu}^{-}\right)=526\pm 20\pm 21\ \textrm{pb},$ $\sigma \left(\textrm{Y}(3S)\right)\times \mathcal{B}\left(\textrm{Y}(3S)\to {\mu}^{+}{\mu}^{-}\right)=242\pm 16\pm 10\ \textrm{pb},$ where the first uncertainties are statistical and the second are systematic. The ratios of cross-sections between measurements of two different Υ states and between measurements at different centre-of-mass energies are determined. The nuclear modification factor of Υ(1S) at $\sqrt{s}$ = 5 TeV is updated as well using the directly measured cross-section results from this analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Groundwater flowpath characteristics drive variability in per- and polyfluoroalkyl substances (PFAS) loading across a stream-wetland system

Groundwater dependent ecosystems in areas with industrial and military land use are at risk of direct exposure to a wide range of contaminants, including PFAS chemicals. Glaciated terrain often has mixed high and low permeability sediments coupled with groundwater flow-through lake features. These hydrogeologic attributes create highly complex ‘source to seep’ dynamics that make spatiotemporal contaminant transport patterns difficult to predict. We investigated one such system in detail using a suite of heat-tracing and chemical methods. Numerous (n=57) preferential groundwater discharge zones (vertical flux rates ranging 0.2 to 3.2 m/d) were identified across the upper Quashnet River stream-wetland system in Mashpee, MA, USA, adjacent to an Air Force Base with several known PFAS source areas. Surface-water and groundwater samples were collected and analyzed (n=145) for precursors and terminal PFAS compounds between March and September 2022. Samples were collected at identified seeps along the Quashnet River (n=59), from wells upgradient from the stream-wetland system (n= 44), from contributing flow-through kettle lakes (n=8), and at multiple locations along the Quashnet River (n=34). Samples from seeps and wells had measured PFAS concentrations ranging from non-detect to approximate 3,500 ng/L (mean= 1,650 ng/L), and a range of deuterium excess values (3.2 to 15.9 per mil) indicative of varying degrees of groundwater-lake interaction prior to emergence at the discharge zones. Groundwater-lake interaction along flowpaths that sourced the sampled seeps was farther supported by significant correlations (p < 0.01) between deuterium excess and %PFAS precursors, and between %PFAS precursors and multiple terminal PFAS compounds (e.g., PFPeS, PFBS, PFHxS). However, some sampled seeps contributing groundwater to the stream-wetland system had much higher total PFAS concentrations (>1000 ng/L) than the upgradient kettle lakes, despite showing lake (evaporative) isotopic signatures, indicating the potential for groundwater flowpath convergence at wetland discharge zones and the influence of lakebed PFAS precursor reactions. PFAS compounds and water isotopic composition at sampled multilevel groundwater wells, rivers, lakes, and seeps suggest that a complex mixture of source groundwater and flowpath characteristics are responsible for diverse observed PFAS mixtures at preferential discharge zones across the stream-wetland system. Further, total PFAS loading patterns to the Quashnet River via groundwater discharge remained remarkably similar from winter to summer to fall conditions, despite a regional dry period in late summer 2022 with the upper river channel completely drying. This work addresses gaps in the existing PFAS literature by demonstrating the importance of subsurface fate and transport on PFAS compound concentrations in controlling contaminant mass loading in preferential groundwater discharge zones and presents a transferrable field toolkit for efficient characterization of spatially preferential PFAS transport dynamics.

Contaminant transport↗

ALPHANSO: Open-source modeling of (α, n) neutron source terms

Applications ranging from nuclear safeguards to dark matter detection require accurate predictions of neutron yields and energy spectra produced by (α, n) reactions. Legacy tools like SOURCES-4C remain widely used despite significant limitations, including outdated nuclear data, missing target nuclides, and restricted accessibility. Here, we present ALPHANSO, an open-source Python package for calculating (α, n) neutron source terms. ALPHANSO incorporates modern nuclear data libraries and formats covering all naturally occurring target nuclides and provides a transparent, modular framework for updating or extending the data as new evaluations are released. Comparison with an updated version of SOURCES-4A, NeuCBOT, and experimental measurements across a range of elements and materials shows that ALPHANSO reproduces neutron yields and spectra in good agreement with experimental data and state-of-the-art (α, n) calculations. These results demonstrate that ALPHANSO is a reliable, accessible, and modern alternative to legacy (α, n) source term codes such as SOURCES-4C. Its open-source design and modular data handling make it readily extensible to future evaluated nuclear data and low-background applications.

(α, n) reactions↗