Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Design and validation of a gamma-ray scanning system for measuring irradiated nuclear fuel

We report a prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Feasibility of volumetric expansion of molten chlorides by conventional pushrod dilatometry

Abstract This study is a short communication on progress made in the adaptation of conventional push-rod dilatometry for the measurement of volumetric expansion of liquid salts up to 1300 K. A new crucible design is offered as a practical solution for measurement of liquid salts by this method. Proof-of-concept measurements of the volumetric expansion of sodium chloride (NaCl) are compared to the available data in literature. Measurement of the coefficient of thermal expansion (CTE) of solid NaCl compared favorably to the available data in literature, confirming both magnitude and trend. The average CTE of NaCl (solid) was $$\overline{\alpha }_{{{\text{NaCl}}\;{\text{Solid}}}} = 5.63 \cdot 10^{ - 5} {\raise0.7ex\hbox{$1$} \!\mathord{\left/ {\vphantom {1 K}}\right.\kern-\nulldelimiterspace} \!\lower0.7ex\hbox{$K$}}$$ α ¯ NaCl Solid = 5.63 · 10 - 5 1 K . The volumetric expansion of liquid NaCl was measured as $$\beta_{{{\text{NaCl}}\;{\text{Liquid}}}} \approx 3.96 \cdot 10^{ - 5} 1/K$$ β NaCl Liquid ≈ 3.96 · 10 - 5 1 / K and is essentially constant from the melt point to 1300 K. The volumetric expansion produced by this method is in reasonable agreement with the available published data and previous measurements made by the authors by neutron radiographic technique.

Parker, S. S. (ORCID:000000018597440X)↗

Machine-Learning-based Algorithms for Automated Image Segmentation Techniques of Transmission X-ray Microscopy (TXM)

Four state-of-the-art Deep Learning-based Convolutional Neural Networks (DCNN) were applied to automate the semantic segmentation of a 3D Transmission x-ray Microscopy (TXM) nanotomography image data. The standard U-Net architecture as baseline along with UNet++, PSPNet, and DeepLab v3+ networks were trained to segment the microstructural features of an AA7075 micropillar. A workflow was established to evaluate and compare the DCNN prediction dataset with the manually segmented features using the Intersection of Union (IoU) scores, time of training, confusion matrix, and visual assessment. Comparing all model segmentation accuracy metrics, it was found that using pre-trained models as a backbone along with appropriate training encoder-decoder architecture of the Unet++ can robustly handle large volumes of x-ray radiographic images in a reasonable amount of time. This opens a new window for handling accurate and efficient image segmentation of in situ time-dependent 4D x-ray microscopy experimental datasets.

36 MATERIALS SCIENCE↗

Mass Spectrometry-Based Approaches for Clinical Biomarker Discovery in Traumatic Brain Injury

Purpose of Review: Precision treatments to address the multifaceted pathophysiology of traumatic brain injury (TBI) are desperately needed, which has led to the intense study of fluid-based protein biomarkers in TBI. Mass Spectrometry (MS) is increasingly being applied to biomarker discovery and quantification in neurological disease to explore the proteome, allowing for more flexibility in biomarker discovery than commonly encountered antibody-based assays. In this narrative review, we will provide specific examples of how MS technology has advanced translational research in traumatic brain injury (TBI) focusing on clinical studies, and looking ahead to promising emerging applications of MS to the field of Neurocritical Care. Recent Findings: Proteomic biomarker discovery using MS technology in human subjects has included the full range of injury severity in TBI, though critically ill patients can offer more options to biofluids given the need for invasive monitoring. Blood, urine, cerebrospinal fluid, brain specimens, and cerebral extracellular fluid have all been sources for analysis. Emerging evidence suggests there are distinct proteomic profiles in radiographic TBI subtypes, and that biomarkers may be used to distinguish patients sustaining TBI from healthy controls. Metabolomics may offer a window into the perturbations of ongoing cerebral insults in critically ill patients after severe TBI. Summary: Emerging MS technologies may offer biomarker discovery and validation opportunities not afforded by conventional means due to its ability to handle the complexities associated with the proteome. In conclusion, while MS techniques are relatively early in development in the neurosciences space, the potential applications to TBI and neurocritical care are likely to accelerate in the coming decade.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗

An Analysis of Input Parameters for Film-Based Flash X-Ray Radiography

Flash X-ray radiography (flash) is a commonly used diagnostic technique in dynamic experiments. An analysis of the effects of input parameters on resulting metrics of image quality can aid the experimentalist in configuring the X-ray input parameters to produce the highest quality radiograph for a given experiment. Here, a flash X-ray test bed with HS800 film and a LANEX Medium F intensifier screen was used with an L3 450 kVp pulser and Scandiflash X-ray tube for this study. Input parameters including charge voltage, source filtering, and film-pack assembly were investigated for their impact on contrast-to-noise ratio (CNR), contrast, and contrast transfer function (CTF). Using VIDAR’s NDT Pro industrial film digitizer, scanner parameters such as optical density range, pixel spacing, scan mode, and digital bit-depth were also examined for their impact on image quality metrics. The highest CNR values were found with two LANEX intensifiers and no filtering. Charge voltage had no direct impact on CNR values. LANEX screen count and filtering resulted both in direct effects on CNR and interaction effects with each other and CNR value. Uncertainty bounds for CNR comparisons and repeatability of CTF evaluations are also discussed. Finally, the film results are compared with a previous study using other detector types, specifically Carestream INDUSTREX Flex GP, Flex HR, Flex XL Blue, and HPX-DR 3543.

dynamic radiography↗

Further Development of the Tamped Richtmyer-Meshkov Instability Method and Application to Molybdenum Dynamic Strength Calibration and Tabulation

The high pressure and high strain rate dynamic strength of Mo is experimentally and computationally investigated in the 3–20 GPa stress, 50–600 C temperature, and 10 5 –10 6 /s strain rate regimes using a modified tamped Richtmyer-Meshkov instability (RMI) method. Modifications to the tamped RMI method include a method to determine loading states during strain, a new strength calibration function based on interface shape, and a robust uncertainty quantification method. These modifications improve fidelity of the tamped RMI method, allowing evaluation of the compensating effects of pressure hardening, strain rate hardening, strain hardening, and thermal softening. The new calibration function based on interface shape is not limited to sinusoidal corrugations and could be applied to additional interface shapes. Plate impact experiments are performed at Argonne National Laboratory’s Advanced Photon Source’s Dynamic Compression Sector operated by Washington State University (DCS), driving a planar shock front through a corrugated Mo-D 2 O or Mo-C 8 F 18 interface, forcing the corrugation to significantly deform. The extent of interfacial deformation, RMI growth, is experimentally observed using X-ray phase contrast imaging at the DCS. RMI jet lengths and jet shapes are extracted from the experimental radiographs, then used to calibrate numerical simulations performed with the Sandia National Laboratories (SNL) hydrocode CTH. Mo yield strength, Y, as a function of shock pressure, P, strain rate, $\dot{\varepsilon }$, accumulated strain, ϵ, relative volumetric compression, RD , and temperature, T , is determined for each impact experiment and presented. The calibrated Mo yield strength values range 1.2–1.8 GPa, with strength generally decreasing as the impact stress increases. This trend is likely caused by thermal softening or strain localization. The tabular yield strength versus loading condition data presented in this paper can be used to fit complex strength models.

Voorhees, T. J. [Sandia National Lab. (SNL-CA), Li↗

Direct observation of C 3 S particle dissolution using fast nano X-ray computed tomography

Tricalcium silicate (C 3 S) occupies 50 % to 70 % of ordinary portland cement (OPC) by mass and it is an important component affecting the hydration of OPC [1], [2], [3], [4], [5], [6], [7]. Generally, the hydration of C 3 S is described by two processes: the dissolution of C 3 S particles and the precipitation of hydration products. While it is understood that the dissolution rates of C 3 S vary with time, more precise measurements are needed to understand this process. Many mechanisms have been proposed to explain the time-evolving dissolution rates of C 3 S [2]. The metastable barrier hypothesis suggests that a thin metastable layer of hydrates forms around the C 3 S particle surface and prohibits the access of grains to the aqueous solution [8], [9], [10], [11], [12]. The slow dissolution step hypothesis suggests that the increased ion concentration from the initial reaction delays the C 3 S dissolution [2], [13], [14], [15], [16], [17]. More recent publications suggest that C 3 S may react differently depending on the existence of crystallographic defects [18], [19], [20]. Etch pits are thought to open on the particle surface during the initial reaction and this contributes to the C 3 S dissolution [21], [22]. As hydrates precipitate and cover these highly reactive surfaces, hydration slows down and the induction period starts [18], [23], [24], [25], [26]. Many experiments have been conducted to test the aforementioned mechanisms. Some hydration studies utilize bulk measurements, such as isothermal calorimetry [27], [28], [29], pore solution analysis [30], quasi-elastic neutron scattering [31], and nuclear magnetic resonance spectroscopy [32], [33]. One limitation of these measurements is that they do not provide direct and detailed information on the individual C 3 S particles. Some other studies utilize imaging techniques, such as scanning electron microscopy (SEM) [34], [35], [36] and transmission electron microscopy (TEM) [37]. However, SEM/TEM cannot track the evolution of individual particles throughout hydration [34], [35], [38], [39], [40] and they do not give insights into the microstructure of materials before hydration [34], [35], [39]. This makes it challenging to draw strong conclusions from only SEM or TEM observations. Synchrotron X-ray tomography techniques have been used more broadly in recent years to study cement hydration. They are not only non-destructive but also able to image a sample in full 3D with resolutions that can reach from micron to nanoscale. Nano computed tomography (nCT) is one technique that has been applied to study cement hydration at the nanoscale [26], [41]. A typical nCT can reach a pixel size from 15 to 65 nm, providing enough detail for observing features <1 μm. However, nCT often takes >0.5 h to finish one scan. This makes the application of this technique on continuous scans for in-situ observations challenging. Fast X-ray computerized tomography (fCT) is another technique that has shown success in studying the time-evolving cement microstructures [20], [42], [43], [44], [45], [46], [47], [48], [49]. Due to the high flux of the X-ray beam from the synchrotron ring, fCT allows a scan to be captured within 1 min at a pixel size of 1 μm. This allows a paste sample to be continuously scanned during the hydration process. However, the micron-sized resolutions limit does not provide detailed insights for particles <5 μm [20], [49]. Fortunately, the combination of nCT and fCT has allowed the development of fast nano X-ray computed tomography (fnCT). fnCT can capture a 3D data set in <2 min at a pixel size of 50 nm. This makes this procedure an exciting method to evaluate hydrating pastes. fnCT collects multiple X-ray radiographs at various rotation angles and generates a 3D model of the scanned sample, which is also referred to as a 3D tomography [50], [51]. In one tomography, the X-ray absorptions of different components (e.g., C 3 S and hydrates) differ as functions of density and chemistry [52], [53]. These X-ray absorption contrasts can be used to extract detailed information about the 3D microstructure [26], [54], [55]. In this paper, fnCT is used to collect time-lapse tomographs of hydrating C 3 S paste from 18 min after mixing to 7 h of hydration. The bulk measurements of anhydrous C 3 S, as well as the microstructural changes of individual C 3 S particles, are directly observed, quantified, and discussed. The dissolution behavior of C 3 S particles at various size scales is systematically analyzed and compared. This work aims to find the relationship between the size of C 3 S particle sizes and their dissolution rates. This provides significant insights into the early-age hydration of C 3 S on length and time scales not previously possible. Because of the magnitude of the data and the substantial amount of observations, this work will solely focus on the change in the anhydrous particles. Changes in the hydration products will be reported in future work.

42 ENGINEERING↗

Real-time damage characterization for GFRCs using high-speed synchrotron X-ray phase contrast imaging

Here, we report the application of high-speed synchrotron X-ray phase contrast imaging (PCI) in real-time damage characterization for glass fiber reinforced composites (GFRCs) subjected to dynamic loading. Dynamic single-edge notched bending (DSENB) experiments on pre-notched S-2 GFRCs were performed on a modified Kolsky compression bar. During loading, the synchrotron X-ray beam penetrated through the composite specimen from the side to detect damage evolution inside the material. Entire dynamic events were recorded by a high-speed camera as image sequences.0° and 90° unidirectional and cross-ply composites were investigated. An optical imaging technique was also employed to capture similar dynamic events in comparison with the radiographic imaging. It is demonstrated that high-speed X-ray PCI had sufficient phase contrast to characterize a crack initiation at a 20-μm spatial resolution within 920 ns and track the crack geometry during propagation, thereby providing reliable data to quantify the dynamic damage resistance of GFRCs. Furthermore, being capable of recognizing microscopic damage-related features at a sub-10-μm resolution, high-speed X-ray PCI provided fundamental material failure mechanisms to reveal the essential of macroscale structural failure of composites. It can also track the damage evolution inside and between individual plies of laminated composites. However, current high-speed X-ray PCI technique only supports in-situ observation and the high timing and spatial resolutions are limited within a field of view of ~2.5 mm in square, preventing its application in the three-dimensional and larger-area damage detection for GFRC structures.

42 ENGINEERING↗

Enabling end-to-end secure federated learning in biomedical research on heterogeneous computing environments with APPFLx

Facilitating large-scale, cross-institutional collaboration in biomedical machine learning (ML) projects requires a trustworthy and resilient federated learning (FL) environment to ensure that sensitive information such as protected health information is kept confidential. Specifically designed for this purpose, this work introduces APPFLx - a low-code, easy-to-use FL framework that enables easy setup, configuration, and running of FL experiments. APPFLx removes administrative boundaries of research organizations and healthcare systems while providing secure end-to-end communication, privacy-preserving functionality, and identity management. Furthermore, it is completely agnostic to the underlying computational infrastructure of participating clients, allowing an instantaneous deployment of this framework into existing computing infrastructures. Experimentally, the utility of APPFLx is demonstrated in two case studies: (1) predicting participant age from electrocardiogram (ECG) waveforms, and (2) detecting COVID-19 disease from chest radiographs. Here, ML models were securely trained across heterogeneous computing resources, including a combination of on-premise high-performance computing and cloud computing facilities. By securely unlocking data from multiple sources for training without directly sharing it, these FL models enhance generalizability and performance compared to centralized training models while ensuring data remains protected. In conclusion, APPFLx demonstrated itself as an easy-to-use framework for accelerating biomedical studies across organizations and healthcare systems on large datasets while maintaining the protection of private medical data.

Biomedical Research↗

Progress toward NIF opacity measurements

The opacities of iron and other mid-Z elements help to regulate the transport of energy in the sun. Recent experiments on the Sandia National Laboratories Z machine have shown large discrepancies between the measured and calculated opacities of iron at certain solar conditions. To replicate these opacity measurements a platform is being developed on the National Ignition Facility to measure the opacities of iron and other elements at the same conditions as in the Z experiments. The NIF platform consists of a hohlraum to heat the opacity sample to the desired conditions, a separate backlighter to radiograph the sample, and a spectrometer to give the spectrally resolved opacity. Not only must the opacity be measured but the temperature and density of the sample must also be accurately determined. This platform has now produced its first iron transmission measurements. Overall, these measurements will be presented along with plans for future measurements and details on how the measurements will be improved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Throughput Uniformity and Defect Monitoring in Low-Temperature Electrolysis Porous Transport Layers Using X-Ray Radiography

Effective quality control (QC) for manufacturing proton exchange membrane water electrolysis (PEMWE) components is critical to enabling widespread adoption of the technology for hydrogen generation. This study investigates X-ray radiography as a novel, high-throughput, potentially in-line QC technique for detecting defects and assessing material property distributions in titanium-based porous transport layers (PTLs) which constitute a crucial component of low temperature PEMWE stacks. We obtain radiographs of a set of fifteen PTLs and model their absorbance of the broadband radiation as a second-order polynomial to account for the non-monoenergetic radiation source used in this study. The resulting model serves as a basis for predicting the areal density and porosity distributions of the PTLs. We find radiography successful in detecting multiple instances of defects, including holes/depressions, cracks, and excess material on the surface or in the pores of the material, demonstrating its potential as a robust in-line QC tool for PTL manufacturing.

08 HYDROGEN↗

Brain-Specific Relative Biological Effectiveness of Protons Based on Long-term Outcome of Patients With Nasopharyngeal Carcinoma

Uncertainties in relative biological effectiveness (RBE) constitute a major pitfall of the use of protons in clinics. An RBE value of 1.1, which is based on cell culture and animal models, is currently used in clinical proton planning. The purpose of this study was to determine RBE for temporal lobe radiographic changes using long-term follow-up data from patients with nasopharyngeal carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High strain-rate strength response of single crystal tantalum through in-situ hole closure imaging experiments

The properties of crystalline materials often depend on directionality and operating conditions. Specifically, the strength of materials can depend anisotropically on crystal direction and the loading condition. To probe these effects, a preliminary series of high strain-rate (> 105/s) strength plate-impact hole closure experiments were performed on high purity single crystal Tantalum cubes. The orientation of the single crystals with respect to impact/loading were varied to provide data to inform crystal plasticity modeling efforts. The experiments consist of in-situ high-resolution X-ray radiographic imaging of the hole collapse under dynamic compression conditions to infer the material strength via its resistance to closure at increasing levels of plastic strain. The experiments are compared against hydrocode simulation predictions. Here, a comparison with simple elastic perfectly plastic strength model predictions is presented to elucidate the response of the different crystal orientations at high strain-rate and large plastic strains.

36 MATERIALS SCIENCE↗

Configuration and impurity quantification of AmLi sources using radiography and gamma spectroscopy

This paper presents the non-destructive assay of two AmLi sources used for detector characterization and active interrogation at PNNL, identified as MRC-101 and MRC-103. First, a detailed description of the internal configuration of 2724-BT encapsulated MRC sources is established. X-ray radiographs of the AmLi sources are reported for the first time to verify the dimensions and orientation of the encapsulation. Notably, a density variation was observed as a contrast change across the height of the source cavities. Contrary to commonly made assumptions in literature, it is indirectly observed that the AmLi source/target material only occupies a portion of the source cavity. The intensity of the prompt gamma-rays resulting from the inelastic scatter of alpha particles on 7Li was used to calculate the mass ratios of LiH:AmO2. The gamma-ray spectra revealed the presence of numerous impurities in both source and target material (243Am, 237Np, 154Eu, 23Na, and 9Be). Neutron-gamma production ratios were applied to the intensity of the Doppler-broadened peaks from alpha-induced reactions with 7Li, 9Be, and 23Na to calculate neutron rates for both sources. A neutron/alpha production yield (derived in this work) was then related to the atomic concentration of these isotopes to find the approximate masses within each source. Ultimately, the AmLi source density was estimated with prompt gamma analysis based on partial source volumes as 0.45±0.08 g/cm^3.

DTRA, AmLi, neutron↗

Quantifying spatial resolution in a fast neutron radiography system

Neutron imaging is a powerful nondestructive examination modality that has been employed in various applications. Fast neutrons provide advantages over lower energy neutrons, such as examining thicker samples and inducing negligible activation and transmutations. However, fast neutrons interact mostly via elastic scattering with both the neutron detector and the object, causing degradation in spatial resolution. This study explores the quantification of spatial resolution caused by the testing target itself and suggests proper candidate materials for characterizing spatial resolution in terms of modulation transfer function. Knife-edge radiographs of 3 mm, 6 mm, and 5 cm thick Tantalum (Ta) foils, and a 2.54 cm Tungsten (W) cube were acquired using a CCD-based imaging system and a Polyvinyl Toluene (PVT) scintillator at the Ohio State Research Reactor (OSURR)’s fast neutron beam facility. The spatial resolutions calculated were 195 ± 20 μm, 224 ± 22 μm, 248 ± 25 μm, and 435 ± 44 μm for 3 mm, 6 mm, and 5 cm Ta foils, and 2.54 cm W cube, respectively. The results showed a worsening spatial resolution with increasing target thickness. Simulations and calculations estimate that elastic scattering kinematics between neutrons and protons in the PVT medium also limits spatial resolution, and it sets a lower limit of ~44 μm on the spatial resolution for 2 MeV neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerated radiation transport modeling techniques for pencil beam computed tomography using gamma rays

Monte Carlo radiation transport modeling studies were performed for a compact, and high-resolution gamma-ray computed tomography system designed for imaging irradiated nuclear fuel. The system comprises a 60 Co source – chosen for its highly penetrating 1173 keV and 1332 keV gamma rays – a pair of high-aspect-ratio pencil beam collimators, and an inorganic scintillator detector. Here two acceleration methods are proposed to rapidly model a transmission type gamma-ray tomography system. The first, a variance reduction technique, is based on performing Monte Carlo simulations with a monodirectionally-biased source, sampled from a characteristic sub-volume of the full source volume. The second acceleration method is based on the deterministic calculations using the Beer–Lambert law and detector response characteristics. Comparison of simulations using acceleration approaches with analog simulations of the fully isotropic, full-volume equivalent, show that the Monte Carlo variance reduction technique gives quantitatively accurate predictions for large collimator aspect ratios while the deterministic calculations are semi-quantitative but converge close to the correct result as the collimator aspect ratio increases. As such, these techniques can be used to reduce the computational cost in generating simulated radiographs and tomographs by several orders of magnitude. Experimental validation efforts are currently underway and will be demonstrated in future work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗