Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

FINAL TECHNICAL AND ECONOMIC FEASIBILITY STUDY ON THE APPLICATION OF A HEAT INTEGRATED POST-COMBUSTION CO2 CAPTURE SYSTEM WITH HITACHI ADVANCED SOLVENT INTO EXISTING COAL-FIRED POWER PLANT

This report contains the results of a techno-economic assessment (TEA) conducted of a heat integrated post-combustion CO2 capture process with Hitachi advanced solvent for retrofit into an existing coal-fired power plant (but treated as greenfield plant on cost analysis). The process has been developed by the University of Kentucky Center for Applied Energy (UK CAER). EPRI was chiefly responsible for this analysis, with significant input from WorleyParsons, Hitachi Power Systems America (Hitachi) and UK CAER. The project also involves the design, fabrication, installation, testing, and analyses of a slipstream facility located at L&GE-KU’s E.W. Brown Generating Station to demonstrate the UK CAER carbon capture system that could utilize heat integration with the main power plant. The design, start-up, and baseline of the pilot system was performed with a generic 30 wt% MEA solvent to obtain data for direct comparison with the DOE/NETL Reference Case followed by testing Hitachi’s proprietary solvent H3-1. In this techno-economic analysis, two cases utilizing the UK CAER process are compared, using different approach temperatures and solvent, against the DOE/NETL Reference Case (Case 10). The results are shown comparing the energy demand for post-combustion CO2 capture and the net higher heating value (HHV) efficiency of the power plant integrated with the post-combustion capture (PCC) plant. A levelized cost of electricity (LCOE) assessment was performed showing the costs of the options presented in the study. The key factors contributing to the reduction of LCOE were identified as CO2 partial pressure increase at the flue gas inlet, thermal integration of the process, and performance of the Hitachi H3-1 solvent. Recent UK CAER process pilot-scale testing data and process simualtion data showed that the packing heights of absorber and stripper columns were significantly oversized in the prelimanary TEA (Task 2 of this project) and thus updated in this final TEA for the H3-1 case only. In addition, the solvent make-up cost for H3-1 was updated based on lattest test results. Finally, a heat integration with the main power plant was applied in this final TEA to increase overall energy effciency for both the MEA and H3-1 cases. Additonal reductions in capital and operational costs are expected but not taken into account here. Shorter columns result in reduced pressure drops, smaller blower head and pump hydraulic head requirements. An increase in overall energy efficiency resuls in a decreased size of the power plant, the CCS and a reduced parasitic steam requirement to the CCS. The net efficiency of the UK CAER integrated PC power plant with CO2 capture changes from 26.2% for the Reference Case 10 plant in 2010 revised DOE/NETL baseline report to 27.6% for the MEA options considered, and 29.1% for the options utilizing the Hitachi advanced solvent. The UK CAER Process + Hitachi case also produces an extra 30.9 MW of generation compared to the UK CAER Process + MEA case and total 60.9 MW more than DOE Case 10. LCOE ($/MWh) values are $172.08/MWh for the MEA option and $157.65/MWh for the Hitachi H3-1 solvent cases considered in comparison to $189.59/MWh in January 2012 dollar for the Reference Case 10. The UK CAER CCS process with MEA case lowers energy consumption for CO2 capture to 1340 Btu/lb-CO2 captured as compared to 1540 Btu/lb-CO2 in the Reference Case 10. The UK CAER CCS process with H3-1 case further lowers energy consumption for CO2 capture to 973 Btu/lb-CO2 captured, for an advantage of 36.8% less energy consumption than Case 10. The study also shows 38.1% less heat rejection associated with the carbon capture system from 3398 MBtu/hr (Case 10) to 2104 MBtu/hr for the UK CAER + MEA system. Heat rejection is reduced to 2464 MBtu/hr in the UK CAER + H3-1 case, for a 27.5 % decrease compared to Case 10. Modeling outputs show that in the UK CAER process, the cooling water that is 2-5°C cooler than conventional cooling tower water can be achieved for ambient conditions common to the midwest and other regions. The results from the techno-economic assessment show that the proposed technology can be investigated further as a viable alternative to conventional CO2 capture technology. The evaluation also shows the effect of the critical parameters on the LCOE, with the main variables being the approach temperature and CO2 partial pressure increase at the flue gas inlet. A summary of the key advantages of the UK CAER Process + H3-1 case for LCOE and other economic factors compared to the DOE Case 10 is as follows: • A lower variable operating cost by $1.56/MWh ($1.08MWh less than the UK CAER Process + MEA Case), a 11.7% reduction compared to the DOE Case 10 • A lower COE by $25.32MWh ($13.94/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower LCOE by $31.94/MWh ($17.51/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower cost of CO2 captured by $18.65/tonne CO2 ($9.44/tonne CO2 lower than the UK CAER Process + MEA Case), a 30.4% reduction compared to the DOE Case 10 • A lower cost of CO2 avoided by $34.95/tonne CO2 ($18.53 tonne CO2 lower than the UK CAER Process + MEA Case), a 38.7% reduction compared to the DOE Case 10

Bhown, Abhoyjit S.↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock (TM) is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Variable-Speed Geothermal Heat Pump (GHP). This document provides the relevant new modeling information for variable-speed systems not previously covered in either the single-stage or two-stage documents. Variable-speed GHPs represent the most efficient option available for this technology: They provide the most savings, with up to 46% for the applicable portion of the housing stock, compared to 31% for less efficient single-stage GHPs. Additional results shown here detail how the savings change for sections of the housing stock with different base heating fuels and in different climate zones, and they show the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

Hybrid Fuel Cell—Supercritical CO2 Brayton Cycle for CO2 Sequestration-Ready Combined Heat and Power

The low prices and its relatively low carbon intensity of natural gas have encouraged the coal replacement with natural gas power generation. Such a replacement reduces greenhouse gases and other emissions. To address the significant energy penalty of carbon dioxide (CO2) sequestration in gas turbine systems, a novel high efficiency concept is proposed and analyzed, which integrates a flame-assisted fuel cell (FFC) with a supercritical CO2 (sCO2) Brayton cycle air separation. The air separation enables the exhaust from the system to be CO2 sequestration-ready. The FFC provides the heat required for the sCO2 cycle. Heat rejected from the sCO2 cycle provides the heat required for adsorption-desorption pumping to isolate oxygen via air separation. The maximum electrical efficiency of the FFC sCO2 turbine hybrid (FFCTH) without being CO2 sequestration-ready is 60%, with the maximum penalty being 0.68% at a fuel-rich equivalence ratio (Φ) of 2.8, where Φ is proportional to fuel-air ratio. This electrical efficiency is higher than the standard sCO2 cycle by 6.85%. The maximum power-to-heat ratio of the sequestration-ready FFCTH is 233 at a Φ = 2.8. Even after including the air separation penalty, the electrical efficiency is higher than in previous studies.

10 SYNTHETIC FUELS↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

Thermodynamic analysis of a two-stage binary-fluid ejector heat pump water heater

Ejector heat pump water heaters (EHPWHs) could significantly increase the thermal efficiency of domestic water heating and reduce greenhouse gas emissions. This study addresses two major technical barriers to using EHPWHs in domestic water heating—low heating cycle coefficient of performance (COP) and low condensation temperatures—using binary fluid pairs as a working fluid in a two-stage ejector system. A comprehensive, geometry-free model of binary-fluid ejectors was built and validated to predict the entrainment ratios of binary-fluid ejectors. A thermodynamic model of a two-stage binary-fluid ejector EHPWH was built to predict the heating cycle COP of EHPWHs. The performance of the EHPWH was theoretically evaluated using HFE7000 and Novec649 as primary fluids and R600 and R1234ze(Z) as secondary fluids. HFE7000/R600 gave the highest heating cycle COP (i.e., 1.356) in producing domestic hot water at 60.0 °C. An optimum evaporation temperature of the primary fluid was identified for the maximum effective entrainment ratio and effective pressure lift ratio of two-stage ejectors. Here, the effective entrainment ratio of the two-stage ejector dominated the heating cycle COP of the EHPWH. Primary fluids with lower latent heats of evaporation and/or secondary fluids with higher latent heats of evaporation yielded higher heating cycle COPs of EHPWHs.

42 ENGINEERING↗

Directly Fused Porphyrin‐Tetracyanopentacenequinone Conjugates: Role of the Cross‐Conjugated, Powerful Electron Acceptor in Promoting Highly Efficient Charge Separation

Tetracyanopentacenequinone, a powerful electron acceptor, is fused directly to the porphyrin π-system to create a new class of donor-acceptor conjugates. Owing to the direct fusion and electron-deficient property of tetracyanopentacenequinone, strong intramolecular charge transfer both in the ground and excited states was witnessed. As a control, porphyrin fused with pentacenequinone was also investigated. Upon complete spectral and electrochemical characterization, the excited state properties were initially probed by time-dependent DFT studies, and the occurrence of electron transfer from different excited states was established. Free-energy calculations revealed higher exothermic electron transfer (>600 mV) than the control pentacenequinone-porphyrin systems. Pump-probe studies covering broad spatial and temporal regions revealed efficient excited state charge separation. This was unlike the control pentacenequinone-porphyrin system, where slow charge separation was witnessed only in the case of the zinc derivatives but not the free-base ones, followed by the populating of the triplet excited state. The lifetimes of the charge-separated states ranged between 30–500 ps depending on the solvent and metal ion in the porphyrin cavity. Nanosecond transient absorption studies established the charge recombination path to populate the triplet state of porphyrin or directly to the ground state as a function of solvent polarity and the nature of the conjugate. Furthermore, the significance of cross-conjugated tetracyanopentacenequinone fused directly to the porphyrin π system in promoting highly exothermic and efficient charge separation, irrespective of its cross conjugation, is borne out from this study.

Cross conjugation↗

Quantifying the Impact of Lagged Hydrological Responses on the Effectiveness of Groundwater Conservation

Many irrigated agricultural areas seek to prolong the lifetime of their groundwater resources by reducing pumping. However, it is unclear how lagged responses, such as reduced groundwater recharge caused by more efficient irrigation, may impact the long-term effectiveness of conservation initiatives. Here, we use a variably saturated, simplified surrogate groundwater model to: 1) analyze aquifer responses to pumping reductions, 2) quantify time lags between reductions and groundwater level responses, and 3) identify the physical controls on lagged responses. We explore a range of plausible model parameters for an area of the High Plains Aquifer (USA) where stakeholder-driven conservation has slowed groundwater depletion. We identify two types of lagged responses that reduce the long-term effectiveness of groundwater conservation, recharge-dominated and lateral-flow-dominated, with vertical hydraulic conductivity (K Z ) the major controlling variable. When high K z allows percolation to reach the aquifer, more efficient irrigation reduces groundwater recharge. By contrast, when low K z impedes vertical flow, short term changes in recharge are negligible, but pumping reductions alter the lateral flow between the groundwater conservation area and the surrounding regions (lateral-flow-dominated response). For the modeled area, we found that a pumping reduction of 30% resulted in median usable lifetime extensions of 20 or 25 years, depending on the dominant lagged response mechanism (recharge- vs. lateral-flow-dominated). These estimates are far shorter than estimates that do not account for lagged responses. To conclude, results indicate that conservation-based pumping reductions can extend aquifer lifetimes, but lagged responses can create a sizable difference between the initially perceived and actual long-term effectiveness.

54 ENVIRONMENTAL SCIENCES↗

Design of an Axial Flux Machine With an Integrated Hydraulic Pump for Off-Highway Vehicle Electrification

Axial flux machines offer an inherent torque density advantage over conventional radial flux machines and are increasingly being considered for transportation electrification applications. Electrification of off-highway vehicles is notoriously challenging due to extreme power density requirements. This paper investigates the use of axial flux machines for off-highway vehicle electrification. To maximize the power density, a hydraulic pump is integrated with the axial flux machine, resulting in a single modular, electric/hydraulic machine. This paper first compares three popular axial flux machine variants using an FEA-based design optimization approach. The single rotor, single stator variant is identified to be the most promising for integration with the hydraulic pump. Next, a multi-physics framework of the complete integrated hydraulic pump and axial flux machine is developed to search the design space. The results indicate promising potential for this concept to realize efficiency over 85% and power density over 5kW/kg for the complete machine (electric machine, hydraulic pump, and thermal management system), while utilizing conventional materials (thin gauge silicon steel, N45 magnets, and magnet wire)

Off-highway vehicles, Axial flux machines, Multi-p↗

Development of an Integrated Electro-Hydraulic Machine to Electrify Off-highway Vehicles

Electrification of off-highway vehicles is notoriously challenging due to extreme power density requirements. This paper proposes and develops an axial flux machine integrated with a hydraulic pump to realize a single modular, electro-hydraulic machine to electrify off-highway vehicle implements. This integrated machine eliminates redundant bearings, couplings, and shaft seals, re-uses surfaces, and enables direct cooling of the electric machine with the hydraulic fluid, to significantly increase power density. Three popular axial flux machine variants are first compared using an FEA-based design optimization approach. The single rotor, single stator variant is identified to be the most promising for integration with the hydraulic pump. Next, a multi-physics framework of the complete integrated hydraulic pump and axial flux machine is developed to characterize the design space. The results indicate promising potential for this concept to realize efficiency over 85% and power density over 5kW/kg for the complete machine (electric machine, hydraulic pump, and thermal management system), while utilizing conventional materials (thin gauge silicon steel, N45 magnets, and enamelled copper wire). Furthermore, a prototype axial flux machine has been experimentally characterized and integrated with a hydraulic pump to demonstrate the integrated electro-hydraulic machine concept.

33 ADVANCED PROPULSION SYSTEMS↗

Performance Considerations for Ground Source Heat Pumps in Cold Climates: Preprint

Remote, cold climates present challenges to finding safe and affordable options to heat homes. In Alaska, residential ground source heat pumps (GSHPs) have been gaining in popularity to fill this gap. However, there is little research on their long-term performance or effect on soil temperatures. The extended heating season and cold soils of Alaska provide a harsh testing ground for GSHPs, even those designed and marketed for colder climates. The large and unbalanced heating load of cold climates creates a challenging environment for GSHPs. In 2013 the Cold Climate Housing Research Center (CCHRC) installed a GSHP at its Research and Testing Facility (RTF) in Fairbanks, Alaska. The heat pump replaced an oil-fired condensing boiler heating a 464 m2 office space via an in-floor hydronic radiant heating system. The ground heat exchanger (GHE) was installed in moisture-rich silty soils underlain with permafrost near 0°C. The intent of the installation was to observe and monitor the system over a 10-year period in order to develop a better understanding of the performance of GSHPs in sites with permafrost and to help inform future design. As of this writing, the heat pump system has been running for seven heating seasons. The efficiency in those seven heating seasons has been variable with ups and downs that have been difficult to explain. This paper seeks to understand the variability in performance as well as make recommendations for GSHP use in other cold climates.

cold climate↗

Lasing in 15 atm CO 2 cell optically pumped by a Fe:ZnSe laser

10 µm lasing is studied in a compact CO 2 -He cell pressurized up to 15 atm when optically pumped by a ∼50 mJ Fe:ZnSe laser tunable around 4.3 µm. The optimal pump wavelength and partial pressure of CO 2 for generating 10 µm pulses are found to be ∼4.4 µm and 0.75 atm, respectively. Without cavity optimization, the optical-to-optical conversion efficiency reached ∼10% at a total pressure of 7 atm. The gain lifetime is measured to be ∼1 µs at pressures above 10 atm, indicating the feasibility of using high-pressure optically pumped CO 2 for the efficient amplification of picosecond 10 µm pulses.

Tovey, Dana↗

Liquid lithium divertor analysis using coupled plasma material interaction model

A liquid lithium divertor can improve performance of future fusion devices by creating efficient power exhaust and improving the energy confinement via pumping of the hydrogen isotopes. In addition, significantly higher heat fluxes can be handled if controlled vapor shielding is used to redistribute the divertor heat flux over a wider area. Design and optimization of such a system calls for an analysis model which includes a strong two-way coupling between the plasma and divertor material. The incoming plasma heat and particle flux will affect the divertor surface temperature, which is a defining factor of the lithium evaporative and sputtered flux going into the plasma. Results of the coupled model based on the plasma edge code SOLPS-ITER and the computational fluid dynamics (CFD) code ANSYS-CFX will be presented for different configurations. An analytical slab flow model is used as a heat transfer boundary condition for SOLPS, defining particle flux from the wall via calculation of the surface temperature. At the final step, results of the SOLPS analysis are verified using a 3D CFD magnetohydrodynamics (MHD) analysis which uses heat and particle flux from SOLPS as a boundary condition. In addition to plasma heat flux, both analytical and CFD temperature models include several plasma material interaction effects, such as lithium evaporation, condensation and sputtering based on deuterium target flux. New adatom sputtering model based on the available experimental data is presented. Analytical model is expanded to include free surface axisymmetric configurations. Results of parametric studies of the divertor configurations with different lithium inlet temperature and velocity will be presented leading to the optimal design resulting in the lowest possible lithium contamination in the core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unifying Advective and Diffusive Descriptions of Bedform Pumping in the Benthic Biolayer of Streams

Abstract Many water quality and ecosystem functions performed by streams occur in the benthic biolayer, the biologically active upper (~5 cm) layer of the streambed. Solute transport through the benthic biolayer is facilitated by bedform pumping, a physical process in which dynamic and static pressure variations over the surface of stationary bedforms (e.g., ripples and dunes) drive flow across the sediment‐water interface. In this paper we derive two predictive modeling frameworks, one advective and the other diffusive, for solute transport through the benthic biolayer by bedform pumping. Both frameworks closely reproduce patterns and rates of bedform pumping previously measured in the laboratory, provided that the diffusion model's dispersion coefficient declines exponentially with depth. They are also functionally equivalent, such that parameter sets inferred from the 2D advective model can be applied to the 1D diffusive model, and vice versa. The functional equivalence and complementary strengths of these two models expand the range of questions that can be answered, for example, by adopting the 2D advective model to study the effects of geomorphic processes (such as bedform adjustments to land use change) on flow‐dependent processes and the 1D diffusive model to study problems where multiple transport mechanisms combine (such as bedform pumping and turbulent diffusion). By unifying 2D advective and 1D diffusive descriptions of bedform pumping, our analytical results provide a straightforward and computationally efficient approach for predicting, and better understanding, solute transport in the benthic biolayer of streams and coastal sediments.

Grant, Stanley B.↗

Modeling with uncertainty quantification reveals the essentials of a non-canonical algal carbon-concentrating mechanism

The thermoacidophilic red alga Cyanidioschyzon merolae survives its challenging environment likely in part by operating a carbon-concentrating mechanism (CCM). Here, we demonstrated that C. merolae 's cellular affinity for CO 2 is stronger than the affinity of its rubisco for CO 2 . This finding provided additional evidence that C. merolae operates a CCM while lacking the structures and functions characteristic of CCMs in other organisms. To test how such a CCM could function, we created a mathematical compartmental model of a simple CCM, distinct from those we have seen previously described in detail. The results of our modeling supported the feasibility of this proposed minimal and non-canonical CCM in C. merolae . To facilitate the robust modeling of this process, we measured and incorporated physiological and enzymatic parameters into the model. Additionally, we trained a surrogate machine-learning model to emulate the mechanistic model and characterized the effects of model parameters on key outputs. This parameter exploration enabled us to identify model features that influenced whether the model met the experimentally derived criteria for functional carbon concentration and efficient energy usage. Such parameters included cytosolic pH, bicarbonate pumping cost and kinetics, cell radius, carboxylation velocity, number of thylakoid membranes, and CO 2 membrane permeability. Our exploration thus suggested that a non-canonical CCM could exist in C. merolae and illuminated the essential features generally necessary for CCMs to function.

Steensma, Anne K. [Michigan State Univ., East Lans↗

Needs and Opportunities for Testing of Hydropower Technology Innovations

Despite hydropower’s status as a well-established technology, changes in the global energy sector have prompted a variety of necessary hydropower technological innovations. Examples include efficient lowhead turbines, more flexible and dispatchable hydropower and pumped storage systems to complement variable and intermittent renewable resources, and technologies providing higher environmental performance. However, while innovative technologies are currently being proposed to meet these development challenges, small hydropower facility owners do not have sufficient risk-bearing capacity to adopt new, unvalidated technologies. This discourages manufacturers from bringing nascent technologies to market and stalls the technological growth of the sector. To reduce the risks associated with new technologies and promote further innovation, systemic (and sometimes unconventional) validation activities and new testing capabilities for hydropower are highly desired. These testing capabilities must demonstrate the safety, environmental acceptability, reliability, and performance of innovative technologies to quantify their value compared with existing technologies. Establishing these capabilities through dedicated testing facilities will be key to promoting hydropower growth in the United States. Following direction from the House Energy and Water Development Committee, the US Department of Energy’s Water Power Technologies Office (WPTO) has been tasked with understanding the state of hydropower testing in the United States. This scoping report discusses the needs and opportunities of hydropower testing in the United States, with a specific focus on small hydropower. Future developments will likely mostly target low-head sites with less than 30 ft (9.1 m) from new stream-reach developments, non-powered dam retrofits, and rehabilitation/upgrade of existing plants.

13 HYDRO ENERGY↗

Simultaneous Reduction of NOx and Fuel Consumption for Off-Road Powertrains

Simultaneously reducing criteria pollutants and fuel consumption is important for clean air and improving vehicle total cost of ownership. The goal of this effort was focused on a 90% NOx reduction and 10% fuel savings for an off-road 407 kW diesel engine. The baseline was a production Fiat Powertrain 13L engine and aftertreatment system meeting 0.4 g/kW-hr NOx. The baseline system was quantified over the NRTC, RMC, new low load cycle and five field cycles. A next generation engine was built incorporating several fuel-efficient design features, including a higher compression ratio, increased fuel-rail pressure, low-friction piston rings, and a high-efficiency variable-geometry turbocharger. Cylinder deactivation and EGR pump technologies were added to this engine as well. The combination was optimized prior to adding advanced aftertreatment systems, showing the trade-off of engine out NOx and exhaust temperature. Two next-generation catalyst technologies were employed into a LO-SCR plus main SCR system, both with and without an electric heater upstream of the LO-SCR. These catalysts were hydrothermally aged to simulate significant field use. Dual SCR dosing with newly developed controls played a critical role in achieving the proper split between the upstream LO-SCR and the downstream main SCR. Adding a next generation mixer for the downstream SCR proved essential in obtaining the final results. The optimal configuration required adding an electric heater to elevate the exhaust temperature at the LO-SCR for early cycle NOx reduction. The final results showed a 94.8% NOx reduction and 15.7% fuel savings on the composite NRTC.

McCarthy, James [Eaton Corporation]↗

SEASONAL PERFORMANCE SIMULATION OF A GAS-FIRED CHEMISORPTION HEAT PUMP FOR RESIDENTIAL HEATING IN COLD CLIMATE

The gas-fired chemisorption heat pump (CSHP) is a promising technology for high-efficiency cold-climate residential heating. The CSHP utilizes the heat of reversible chemical reactions between sorbent and refrigerant to extract heat from cold ambient and supply high-temperature heat to the indoors. The efficiency of CSHP depends on the ambient and heat rejection temperatures. This study evaluates the seasonal performance of a CSHP by first develop a dynamic system model to generate a performance map for various ambient and heat-supply temperatures; then the bin method is used to evaluate the CSHP seasonal performance in two cold-climate locations for space and water heating.

Yang, Zhiyao↗

Sensitivity analysis of design parameters in RowWise borehole layout for ground heat exchangers

Ground source heat pump systems offer a promising pathway toward energy-efficient building heating and cooling. The performance and cost-effectiveness of these systems heavily depend on the design of the ground heat exchanger (GHE), particularly the spatial placement of boreholes used in large commercial buildings. Among various borefield layout strategies, the RowWise approach generates and optimizes borehole configurations within irregular polygonal land boundaries, providing land-use efficiency and installation flexibility. While multiple geometric design parameters constrain the RowWise layout, their influence on the system thermal performance and total drilling requirements remains unclear. Thus, this study presents a sensitivity analysis of key design parameters influencing the RowWise layout of vertical borehole GHEs, including the perimeter spacing ratio, borehole spacing, borehole field rotation angle, and borehole length. GHEDesigner and Ray Tune are employed to generate and assess different RowWise configurations. A series of parametric simulations was conducted to quantify the impact of each parameter on geometric distribution, economic cost, and computational speed. The results provide critical insights into the sensitivity and relative importance of different design parameters of RowWise method, offering practical guidance for designers aiming to optimize GHE layouts by balancing thermal efficiency, land constraints, and economic feasibility.

Xu, Dikai [Purdue University]↗