Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

An investigation of the 'Overlap' between the Statistical-Discrete-Gust and the Power-Spectral-Density analysis methods

This paper presents the results of a NASA investigation of a claimed 'Overlap' between two gust response analysis methods: the Statistical Discrete Gust (SDG) method and the Power Spectral Density (PSD) method. The claim is that the ratio of an SDG response to the corresponding PSD response is 10.4. Analytical results presented in this paper for several different airplanes at several different flight conditions indicate that such an 'Overlap' does appear to exist. However, the claim was not met precisely: a scatter of up to about 10 percent about the 10.4 factor can be expected.

Perry, Boyd, III↗

The role of radiation hard solar cells in minimizing the costs of global satellite communications systems

An analysis embodied in a PC computer program is presented which quantitatively demonstrates how the availability of radiation hard solar cells can minimize the cost of a global satellite communication system. The chief distinction between the currently proposed systems, such as Iridium Odyssey and Ellipsat, is the number of satellites employed and their operating altitudes. Analysis of the major costs associated with implementing these systems shows that operation within the earth's radiation belts can reduce the total system cost by as much as a factor of two, so long as radiation hard components including solar cells, can be used. A detailed evaluation of several types of planar solar cells is given, including commercially available Si and GaAs/Ge cells, and InP/Si cells which are under development. The computer program calculates the end of life (EOL) power density of solar arrays taking into account the cell geometry, coverglass thickness, support frame, electrical interconnects, etc. The EOL power density can be determined for any altitude from low earth orbit (LEO) to geosynchronous (GEO) and for equatorial to polar planes of inclination. The mission duration can be varied over the entire range planned for the proposed satellite systems. An algorithm is included in the program for determining the degradation of cell efficiency for different cell technologies due to proton and electron irradiation. The program can be used to determine the optimum configuration for any cell technology for a particular orbit and for a specified mission life. Several examples of applying the program are presented, in which it is shown that the EOL power density of different technologies can vary by an order of magnitude for certain missions. Therefore, although a relatively radiation soft technology can be made to provide the required EOL power by simply increasing the size of the array, the impact on the total system budget could be unacceptable, due to increased launch and hardware costs. In aggregate these factors can account for more than a 10% increase in the total system cost. Since the estimated total costs of proposed global coverage systems range from $1 Billion to $9 Billion, the availability of radiation hard solar cells could make a decisive difference in the selection of a particular constellation architecture.

Summers, Geoffrey P.↗

Power spectral density analysis of the electromyogram from a work task performed in a full pressure suit

Surface electromyograms (EMG) taken from three upper torso muscles during a push-pull task were analyzed by a power spectral density technique to determine the utility of the spectral analysis for identifying changes in the EMG caused by muscular fatigue. The results confirmed the value of the frequency analysis for identifying fatigue producing muscular performance. Data revealed reliable differences between muscles in fatigue induced responses to various locations in the reach envelope at which the subjects were required to perform the push-pull exercise, and the differential sensitivity of individual muscles to the various reach positions; i.e., certain reach positions imposed more fatigue related shifts in EMG power than did others. It was found that a pressurized space suit changed the pattern of normal shirtsleeve muscle fatigue responses in all three of the muscles.

Lafevers, E. V.↗

Multiphysics Co-Optimization Design and Analysis of Double-Side Cooled Silicon Carbide-Based Power Module: Preprint

With the rapid growth of Electric Vehicles (EVs) and Hybrid Electric Vehicles (HEVs), much more rigorous design targets have been set for automotive power electronics, including high power density, high reliability, and low cost. Novel power module and inverter technologies based on wide bandgap (WEG) semiconductors have been developed to meet these design targets, while providing optimal power semiconductor operating temperature and promising thermomechanical performance. Compared with conventional cooling techniques which are normally applied only on one side of power module, double-side cooling approach is now believed to be the solution to enable high power density and low thermal resistance of WEG semiconductor-based power electronics. In this work, we develop a three-phase power module that is double-sided cooled using dielectric fluid jet impingement. In each phase, four silicon carbide (SiC) power semiconductors are bonded to copper busbars without electrical insulation layers. A finite element analysis (FEA) model is created for thermal and thermomechanical analysis. Based on FEA modeling results, we select particular dimensions for a parametric study to optimize thermal and mechanical performance. Using a multi-objective genetic algorithm (MOGA)-based optimization method, we have minimized the maximum junction temperature and thermal stresses within the power module. The multiphysics co-optimization approach has enabled an efficient design process of power modules with greatly reduced computational cost, as compared to conventional processes that rely on exhaustive numerical simulations and iterations.

ADVANCED PROPULSION SYSTEMS↗

Aperture efficiency of integrated-circuit horn antennas

The aperture efficiency of silicon integrated-circuit horn antennas has been improved by optimizing the length of the dipole probes and by coating the entire horn walls with gold. To make these measurements, a new thin-film power-density meter was developed for measuring power density with accuracies better than 5 percent. The measured aperture efficiency improved from 44 percent to 72 percent at 93 GHz. This is sufficient for use in many applications which now use machined waveguide horns.

Guo, Yong↗

Mathematical modeling of a thermovoltaic cell

A new type of battery named 'Vaporvolt' cell is in the early stage of its development. A mathematical model of a CuO/Cu 'Vaporvolt' cell is presented that can be used to predict the potential and the transport behavior of the cell during discharge. A sensitivity analysis of the various transport and electrokinetic parameters indicates which parameters have the most influence on the predicted energy and power density of the 'Vaporvolt' cell. This information can be used to decide which parameters should be optimized or determined more accurately through further modeling or experimental studies. The optimal thicknesses of electrodes and separator, the concentration of the electrolyte, and the current density are determined by maximizing the power density. These parameter sensitivities and optimal design parameter values will help in the development of a better CuO/Cu 'Vaporvolt' cell.

White, Ralph E.↗

A mathematical model of a CuO/Cu Vaporvolt cell

A new type of battery named 'Vaporvolt' cell is in the early stage of its development. A mathematical model of a CuO/Cu 'Vaporvolt' cell is presented that can be used to predict the potential and the transport behavior of the cell during discharge. A sensitivity analysis of the various transport and electrokinetic parameters indicates which parameters have the most influence on the predicted energy and power density of the 'Vaporvolt' cell. This information can be used to decide which parameters should be optimized or determined more accurately through further modeling or experimental studies. The optimal thicknesses of electrodes and separator, the concentration of the electrolyte, and the current density are determined by maximizing the power density. These parameter sensitivities and optimal design parameter values will help in the development of a better CuO/Cu 'Vaporvolt' cell.

Kawanami, Makoto↗

Waste-Heat-Driven Cooling Using Complex Compound Sorbents

Improved complex-compound sorption pumps are undergoing development for use as prime movers in heat-pump systems for cooling and dehumidification of habitats for humans on the Moon and for residential and commercial cooling on Earth. Among the advantages of sorption heat-pump systems are that they contain no moving parts except for check valves and they can be driven by heat from diverse sources: examples include waste heat from generation of electric power, solar heat, or heat from combustion of natural gas. The use of complex compound sorbents in cooling cycles is not new in itself: Marketing of residential refrigerators using SrCl2 was attempted in the 1920s and 30s and was abandoned because heat- and mass-transfer rates of the sorbents were too low. Addressing the issue that gave rise to the prior abandonment of complex compound sorption heat pumps, the primary accomplishment of the present development program thus far has been the characterization of many candidate sorption media, leading to large increases in achievable heat- and mass-transfer rates. In particular, two complex compounds (called "CC260-1260" and "CC260-2000") were found to be capable of functioning over the temperature range of interest for the lunar-habitat application and to offer heat- and mass-transfer rates and a temperature-lift capability adequate for that application. Regarding the temperature range: A heat pump based on either of these compounds is capable of providing a 95-K lift from a habitable temperature to a heat-rejection (radiator) temperature when driven by waste heat at an input temperature .500 K. Regarding the heat- and mass-transfer rates or, more precisely, the power densities made possible by these rates: Power densities observed in tests were 0.3 kilowatt of cooling per kilogram of sorbent and 2 kilowatts of heating per kilogram of sorbent. A prototype 1-kilowatt heat pump based on CC260-2000 has been built and demonstrated to function successfully.

Rocketfeller, Uwe↗

Preliminary Investigation of Cyclic De-Icing of an Airfoil Using an External Electric Heater

An investigation was conducted in the NACA Lewis icing research tunnel to determine the characteristics and requirements of cyclic deicing of a 65,2-216 airfoil by use of an external electric heater. The present investigation was limited to an airspeed of 175 miles per hour. Data are presented to show the effects of variations in heat-on and heat-off periods, ambient air temperature, liquid-water content, angle of attack, and. heating distribution on the requirements for cyclic deicing. The external heat flow at various icing and heating conditions is also presented. A continuously heated parting strip at the airfoil leading edge was found necessary for quick, complete, and consistent ice removal. The cyclic power requirements were found to be primarily a function of the datum temperature and heat-on time, with the other operating and meteorological variables having a second-order effect. Short heat-on periods and high power densities resulted in the most efficient ice removal, the minimum energy input, and the minimum runback ice formations. The optimum chordwise heating distribution pattern was found to consist of a uniform distribution of cycled power density in the impingement region. Downstream of the impingement region the power density decreased to the limits of heating which, for the conditions investigated, extended from 5.7 percent chord on the upper surface of the airfoil to 8.9 percent chord on the lower surface. Ice removal did not take place at a heater surface temperature of 32 F; surface temperatures of approximately 50 to 100 F were required to effect removal. Better de-icing performance and greater energy savings would be possible with a heater having a higher thermal efficiency.

Lewis, James P.↗

Design of an Axial Flux Machine With an Integrated Hydraulic Pump for Off-Highway Vehicle Electrification

Axial flux machines offer an inherent torque density advantage over conventional radial flux machines and are increasingly being considered for transportation electrification applications. Electrification of off-highway vehicles is notoriously challenging due to extreme power density requirements. This paper investigates the use of axial flux machines for off-highway vehicle electrification. To maximize the power density, a hydraulic pump is integrated with the axial flux machine, resulting in a single modular, electric/hydraulic machine. This paper first compares three popular axial flux machine variants using an FEA-based design optimization approach. The single rotor, single stator variant is identified to be the most promising for integration with the hydraulic pump. Next, a multi-physics framework of the complete integrated hydraulic pump and axial flux machine is developed to search the design space. The results indicate promising potential for this concept to realize efficiency over 85% and power density over 5kW/kg for the complete machine (electric machine, hydraulic pump, and thermal management system), while utilizing conventional materials (thin gauge silicon steel, N45 magnets, and magnet wire)

Off-highway vehicles, Axial flux machines, Multi-p↗

High Performance Flow Battery with Inexpensive Inorganic Reactants: DAYS Program (Final Technical Report)

RTRC’s DAYS projects focused on new flow battery (FB) chemistries for long duration energy storage: one that pairs aqueous polysulfide and manganese active materials in strongly alkaline electrolytes (S/Mn); another explores ligand-modified metal (LMM) chemistries in moderate pH electrolyte conditions. The S/Mn chemistry met durability targets by running for over 500 cycles and 1000 hours. Combined with this durability, power densities of up to 60 mW/cm2 at 80% round-trip efficiency, and exceptionally low-cost S and Mn active materials, the S/Mn FB offers a pathway to meeting the <5¢/kW-hr levelized cost of storage (LCOS) target first proposed by the DAYS Program and accepted by the DOE Energy Storage Grand Challenge. The LMM chemistry made impressive progress as well, including durability tests that retained performance over 600 hours of cycling. Cell optimization allowed this chemistry to operate as high as 500 mW/cm2 at 80% round-trip efficiency, nearly 10x the power density of S/Mn and comparable to the power density achieved in RTRC’s flow battery stacks using acidic vanadium battery solutions. This enabled the LMM chemistry to also offer a pathway to the <5¢/kW-hr LCOS DAYS and DOE targets. The promising results from the LMM chemistry have led to a recent DOE AMO award to advance the technology to a 5 kW, 20 kW-hr prototype.

25 ENERGY STORAGE↗

High temperature co-axial winding transformers

The analysis and design of co-axial winding transformers is presented. The design equations are derived and the different design approaches are discussed. One of the most important features of co-axial winding transformers is the fact that the leakage inductance is well controlled and can be made low. This is not the case in conventional winding transformers. In addition, the power density of co-axial winding transformers is higher than conventional ones. Hence, using co-axial winding transformers in a certain converter topology improves the power density of the converter. The design methodology used in meeting the proposed specifications of the co-axial winding transformer specifications are presented and discussed. The final transformer design was constructed in the lab. Co-axial winding transformers proved to be a good choice for high power density and high frequency applications. They have a more predictable performance compared with conventional transformers. In addition, the leakage inductance of the transformer can be controlled easily to suit a specific application. For space applications, one major concern is the extraction of heat from power apparatus to prevent excessive heating and hence damaging of these units. Because of the vacuum environment, the only way to extract heat is by using a cold plate. One advantage of co-axial winding transformers is that the surface area available to extract heat from is very large compared to conventional transformers. This stems from the unique structure of the co-axial transformer where the whole core surface area is exposed and can be utilized for cooling effectively. This is a crucial issue here since most of the losses are core losses.

Divan, Deepakraj M.↗

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗

Stable and high voltage and power output of CEA-MFCs internally connected in series (iCiS-MFC)

The voltage output of a single MFC is normally less than 0.8 V, often less than 0.3 V at maximum power output, which greatly limits the application of MFCs. When MFCs are scaled up, however, increasing reactor size has typically resulted in decreased power density. In this study, we developed a novel MFC configuration that contains multiple cloth electrode assemblies in which the MFCs were internally connected in series (iCiS-MFC). The iCiS-MFC, equivalent to 3 CEA-MFCs, produced a high voltage output over 1.8 V and a maximum power density of 3.5 W m -2 using carbon cloth cathodes containing activated carbon as the catalyst. This power density is 6% higher than that reported for a similar smaller CEA-MFC, indicating that power can be maintained during scale-up with a greater than 33-fold increase in total cathode surface area and greater than 20-fold increase in reactor volume. High stability was also demonstrated based on the performance of the iCiS-MFC over a period of one year of operation. The high power and stability is likely due, in part, to a more efficient means of current collection through the internal series connection, which also avoids the use of expensive current collectors. These results clearly demonstrate the great potential of this MFC design for further scaling-up.

25 ENERGY STORAGE↗

A novel approach for large-scale wind energy potential assessment

Increasing wind energy generation is central to grid decarbonization, yet methods to estimate wind energy potential are not standardized, leading to inconsistencies and even skewed results. This study aims to improve the fidelity of wind energy potential estimates through an approach that integrates geospatial analysis and machine learning (i.e., Gaussian process regression). We demonstrate this approach to assess the spatial distribution of wind energy capacity potential in the Contiguous United States (CONUS). We find that the capacity-based power density ranges from 1.70 MW/km2 (25th percentile) to 3.88 MW/km2 (75th percentile) for existing wind farms in the CONUS. The value is lower in agricultural areas (2.73 ± 0.02 MW/km2, mean ± 95 % confidence interval) and higher in other land cover types (3.30 ± 0.03 MW/km2). Notably, advancements in turbine manufacturing could reduce power density in areas with lower wind speeds by adopting low specific-power turbines, but improve power density in areas with higher wind speeds (>8.35 m/s at 120m above the ground), highlighting opportunities for repowering existing wind farms. Wind energy potential is shaped by wind resource quality and is regionally characterized by land cover and physical conditions, revealing significant capacity potential in the Great Plains and Upper Texas. The results indicate that areas previously identified as hot spots using existing approaches (e.g., the west of the Rocky Mountains) may have a limited capacity potential due to low wind resource quality. Improvements in methodology and capacity potential estimates in this study could serve as a new basis for future energy systems analysis and planning.

Dai, Tao↗

Pressure–strain interaction. I. On compression, deformation, and implications for Pi-D

The pressure–strain interaction describes the rate per unit volume that energy is converted between bulk flow and thermal energy in neutral fluids or plasmas. The term has been written as a sum of the pressure dilatation and the collisionless analog of viscous heating referred to as Pi–D , which isolates the power density due to compressible and incompressible effects, respectively. It has been shown that Pi–D can be negative, which makes its identification as collisionless viscous heating troubling. We argue that an alternate decomposition of pressure–strain interaction can be useful for interpreting the underlying physics. Since Pi–D contains both normal deformation and shear deformation, we propose grouping the normal deformation with the pressure dilatation to describe the power density due to converging/diverging flows, with the balance describing the power density purely due to shear deformation. We then develop a kinetic theory interpretation of compression, normal deformation, and shear deformation. We use the results to determine the physical mechanisms that can make Pi–D negative. We argue that both decompositions can be useful for the study of energy conversion in weakly collisional or collisionless fluids and plasmas, and implications are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimize out-of-core thermionic energy conversion for nuclear electric propulsion

Thermionic energy conversion (TEC) potentialities for nuclear electric propulsion (NEP) are examined. Considering current designs, their limitations, and risks raises critical questions about the use of TEC for NEP. Apparently a reactor cooled by hotter-than-1675 K heat pipes has good potentialities. TEC with higher temperatures and greater power densities than the currently proposed 1650 K, 5-to-6 W/sq cm version offers substantial gains. Other approaches to high-temperature electric isolation appear also promising. A high-power-density, high-temperature TEC for NEP appears, therefore, attainable. It is recommended to optimize out-of-core thermionic energy conversion for nuclear electric propulsion. Although current TEC designs for NEP seem unnecessary compared with Brayton versions, large gains are apparently possible with increased temperatures and greater power densities.

Morris, J. F.↗

Coupled neutronics, thermochemistry, corrosion modeling and sensitivity analyses for isotopic evolution in molten salt reactors

This study presents a computational methodology for analyzing isotopic evolution and associated uncertainties in molten salt reactors (MSRs), focusing on both fluoride- and chloride-based fuel salts. The primary goal is to enhance the understanding of isotopic behavior in MSRs and provide data to support future experimental efforts. The methodology integrates transport-coupled depletion calculations using OpenMC, equilibrium thermodynamics modeling with Thermochimica, and a corrosion model. Sensitivity analyses are performed to evaluate the impact of power density, air ingress, and humidity content on isotopic evolution in MSR concepts. This study examines representative F- and Cl-based MSR designs, highlighting the dominant influence of power density on isotopic composition, which significantly affects isotope production and depletion rates, accounting for approximately 76% of the observed variance in element concentration. Air ingress and humidity content also affect the redox potential, solubility of heavier elements, and corrosion rates, thereby altering the expected isotopic evolution in the reactor. On average, air ingress accounts for around 17% of the variance in element concentrations, while humidity explains the remaining 7%. These variances differ significantly from element to element, depending on the element’s role in depletion, redox potential evolution, and galvanic corrosion. The findings indicate that power density, air ingress, and humidity content are all critical factors for optimizing reactor design and operational strategies. Furthermore, the study provides expected ranges for key impurities in the fuel salt, which are crucial for guiding future experimental studies and refining MSR designs. Finally, this study demonstrates the importance of modeling depletion coupled with the evolution of redox potential and chemical interactions in MSR fuel salts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗