Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “physics education”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Resolve instrument onboard XRISM: design, integration, and instrument test results

The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6 × 6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼ 5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm 2 at 1 keV and 424 cm 2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.

X-ray↗

Transforming Uinta Basin Earth Materials for Advanced Products (TUBE-MAP)

The objectives of this project were to quantify, assess, and plan to enable the transformation of Uinta Basin earth resources, such as coal, oil shale, resin, rare earth elements, and critical minerals into high value metal, mineral, and carbon-based products. The specific major goals were 1) basinal assessments and initial planning (Task 2), 2) basinal assessment for waste stream reuse with associated plan development (Task 3), 3) basinal strategies development for infrastructure, industries, and business (Task 4), 4) technology assessment, development, and field-testing plan (Task 5), 5) technology innovation center plan (Task 6), and 6) stakeholder outreach and education plan (Task 7).

01 COAL, LIGNITE, AND PEAT↗

Fusion Energy Sciences Network Requirements Review. Final Report, April - October 2021

The Energy Sciences Network (ESnet) is the high-performance network user facility for the US Department of Energy (DOE) Office of Science (SC) and delivers highly reliable data transport capabilities optimized for the requirements of data-intensive science. In essence, ESnet is the circulatory system that enables the DOE science mission by connecting all of its laboratories and facilities in the US and abroad. ESnet is funded and stewarded by the Advanced Scientific Computing Research (ASCR) program and managed and operated by the Scientific Networking Division at Lawrence Berkeley National Laboratory (LBNL). ESnet is widely regarded as a global leader in the research and education networking community. Throughout 2021, ESnet and the Office of Fusion Energy Sciences (FES) of the DOE SC organized an ESnet requirements review of FES-supported activities. Preparation for these events included identification of key stakeholders: program and facility management, research groups, and technology providers. Each stakeholder group was asked to prepare formal case study documents about their relationship to the FES program to build a complete understanding of the current, near-term, and long-term status, expectations, and processes that will support the science going forward.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Collaboration Website for Muon Catalyzed Fusion and Muon Beam Production

This research initiative establishes a dynamic online platform geared towards supporting the burgeoning Muon Catalyzed Fusion collaboration, focusing on the concurrent development of particle accelerators and transport beamlines for muon beams. The central feature of this endeavor is the creation of a multifaceted website comprising both public facing and private sections to cater to diverse user needs. The public segment is meticulously designed to serve as an educational hub, featuring information pages targeted at the general public alongside private pages exclusively accessible to collaboration members. These pages will host an array of multimedia elements, ranging from images and text animations to video lectures, covering an extensive spectrum of topics integral to the science of Muon Catalyzed Fusion. Encompassing areas such as Acceleration, Applications, Instrumentation, Beamline Design, and beam dynamics design codes, the educational content aims to make complex scientific concepts more accessible to a broader audience. Ensuring seamless accessibility across various devices and operating systems, the website incorporates integration with collaborative tools such as Google Docs for document collaboration, GitHub for code repository management, and WordPress for blogging with interactive commenting features. The bifurcation between public and private sections is a strategic approach to maintaining transparency while safeguarding proprietary research and works in progress. The public pages are strategically crafted to disseminate information, showcasing the latest endeavors and achievements within the NK Labs collaboration, including lectures, published papers, and regular blog posts open to public comments. On the other hand, the private section provides collaboration members with a secure space to share unpublished or nonpublic research, fostering collaborative efforts through integrated Google Docs and Python Plotty for shared graphing work. In essence, this ambitious project endeavors to bridge the gap between complex scientific knowledge and public understanding, enhance collaboration among researchers, and serve as a dynamic and inclusive platform for sharing and advancing the state-of-the-art in Muon Catalyzed Fusion and Accelerators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Collaboration Website for Muon Catalyzed Fusion and Muon Beam Production

This project sets up a website to support the nascent Muon Catalyzed Fusion collaboration including development of particle accelerators and transport beamlines for muon beams. The website is envisioned as having the general public information pages and private pages for collaboration members. Multimedia elements like images, text animations, and video lectures, covering a broad spectrum of topics will populate the educational site, covering muon facilities, to comprehensive explorations and seminal documents that define the science of Muon Catalyzed Fusion, Acceleration, Applications, Instrumentation, Beamline Design, and beam dynamics design codes. Ensuring compatibility across devices and operating systems, it also features integration with Google Docs for collaboration, a code repository (GitHub), a blog platform with comments (WordPress), the potential for ChatGPT integration and interactive graph plotting with Python Plotty to enhance data visualization. This project will maintain public and protected private pages, due to the proprietary nature of the work or research in progress. The public sections will be built to foster dissemination of information and highlight recent work within the NK Labs collaboration, including lectures, published papers, and regular blog posts with open commenting. The private section will support unpublished or nonpublic research, by facilitating collaborative efforts through integrated Google Docs and Python Plotty for shared graphing work. Ultimately, this project strives to make complex scientific knowledge more accessible to the public, foster enhanced collaboration, and serve as a platform for sharing cutting-edge research in Muon Catalyzed Fusion and Accelerators.

43 PARTICLE ACCELERATORS↗

XRISM high-resolution X-ray spectroscopy of Cygnus X-1: Highly ionized iron absorption structures

We present the first high-resolution X-ray spectral analysis of Cygnus X-1 using XRISM. The observation wa3s carried out from 2024 April 7 to 10, covering the orbital phase range 0.65–0.17 during its low/hard state. Taking advantage of the exceptional energy resolution of the Resolve instrument, we examined highly ionized iron absorption lines and characterized the ionization states, column densities, and line-of-sight velocities of the absorbing plasma. Spectral analysis revealed an ionization parameter of $\xi \sim 3$, column densities of a few $\times 10^{21}$ cm$^{-2}$, and a blueshifted velocity of $\sim$100 km s$^{-1}$. The observation was divided into two phases: before and after orbital phase $\phi _{\rm {orb}} = 0.9$, corresponding to non-dipping and dipping intervals. While only weak absorption features were present before $\phi _{\rm {orb}} = 0.9$, strong absorption by He-like and H-like Fe appeared during the dipping phase. We measured equivalent widths of 2.3, 0.4, and 1.2 eV for He-like Fe K$\alpha$ and H-like Ly$\alpha _1$ and Ly$\alpha _2$, respectively—demonstrating the capability of XRISM Resolve to securely detect narrow absorption features of only a few eV. These measurements trace the motion of the absorbing material and offer insight into the kinematics and spatial distribution of the wind in the vicinity of the black hole. These findings enhance our understanding of wind-fed accretion in Cygnus X-1 and highlight the importance of continued high-resolution X-ray observations to further constrain the physical properties of winds and accretion flows in high-mass X-ray binaries.

Astronomy and AstroPhysics↗

Novel additive manufacturing for plasma facing materials ‐ creating a research pathway for minority students

This project addresses two critical and intertwined challenges in fusion energy, namely the shortage of a broadly trained scientific workforce and the lack of scalable manufacturing solutions for plasma-facing components (PFCs). Through a collaboration among Florida International University (FIU), Miami Dade College (MDC), and Purdue University, the project established structured, reproducible educational and research pathways that recruit and advance students from institutions historically outside the fusion energy enterprise, building the human capital that this field urgently needs. The project integrates the complementary research strengths of FIU and Purdue to investigate flash sintering as a transformative processing route for tungsten-based PFCs. Unlike conventional sintering approaches, flash sintering offers rapid densification at significantly reduced thermal budgets, making it a compelling candidate for fabricating complex tungsten geometries that must withstand extreme plasma-facing environments. Systematic experimental and modeling efforts will elucidate the fundamental mechanisms governing microstructure evolution, grain boundary chemistry, and thermomechanical response during flash sintering — knowledge that is presently lacking but essential for translating this technology into reliable manufacturing practice. The convergence of workforce development and cutting-edge manufacturing research positions this project to deliver measurable, durable impact: a pipeline of fusion-ready researchers cultivated through expanded institutional partnerships, and a validated materials processing framework that accelerates domestic readiness for next-generation fusion reactor construction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Revisiting the Role of Mobile Ion Size for the Activation Barrier of Charge Transport in Single Ion Conducting Polymers

The development of polymer electrolytes for energy storage and conversion technologies requires a fundamental understanding of the material parameters controlling the energy barriers for ion transport. In glassy polymers, these activation barriers are usually extracted by using Arrhenius procedures. However, our recent studies of single ion conducting polymers reveal that this traditional Arrhenius description provides anomalously small prefactors, an issue that is widely disregarded in the literature. Here, to address it, an alternative approach was introduced for extracting the effective activation barrier E by imposing a physically valid limit (∼10 –13 s) for the ion hopping attempt time. Two consequences of this recent approach are that in polymer electrolytes (i) E is significantly (∼30–40%) lower than the barrier estimated using traditional Arrhenius fits and (ii) E displays significant temperature dependence even in the glassy state. Under these circumstances, we are revisiting the role of ion size, glass transition temperature T g , and dielectric and elastic constants of the polymer matrix on the effective activation barriers for ion transport as extracted using the recently proposed approach and highlight the differences from the picture that previously emerged based on simplistic apparent Arrhenius analysis. To this end, we investigate cation transport in three families of single ion conducting trifluoromethane sulfonimide-based polyanions with varied T g . Our results indicate that E decreases with mobile cation size and is highly sensitive to changes in the dielectric permittivity of the matrix, even for large cations. These insights call for revisions of many earlier results based on apparent Arrhenius fits as the proposed approach can provide more accurate guidance for the design of polymer electrolytes with enhanced ionic conductivity.

energy barrier↗

The Linear Collider Facility (LCF) at CERN

In this paper we outline a proposal for a Linear Collider Facility as the next flagship project for CERN. It offers the opportunity for a timely, cost-effective and staged construction of a new collider that will be able to comprehensively map the Higgs boson's properties, including the Higgs field potential, thanks to a large span in centre-of-mass energies and polarised beams. A comprehensive programme to study the Higgs boson and its closest relatives with high precision requires data at centre-of-mass energies from the Z pole to at least 1 TeV. It should include measurements of the Higgs boson in both major production mechanisms, ee -> ZH and ee -> vvH, precision measurements of gauge boson interactions as well as of the W boson, Higgs boson and top-quark masses, measurement of the top-quark Yukawa coupling through ee ->ttH, measurement of the Higgs boson self-coupling through HH production, and precision measurements of the electroweak couplings of the top quark. In addition, ee collisions offer discovery potential for new particles complementary to HL-LHC.

43 PARTICLE ACCELERATORS↗

High-count rate effects in event processing for XRISM/ Resolve X-ray microcalorimeter: I. Ground test

The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. We utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high-count rate measurements and propose modeling approaches to mitigate them. We specifically address the following instrumental effects that impact performance: CPU limit, pile-up, and untriggered electrical cross-talk. Experimental data at high count rates were acquired during ground testing using the flight model instrument and a calibration X-ray source. In the experiment, data processing not limited by the performance of the onboard CPU was run in parallel, which cannot be done in orbit. This makes it possible to access the data degradation caused by limited CPU performance. We use these data to develop models that allow for a more accurate estimation of the aforementioned effects. To illustrate the application of these models in observation planning, we present a simulated observation of GX 13+1. Understanding and addressing these issues is crucial to enhancing the reliability and precision of X-ray spectroscopy in situations characterized by elevated count rates.

47 OTHER INSTRUMENTATION↗

1. Physical Security Engineering by Design for Nuclear Facilities; 2. Nuclear Power Plant Site Security Management – A Security Strategy; 3. The UAE Women in Nuclear Energy Security

1. Security by design, or SeBD, is a comprehensive approach that integrates the physical protection system of a nuclear plant into every stage of its existence. This includes planning, designing, constructing, commissioning, and operating the facility, using a combination of analytical, physical, technological, and procedural measures. Essentially, SeBD involves intentionally applying and incorporating security into all aspects of design and operation throughout the entire lifecycle of a facility. By implementing this methodology throughout various phases such as program development, process implementation, staff training and procedures management in conjunction with plant equipment, facilities can be optimized to minimize security risks without compromising functional design requirements. This ultimately improves the overall security posture of the site and reduces the need for costly modifications or additional security resources post-design. 2. A site security strategy is a living document that is revised on a periodic or event-driven basis, ensuring that site security operations and corresponding procedures provide long-term, effective protection for the entire nuclear power plant (NPP) site. A site security strategy aims to mitigate threats across the entire NPP site via in-depth defense approaches and mutual support; therefore, if a layer is omitted or altered, then the effect across all layers must be re-evaluated. Therefore, the aim of the site security strategy is to provide an appropriate, scalable security regime that deters, denies, delays, and detects incidents and, equally importantly, reassures legitimate users and the regulator that due diligence and regulatory compliance have been achieved, ensuring that the site is safe and secure. Robust access control for vehicles and pedestrians is at the heart of the strategy. Vehicle and pedestrian searching and screening are seen as the strongest mitigation methods against vehicle- and pedestrian-borne attacks. The security strategy must also be supported through comprehensive staff training and the development of robust processes, procedures, and planning. If all these measures are to be effective, then training must be implemented during each phase of construction, partial operation/commissioning, and full operation. No single element of site security is completely isolated from the influence of other elements. Ideally, consideration of all key elements will result in a security strategy that is integrated and proportional to the threat and that does not over specify individual security solutions through the application of isolated measures but rather applies a holistic, all-encompassing approach. 3. When women enter the labor force, numerous positive outcomes emerge, including increased GDP, educational gains, and decreased maternal mortality. Despite these benefits, women's employment rates and equality vary significantly worldwide as does support for women in the workforce. This paper will explore the multifaceted benefits of women's employment, the factors influencing labor force participation rates, and the urgency to achieve gender equality as outlined in the 2015 United Nations Sustainable Development Goals (SDGs). It will then examine the emerging presence of women in the traditionally male-dominated nuclear field, specifically within the United Arab Emirates (UAE) as a testament to their resilience and determination to break social norms and advance gender equality.

Zineddin, Dr. Z.↗

Pore-scale visualization of natural hydrate-bearing sediments

Accurate modeling of gas hydrate reservoir productivity and geomechanical risks associated with subsurface dissociation of natural gas hydrates (NGH) requires the determination of model parameters through physical testing on natural hydrate-bearing sediments (HBS). This involves investigating the hydro-mechanical behavior of undisturbed hydrate samples from nature under in situ conditions using pressure core characterization and analysis, which provides a unique opportunity for research. By employing state-of-the-art micro computed tomography imagery on cryogenically preserved, hydrate-bearing sediment samples, we can determine hydrate saturation as well as permeability with and without the presence of hydrates in the sediment. Furthermore, utilizing a machine learning based image segmentation technique, it is possible to extract pore space and grain information. Subsections of the entire image volume were used to determine anisotropic permeabilities using a finite-difference method Stokes solver (FDMSS). Additionally, permeability measurements on whole pressure and temperature preserved hydrate-bearing core were analyzed by utilizing the National Energy Technology Laboratory’s (NETL) Pressure Core Characterization and X-ray CT Visualization Tool (PCXT) to manipulate, cut, and analyze pressure preserved sediment. Permeabilities were measured under a broad range of vertical stress states to simulate expected pressure changes during production scenarios, and the results show that permeabilities derived from images are in agreement with those from traditional core derived experiments. The collected stress-dependent permeability, permeability anisotropy, and corresponding gas hydrate saturations provide valuable input into numerical simulations of reservoir productivity. These properties have been proven to be key parameters determining a long-term reservoir response under depressurization.

Liu, Mengwei [Oak Ridge Institute for Science and ↗

High-count-rate effects in event processing for the XRISM/Resolve X-ray microcalorimeter. II. Energy scale and resolution in orbit

The Resolve instrument on the X-ray Imaging and Spectroscopy Mission (XRISM) uses a 36 pixel microcalorimeter designed to deliver high-resolution, non-dispersive X-ray spectroscopy. Although it is optimized for extended sources with low count rates, Resolve observations of bright point sources are still able to provide unique insights into the physics of these objects, as long as high-count-rate effects are addressed in the analysis. These effects include the loss of exposure time for each pixel, changes in the energy scale, and changes in the energy resolution. To investigate these effects under realistic observational conditions, we observed the bright X-ray source, the Crab Nebula, with XRISM at several offset positions with respect to the Resolve field of view and with continuous illumination from 55 Fe sources on the filter wheel. For the spectral analysis, we excluded data where exposure-time loss was too significant to ensure reliable spectral statistics. The energy scale at 6 keV shows a slight negative shift in the high-count-rate regime. The energy resolution at 6 keV worsens as the count rate in electrically neighboring pixels increases, but can be restored by applying a nearest-neighbor coincidence cut (“cross-talk cut”). We examined how these effects influence the observation of bright point sources, using GX 13+1 as a test case, and identified an eV-scale energy offset at 6 keV between the inner (brighter) and outer (fainter) pixels. Users who seek to analyze velocity structures on the order of tens of km s–1 should account for such high-count-rate effects. These findings will aid in the interpretation of Resolve data from bright sources and provide valuable considerations for designing and planning for future microcalorimeter missions.

X-rays: general↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

Dissolved Organic Carbon in Coastal Waters: Global Patterns, Stocks and Environmental Physical Controls

Abstract Dissolved organic carbon (DOC) in coastal waters is integral to biogeochemical cycling, but global and regional drivers of DOC are still uncertain. In this study we explored spatial and temporal differences in DOC concentrations and stocks across the global coastal ocean, and how these relate to temperature and salinity. We estimated a global median coastal DOC stock of 3.15 Pg C (interquartile range (IQR) = 0.85 Pg C), with median DOC concentrations being 2.2 times higher than in open ocean surface waters. Globally and seasonally, salinity was the main driver of DOC with concentrations correlated negatively with salinity, without a clear relationship to temperature. DOC concentrations and stocks varied with region and season and this pattern is likely driven by riverine inputs of DOC and nutrients that stimulate coastal phytoplankton production. Temporally, high DOC concentrations occurred mainly in months with high freshwater input, with some exceptions such as in Eastern Boundary Current margins where peaks are related to primary production stimulated by nutrients upwelled from the adjacent ocean. No spatial trend between DOC and temperature was apparent, but many regions (19 out of 25) had aligned peaks of seasonal temperature and DOC, related to increased phytoplankton production and vertical stratification at high temperatures. Links of coastal DOC with salinity and temperature highlight the potential for anthropogenic impacts to alter coastal DOC concentration and composition, and thereby ecosystem status.

Lønborg, Christian [Section for Marine Diversity a↗

KENO-VI Primer: Performing Calculations using SCALE’s Criticality Safety Analysis Sequence (CSAS6) with Fulcrum

The SCALE code system developed at Oak Ridge National Laboratory is widely used and accepted around the world for criticality safety analysis. The well-known KENO-VI three-dimensional Monte Carlo criticality computer code is one of the primary criticality safety analysis tools in SCALE. The KENO-VI primer is designed to help a new user understand and use the SCALE/KENO-VI Monte Carlo code for nuclear criticality safety analysis. It assumes that the user has a college education in a technical field. There is no assumption of familiarity with Monte Carlo codes in general or with SCALE/KENO-VI in particular. The primer is designed to teach by example, with each example illustrating two or three features of SCALE/KENO-VI that are useful in criticality analysis. The primer is based on SCALE 6.2 and 6.3, which includes the Fulcrum graphical user interface. Each example uses Fulcrum to provide the framework for preparing input data and viewing output results. Starting with a Quickstart section, the primer gives an overview of the basic requirements for SCALE/KENO-VI input and allows the user to quickly run a simple criticality problem with SCALE/KENO-VI. Each following section begins with a list of basic objectives identifying the goal of the section and the individual SCALE/KENO-VI features covered in detail in the section’s sample problems. Upon completion of the primer, a new user should be comfortable using Fulcrum to set up criticality problems in SCALE/KENO-VI. The primer provides a starting point for the criticality safety analyst who uses SCALE/KENO-VI. Complete descriptions are provided in the SCALE/KENO-VI manual. Although the primer is self-contained, it is intended as a companion volume to the SCALE/KENO-VI training and documentation. The SCALE manual and training schedule are available at https://scale.ornl.gov. The primer provides specific examples of using SCALE/KENO-VI for criticality analysis; the SCALE/KENO-VI manual provides information on the use of SCALE/KENO-VI and all its modules. The primer also contains an appendix with sample input files. In addition, this primer, its errata, and sample inputs are also available at https://code.ornl.gov/scale/primers/kenovi/.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗