Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Performance evaluation of photovoltaic/thermal–HDH desalination system

The efficiency of photovoltaic (PV) panel drops with increase in cell temperature. The temperature of the PV panel can be controlled with various cooling techniques. In the proposed work the PV panel is cooled by circulating water and the recovered heat energy is used to run a humidification and dehumidification desalination to produce distilled water from sea water (or) brackish water. This work deals with a detailed analysis of performance of combined power and desalination (Photovoltaic/Thermal–Humidification and Dehumidification) system. A mathematical model of PV/thermal–humidification dehumidification plant was developed and simulations were carried out in MATLAB environment. The performance of photovoltaic/ thermal desalination (Photovoltaic/Thermal–Humidification and Dehumidification) system was investigated under various solar radiation levels (800–1000 W/m{sup 2}). For each solar radiation level the effect of mass flow rate of coolant water (30–110 kg/h) on water outlet temperature, PV efficiency, PVT thermal efficiency, distilled water production, and plant efficiency was studied. Results show that under each solar radiation level increasing coolant flow rate increases efficiency of PV panel and reduces the plant efficiency. The highest PV efficiency (16.598%) was reached under 800 W/m{sup 2} at mass flow rate of 110 kg/h and the highest plant efficiency (43.15%) was reached under 800 W/m{sup 2} at a mass flow rate of 30 kg/h. The maximum amount of distilled water production rate (0.82 L/h) was reached under 1000 W/m{sup 2} at water mass flow rate of 30 kg/h.

14 SOLAR ENERGY↗

Laboratory Performance Evaluation of Residential Scale Gas Engine Driven Heat Pump

Building space cooling is, and until 2040 is expected to continue to be, the single largest use of electricity in the residential sector in the United States (EIA Energy Outlook 2015 .) Increases in electric-grid peak demand leads to higher electricity prices, system inefficiencies, power quality problems, and even failures. Thermally-activated systems, such as gas engine-driven heat pump (GHP), can reduce peak demand. This study describes the performance of a residential scale GHP. It was developed as part of a cooperative research and development agreement (CRADA) that was authorized by the Department of Energy (DOE) between OAK Ridge National Laboratory (ORNL) and Southwest Gas. Results showed the GHP produced 16.5 kW (4.7 RT) of cooling capacity at 35 C (95 F) rating condition with gas coefficient of performance (COP) of 0.99. In heating, the GHP produced 20.2 kW (5.75 RT) with a gas COP of 1.33. The study also discusses other benefits and challenges facing the GHP technology such as cost, reliability, and noise.

Abu-Heiba, Ahmad↗

Performance Evaluation of Gray-box and Machine Learning Models of a Thermal Energy Storage System with Active Insulation

An interior partition wall integrated with active thermal storage and a dynamic insulation system was built and then installed in an office building in Oak Ridge, Tennessee, TN. This smart wall, termed the Empower Wall, was equipped with embedded pipes in the building envelope core component and an additional pipe network enclosing rigid insulation to switch on and off the active insulation dynamically. The performance of the wall's contribution to cooling load reduction under different parameters has been investigated in previous publications. Aiming to be deployed into model predictive control and other optimization methods, simplified and reliable models for the developed wall and the room accommodating it are required. They are needed to characterize the properties and thermal response of both Empower Wall and building envelope, which form an essential component for accurate indoor temperature or cooling/heating demand prediction. In this study, simplified gray-box and regression models as well as machine learning model were developed and the performance of them were compared and analyzed.

Cui, Borui↗

Performance evaluation of an energy tuning assembly for neutron spectral shaping

An energy tuning assembly (ETA) was designed here to be fielded at the National Ignition Facility (NIF) to modify the characteristic D-T fusion spectrum to include a prompt fission neutron spectral component. The ETA was characterized at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory to measure the shaped spectrum from an incident deuteron breakup neutron source, test the proposed neutron spectroscopy techniques used to inform the flux measurements at NIF, and validate the ability to predict ETA performance using a Monte Carlo Neutral Particle (MCNP) simulation. Activation foils (i.e., Ni, In, Au, Al) were exposed to a collimated 33-MeV deuteron-breakup beam originating from a tantalum breakup target. The source spectrum absent the ETA was characterized using a set of activation foils and the STAYSL unfolding code. Finally, the ETA-modified spectrum was obtained using activation foil unfolding with a χ 2 ν = 0 . 92 . The ETA-modified unfolded spectrum agreed with the MCNP-simulated prediction in the energy range of 0.1–14 MeV, but exhibited disagreements in the 10 eV–100 keV region. This work demonstrates shaping of the NIF neutron spectrum via the ETA to be a viable path forward for tailored neutron beams at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of the Second JLAB C75 Cryomodule & Performance Evaluation of Installed C75 Cavities

JLAB has long been a hub of SRF technology with the CEBAF accelerator as one of its first large scale adopters. As SRF technology has advanced, the C50 and C100 programs have allowed for the extension of CEBAF's total energy to 6 GeV and nearly 12 GeV respectively. Along with the increase in energy reach, rates of accelerating gradient degradation have been extracted for these cryomodule designs. A plan to mitigate these losses & maintain robust gradient headroom to deliver the 12 GeV program - the CEBAF Performance Plan - established a multi-year effort of cryomodule refurbishments and replacements. Part of this plan included a cost optimization of the C50 program with more modern processing techniques and the replacement of existing cavities with larger grain boundary cavities produced from ingot Niobium (dubbed C75 for 75 MeV gain). Reports have been made on the prototype pair of C75 cavities installed in a C50 cryomodule and the first full C75 cryomodule installed in 2017 and 2021. This paper reports on the results from the qualification of the cavities for the second C75 module in both a vertical cryostat and the commissioning results of the cryomodule in the CEBAF tunnel. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177.

McCaughan, Michael↗

Performance evaluation of a novel anaerobic digestion operation process for treating high-solids content chicken manure: Effect of reduction of the hydraulic retention time at a constant organic loading rate

Highlights: • A novel feeding strategy, keeping constant OLR but reducing HRT{sub CM} was adopted. • The effect of reducing HRT{sub CM} on CH{sub 4} fermentation of chicken manure was studied. •High content of ammonia was the main inhibition factor at HRT{sub CM} of 52 days. • Reduce in HRT{sub CM} relaxed the inhibition of high ammonia at OLR of 6.0 gVS/L/d. • The performance deterioration occurred as HRT{sub CM} decreased to 10 days. - Abstract: A novel feeding strategy was adopted in this study and the effect of reduction in hydraulic retention time (HRT) on the anaerobic digestion of chicken manure (CM) with a constant organic loading rate of 6.0 gVS/L/d was investigated. The lab-scale CSTR was operated at 38 °C and HRT{sub CM} was reduced from 52 days to 5 days. At HRT{sub CM} of 20–45 days, the reactor was relatively stable in terms of the volumetric biogas production rates and specific biogas production (SBP), which were 2.2–2.4 L/L/d and 338.3–418.7 mL/gVS{sub added}, respectively. However, process instability and VFA accumulation occurred when the HRT{sub CM} was reduced to 10 days due to excess microbes washout. The reduction in HRT{sub CM} to 5 days caused SBP to decrease to 198.7 mL/gVS{sub added} and the acetic acid content to exceed 6000 mg/L. The biomass balance model showed that the biomass concentration at HRT{sub CM} of 20–52 days (0.473–0.615 gVSS/L) was notably higher than that at HRT{sub CM} of 5–10 days (0.173 gVSS/L).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LABORATORY EVALUATION: PERFORMANCE OF A 10 RT GAS-ENGINE-DRIVEN HEAT PUMP (GHP)

Building air-conditioning (cooling) is the single largest use of electricity, driving increases in summer peak electric demand in much of the United States. Increases in peak load on the utility grid lead to high electricity prices, power quality problems, and grid system inefficiencies and even failures. Improved air-conditioning technology thus has the greatest potential impact on the electric grid compared to other technologies that use electricity. Thermally-activated systems, such as natural gas engine-driven heat pumps, can provide overall peak load reduction and electric grid relief for summer peak demand. This study describes the performance of a 10 refrigeration ton (RT) natural gas engine-driven heat pump rooftop unit in a controlled environment over a wide range of operating conditions in heating and cooling modes. Results showed gas COP exceeding the goal of 1.6 at 47 F (8.3 C) rating condition. Gas COP in cooling mode also exceeded the goal of 1.2 at 95 F (35 C) rating condition. Future work will investigate additional applications for gas engine-driven equipment, such as residential space conditioning.

03 NATURAL GAS↗

Development and Performance Evaluation of High Temperature Concrete for Thermal Energy Storage for Solar Power Generation

Thermal energy can be stored by the mechanism of sensible or latent heat or heat from chemical reactions. Sensible heat is the means of storing energy by increasing the temperature of the solid or liquid. Since the concrete as media cost per kWh thermal is $1, this seems to be a very economical material to be used as a TES. This research is focused on extending the concrete TES system for higher temperatures (500 °C to 600 °C) and increasing the heat transfer performance using novel construction techniques. To store heat at high temperature special concretes are developed and tested for its performance. The storage capacity costs of the developed concrete is in the range of $0.91-$3.02/kWh thermal . Two different storage methods are investigated. In the first one heat is transported using molten slat through a stainless steel tube and heat is transported into concrete block through diffusion. The cost of the system is higher than the targeted DOE goal of $15/kWht hermal . The increase in cost of the system is due to stainless steel tube to transfer the heat from molten salt to the concrete blocks.The other method is a one-tank thermocline system in which both the hot and cold fluid occupy the same tank resulting in reduced storage tank volume. In this model, heated molten salt enters the top of the tank which contains a packed bed of quartzite rock and silica sand as the thermal energy storage (TES) medium. The single-tank storage system uses about half the salt that is required by the two-tank system for a required storage capacity. This amounts to a significant reduction in the cost of the storage system. The single tank alternative has also been proven to be cheaper than the option which uses large concrete modules with embedded heat exchangers. Using computer models optimum dimensions are determined to have an round trip efficiency of 84%. Additionally, the cost of the structured concrete thermocline configuration provides the TES capacity cost of $33.80$/kWh thermal compared with $30.04/kWhthermal for a packed-bed thermocline (PBTC) configuration and $46.11/kWh thermal for a two-tank liquid configuration.

14 SOLAR ENERGY↗

Dynamic characterization and performance evaluation of a 10-kW power take-off with mechanical motion rectifier for wave energy conversion

The power take-off (PTO) is a key component for wave energy converters. In this paper, a compact PTO with mechanical motion rectification rated at 10 kW is designed and prototyped, and characterized. A piecewise nonlinear dynamic model is established to describe its unique dynamic property. A linear hydraulic actuator is adopted in lab testing to drive the prototype and the unknown parameters of the dynamic model are identified. Further verification shows that the model can predict the dynamic performance of the PTO well. The test results show that the mechanical motion rectifier-based PTO can achieve overall energy transfer efficiency as high as 65% in regular waves even when the generator is working below the rated electric load and speed. In the irregular wave test, the PTO achieved the overall energy transfer efficiency of 54%, and the peak-to-average ratio acquired during the test is 12.5.

16 TIDAL AND WAVE POWER↗

Performance evaluation of an RFSoC operating in a 1.25 Tesla magnetic field

Here, the Belle II experiment at the SuperKEKB collider is preparing for an upgrade after 2027–2028 to handle higher luminosity and increased background rates. A Radio Frequency System-on-Chip (RFSoC) has been identified as a potential candidate for a common front-end upgrade for subsystems requiring high-speed waveform digitization. The RFSoC's ADC and DAC channels were tested across various magnetic field strengths and a few different field orientations. Power consumption and boot memory functionality were also assessed. Results indicate stable operation with negligible performance degradation, suggesting the RFSoC's viability for high-speed digitization tasks in high magnetic field environments.

47 OTHER INSTRUMENTATION↗

Laboratory Report on Performance Evaluation of Key Constituents during Pre-Treatment of High Level Waste Direct Feed

The analytical capabilities of the 222-S Laboratory are tested against the requirements for an optional start up scenario of the Waste Treatment and Immobilization Plant on the Hanford Site. In this case, washed and in-tank leached sludge would be sent directly to the High Level Melter, bypassing Pretreatment. The sludge samples would need to be analyzed for certain key constituents in terms identifying melter-related issues and adjustment needs. The analyses on original tank waste as well as on washed and leached material were performed using five sludge samples from tanks 241-AY-102, 241-AZ-102, 241-AN-106, 241-AW-105, and 241-SY-102. Additionally, solid phase characterization was applied to determine the changes in mineralogy throughout the pre-treatment steps.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Evaluation of Lower-Energy Energy Storage Alternatives for Full-Hybrid Vehicles; NREL (National Renewable Energy Laboratory)

Automakers have been mass producing hybrid electric vehicles (HEVs) for well over a decade, and the technology has proven to be very effective at reducing per-vehicle fuel use. However, the incremental cost of HEVs such as the Toyota Prius or Ford Fusion Hybrid remains several thousand dollars higher than the cost of comparable conventional vehicles, which has limited HEV market penetration. The b b b b battery energy storage device is typically the component with the greatest contribution toward this cost increment, so significant cost reductions/performance improvements to the energy storage system (ESS) can correspondingly improve the vehicle-level cost/benefit relationship. Such an improvement would in turn lead to larger HEV market penetration and greater aggregate fuel savings. The United States Advanced Battery Consortium (USABC) and the U.S. Department of Energy (DOE) Energy Storage Program managers asked the National Renewable Energy Laboratory (NREL) to collaborate with a USABC Workgroup and analyze the trade-offs between vehicle fuel economy and reducing the decade-old minimum energy requirement for power-assist HEVs. NREL’s analysis showed that significant fuel savings could still be delivered from an ESS with much lower energy storage than the previous targets, which prompted USABC to issue a new set of lower-energy ESS (LEESS) targets that could be satisfied by a variety of technologies. With support from DOE, NREL has developed an HEV test platform for in-vehicle performance and fuel economy validation testing of the hybrid system using such LEESS devices. This presentation describes development of the vehicle test platform, and laboratory as well as in-vehicle evaluation results with alternate energy storage configurations as compared to the production battery system. The alternate energy storage technologies considered include lithium-ion capacitors -- i.e., asymmetric electrochemical energy storage devices possessing one electrode with battery-type characteristics (lithiated graphite) and one with ultracapacitor-type characteristics (carbon) -- and electrochemical double-layer capacitors.

33 ADVANCED PROPULSION SYSTEMS↗

Multi-rate OCDMA system BER performance evaluations for different ML-code sequences

This paper analyzes Bit Error Rate (BER) of Optical Code Division Multiple Access (OCDMA) networks for different class of services which are data, voice, and video; whereas Multi-Length Weighted Modified Prime Code (ML-WMPC) sequences are utilized as a spreading code in with respect to previously used ML-Optical Orthogonal codes. Due to variations in bit rates between the mentioned services, each of them assigns a different WMPC sequence length. In addition, the shot noise, thermal noise, and the Multiple Access Interference (MAI) are included and considered as sources of noise in the BER performance analysis. Furthermore, Pulse Position Modulation, Manchester encoding and MAI cancellation (MAIC) technique are utilized to improve the network performance at a higher number of active users. For analysis, the BER performance calculations are investigated for three types of OCDMA receivers such as simple receiver, receiver with MAIC technique, and receiver with MAIC and Manchester encoding. Moreover, the BER mathematical models have been introduced for different bit rates according to the type of service in the presence of the ML-WMPC and the last of three mentioned OCDMA receivers. Finally, these models and their results are compared with the other existing models, where the results show an improvement in BER performance in the proposed approach.

42 ENGINEERING↗

Performance evaluation of a Terry GS-2 steam impulse turbine with air-water mixtures

Terry steam turbines are widely used in various industries because of their robust design. Within the nuclear power generation industry, they are used in the Reactor Core Isolation Cooling System to remove decay heat during reactor isolation events. During the Fukushima Daiichi nuclear power station disaster in Japan in 2011, the Reactor Core Isolation Cooling System and associated Terry turbine operated for over 70 hours in Unit 2; this runtime is well beyond the expected operating duration. Theories suggest the turbine was subjected to a two-phase inlet flow, which could degrade the turbine performance. In this work, an experimental test rig was constructed to test a full-scale Terry model GS-2 steam turbine under two-phase air/water flows. Steady-state efficiency and torque performance maps of the turbine were developed over a range of turbine inlet pressures (1.38–4.83 bar or 20–70 psia), air mass fractions (0.05–1.0) and rotational speeds up to 4000 RPM. Furthermore, turbine performance followed expected trends with torque varying linearly and efficiency varying quadratically with rotational speed. In addition, high-speed images of the two-phase flow entering the turbine were also analyzed to understand how changes in inlet pressure and air mass fraction affect the flow regime and homogenization. The present tests with air–water two-phase mixtures are an important step towards providing an understanding of the full-scale Terry turbine’s behavior and performance curves under two-phase conditions. The results of this work will be combined with air/water and steam/water data gathered using a small-scale Terry ZS-1 steam turbine in order to understand the scaling relationship between large and small size Terry turbines and fluid pairs. The combined data set will enable further development of analytical models over a wide range of conditions and may be used to provide technical justification for expanded use of the Terry turbines in nuclear power plant safety systems and other systems.

42 ENGINEERING↗

Performance Evaluation of Comparative Vacuum Monitoring and Piezoelectric Sensors for Structural Health Monitoring of Rotorcraft Components

The costs associated with the increasing maintenance and surveillance needs of aging structures are rising at an unexpected rate. Multi-site fatigue damage, hidden cracks in hard-to-reach locations, disbonded joints, erosion, impact, and corrosion are among the major flaws encountered in today’s extensive fleet of aging aircraft and space vehicles. Aircraft maintenance and repairs represent about a quarter of a commercial fleet’s operating costs. The application of Structural Health Monitoring (SHM) systems using distributed sensor networks can reduce these costs by facilitating rapid and global assessments of structural integrity. The use of in-situ sensors for real-time health monitoring can overcome inspection impediments stemming from accessibility limitations, complex geometries, and the location and depth of hidden damage. Reliable, structural health monitoring systems can automatically process data, assess structural condition, and signal the need for human intervention. The ease of monitoring an entire on-board network of distributed sensors means that structural health assessments can occur more often, allowing operators to be even more vigilant with respect to flaw onset. SHM systems also allow for condition-based maintenance practices to be substituted for the current time-based or cycle-based maintenance approach thus optimizing maintenance labor. The Federal Aviation Administration has conducted a series of SHM validation and certification programs intended to comprehensively support the evolution and adoption of SHM practices into routine aircraft maintenance practices. This report presents one of those programs involving a Sandia Labs-aviation industry effort to move SHM into routine use for aircraft maintenance. The Airworthiness Assurance NDI Validation Center (AANC) at Sandia Labs, in conjunction with Sikorsky, Structural Monitoring Systems Ltd., Anodyne Electronics Manufacturing Corp., Acellent Technologies Inc., and the Federal Aviation Administration (FAA) carried out a trial validation and certification program to evaluate Comparative Vacuum Monitoring (CVM) and Piezoelectric Transducers (PZT) as a structural health monitoring solution to specific rotorcraft applications. Validation tasks were designed to address the SHM equipment, the health monitoring task, the resolution required, the sensor interrogation procedures, the conditions under which the monitoring will occur, the potential inspector population, adoption of CVM and PZT systems into rotorcraft maintenance programs and the document revisions necessary to allow for their routine use as an alternate means of performing periodic structural inspections. This program addressed formal SHM technology validation and certification issues so that the full spectrum of concerns, including design, deployment, performance and certification were appropriately considered. Sandia Labs designed, implemented, and analyzed the results from a focused and statistically relevant experimental effort to quantify the reliability of a CVM system applied to Sikorsky S-92 fuselage frame application and a PZT system applied to an S-92 main gearbox mount beam application. The applications included both local and global damage detection assessments. All factors that affect SHM sensitivity were included in this program: flaw size, shape, orientation and location relative to the sensors, as well as operational and environmental variables. Statistical methods were applied to performance data to derive Probability of Detection (POD) values for SHM sensors in a manner that agrees with current nondestructive inspection (NDI) validation requirements and is acceptable to both the aviation industry and regulatory bodies. The validation work completed in this program demonstrated the ability of both CVM and PZT SHM systems to detect cracks in rotorcraft components. It proved the ability to use final system response parameters to provide a Green Light/Red Light (“GO” – “NO GO”) decision on the presence of damage. In additional to quantifying the performance of each SHM system for the trial applications on the S-92 platform, this study also identified specific methods that can be used to optimize damage detection, guidance on deployment scenarios that can affect performance and considerations that must be made to properly apply CVM and PZT sensors. These results support the main goal of safely integrating SHM sensors into rotorcraft maintenance programs. Additional benefits from deploying rotorcraft Health and Usage Monitoring Systems (HUMS) may be realized when structural assessment data, collected by an SHM system, is also used to detect structural damage to compliment the operational environment monitoring. The use of in-situ sensors for health monitoring of rotorcraft structures can be a viable option for both flaw detection and maintenance planning activities. This formal SHM validation will allow aircraft manufacturers and airlines to confidently make informed decisions about the proper utilization of CVM and PZT technology. It will also streamline future regulatory actions and formal certification measures needed to assure the safe application of SHM solutions.

42 ENGINEERING↗

Transactive Electric Water Heater Agent: Design and Performance Evaluation

Electric water heaters (EWHs) are usually equipped with inbuilt thermostats to measure water temperature near the installed positions. Most of the existing EWHs have only two thermostats and often do not have water flow sensor installed. Estimation of state of heat energy (SOHE) inside the hot water tank, which is crucial for efficient control and operation of the EWH, under such imperfect system conditions is very challenging. This paper, therefore, designs a transactive EWH agent (TEWHA) to better estimate SOHE in presence of measurement errors and imperfect system knowledge. The TEWHA, built-in Python, approximates the EWH physics using limited measurements obtained from the ground truth GridLABD model. The performance of the TEWHA is validated against ground truth system for three scenarios: a) ideal condition where TEWHA has complete knowledge of the system, b) imperfect condition where TEWHA has incomplete system information, and c) noised condition where TEWHA measurements contain random errors. Finally, an optimization problem is formulated and solved to demonstrate how TEWHA could use the estimated and measured parameters for a transactive control of EWH. Index Terms—Demand flexibility

demand flexibility, distribution system, electric ↗

Performance evaluation of cosmic ray muon trajectory estimation algorithms

Muons, being elementary particles with minimal interaction with nuclear materials and abundant at sea level, have sparked interest in utilizing them for imaging various applications, such as mining [Borselli et al., Sci. Rep. 12, 22329 (2022)], volcano imaging [Nagamine et al., Nucl. Instrum. Meth. A, 356, 585(1995)], and underground tunnel detection [Guardincerri et al., Pure Appl. Geophys. 174, 2133 (2017)]. Recently, their use in nuclear nonproliferation and safeguard verification has gained attention, particularly in cargo screening for nuclear waste smuggling [Baesso et al., J. Instrum. 9, C10041 (2014)], source localization [L. J. Schultz et al., Nucl. Instrum. Meth. A 519, 687 (2004)], and locating nuclear fuel debris in reactors [Borozdin et al., Phys. Rev. Let. 109, 152501 (2012)]. However, the resolution of muon image reconstruction techniques is limited due to multiple Coulomb scattering (MCS) within the target object. To achieve robust muon tomography, it is crucial to develop efficient and flexible physics-based algorithms that can model the MCS process accurately and estimate the most probable trajectory of muons as they pass through the target object. To address this limitation, in this study, a novel algorithmic approach utilizing the Bayesian probability theory and Gaussian approximation of MCS is chosen. Different energy levels, materials, and target sizes were considered in the evaluations. The results demonstrate that the Generalized Muon Trajectory Estimation (GMTE) algorithm offers significant improvements over currently used algorithms. Across all test scenarios, the GMTE algorithm demonstrated ~50% and 38% increase in precision compared to Straight Line Path (SLP) and Point of Closest Approach (PoCA) algorithms, respectively. Furthermore, it exhibited 10%–35% and 10%–15% increases in muon flux utilization for high and medium Z materials, respectively, compared to the PoCA algorithm. In conclusion, the extensive simulations confirm the enhanced performance and efficiency of the GMTE algorithm, offering improved resolution and reduced measurement time for cosmic ray muon imaging compared to the current SLP and PoCA algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance evaluation of an air conditioning system based on quasi isothermal dehumidifcation

This work presents a first study of novel air conditioning system based on quasi isothermal dehumidification combined with dew-point evaporative cooling through the Maisotsenko cycle (M-Cycle). The dehumidification process is realized in desiccant coated heat exchanger with heat rejection system. The key idea behind the solution is to maximize the cooling effectiveness by creating favourable conditions for dehumidification and evaporative cooling process. This is achieved by rejecting the heat of sorption in the desiccant system and providing cold and dry air for M-Cycle air cooler, which allows the system to be powered by using low-grade heat energy at 50 °C. The analysis is performed on the basis of experimentally validated numerical models of each component combined in a unified model of the system. The goal of the study is to determine the performance of the solution under different operational conditions. In addition two types of M-Cycle air coolers (i.e. cross-flow and regenerative unit) are compared to establish which unit is more suitable as the source of cooling energy for the system. It was established that proposed system is able to provide comfortable room parameters (supply air temperature equal 17 °C and humidity ratio equal 0.010 kg/kg-da) for outdoor air temperatures ranging from 28 to 36 °C and outdoor air humidity ranging from 0.010 to 0.018 kg/kg-da. This means that the proposed solution is able to provide comfortable conditions in temperate and humid climates. Results also indicate that the system consisting of the regenerative M-Cycle HMX allows better cooling load management, offers higher thermal Coefficient of Performance (COP th ) and uses less water compared to the system with the cross-flow HMX. However, the system with cross-flow heat and mass exchanger (HMX) has a relatively greater electrical Coefficient of Performance (COP el ) in most cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗