Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peaking capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Baseload Hydrogen Production Using Nuclear and Renewable Energy: A Comparative Analysis

As the global push towards net zero carbon gains momentum, the demand for clean hydrogen is expected to grow rapidly across various sectors, including transportation, industries and electrical grids. To meet this growing hydrogen demand, baseload hydrogen production facilities capable of providing a continuous and reliable supply of hydrogen will be necessary throughout the world. This paper explores the technoeconomic feasibility of establishing baseload electrolytic hydrogen production facilities in the United States, utilizing different clean generation resources. The key criteria include maintaining a consistent supply of clean hydrogen without putting baseload demand stress to already vulnerable power grid. In order to do that, the proposed facilities will host onsite clean power generation and energy storage technologies. The proposed facilities can capitalize on available investment and production incentives and have ability to export excess electricity to the utility at a bulk price. Several scenarios are considered based on the clean energy resources to support the electrolysis process including light water reactors (LWRs) currently evaluating retirement options, wind, solar PVs, and advanced small modular reactors (SMRs). For each scenario, a hypothetical hydrogen production facility is considered in a location in the US where the primary generation resource is at its peak strength. Comparative analysis in this paper reveal that the nuclear power plants are most economically viable for baseload hydrogen production facilities, outperforming renewable-based facilities with significantly lower levelized cost of hydrogen (LCOH). Even under best-case scenarios for resource availability, incentives and export prices, renewable-based facilities face challenges due to daily and seasonal generation variability, resulting in large installation sizes and lower capacity factors. Among renewable-based facilities, complementarity hybrids, providing more stable power supply, demonstrate superior economics compared to facilities based on a single renewable technology. While LWR-powered facility can achieve a negative LCOH with incentives, SMR-powered facilities can provide economic hydrogen supply with LCOH below $1/kg with high temperature electrolysis option. The analysis in this paper underscores the pivotal role of nuclear energy in the future hydrogen economy.

08 - HYDROGEN↗

Characterizing peak electricity demand for U.S. households: an assessment of end-use loads and demand factors

Understanding household peak electricity demand is critical to evaluate the technical need for electrical infrastructure upgrades. This study characterizes peak loads for existing and new equipment using metered data from a convenience sample of 11,940 U.S. dwellings from four sources, including 911 from two sources with end-use metering. After standardized data cleaning and labeling, we derived descriptive statistics for key metrics, such as maximum demand and demand factors, and developed predictive models relating 60- to 15-min demand for the National Electrical Code (NEC). Mean 15-min maximum demand was 9.7 kW (median 9.0 kW; IQR 7.0–11.5 kW, 95% CI 9.6–9.8 kW), indicating spare capacity in 98% of homes with hypothetical 100 A panels. Maximum demand increased with floor area and number of high-demand loads. Dwelling maximum demand was driven by higher-power, longer-duration heating appliances and vehicle charging, while most user-operated appliances contributed little. Demand factors are used to account for how most devices contribute less than their rated power to maximum demand. Existing load mean demand factors (28%; median 10%; IQR 0–58%; CI 28–29%) were higher than those for new loads (21%; median 7%; IQR 0–35%; CI 20–21%), because new loads changed the timing and magnitude of maximum demand. New high-demand loads had higher than average demand factors (40–60%). Whole dwelling demand factors support the NEC's 40% assumption, but they challenge its conservative 100% treatment of new HVAC. We propose a data-driven 50% demand factor for new equipment, which would align with metered data, improve affordability, and modernize electrical codes.

Appliances↗

Achieving High‐Performance and 2000 h Stability in Anion Exchange Membrane Fuel Cells by Manipulating Ionomer Properties and Electrode Optimization

The primary function of the ionomers that are incorporated into fuel cell electrode catalyst layers is to provide pathways for ion transport between the catalyst active sites and the electrolyte. This is influenced by many variables, including the ion-exchange capacity, water uptake, and molecular weight. In anion exchange membrane fuel cells (AEMFCs), controlling ionomer water uptake is particularly important and tailoring this property in each electrode is an important consideration when looking to maximize cell performance. In this study, three poly(norbornene) tetrablock copolymer ionomers with a range of physical properties are synthesized and incorporated into AEMFC anode and cathode electrodes. Systematic electrode engineering with these ionomers allows the peak power density to be increased by 100% (1.6 W cm -2 → 3.2 W cm -2 ) and the current density at 0.2 V to be increased by 59% (5.9 A cm -2 → 9.4 A cm -2 ). Moreover, the top-performing electrode configuration is tested in an operating AEMFC at the US Department of Energy defined current density of 600 mA cm -2 for 2000 h, showing a record-low voltage decay rate of 15.36 µV h -1 – only 3.65% –a over 2000 h. Here, this work sets a new bar for AEMFCs, reporting the best combination of performance and durability of any AEMFC to date.

08 HYDROGEN↗

In Situ Synthesis of Phosphate-Based CelloMOF as a Promising Separator for Li–Ion Batteries

Nowadays, battery separators play a critical role in determining the sustainability, electrochemical efficiency, and safety of lithium-ion batteries (LIBs). In this contribution, we developed fire-resistant composite membranes called CelloMOF by in situ grafting of metal-organic framework, ZIF-67, onto phosphorylated cellulose nanofibers (P-CNFs) followed by a vacuum filtration process akin to papermaking. The hybrid ZIF-67@P-CNF membrane exhibits superior properties than a polyolefin-based commercial separator (CS) in terms of enhanced thermal and dimensional stability, flame-retardant properties, better surface wettability, and improved electrolyte uptake. Thermal dimensional stability tests revealed that the ZIF-67@P-CNF separator maintained its structure even at 200 °C, whereas CS suffered severe shrinkage, potentially leading to internal short circuits. Combustion tests showed a peak heat release rate (PHRR) of 34.5 W/g and a total heat release (THR) of 1.61 kJ/g for ZIF-67@P-CNF, significantly lower than the PHRR (1111.82 W/g) and THR (40.89 kJ/g) of CS. The composite separator also demonstrated significantly improved wettability, with a contact angle of 32 ± 1.04°, compared to 92 ± 1.07° for CS, highlighting its hydrophilic nature. Electrochemical evaluations in LiFePO 4 /Li half-cells indicated a higher discharge capacity of 149 mA h g -1 at 0.2 C and superior capacity retention of 86% after 50 cycles, outperforming CS (145 mA h g -1 and 84%, respectively). In conclusion, these results underscore the potential of the ZIF-67@P-CNF membrane to advance safe, high-performance LIBs by addressing critical challenges in thermal stability, flame retardancy, and electrolyte compatibility.

ZIF-67↗

Impacts of High Variable Renewable Energy Futures on Electric-Sector Decision Making: Demand-Side Effects

Previous work by the Berkeley Lab describes how high shares of variable renewable energy (VRE) such as wind and solar power could change wholesale electricity price dynamics. These include the timing of when electricity is cheap or expensive, locational differences in the cost of electricity, and the degree of regularity or predictability in those costs. Many decentralized decision-makers on the demand-side may not yet have considered the implications of these possible future changes. In this report, we evaluate the sensitivity of a set of demand-side decisions to different levels of VRE penetration ranging from a low of 5-20% to a high of 40-50%. The analysis builds on hourly wholesale energy and capacity prices in different VRE scenarios for four wholesale markets in the United States for the year 2030 (CAISO, ERCOT, NYISO, and SPP). The principal question for this exploration is whether private and public electric-sector decisions that are made based on assumptions reflecting low VRE levels still achieve their intended objective in a high VRE scenario with 40-50% wind and solar? This scoping report evaluates the impacts of changing patterns of peak system needs on the benefits of demand reductions by examining the altered value of different energy efficiency (EE) measures. Similarly, we investigate new opportunities for large energy consumers that may arise from periods with very low wholesale electricity prices. We calculate the value of new process investments (e.g., hydrogen production and other generalized electro-commodities), showcase the varying value of new product storage investments (such as reservoir extensions at a desalination plant), and estimate the benefits of increased process flexibility that uses electricity as a process-input in addition to traditional fossil fuels (e.g., district energy systems). Finally, many decentralized decision-makers and end-use customers are not directly exposed to wholesale electricity prices but instead receive price signals from their retail electricity rates. As wind and solar shares increase, we compare the economic efficiency of flat retail rates relative to more dynamic time-of-use tariffs with and without critical peak-pricing events.

14 SOLAR ENERGY↗

Land-Based Wind Market Report: 2022 Edition

The U.S. Department of Energy's 2022 edition of its Land-Based Wind Market Report provides an overview of key trends in the U.S. wind power market, with a focus on 2021. You can find a report, data file and presentation on the Files tab, below. Additionally, several data visualizations are available on the Visualizations tab. Despite ongoing supply chain challenges, wind energy in 2021 continued to see strong growth, technology improvements, and low prices in the U.S. Key highlights include: Wind comprises a growing share of electricity supply: U.S. wind power capacity grew at a strong pace in 2021, with the 13.4 GW of new additions representing a $\$20$ billion investment and 32% of all newly added U.S. generation capacity. Wind energy output rose to account for more than 9% of the entire nation’s electricity supply. At least 247 GW of wind are seeking transmission interconnection; 77 GW of this capacity are offshore wind and 19 GW are hybrid plants that pair wind with storage or solar PV. Wind project performance has increased over the decades: The average capacity factor among recently built projects was nearly 40%, considerably higher than projects built earlier. The highest capacity factors are seen in the interior ‘wind belt’ of the country. Turbines continue to get larger: Improved plant performance has been driven by larger turbines mounted on taller towers and featuring longer blades. In 2011, no turbines employed blades that were 115 meters in diameter or larger, but in 2021, 89% of newly installed turbines featured such rotors. Proposed projects indicate that total turbine height will continue to rise. Low wind turbine pricing has pushed down installed project costs over the last decade: Wind turbine prices averaged $\$800$–$\$950$/kW in 2021, a 5% to 10% increase from the year prior but substantially lower than in 2010. The average installed cost of wind projects in 2021 was $\$1,500$/kW, down more than 40% since the peak in 2010, though relatively stable in recent years. The lowest costs were found in Texas and the (non-ISO) West. Wind energy prices are on the rise, but generally remain low, around $\$20$/MWh in the interior of the country with higher prices in the West and East. After topping out above $\$75$/MWh for power purchase agreements (PPAs) executed in 2009, the national average price of wind PPAs has dropped—though supply-chain pressures have resulted in increased prices in recent years. In the interior ‘wind belt’ of the country, recent pricing is around $\$20$/MWh. In the West and East, prices tend to average above $\$30$/MWh. These prices, which are possible in part due to federal tax support, fall below the projected future fuel costs of gas-fired generation. Wind PPA prices are often attractive compared to wind’s grid-system market value: The value of wind in wholesale power markets is affected by the location of wind plants, their hourly output profiles, and how those characteristics correlate with real-time electricity prices and capacity markets. The market value of wind increased in 2021, averaging $\$16$/MWh in MISO, $\$19$/MWh in SPP, $\$23$/MWh in NYISO, $\$31$/MWh in ERCOT, $\$33$/MWh in PJM, $\$44$/MWh in ISO-NE, and $\$48$/MWh in CAISO. The average levelized cost of wind energy was $\$32$/MWh for plants built in 2021: Levelized costs, which exclude the impacts of federal tax incentives, vary across time and geography. The national average stood at $\$32$/MWh in 2021—down substantially historically, though relatively stable in recent years. Levelized costs were lowest in ERCOT, SPP, and the (non-ISO) West. The health and climate benefits of wind in 2021 were larger than its grid-system value, and the combination of all three far exceeds the current levelized cost of wind: Wind generation reduces power-sector emissions of carbon dioxide, nitrogen oxides, and sulfur dioxide. These reductions, in turn, provide public health and climate benefits that vary regionally, but together are economically valued at an average of over $\$90$/MWh-wind for plants built in 2021.

17 WIND ENERGY↗

Harnessing Virtual Power Plants Reliably: Enabling tools for increased observability, controllability, operation, and aggregation of distributed energy resources

Harnessing virtual power plants enhances the integration of distributed energy resources into utility grids for a sustainable energy future. Virtual power plants (VPPs) aggregate DERs to enhance resource adequacy and reduce emissions. U.S. utilities are exploring various technologies to manage DERs effectively. FERC Order 2222 allows DERs to participate in both wholesale and retail markets. Enhancing observability and controllability of behind-the-meter (BTM) DERs is essential for reliable grid operations. A hierarchical control architecture can improve coordination among residential energy resources. Field tests showed nearly 20% energy savings and 30% peak power reduction during grid events. Effective management of DERs requires enhanced situational awareness to prevent grid congestion. Integrating DER management systems (DERMS) with existing planning tools can improve operational security. Near-real-time grid models can validate optimal resource set points against resource uncertainty. Traditional uninterruptible power supplies (UPS) can be upgraded to support grid services and become part of VPPs. Upgrading UPS systems can reduce costs by 75% and unlock significant battery capacity. New battery management systems and grid-aware controllers are essential for optimizing UPS performance. Continued research and development are necessary to address challenges in integrating DERs into utility grids. Encouraging customer participation in pilot programs is vital for the evolution of VPPs. Here, the shift towards price-responsive DERs and VPPs is expected to enhance energy distribution efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Empirical validation and comparison of methodologies to simulate micro and macro-encapsulated PCMs in the building envelope

Thermal Energy Storage (TES) has the potential to shift peak electricity demand. Passive TES is usually implemented in building envelope as micro and macro encapsulated phase change materials (PCM) to shift electric energy demand and therefore requires careful heat transfer analysis. Whole building energy modelling with simplified heat transfer analysis has become extremely important for designers, architects, engineers, and researchers to predict energy performance of buildings. It is important to validate PCM modelling algorithms used in building energy programs to quantify their error and prove their capacity to model different PCM encapsulation types. This study uses data from a microencapsulated PCM and two macroencapsulated PCMs (Bio based PCM and hydrate salts) tested in full-scale using the Advanced Multiscale Building Energy Research (AMBER) Lab located at the Colorado School of Mines and is used to validate a numerical algorithm written in MATLAB language. To approximate the heat transfer through a wall assembly with macroencapsulated PCM pouches, several modelling techniques that can reduce 3D heat transfer characteristics to 1D are explored in this research. A parallel path heat transfer modelling approach is found to give the closest agreement with the experimental data for the pouched PCMs in building envelope applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

California Time-of-Use (TOU) Transition: Effects on Distributed Wind and Solar Economic Potential

Time-of-use (TOU) retail energy rates price electricity differently by the time of day, communicating to consumers the costs of supplying electricity diurnally. This study evaluates the impact of Decision D.15.07-001, which mandates a transition in 2020 to default TOU rates for residential ratepayers in California, on the economic viability of behind-the-meter distributed wind and solar systems. Previous studies have demonstrated that increasing wind and solar generation will materially affect the diurnal cost of wholesale electricity. As retail and wholesale prices become more aligned, this could affect the inter-technology economic viability of distributed generation. We assess economic viability through 'economic potential,' or the amount of generation capacity that exceeds a rate of return of 5.4%. In addition, we identify sensitivities of economic potential to capital costs and other techno-economic factors as well as the specific counties and sectors with substantial economic potential. We find that TOU implementation is projected to moderately increase economic potential of distributed wind and marginally decrease that of distributed solar. Over the long-term as variable renewable energy penetration increases in California, particularly utility-scale solar, net peak load and thus peak prices will shift later in the evening. To the extent that retail rates continue to evolve with wholesale prices, we find the changes could positively affect the value of wind generation more than that of solar generation. Over the scenarios considered, model results indicate realistic pathways to reaching a robust distributed wind market in California though solar economic potential was found to be substantially larger than that of wind.

17 WIND ENERGY↗

Enhancing 2D hydrodynamic flood models through machine learning and urban drainage integration

Two-dimensional hydrodynamic flood models are commonly employed for simulating flood extent and inundation depth. However, the influence of urban drainage network (UDN) is frequently overlooked in these models, potentially compromising their accuracy. Furthermore, the expensive computational costs and longer processing times make them challenging for large-scale hydrodynamic simulation. To address these challenges, this paper develops a machine learning (ML)-driven emulator for an open-source flood model, the Two-dimensional Runoff Inundation Toolkit for Operational Needs (TRITON). A TRITON-ML Emulator (TR-Emulator) that utilizes Convolutional Long Short-Term Memory is developed to capture the spatiotemporal features of flood events based on the outputs from TRITON. We further enhance the emulator by integrating UDN parameters (TR-UDN), such as the flow capacity of drainage pipes, pipe size, and pipe length, via an ML stacking technique to improve the water surface elevation (WSE) simulation. Hurricane Harvey 2017 in Houston, TX is used as the case study. We compare WSE results from TRITON, TR-Emulator, TR-UDN, and the United States Geological Survey (USGS) observations to evaluate the performance of these models. The results indicate that the TR-Emulator effectively replicates the WSE simulated by TRITON. Additionally, TR-UDN performs well in capturing WSE patterns and peak flows, aligning more closely with USGS observations, except in areas with milder slopes where conveyance discrepancies are observed. We further test the generalizability of our ML-based models using another smaller event. This paper shows that the TR-Emulator is effective for users and engineers to emulate a 2D hydrodynamic model, and the enhanced version of the TR-Emulator, TR-UDN, can be an efficient tool for predicting WSEs during urban flooding.

54 ENVIRONMENTAL SCIENCES↗

Self-cleaning and de-pollution efficacies of photocatalytic architectural membranes

Photocatalytic self-cleaning “cool” roofs and walls can maintain high albedos, saving building cooling energy, reducing peak power demand, and mitigating the urban heat island effect. Other environmental benefits result from their de-polluting properties. Specimens from two different photocatalytic architectural membranes and a non-photocatalytic control were exposed alongside vertically, facing west, for two years at three California sites, and retrieved quarterly for testing. Photocatalytic materials showed excellent self-cleaning performance, retaining albedos of 0.74 – 0.75. By contrast, the control material exhibited an albedo loss of up to 0.10, with appreciable soiling observed by scanning electron microscopy. De-pollution capacity was assessed by quantifying NO removal and NOx deposition rates at 60 °C. Furthermore, efficacy varied with exposure location, weather conditions, and the nature of the photocatalytic material. Seasonal effects were observed, with partial inhibition during the dry season and reactivation during the rainy season.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of heating and cooling loads on battery energy storage system sizing in extreme cold climates

Efficient operation of battery energy storage systems requires that battery temperature remains within a specific range. Current techno-economic models neglect the parasitic loads heating and cooling operations have on these devices, assuming they operate at constant temperature. In this work, these effects are investigated considering the optimal sizing of battery energy storage systems when deployed in cold environments. Here, a peak shaving application is presented as a linear programming problem which is then formulated in the PYOMO optimization programming language. The building energy simulation software EnergyPlus is used to model the heating, ventilation, and air conditioning load of the battery energy storage system enclosure. Case studies are conducted for eight locations in the United States considering a nickel manganese cobalt oxide lithium ion battery type and whether the power conversion system is inside or outside the enclosure. The results show an increase of 42% to 300% in energy capacity size, 43% to 217% in power rating, and 43% to 296% increase in capital cost dependent on location. This analysis shows that the heating, ventilation, and air conditioning load can have a large impact on the optimal sizes and cost of a battery energy storage system and merit consideration in techno-economic studies.

25 ENERGY STORAGE↗

Mobile Sorption-based Thermal Battery for Harvesting Low-Temperature Geothermal Energy

Around 20% of the total primary energy in the United States is consumed for thermal demands of buildings such as space cooling, dehumidification, and space heating (EIA 2018). Low-temperature geothermal energy is abundant and can effectively satisfy buildings’ thermal demands. However, low-temperature geothermal energy is underutilized because the energy density of geothermal fluid is too low to justify the costs associated with transporting it between existing geothermal resources and buildings. The mobile sorption-based thermal battery (MSTB) system has been developed using three-phase (i.e., vapor–liquid, solution–solid, crystal) sorption technology to harvest low-temperature heat and store it with a much higher energy density than the geothermal fluid. The energy density of salt crystals is over six times higher than geothermal fluid, which makes long-distance transportation of salt crystals economically feasible. Salt crystals can be used to dehumidify air or provide space cooling in buildings, which alleviates peak demand on the electricity grid by offsetting electricity use for these end uses. This helps improve the grid’s stability and resilience. High-energy storage density, fast crystallization, and dissolution of salt crystals are all critical to the viability and performance of the MSTB system. Therefore, the design and operation of MSTB systems need to ensure effective generation and dissolution of salt crystals inside the MSTB. To achieve this target, this seedling project developed an experimental apparatus for characterizing the crystallization and dissolution processes. The energy density and potential latent cooling capacity of the MSTB are also evaluated based on lab test results. The crystallization results showed that the generated lithium chloride hydrate crystals are fluffy, the crystallization process lasts about 50 min, and the maximum crystal fraction (i.e., the ratio of crystal mass to the mass in the MSTB) can be up to 51.1% of the total mass in the MSTB at a solution flow rate of 1.58 g/s. The dissolution results show that the salt crystals in the MSTB can be fully dissolved within 15–28 min, based on different test conditions. Reducing solution flow rate and cooling water temperature can achieve increased energy storage density and crystal fraction. While the increase in the discharge rate (i.e., latent cooling capacity for dehumidifying air) is achieved by increasing flow rate and temperature of inlet diluted solution, as well as by using a pump for internal solution circulation, the discharge rate increases by 38%, from 0.95 kW to 1.31 kW. Compared with increasing the inlet solution flow rate, power consumption of salt solution transportation can be reduced by using a pump for internal solution circulation. The crystallization test results also showed that the maximum energy storage density is 981.8 kJ/kg, and the maximum discharge rate of the dissolution tests is ≤1.79 kW. Both are above the target values of 900 kJ/kg and 1.75 kW) for this project. The work reported here proves the feasibility and advancement of the MSTB system, which is helpful to the further study and improvement of the MSTB system.

15 GEOTHERMAL ENERGY↗

Study on the Thermal Stabilizing Process of Layered Double Hydroxides in PVC Resin

Poly(vinyl chloride) (PVC) is widely used in various fields and requires the use of thermal stabilizers to enhance its thermal stability during processing because of its poor thermal stability. Layered double hydroxides (LDHs) are widely considered to be one kind of highly efficient and environmentally friendly PVC thermal stabilizer. To investigate the thermal stabilizing process of layered double hydroxides (LDHs) in PVC resin, PVC and MgAl-LDHs powders with different interlayer anions (CO 3 2- , Cl - , and NO 3 - ) were physically mixed and aged at 180 °C. The structure of LDHs at different aging times was studied using XRD, SEM, and FT-IR. The results show that the thermal stabilizing process of LDHs on PVC mainly has three stages. In the first stage, the layers of LDHs undergo a reaction with HCl, which is released during the thermal decomposition of PVC. Subsequently, the ion exchange process occurs between Cl - and interlayer CO 3 2- , resulting in the formation of MgAl-Cl-LDHs. Finally, the layers of MgAl-Cl-LDHs react with HCl slowly. During the thermal stabilizing process of MgAl-Cl-LDHs, the peak intensity of XRD reduces slightly, and no new XRD peak emerges. It indicates that only the first step happens for MgAl-Cl-LDHs. The TG-DTA analysis of LDHs indicates that the interaction of LDHs with different interlayer anions has the following order: NO 3 - < CO 3 2- < Cl - , according to the early coloring in the thermal aging test of PVC composites. The results of the thermal aging tests suggest that LDHs with a weak interaction between interlayer anions and layers can enhance the early stability of PVC significantly. Furthermore, the thermal aging test demonstrates that LDHs with high HCl absorption capacities exhibit superior long-term stabilizing effects on PVC resin. This finding provides a valuable hint for designing an LDHs/PVC resin with a novel structure and excellent thermal stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Behind-the-Meter Energy Storage and Generation in Support of Electrified Rental Car Centers

Electrification of rental car centers at major airports is expected to generate tens of MW in additional power loads. The magnitude of these loads poses challenges including high utility costs, expensive and lengthy distribution capacity upgrades, and disruptions to traditional operation. Behind-the-meter stationary battery storage and onsite photovoltaic generation offer a viable solution to these challenges without impacting the operation and business model of rental car companies, defined by minimal fleet inventory and short vehicle dwell time. Using data-driven syn-thetic charging loads for the rental car center at the Dallas/Fort Worth airport in the United States, we show that optimally-designed and controlled behind - the- meter resources can reduce the lifecycle cost of electrified rental centers by an average 41 % and reduce peak grid demand by 64 %, deferring the need for distribution upgrades or potentially avoiding it altogether.

battery storage↗

Resilient and Cost-Effective Hybrid Li-Ion Battery Energy Storage System for Sites with Solar Generation and Electric Vehicle (EV) Charging (CRADA Final Report, CRD-19-00799)

The batteries of an energy storage system designed for multiple use-cases are traditionally selected to withstand the highest rate at which a battery is discharged relative to its maximum capacity (C-rate) and cycling requirements of the most intense use-case. However, this is not cost-effective given that the price of the batteries is strongly correlated to C-rate and cyclability. We propose to establish design guidelines for a hybrid energy storage system and test an edge controller that uses high-power and high-energy batteries for high- cyclability use cases such as frequency regulation and electric vehicle (EV) charging and low-cost batteries for low-power and low-cyclability use cases such as summer peak loads. The three main objectives of this proposal are (i) establishing sizing guidelines for such a hybrid storage system, (ii) installing a hybrid storage system in the Energy Systems Integration Facility (ESIF) sized based on those guidelines, and (iii) testing an edge controller specific for the system through hardware tests.

14 SOLAR ENERGY↗

Too dim, too bright, and just right: Systems analysis of the Chlamydomonas diurnal program under limiting and excess light

Photosynthetic organisms coordinate their metabolism and growth with diurnal light, which can range in intensity from limiting to excessive. Little is known about how light intensity impacts the diurnal program in Chlamydomonas reinhardtii, or how diurnal rhythms in gene expression and metabolism shape photoprotective responses at different times of day. To address these questions, we performed a systems analysis of synchronized Chlamydomonas populations acclimated to low, moderate, and high diurnal light. Transcriptomic and proteomic data revealed that the Chlamydomonas rhythmic gene expression program is resilient to limiting and excess light: genome-wide, waves of transcripts, and proteins peak at the same times in populations acclimated to stressful light intensities as in populations acclimated to moderate light. Yet, diurnal photoacclimation gives rise to hundreds of gene expression changes, even at night. Time course measurements of photosynthetic efficiency and pigments responsive to excess light showed that high light-acclimated cells partially overcome photodamage in the latter half of the day prior to cell division. Although gene expression and photodamage are dynamic over the diurnal cycle, Chlamydomonas populations acclimated to low and high diurnal light maintain altered photosystem abundance, thylakoid architecture, and non-photochemical quenching capacity through the night phase. This suggests that cells remember or anticipate the light intensities that they have typically encountered during the day. The integrated data constitute an excellent resource for understanding photoacclimation in eukaryotes under environmentally relevant conditions.

Dupuis, Sunnyjoy↗

Exogenous erythropoietin increases hematological status, fat oxidation, and aerobic performance in males following prolonged strenuous training

Abstract This study investigated the effects of EPO on hemoglobin (Hgb) and hematocrit (Hct), time trial (TT) performance, substrate oxidation, and skeletal muscle phenotype throughout 28 days of strenuous exercise. Eight males completed this longitudinal controlled exercise and feeding study using EPO (50 IU/kg body mass) 3×/week for 28 days. Hgb, Hct, and TT performance were assessed PRE and on Days 7, 14, 21, and 27 of EPO. Rested/fasted muscle obtained PRE and POST EPO were analyzed for gene expression, protein signaling, fiber type, and capillarization. Substrate oxidation and glucose turnover were assessed during 90‐min of treadmill load carriage (LC; 30% body mass; 55 ± 5% V̇O 2 peak) exercise using indirect calorimetry, and 6‐6‐[ 2 H 2 ]‐glucose PRE and POST. Hgb and Hct increased, and TT performance improved on Days 21 and 27 compared to PRE ( p < 0.05). Energy expenditure, fat oxidation, and metabolic clearance rate during LC increased ( p < 0.05) from PRE to POST. Myofiber type, protein markers of mitochondrial biogenesis, and capillarization were unchanged PRE to POST. Transcriptional regulation of mitochondrial activity and fat metabolism increased from PRE to POST ( p < 0.05). These data indicate EPO administration during 28 days of strenuous exercise can enhance aerobic performance through improved oxygen carrying capacity, whole‐body and skeletal muscle fat metabolism.

Drummer, Devin J.↗