Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Time resolved optical diagnostics of ZnO plasma plumes in air

We report dynamical evolution of laser ablated ZnO plasma plumes using interferometry and shadowgraphy; 2-D fast imaging and optical emission spectroscopy in air ambient at atmospheric pressure. Recorded interferograms using Nomarski interferometer and shadowgram images at various time delays show the presence of electrons and neutrals in the ablated plumes. The inference drawn from sign change of fringe shifts is consistent with two dimensional images of the plume and optical emission spectra at varying time delays with respect to ablating pulse. Zinc oxide plasma plumes are created by focusing 1.06 μm radiation on to ZnO target in air and 532 nm is used as probe beam.

36 MATERIALS SCIENCE↗

Single-mode fiber, velocity interferometry

In this paper, we describe a velocity interferometer system based entirely on single-mode fiber optics. This paper includes a description of principles used in developing the single-mode velocity interferometry system (SMV). The SMV design is based on polarization-insensitive components. Polarization adjusters are included to eliminate the effects of residual birefringence and polarization dependent losses in the interferometers. Characterization measurements and calibration methods needed for data analysis and a method of data analysis are described. Calibration is performed directly using tunable lasers. During development, we demonstrated its operation using exploding-foil bridge-wire fliers up to 200 m/s. In a final test, we demonstrated the SMV in a gas gun experiment up to 1.2 km/sec. As a basis for comparison in the gas gun experiment, we used another velocimetry technique that is also based on single-mode fiber optics: photonic Doppler velocimetry (PDV). For the gas gun experiment, we split the light returned from a single target spot and performed a direct comparison of the homodyne (SMV) and heterodyne (PDV) techniques concurrently. The two techniques had a negligible mean difference and a 1.5% standard deviation in the one-dimensional shock zone. Within one interferometer delay time after a sudden Doppler shift, a SMV unencumbered by multimode-fiber dispersion exhibits two color beats. These beats have the same period as PDV beats--this interference occurs between the ''recently'' shifted and ''formerly unshifted'' paths within the interferometer. We believe that recognizing this identity between homodyne and heterodyne beats is novel in the shock-physics field. SMV includes the conveniences of optical fiber, while removing the time resolution limitations associated with the multimode delivery fiber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanodiamonds in dusty low-pressure plasmas

Dusty plasmas composed of carbon, hydrogen, and oxygen have been evidenced by optical emission spectroscopy and microwave interferometry, due to the increase in electron energy and the decrease in electron density. These plasmas allow homogeneous synthesis of nanodiamond grains composed of either pure diamond nanocrystals only (2-10 nm in size) or of diamond nanocrystals and some sp{sup 2}-hybridized carbon entities. The control of their size and their microstructure could open ways for a wide range of fields. Their formation from a plasma-activated gaseous phase is also attractive because the formation of nanodiamonds in the universe is still a matter of controversy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Atomic Interferometry with Detuned Counter-Propagating Electromagnetic Pulses

Atomic fountain interferometry uses atoms cooled with optical molasses to 1 μK, which are then launched in a fountain mode. The interferometer relies on the nonlinear Raman interaction of counter-propagating visible light pulses. We present models of these key transitions through a series of Hamiltonians. Our models, which have been verified against special cases with known solutions, allow us to incorporate the effects of non-ideal pulse shapes and realistic laser frequency or wavevector jitter.

42 ENGINEERING↗

MAGIS-100 Atom Source Support Preliminary Design

There are three Atom Sources within the MAGIS-100 experiment, located at the ends and midpoint of the shaft, adjacent to the vacuum tube. Each Atom Source weighs approximately 700 pounds and contains the optical components for the atom interferometry and delivers the Strontium.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

BOLOMETRIC FLUX ESTIMATION FOR COOL EVOLVED STARS

Estimation of bolometric fluxes (F{sub BOL}) is an essential component of stellar effective temperature determination with optical and near-infrared interferometry. Reliable estimation of F{sub BOL} simply from broadband K-band photometry data is a useful tool in those cases were contemporaneous and/or wide-range photometry is unavailable for a detailed spectral energy distribution (SED) fit, as was demonstrated in Dyck et al. Recalibrating the intrinsic F{sub BOL} versus observed F{sub 2.2μm} relationship of that study with modern SED fitting routines, which incorporate the significantly non-blackbody, empirical spectral templates of the INGS spectral library (an update of the library in Pickles) and estimation of reddening, serves to greatly improve the accuracy and observational utility of this relationship. We find that F{sub BOL} values predicted are roughly 11% less than the corresponding values predicted in Dyck et al., indicating the effects of SED absorption features across bolometric flux curves.

79 ASTRONOMY AND ASTROPHYSICS↗

Femtosecond Time-Delay X-Ray Holography

X-ray free-electron lasers (XFELs) will produce photon pulses with a unique and desirable combination of properties. Their short X-ray wavelengths allow penetration into materials and the ability to probe structure at and below the nanometer scale. Their ultra-short duration gives information about this structure at the fundamental time-scales of atoms and molecules. The extreme intensity of the pulses will allow this information to be acquired in a single shot, so that these studies can be carried out on non-repeatable processes or on weakly-scattering objects that will be modified by the pulse. A fourth property of XFEL pulses is their high transverse coherence, which brings the promise of decades of innovation in visible optics to the X-ray regime, such as holography, interferometry, and laser-based imaging. Making an effective use of XFEL pulses, however, will benefit from innovations that are new to both X-ray science and coherent optics. One such innovation is the new method of time-delay X-ray holography [1], recently demonstrated at the FLASH FEL at DESY in Hamburg, to measure the evolution of objects irradiated by intense pulses. One of the pressing questions about the high-resolution XFEL imaging and characterization of non-periodic or weakly-scattering objects is the effect of the intense FEL pulse on the object, during the interaction with that pulse. The method of single-particle diffraction imaging [2] requires a stream of reproducible particles (e.g. a protein complex or virus) inserted into the beam, whereby a coherent X-ray diffraction pattern is recorded. The pulse will completely destroy the object, but if the pulse is short enough the diffraction pattern will represent the undamaged object. This ultrafast flash imaging was demonstrated at the FLASH FEL using test objects that included microfabricated patterns in silicon nitride foils [3]. Those experiments showed that no damage occurred during the 30 fs duration pulse. However, in those experiments the imaging resolution was limited by the long 32 nm wavelength at which the facility was then operating. We wished to dramatically increase our sensitivity to the particles explosions, to be able to increase the understanding of the dynamics of particles and predict the imaging performance at XFELs such as the LCLS. This was done in two ways in a single experiment: by holographically measuring the time evolution of the particle at times after the pulse had pass through the object; and by making an interferometric measurement of the change in the optical path through the object. The experimental technique, time-delay holography, achieved a time resolution better than 3 fs, and a phase sensitivity of better than 3{sup o}, or a sensitivity of < 3 nm of the expansion of the particles.

59 BASIC BIOLOGICAL SCIENCES↗

Nonlinear dispersive similariton: spectral interferometric study

A similariton formed in a passive optical fibre is experimentally found and investigated by spectral interferometry completely characterising the complex radiation field. A nonlinear dispersive character of similariton formation leads to chirp linearisation and spectrotemporal similarity of this similariton. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Continuous phase amplification with a Sagnac interferometer

We describe a phase-amplification technique using a Sagnac interferometer. We monitor the relative phase between two paths of a precisely misaligned interferometer by measuring the average position of a split-Gaussian mode in the dark port. Although we monitor only the dark port, we show that the signal varies linearly with phase and that we can obtain similar sensitivity to balanced homodyne detection. We derive the source of the amplification using classical wave optics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using Strain in the Vadose Zone During Sinusoidal-Rate Well Tests to Characterize an Aquifer

Well tests with sinusoidal variation in pumping rate are appealing because of the ability to filter competing signals and they also can be set up with no net removal of water, which is an advantage at contaminated sites. Current methods of interpreting sinusoidal-rate well tests analyze the phase lag and amplitude of pressure signals in the aquifer. This approach is restricted by the availability of monitoring wells. An alternative approach could be to measure the stain in the vadose zone instead of pressure in the aquifer. The goal of this research is to evaluate the feasibility of using signals from in-situ sensors in the vadose zone to characterize sinusoidal-rate well tests. Well tests with a variety of periods and amplitudes were performed using a well completed in an unconfined saprolite aquifer with a water table at 9m depth at our test site near Clemson, South Carolina. Vertical strain was measured every meter between 1 to 7 m using a distributed optical fiber sensing technique called coherence length gated microwave photonics interferometry (CMPI). A novel packaging system was designed to couple the optical fiber to the saprolite. The results show that strain measured in the vadose zone during sinusoidal-rate pumping varies periodically with amplitudes from 0.1 to 3 microstrain, depending on the amplitude of the sinusoidal pumping rate. Hydraulic heads at similar radial distances were also periodic with changing amplitudes ranging up to ±0.2 meters. The strain in the vadose zone responds to pressure in the underlying aquifer—the strain is tensile when the pressure is falling, and compressive when the pressure is rising. The phase lag between the pumping rate and the strain was 3 min with a pumping period of 15 minutes, and this gives a hydraulic diffusivity of 0.06 m2/s. This is the same diffusivity obtained by analyzing a constant rate pumping test, and it is slightly larger than the diffusivity (0.044 m2/s) obtained by analyzing the phase lag of the pressure in a nearby monitoring well. Strain measurements in the vadose zone could be made with much less cost and effort than installing a deep monitoring well. These results suggest that strain measurements in the vadose zone could be used to supplement monitoring wells, thereby increasing the resolution, and reducing costs of analyzing well tests.

well test, sinusoidal, periodic pumping, strain↗

Ultrafast Plasmonic Control of Second Harmonic Generation

Efficient frequency conversion techniques are crucial to the development of plasmonic metasurfaces for information processing and signal modulation. In principle, nanoscale electric-field confinement in nonlinear materials enables higher harmonic conversion efficiencies per unit volume than those attainable in bulk materials. Here we demonstrate efficient second-harmonic generation (SHG) in a serrated nanogap plasmonic geometry that generates steep electric field gradients on a dielectric metasurface. An ultrafast control pulse is used to control plasmon-induced electric fields in a thin-film material with inversion symmetry that, without plasmonic enhancement, does not exhibit an even-order nonlinear optical response. The temporal evolution of the plasmonic near-field is characterized with ~100 as resolution using a novel nonlinear interferometric technique. The serrated nanogap is a unique platform in which to investigate optically controlled, plasmonically enhanced harmonic generation in dielectric materials on an ultrafast time scale. Lastly, this metamaterial geometry can also be readily extended to all-optical control of other nonlinear phenomena, such as four-wave mixing and sum- and difference-frequency generation, in a wide variety of dielectric materials.

36 MATERIALS SCIENCE↗

The advanced LIGO input optics

The advanced LIGO gravitational wave detectors are nearing their design sensitivity and should begin taking meaningful astrophysical data in the fall of 2015. These resonant optical interferometers will have unprecedented sensitivity to the strains caused by passing gravitational waves. The input optics play a significant part in allowing these devices to reach such sensitivities. Residing between the pre-stabilized laser and the main interferometer, the input optics subsystem is tasked with preparing the laser beam for interferometry at the sub-attometer level while operating at continuous wave input power levels ranging from 100 mW to 150 W. These extreme operating conditions required every major component to be custom designed. These designs draw heavily on the experience and understanding gained during the operation of Initial LIGO and Enhanced LIGO. In this article, we report on how the components of the input optics were designed to meet their stringent requirements and present measurements showing how well they have lived up to their design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Embedded Fiber Optic Sensors for Measuring Transient Detonation/Shock Behavior;Time-of-Arrival Detection and Waveform Determination.

The miniaturization of explosive components has driven the need for a corresponding miniaturization of the current diagnostic techniques available to measure the explosive phenomena. Laser interferometry and the use of spectrally coated optical windows have proven to be an essential interrogation technique to acquire particle velocity time history data in one- dimensional gas gun and relatively large-scale explosive experiments. A new diagnostic technique described herein allows for experimental measurement of apparent particle velocity time histories in microscale explosive configurations and can be applied to shocks/non-shocks in inert materials. The diagnostic, Embedded Fiber Optic Sensors (EFOS), has been tested in challenging microscopic experimental configurations that give confidence in the technique's ability to measure the apparent particle velocity time histories of an explosive with pressure outputs in the tenths of kilobars to several kilobars. Embedded Fiber Optic Sensors also allow for several measurements to be acquired in a single experiment because they are microscopic, thus reducing the number of experiments necessary. The future of EFOS technology will focus on further miniaturization, material selection appropriate for the operating pressure regime, and extensive hydrocode and optical analysis to transform apparent particle velocity time histories into true particle velocity time histories as well as the more meaningful pressure time histories.

Chavez, Marcus Alexander↗

System and method of phase-locked fiber interferometry

A system and method are provided for optical homodyne detection in an optical fiber interferometer. A detection signal is obtained by interfering an optical data signal with a phase-modulated optical reference signal. The modulator for the optical reference signal is phase-locked to an oscillatory modulation waveform. In embodiments, the modulator includes a piezoelectric element. In more specific embodiments, the modulator is a piezoelectric optical fiber-stretcher.

Katzenmeyer, Aaron Michael↗

Uncertainty analysis using Monte Carlo method in the measurement of phase by ESPI

A method for simultaneously measuring whole field in-plane displacements by using optical fiber and based on the dual-beam illumination principle electronic speckle pattern interferometry (ESPI) is presented in this paper. A set of single mode optical fibers and beamsplitter are employed to split the laser beam into four beams of equal intensity.One pair of fibers is utilized to illuminate the sample in the horizontal plane so it is sensitive only to horizontal in-plane displacement. Another pair of optical fibers is set to be sensitive only to vertical in-plane displacement. Each pair of optical fibers differs in longitude to avoid unwanted interference. By means of a Fourier-transform method of fringe-pattern analysis (Takeda method), we can obtain the quantitative data of whole field displacements. We found the uncertainty associated with the phases by mean of Monte Carlo-based technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of Pseudorandom Binary Arrays for Calibration of Surface Profile Metrology Tools

Optical metrology tools, especially for short wavelengths (extreme ultraviolet and x-ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown point-spread function (PSF) of the instruments [G. D. Boreman, Modulation Transfer Function in Optical and Electro-Optical Systems (SPIE, Bellingham, WA, 2001)] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account for because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in the spatial frequency domain as a power spectral density (PSD) distribution [J. W. Goodman, Introduction to Fourier Optics, 3rd ed. (Roberts and Company, Englewood, CO, 2005)]. For example, measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [E. L. Church et al., Opt. Eng. (Bellingham) 18, 125 (1979); J. C. Stover, Optical Scattering, 2nd ed. (SPIE Optical Engineering Press, Bellingham, WA, 1995)]. The distortion of the surface PSD distribution due to the PSF can be modeled with the modulation transfer function (MTF), which is defined over the spatial frequency bandwidth of the instrument. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the system under test. Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. The applicability of the MTF concept to phase map measurements with optical interferometric microscopes needs to be experimentally verified as the optical tool and algorithms may introduce nonlinear artifacts into the process. In previous work [V. V. Yashchuk et al., Proc. SPIE 6704, 670408 (2007); Valeriy V. Yashchuk et al., Opt. Eng. (Bellingham) 47, 073602 (2008)] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudorandom (BPR) gratings. Here, the authors present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as global position systems and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the uniformly redundant array (URA) prescription [E. E. Fenimore and T. M. Cannon, Appl. Opt. 17, 337 (1978)] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and induction coupled plasma etching of silicon. The basic size units were 200, 400, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The MicroMap{trademark}-570 interferometric microscope uses incoherent illumination from a tungsten filament source and common path modulated phase shifting interference to produce a set of interferograms detected on a change coupled device. Mathematical algorithms applied to the datasets yield the surface phase map. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples [Samuel K. Barber et al., Abstract to Optics and Photonics 2009: Optical Engineering and Applications Symposium, San Diego, CA, 2-6 August 2009]. Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-color interferometry and shadowgraphy characterization of an orthogonal double-pulse laser ablation

Orthogonal double pulse laser ablation on aluminum target at atmospheric pressure was studied by time-resolved optical emission spectroscopy, shadowgraphy and two-color interferometry. Studies were realized as a function of the distance from the first pulse plasma induced in air to the sample surface. The evolution of the electron and neutral particles densities were determined by two-color interferometry. Line intensification mechanisms are discussed based on the interferometry results and the plumes interaction dynamics. It was found that the sample heating by the preablation pulse could contribute to the observed emission enhancement.

36 MATERIALS SCIENCE↗

Phase measurement in temporal speckle pattern interferometry signals presenting low-modulated regions by means of the bidimensional empirical mode decomposition

We propose a phase measurement technique to retrieve optical phase distributions coded in noisy temporal speckle pattern interferometry signals presenting regions of adjacent low-modulated pixels, which is based on the bidimensional empirical mode decomposition and the Hilbert transform. It is shown that this approach can effectively remove noise and minimize the influence of large sets of adjacent nonmodulated pixels located in the time series of speckle interferograms. The performance of the phase retrieval approach is analyzed using computer-simulated speckle interferograms modulated with a temporal carrier. The results are also compared with those given by a technique based on the one-dimensional empirical mode decomposition. The advantages and limitations of the proposed approach are finally discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗