Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

AWE neutron spectrometry results from Godiva-IV (NCERC) characterization - Paper 135

In recent years, it was deemed necessary for the Godiva-IV critical assembly - along with other assemblies collectively forming what is now known as the National Critical Experiments Research Center (NCERC) - to relocate to the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). An experiment was proposed (IER-148) under the Nuclear Criticality Safety Program for an international inter-comparison of Nuclear Accident Dosimetry (NAD) using the Godiva-IV assembly, in order to arrest the long term decline in the testing and validation of these systems. Due to the knock-on effect of the change of location on the neutron leakage spectrum, however, new reference points must be established. As a precursor to the intercomparison an additional experiment (IER-147) was proposed with the aim of measuring these reference values for the current Godiva-IV radiation field in the DAF. To establish the reference values Godiva was run in both a sub-critical steady-state mode and a super prompt-critical, pulsed mode. AWE provided neutron spectrometry capabilities in the form of a ROSPEC and Bonner sphere Spectrometer (BSS) for the steady-state experiment, and a Passive Bonner sphere Spectrometer (PBSS) for the pulsed experiment. Neutron leakage spectrum measurements carried out by AWE have been used to determine reference doses around Godiva which can be used for future NAD inter-comparisons. A good comparison of steady-state and pulsed spectra indicates a strong likelihood of being able to relate the power level of both operational methods of the reactor for future work in other fields. Further work is required to determine the fidelity of the thermal peak and it is the intention of AWE to bring additional thermal information to the unfolding process through the incorporation of supplementary activation foils used in the irradiations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiochemical capabilities for astrophysics experiments at the national ignition facility

The Nuclear and Radiochemistry Group at Lawrence Livermore National Laboratory (LLNL) has developed a suite of diagnostics and techniques that can be used for astrophysics experiments at the National Ignition Facility (NIF). Capabilities have been developed to add material to the outside of NIF hohlraum assemblies as well as to the interior of NIF target capsules or the fill gas. The ability to place very small amounts of material close to the NIF target enables activation with very large, short-pulse neutron fluxes. The Solid Radiochemistry Diagnostic can be used to collect solid debris from a NIF shot within 2 h of the execution of a shot, and this can be analyzed for radioactive signatures with or without post-shot chemical processing. The Radiochemical Analysis of Gaseous Samples diagnostic system can be used to collect gaseous products produced during a NIF shot. Capsule doping and radiochemical analysis capabilities at NIF will be discussed. The application of these techniques to astrophysical measurements will be discussed as well as some preliminary results.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Optimization of LIBS Acquisition Parameters for Chemical Analysis on HLW Liquid Solution - 18291

Research programs are currently underway in the Joint CEA-AREVA Vitrification Laboratory (LCV) to develop and optimize Laser Induced Breakdown Spectroscopy (LIBS) for nuclear waste streams analyses. The laboratory has full scale prototypes with the advantage of working on simulated inactive solutions of fission products. LIBS is an elemental chemical analysis technology that uses a short laser pulse to create a micro-plasma on the sample surface. This analytical technique offers many advantages compared to other techniques. It includes a sample preparation-free measurement and an extremely fast measurement time, from a few seconds to a few minutes. This paper presents the LIBS technique available in the laboratory. The first LIBS analyzes results of liquid samples from the off-gas treatment unit integrated on the full scale vitrification process are also presented and discussed. These complex solutions contain suspended particles and up to 30 chemical elements. A vision of an online LIBS analysis cell is also proposed with the development and associated research steps. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvement of density resolution in short-pulse hard x-ray radiographic imaging using detector stacks

We demonstrate that stacking several imaging plates (IPs) constitutes an easy method to increase hard x-ray detection efficiency. Used to record x-ray radiographic images produced by an intense-laser driven hard x-ray backlighter source, the IP stacks resulted in a significant improvement of the radiograph density resolution. We attribute this to the higher quantum efficiency of the combined detectors, leading to a reduced photon noise. Electron-photon transport simulations of the interaction processes in the detector reproduce the observed contrast improvement. Increasing the detection efficiency to enhance radiographic imaging capabilities is equally effective as increasing the x-ray source yield, e.g., by a larger drive laser energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chemical Kinetics for the Oxidation of Californium(III) Ions with Select Radiation-Induced Inorganic Radicals (Cl 2 •– and SO 4 •– )

Despite the availability of transuranic elements increasing in recent years, our understanding of their most basic and inherent radiation chemistry is limited and yet essential for accurate interpretation of their physical and chemical properties. Here, in this work, we explore the transient interactions between trivalent californium ions (Cf 3+ ) and select inorganic radicals arising from the radiolytic decomposition of common anions and functional group constituents, specifically the dichlorine (Cl 2 •- ) and sulfate (SO 4 •- ) radical anions. Chemical kinetics, as measured by integrated electron pulse radiolysis and transient absorption spectroscopy techniques, are presented for the reactions of these two oxidizing radicals with Cf 3+ ions. The derived and ionic strength corrected second-order rate coefficients (k) for these radiation-induced processes are k(Cf 3+ + Cl 2 •- ) = (8.28 ± 0.61) × 10 5 M -1 s -1 and k(Cf 3+ + SO 4 •- ) = (9.50 ± 0.43) × 10 8 M -1 s -1 under ambient temperature conditions (22 ± 1 °C).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An algorithm for charge-integration, pulse-shape discrimination and estimation of neutron/photon misclassification in organic scintillators

Organic scintillators are frequently used for measurements that require sensitivity to both photons and fast neutrons because of their pulse shape discrimination capabilities. In these measurement scenarios, particle identification is commonly handled using the charge-integration pulse shape discrimination method. This method works particularly well for high-energy depositions, but is prone to misclassification for relatively low-energy depositions. A novel algorithm has been developed for automatically performing charge-integration pulse shape discrimination in a consistent and repeatable manner. The algorithm is able to estimate the photon and neutron misclassification corresponding to the calculated discrimination parameters, and is capable of doing so using only the information measured by a single organic scintillator. This paper describes the algorithm and assesses its performance by comparing algorithm-estimated misclassification to values computed via a more traditional time-of-flight estimation. A single data set was processed using four different low-energy thresholds: 40, 60, 90, and 120 keVee. Overall, the results compared well between the two methods; in most cases, the algorithm-estimated values fell within the uncertainties of the TOF-estimated values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Information-Guided Dynamic Nuclear Polarization

A spin ensemble in thermal equilibrium continuously undergoes random fluctuations analogous to those observed in Brownian motion, a process known as spin noise. Here, we investigate the dynamics of a system comprising a spin-1 paramagnetic center and a hyperfine-coupled spin-1/2 nucleus in the vicinity of a level crossing. We theoretically show that nuclear spins polarize efficiently under the combined action of thermal fluctuations and a closed-loop feedback protocol. The latter articulates periodic observations of the electronic magnetization and radio-frequency pulses connecting hybrid states with opposite nuclear spin alignment. Since nuclear polarization emerges from electronic spin fluctuations, not spin order, this microwave-free technique generically benefits from warmer, not colder, operation temperatures. Furthermore, because the spin dynamics at play near a level crossing is rather insensitive to the absolute value of the magnetic field, our work promises opportunities for high-field dynamic nuclear polarization, which is difficult to attain through present methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advanced Ultrafast Spectroscopy for Chemical Detection of Nuclear Fuel Cycle Materials

The development of new signatures and observables from processes related to proliferation activities are often related to the development of technologies. In our physical world, the intensity of observables is linearly related to the input drivers (light, current, voltage, etc.). Ultrafast lasers with high peak energies, opens the door to a new regime where the intensity of the observables is not necessarily linear with the laser energy. Potential nonlinear spectroscopic applications include chemical detection via remote sensing through filament generation, material characterization and processing, chemical reaction specificity, surface phenomena modifications, X-ray production, nuclear fusion, etc. The National Security Directorate laser laboratory is currently working to develop new tools for nonproliferation research with femtosecond and picosecond lasers. Prior to this project, we could only achieve laser energies in the 5 nano-Joule range, preventing the study of nonlinear phenomena. To advance our nonproliferation research into the nonlinear regime we require laser pulses in the milli-Joule (mJ) energy range. We have procured and installed a 35 fs-7 mJ laser, operating at one-kilohertz repetition rate, to investigate elemental and molecular detection of materials in the laboratory with potential applications in remote sensing. Advanced, nonlinear Raman techniques will be used to study materials of interest that are in a matrix of many materials and currently with these nonlinear techniques we can achieve greater than three orders of magnitude signal enhancement. This work studying nuclear fuel cycle materials with nonlinear spectroscopies will advance SRNL research capabilities and grow a core capability within the DOE complex.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Fast broad-band photon detector based on quantum well devices and charge-integrating electronics for non-invasive FEL monitoring

The recent evolution of free-electron lasers has not been matched by the development of adequate beam-monitoring instrumentation. However, for both experimental and diagnostics purposes, it is crucial to keep such photon beams under control, avoiding at the same time the absorption of the beam and the possible destruction of the detector. These requirements can be fulfilled by utilizing fast and non-invasive photon detectors operated in situ, upstream from the experimental station. From this perspective, sensors based on Quantum Well (QW) devices can be the key to detecting ultra-short light pulses. In fact, owing to their high electron mobility, InGaAs/InAlAs QW devices operated at room temperature exhibit sub-nanosecond response times. Their direct, low-energy band gap renders them capable of detecting photons ranging from visible to X-ray. Furthermore, the 2D electron gas forming inside the QW is responsible for a charge amplification mechanism, which increases the charge collection efficiency of these devices. In order to acquire the signals produced by these QW sensors, a novel readout electronics has been developed. It is based on a high-speed charge integrator, which allows short, low-intensity current pulses to be read within a 50-ns window. The integrated signal is acquired through an ADC and the entire process can be performed at a 10-MHz repetition rate. This work provides a detailed description of the development of the QW detectors and the acquisition electronics, as well as reporting the main experimental results, which show how these tools are well suited for the realization of fast, broad-band beam monitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-broadband infrared pump-probe spectroscopy using synchrotron radiation and a tuneable pump

Synchrotron infrared sources have become popular mainly because of their excellent broadband brilliance, which enables spectroscopically resolved spatial-mapping of stationary objects at the diffraction limit. In this article we focus on an often-neglected further advantage of such sources - their unique time-structure - to bring such broadband spectroscopy to the time domain, for studying dynamic phenomenon down to the 100 ps limit. We describe the ultra-broadband (12.5 to 1.1 {mu}m) Fourier transform pump-probe setup, for condensed matter transmission- and reflection-spectroscopy, installed at the X01DC infrared beam-line of the Swiss Light Source (SLS). The optical pump consists of a widely tuneable 100 ps 1 kHz laser system, covering 94% of the 16 to 1.1 {mu}m range. A thorough description of the system is given, including (i) the vector-modulator providing purely electronic tuning of the pump-probe overlap up to 1 ms with sub-ps time resolution, (ii) the 500 MHz data acquisition system interfaced with the experimental physics and industrial control system (EPICS) based SLS control system for consecutive pulse sampling, and (iii) the step-scan time-slice Fourier transform scheme for simultaneous recording of the dual-channel pumped, un-pumped, and difference spectra. The typical signal/noise ratio of a single interferogram in a 100 ps time slice is 300 (measured during one single 140 s TopUp period). This signal/noise ratio is comparable to that of existing gated Globar pump-probe Fourier transform spectroscopy, but brings up to four orders of magnitude better time resolution. To showcase the utility of broadband pump-probe spectroscopy, we investigate a Ge-on-Si material system similar to that in which optically pumped direct-gap lasing was recently reported. We show that the mid-infrared reflection-spectra can be used to determine the optically injected carrier density, while the mid- and near-infrared transmission-spectra can be used to separate the strong pump-induced absorption and inversion processes present at the direct-gap energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear Raman Techniques in Femtosecond Time Resolved Spectroscopy for the Analysis and Control of Molecular Dynamics

The use of four-wave mixing techniques in femtosecond time-resolved spectroscopy has considerable advantages. Due to the many degrees of freedom offered e.g. by coherent anti-Stokes Raman scattering (CARS), the dynamics even of complex systems can be analyzed in detail. Using pulse shaping techniques in combination with a self-learning loop approach, molecular mode excitation can be controlled very efficiently in a multi-photon excitation process. Results obtained from the optimal control of CARS on {beta}-carotene are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the characteristics of a piezoelectric lead zirconate titanate radiation detector using a pulsed xenon source

The detector characteristics of piezoelectric lead zirconate titanate (PZT) were studied by directly irradiating a multilayered PZT detector with 400 MeV/n xenon ions. An extracted beam was processed with a rotating slit. Thus, passed through {approx}10{sup 3} xenon ions were available for 50 to 250 {mu}s. The effect of polarization on the output signal was discussed, and the optimal electrode configuration was determined. The output signal appeared as an isolated pulse whose amplitude was qualitatively understood by the Bethe-Bloch formula. However, the calculated and the observed values differed depending on the rotation speed of the slit. A process that can explain the differences is presented here. The output signal appearing beyond the range of 400 MeV/n xenon ion beam was discussed. The sensitivity was compared with that obtained with hypervelocity collision of dust.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical detection threshold of the proton-acoustic range verification technique

Purpose: Range verification in proton therapy using the proton-acoustic signal induced in the Bragg peak was investigated for typical clinical scenarios. The signal generation and detection processes were simulated in order to determine the signal-to-noise limits. Methods: An analytical model was used to calculate the dose distribution and local pressure rise (per proton) for beams of different energy (100 and 160 MeV) and spot widths (1, 5, and 10 mm) in a water phantom. In this method, the acoustic waves propagating from the Bragg peak were generated by the general 3D pressure wave equation implemented using a finite element method. Various beam pulse widths (0.1–10 μs) were simulated by convolving the acoustic waves with Gaussian kernels. A realistic PZT ultrasound transducer (5 cm diameter) was simulated with a Butterworth bandpass filter with consideration of random noise based on a model of thermal noise in the transducer. The signal-to-noise ratio on a per-proton basis was calculated, determining the minimum number of protons required to generate a detectable pulse. The maximum spatial resolution of the proton-acoustic imaging modality was also estimated from the signal spectrum. Results: The calculated noise in the transducer was 12–28 mPa, depending on the transducer central frequency (70–380 kHz). The minimum number of protons detectable by the technique was on the order of 3–30 × 10{sup 6} per pulse, with 30–800 mGy dose per pulse at the Bragg peak. Wider pulses produced signal with lower acoustic frequencies, with 10 μs pulses producing signals with frequency less than 100 kHz. Conclusions: The proton-acoustic process was simulated using a realistic model and the minimal detection limit was established for proton-acoustic range validation. These limits correspond to a best case scenario with a single large detector with no losses and detector thermal noise as the sensitivity limiting factor. Our study indicated practical proton-acoustic range verification may be feasible with approximately 5 × 10{sup 6} protons/pulse and beam current.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting Reactive Products in Carbon Capture Polymers with Chemical Shift Anisotropy and Machine Learning

Aminopolymers are attractive sorbents for CO 2 direct air capture applications due to their high density of amine groups, which can readily react with atmospheric levels of CO 2 to form chemisorbed species. The identity of these chemisorbed species and the functional groups that form upon oxidative degradation depends on both material properties and processing conditions, forming a variety of carbonyl-type sites such as ammonium carbamates, bicarbonates, carbonates, carbamic acids, ureas, and amides. 13 C solid-state nuclear magnetic resonance (NMR) is often used to help elucidate the identity of these reacted species, but it is challenging due to the narrow chemical shift range of carbonyl sites. Herein, we demonstrate the application of a two-dimensional (2D) chemical shift anisotropy (CSA) recoupling pulse sequence (ROCSA) to obtain CSA tensor values at each isotropic chemical shift, overcoming limitations of isotropic peak resolution. CSA tensor values describe the local chemical environment and can readily differentiate between the chemisorbed and degradation products. To aid identification, we also developed a k-nearest neighbor (kNN) classification model to distinguish the functional groups via their CSA tensor parameters. This methodology was demonstrated on poly(ethylenimine) in γ-Al 2 O 3 exposed to CO 2 and showed that the chemisorbed products are ammonium carbamate and a mixed carbamate–carbamic acid species. The sample was analyzed again after desorption at 100 °C inducing mild degradation, and the remaining products were strongly bound carbamate and urea species. In conclusion, the combination of 2D CSA measurements coupled with a kNN classification model enhances the ability to accurately identify chemisorbed or degradation products in complex carbon capture materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-Channel Integrated Circuits For Use In Research With Radioactive Ion Beams

The Integrated Circuits Design Research Laboratory at Southern Illinois University Edwardsville (SIUE) has been collaborating over the past several years with the Nuclear Reactions Group at Washington University (WU) on the development of a family of custom, multi-channel Integrated Circuits (ICs). To date, the collaboration has successfully produced two micro-chips. The first was an analog shaped and peak sensing chip known as HINP16C (Heavy Ion Nuclear Physics--16 Channel). The second chip, christened PSD8C (Pulse Shape Discrimination--8 Channel), was designed to logically complement (in terms of detector types) the HINP16C chip. The HINP16C chip, for use with solid-state detectors, produces sparsified analog pulse trains for both linear (pulse height) and timing (relative to an external reference) signals. A shaper and peak detector are implemented in the linear branch, and a pseudo Constant-Fraction Discriminator (CFD) and Time-to-Voltage Converter (TVC) are implemented in the logic/timing branch. The internal and external gain options make the chip suitable for use in a wide variety of applications. PSD8C greatly simplifies the pulse-processing electronics needed for large arrays of scintillation detectors. As the PSD8C employs user-controlled, multi-region charge integration, particle identification is inherent in the design. Each of the three pulse-height sub-channels consists of a gated integrator with eight programmable charging rates and an externally programmable gate generator that defines the start (with 4 time ranges) and the width (with 4 time ranges) of the gate, relative to an external discriminator signal. Moreover, each channel on the chip also contains a TVC. This paper describes the design, capabilities, and features of the HINP16C and PSD8C ICs along with a description of how the chips are being used. It also discusses modifications and enhancements which have been made to both chips and their associated prototypical systems in order to improve ease of use and increase performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fundamental Drop Dynamics and Mass Transfer Experiments to Support Solvent Extraction Modeling Efforts

In support of the Nuclear Energy Advanced Modeling Simulation Safeguards and Separations (NEAMS SafeSep) program, the Idaho National Laboratory (INL) worked in collaboration with Los Alamos National Laboratory (LANL) to further a modeling effort designed to predict mass transfer behavior for selected metal species between individual dispersed drops and a continuous phase in a two phase liquid-liquid extraction (LLE) system. The purpose of the model is to understand the fundamental processes of mass transfer that occur at the drop interface. This fundamental understanding can be extended to support modeling of larger LLE equipment such as mixer settlers, pulse columns, and centrifugal contactors. The work performed at the INL involved gathering the necessary experimental data to support the modeling effort. A custom experimental apparatus was designed and built for performing drop contact experiments to measure mass transfer coefficients as a function of contact time. A high speed digital camera was used in conjunction with the apparatus to measure size, shape, and velocity of the drops. In addition to drop data, the physical properties of the experimental fluids were measured to be used as input data for the model. Physical properties measurements included density, viscosity, surface tension and interfacial tension. Additionally, self diffusion coefficients for the selected metal species in each experimental solution were measured, and the distribution coefficient for the metal partitioning between phases was determined. At the completion of this work, the INL has determined the mass transfer coefficient and a velocity profile for drops rising by buoyancy through a continuous medium under a specific set of experimental conditions. Additionally, a complete set of experimentally determined fluid properties has been obtained. All data will be provided to LANL to support the modeling effort.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pulse superimposition calculational methodology for estimating the subcriticality level of nuclear fuel assemblies.

One of the most reliable experimental methods for measuring the subcriticality level of a nuclear fuel assembly is the Sjoestrand method applied to the reaction rate generated from a pulsed neutron source. This study developed a new analytical methodology simulating the Sjoestrand method, which allows comparing the experimental and analytical reaction rates and the obtained subcriticality levels. In this methodology, the reaction rate is calculated due to a single neutron pulse using MCNP/MCNPX computer code or any other neutron transport code that explicitly simulates the delayed fission neutrons. The calculation simulates a single neutron pulse over a long time period until the delayed neutron contribution to the reaction rate is vanished. The obtained reaction rate is then superimposed to itself, with respect to the time, to simulate the repeated pulse operation until the asymptotic level of the reaction rate, set by the delayed neutrons, is achieved. The superimposition of the pulse to itself was calculated by a simple C computer program. A parallel version of the C program is used due to the large amount of data being processed, e.g., by the Message Passing Interface (MPI). The analytical results of this new calculation methodology have shown an excellent agreement with the experimental data available from the YALINA-Booster facility of Belarus. This methodology can be used to calculate Bell and Glasstone spatial correction factor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-purity germanium semiconductor modeling in the detector response function toolkit

In this study, we have extended the detector response function toolkit (DRiFT) to provide modeling capabilities of semiconductor sensors. DRiFT provides realistic nuclear instrumentation response by post-processing Monte-Carlo N-particle (MCNP®) radiation transport outputs. MCNP® is capable of modeling radiation transport in complex environments, but has limited detector physics and readout electronics modeling capabilities. Semiconductor detector response can be calculated with a high-fidelity for a flexible range of environments by utilizing MCNP® to simulate radiation interactions inside of detector volumes, and then using DRiFT to model charge transport and signal formation in the semiconductor, as well as the readout electronics. DRiFT models charge transport in the semiconductor, the preamplifier, shaping amplifier, pulse pile-up, and electronic noise to generate detector response. The semiconductor application in DRiFT can model a range of semiconductor materials, shapes, and sizes; and is demonstrated here for a large volume coaxial high-purity germanium (HPGe) detector. Here, we compare detector response functions of a coaxial HPGe detector with measurement of 60 Co, 133 Ba, and 137 Cs at varying count rates, and we conduct a parameter study to demonstrate the effect of changing parameters in the DRiFT simulation. The HPGe detector response function shows excellent agreement with measurements of difference sources with varying dead times and count rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗