Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “molecular imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Large-Scale Structure of the Molecular Gas in Taurus Revealed by High Spatial Dynamic Range Spectral Line Mapping

Viewgraph topics include: optical image of Taurus; dust extinction in IR has provided a new tool for probing cloud morphology; observations of the gas can contribute critical information on gas temperature, gas column density and distribution, mass, and kinematics; the Taurus molecular cloud complex; average spectra in each mask region; mas 2 data; dealing with mask 1 data; behavior of mask 1 pixels; distribution of CO column densities; conversion to H2 column density; variable CO/H2 ratio with values much less than 10(exp -4) at low N indicated by UV results; histogram of N(H2) distribution; H2 column density distribution in Taurus; cumulative distribution of mass and area; lower CO fractional abundance in mask 0 and 1 regions greatly increases mass determined in the analysis; masses determined with variable X(CO) and including diffuse regions agrees well with the found from L(CO); distribution of young stars as a function of molecular column density; star formation efficiency; star formation rate and gas depletion; and enlarged images of some of the regions with numerous young stars. Additional slides examine the origin of the Taurus molecular cloud, evolution from HI gas, kinematics as a clue to its origin, and its relationship to star formation.

molecular clouds↗

H2 and H I emission line imaging of the ring nebula (NGC 6720)

Infrared emission-line images of the v = 1-0 S(1) transition of molecular hydrogen and Br-gamma recombination line of atomic hydrogen which cover the entire extent of NGC 6720, the Ring nebula. The maps presented here are the highest angular resolution images of these transitions yet produced for this object and have very low relative positional uncertainty. As a result, the spatial stratification of the ionized and shocked molecular zones within the nebula is clearly resolved. These data, and data from the Infrared Astronomical Satellite, are used to determine the H2, H I, and dust mass within the nebula. Energy sources for the dust heating, formation and destruction of the H2, and overall evolution of the nebula are also discussed.

Greenhouse, Matthew A.↗

Giant Molecular Clouds and High-Mass Star Formation in the Milky Way

We are conducting an extensive investigation of high-mass (OB) star formation within the dense cores of giant molecular clouds (GMCS) throughout the first Galactic quadrant of the Milky Way using enhanced resolution Infrared Astronomical Satellite (IRAS) images in combination with high-resolution ground-based observations in millimeter wave molecular transitions and radio continuum. As part of this investigation several resolution enhancement algorithms are applied to the IRAS data, including the HIgh RESolution (HIRES) algorithm developed at the IRAS Processing and Analysis Center (IPAC), as well as others ("pixon" image reconstruction). In addition, as part of a related study, we have completed a large survey of the CO emission in the first Galactic quadrant using the 15-element array detector (QUARRY) with the Five College Radio Astronomy Observatory (FCRAO) 14 m antenna, which provides sampling at an angular resolution of 50", comparable to that attained in the reprocessed IRAS data. Both of these data sets are compared with a sample of ultra-compact (UC) H II regions taken from a high-resolution multi-wavelength (6 and 20 cm) radio survey of the Galactic plane using the NRAO Very Large Array (VLA). Selected regions are observed in 1.3 mm continuum, which has proven to be particularly sensitive to the dust column density. Extensive observations of molecular clouds at high resolution in CO, CS and HCN are combined with the reprocessed IRAS high-resolution images to give a more complete picture of the physical conditions and kinematics of high-mass star forming GMCS. Our goals are to study in detail the morphology, structure, and rate of high-mass star formation within GMCs throughout the Galactic disk from the inner edge of the molecular ring to the outer Galaxy.

Source record↗

Simultaneous imaging of vibrational, rotational, and electronic wave-packet dynamics in a triatomic molecule

Light-induced molecular dynamics often involve the excitation of several electronic, vibrational, and rotational states. Since the ensuing electronic and nuclear motion determines the pathways and outcomes of photoinduced reactions, our ability to monitor and understand these dynamics is crucial for molecular physics, physical chemistry, and photobiology. However, characterizing this complex motion represents a significant challenge when different degrees of freedom are strongly coupled. In this Letter, we demonstrate how the interplay between vibrational, rotational, and electronic degrees of freedom governs the evolution of molecular wave packets in the low-lying states of strong-field-ionized sulfur dioxide. Using time-resolved Coulomb explosion imaging (CEI) and quantum mechanical wave packet simulations, we directly map the bending vibrations of the molecule, show how the vibrational wave packet is influenced by molecular alignment, and elucidate the consequences of nuclear motion for the coupling between the two lowest electronic states of the cation. Furthermore, our results demonstrate that multicoincident CEI can be an efficient experimental tool for characterizing coupled electronic and nuclear motion in polyatomic molecules.

Atomic & molecular processes in external fields↗

Synchrotron infrared nano-spectroscopy and -imaging

Infrared (IR) spectroscopy has evolved into a powerful analytical technique to probe molecular and lattice vibrations, low-energy electronic excitations and correlations, and related collective surface plasmon, phonon, or other polaritonic resonances. In combination with scanning probe microscopy, near-field infrared nano-spectroscopy and -imaging techniques have recently emerged as a frontier in imaging science, enabling the study of complex heterogeneous materials with simultaneous nanoscale spatial resolution and chemical and quantum state spectroscopic specificity. Here, we describe synchrotron infrared nano-spectroscopy (SINS), which takes advantage of the low-noise, broadband, high spectral irradiance, and coherence of synchrotron infrared radiation for near-field infrared measurements across the mid- to far-infrared with nanometer spatial resolution. This powerful combination provides a qualitatively new form of broadband spatio-spectral analysis of nanoscale, mesoscale, and surface phenomena that were previously difficult to study with IR techniques, or even any form of micro-spectroscopy in general. We review the development of SINS, describe its technical implementations, and highlight selected examples representative of the rapidly growing range of applications in physics, chemistry, biology, materials science, geology, and atmospheric and space sciences.

47 OTHER INSTRUMENTATION↗

Fluorescence imaging of individual ions and molecules in pressurized noble gases for barium tagging in 136Xe

Abstract The imaging of individual Ba 2+ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba 2+ ion imaging inside a high-pressure xenon gas environment. Ba 2+ ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with scan area of 1 × 1 cm 2 located inside 10 bar of xenon gas. This form of microscopy represents key ingredient in the development of barium tagging for neutrinoless double beta decay searches in 136 Xe. This also provides a new tool for studying the photophysics of fluorescent molecules and chemosensors at the solid-gas interface to enable bottom-up design of catalysts and sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The source of the relativistic particles in the galactic center arc

Three fields in the molecular cloud M0.20-0.033, located near the midpoint of the filamentary 'Galactic center arc,' have been imaged in the CS J = 2-1 line with the OVRO millimeter interferometer. Several molecular clumps have been found to coincide with the endpoints of a number of the arc's nonthermal filaments (NTFs), suggesting that the relativistic particles present along the filaments originate in these molecular cloudlets. The most striking correlation involves a clump that is elongated along the direction of a pair of NTFs, and that approximately coincides with both their endpoints. These observations thus provide clues to the particle acceleration mechanism operative in the Galactic center arc: magnetic energy is likely liberated as the ambient field, tangled by the clumps' motions, reconnects in the advancing clumps' leading, externally ionized, surface layers.

Serabyn, E.↗

Molecular View of Protein Crystal Growth: Molecular Interactions, Surface Reconstruction and Growth Mechanism

Studies of the growth and molecular packing of tetragonal lysozyme crystals suggest that there is an underlying molecular growth mechanism, in addition to the classical one involving screw dislocation/2D) nucleation growth. These crystals are constructed by strongly bonded molecular chains forming helices about the 43 axes. The helices are connected to each other by weaker bonds. Crystal growth proceeds by the formation of these 4(sub 3) helices, which would explain some unexpected observations by earlier investigators, such as bimolecular growth steps on the (110) face. Another consequence of these molecular considerations is that only one of two possible packing arrangements could occur on the crystal faces and that their growth unit was at least a tetramer corresponding to the 4(sub 3) helix. Two new high resolution atomic force microscopy (AFM) techniques were developed to directly confirm these predictions on tetragonal lysozyme crystals. Most earlier investigations of protein crystal growth with AFM were in the low resolution mode which is adequate to investigate the classical growth mechanisms, but cannot resolve molecular features and mechanisms. Employing the first of the newly developed techniques, high resolution AFM images of the (110) face were compared with the theoretically constructed images for the two possible packing arrangements on this face. The prediction that the molecular packing arrangement of these faces corresponded to that for complete 4(sub 3) helices was confirmed in this manner. This investigation also showed the occurrence of surface reconstruction on protein crystals. The molecules on the surface of the (110) face were found to pack closer along the 4(sub 3) axes than those in the interior. The second new AFM technique was used to follow the growth process by measuring the dimensions of individual growth units on the (110) face. Linescans across a growth step, performed near the saturation limit of the crystals, allowed the growth unit dimensions to be measured as they were being incorporated into the crystal. These measurements showed that growth on the (110) face proceeded by the formation of new 4(sub 3) helices from the addition of many growth units of at least tetramer size. This is the first time that a time-resolved AFM technique has been used to observe individual molecular events during crystal growth.

Nadarajah, Arunan↗

Ultrasensitive Photothermal Spectroscopy: Harnessing the Seebeck Effect for Attogram-Level Detection

Molecular-level spectroscopy is crucial for sensing and imaging applications, yet detecting and quantifying minuscule quantities of chemicals remain a challenge, especially when they surface adsorb in low numbers. Here, we introduce a photothermal spectroscopic technique that enables the high selectivity sensing of adsorbates with an attogram detection limit. Our approach utilizes the Seebeck effect in a microfabricated nanoscale thermocouple junction, incorporated into the apex of a microcantilever. We observe minimal thermal mass exhibited by the sensor, which maintains exceptional thermal insulation. The temperature variation driving the thermoelectric junction arises from the nonradiative decay of molecular adsorbates’ vibrational states on the tip. We demonstrate the detection of photothermal spectra of physisorbed trinitrotoluene (TNT) and dimethyl methylphosphonate (DMMP) molecules, as well as representative polymers, with an estimated mass of 10 -18 g.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tailoring Fibre Structure Enabled by X-ray Analytics for Targeted Biomedical Applications

The rising interest in designing fibres via spinning techniques combining the properties of various polymeric materials into advanced functionalised materials is directed towards targeted biomedical applications such as drug delivery, wearable sensors or tissue engineering. Understanding how these functional polymers exhibit multiscale structures ranging from the molecular level to nano-, micro-and millimetre scale is a key prerequisite for their challenging applications that can be addressed by a non-destructive X-ray based analytical approach. X-ray multimodalities combining X-ray imaging, scattering and diffraction allow the study of morphology, molecular structure, and the analysis of nano-domain size and shape, crystallinity and preferential orientation in 3D arrangements. The incorporation of X-ray analytics in the design process of polymeric fibers via their nanostructure under non-ambient conditions (i.e. temperature, mechanical load, humidity…) allows for efficient optimization of the fabrication process as well as quality control along the product lifetime under operating environmental conditions. Here, we demonstrate the successful collaboration between the laboratory of Biomimetic Textiles and Membranes and the Center of X-ray Analytics at Empa for the design, characterisation and optimisation of advanced functionalised polymeric fibrous material systems.

60 APPLIED LIFE SCIENCES↗

Quantum Light Imaging of the Plant Root─Rhizobacteria─System Using iLOV Fluorescence

It has been demonstrated recently that the use of specific quantum states of light for two-photon microscopy can lead to a substantial reduction of the intensity of light needed for the imaging of biological objects. This opens new ways to better understand the delicate mechanisms of the interactions of living organisms in the rhizosphere on an extended time scale without optical damage or alteration of their native behavior. Herein, we report a successful realization of entangled two-photon excited fluorescence microscopy of wheat plant roots and a set of biological samples, including purified iLOV protein, bacterial cells expressing iLOV, and combination of these under an extremely low excitation intensity. The entangled two-photon coupling strength of iLOV was modeled using electronic structure calculations which demonstrated that the FMN chromophore in the iLOV protein has an entangled two-photon absorption (ETPA) cross section that is large enough for imaging using weak quantum light for fluorescence excitation. Successful imaging of plant-associated Pantoea sp. YR343 cells expressing iLOV validates the feasibility of using iLOV as a molecular label for characterizing plant-microbe interactions based on entangled photon imaging. In conclusion, the results demonstrate the advantageous use of entangled photon imaging under noninvasive and nondestructive conditions.

Varnavksi, Oleg [Univ. of Michigan, Ann Arbor, MI ↗

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy for rapid, label-free biological imaging

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy is a label-free imaging approach that provides detailed chemical information at high spatial resolution in a sample through nonlinear, coherent excitation of molecular vibrations and detection of Raman spectra. While its utility for biological imaging has been demonstrated, many aspects of this technique must mature before it can be widely adopted. One of the areas of required improvement is imaging speed—most BCARS implementations involve sample rastering, which limits imaging speed. Beam scanning can provide faster BCARS imaging but presents some unique challenges. Here, we describe a beam-scanning BCARS microscopy system that improves spatial resolution twofold and imaging speed by fivefold over a previous beam-scanning implementation. These enhancements were enabled by an improvement in supercontinuum power and the use of a sCMOS camera for its high data transfer rate and low read noise. Implementation of the sCMOS camera required correction for the significant pixel-to-pixel background and photon response nonuniformity. Here, we report on the method that we implemented for calibrating and correcting the pixel-to-pixel differences in sCMOS camera noise.

Dixon, Jessica Z. [Georgia Institute of Technology↗

HH55 and its energy source

Imaging and spectroscopic observations of HH55 in the Lupus molecular cloud are presented. Cohen and Schwartz (1987) have shown that HH55 is apparently not excited by the nearby T Tau star RU Lup as once thought but rather by the coincident FIR point source 15533 - 3742 extracted from IRAS coadded images. The optical counterpart of this IR source is identified as an active, relatively unobscured M-dwarf star. The forbidden emission lines observed in the stellar spectrum exhibit slight asymmetries to blueshifted velocities. Deconvolution of the emission lines reveals a weak moderate-velocity (-100 km/sec) wind component and a stronger emission component whose velocity is very close to that of the star.

Heyer, Mark H.↗

Characterization of Humanized Mouse Model of Organophosphate Poisoning and Detection of Countermeasures via MALDI-MSI

Organophosphoate (OP) chemicals are known to inhibit the enzyme acetylcholinesterase (AChE). Studying OP poisoning is difficult because common small animal research models have serum carboxylesterase, which contributes to animals’ resistance to OP poisoning. Historically, guinea pigs have been used for this research; however, a novel genetically modified mouse strain (KIKO) was developed with nonfunctional serum carboxylase (Es1 KO) and an altered acetylcholinesterase (AChE) gene, which expresses the amino acid sequence of the human form of the same protein (AChE KI). KIKO mice were injected with 1xLD50 of an OP nerve agent or vehicle control with or without atropine. After one to three minutes, animals were injected with 35 mg/kg of the currently fielded Reactivator countermeasure for OP poisoning. Postmortem brains were imaged on a Bruker RapifleX ToF/ToF instrument. Data confirmed the presence of increased acetylcholine in OP-exposed animals, regardless of treatment or atropine status. More interestingly, we detected a small amount of Reactivator within the brain of both exposed and unexposed animals; it is currently debated if reactivators can cross the blood–brain barrier. Further, we were able to simultaneously image acetylcholine, the primary affected neurotransmitter, as well as determine the location of both Reactivator and acetylcholine in the brain. This study, which utilized sensitive MALDI-MSI methods, characterized KIKO mice as a functional model for OP countermeasure development.

2-PAM↗

Plasmonics-Enhanced Optical Imaging Systems for Bioenergy Research

This final report summarizes the key accomplishments of the project entitled “Plasmonics-Enhanced Optical Imaging Systems for Bioenergy Research”. The goal of this project is aimed at developing innovative and improved imaging instrumentation for visualization and quantitative characterization of biomarkers related to molecular processes and cellular function in living plants. This project focused on three specific aims: 1) Development of Advanced Multimodal Optical Sensing And Imaging Combinatory (MOSAIC) System for SERS biosensing and bioimaging. 2) Evaluation of MOSAIC technologies for sensing and imaging gene expression in plant systems using plasmonic nanoprobes. 3) Application of MOSAIC techniques to bioenergy research.

47 OTHER INSTRUMENTATION↗

Integrated Biophysical Modeling and Image Analysis: Application to Neuro-Oncology

Central nervous system (CNS) tumors come with vastly heterogeneous histologic, molecular, and radiographic landscapes, rendering their precise characterization challenging. The rapidly growing fields of biophysical modeling and radiomics have shown promise in better characterizing the molecular, spatial, and temporal heterogeneity of tumors. Integrative analysis of CNS tumors, including clinically acquired multi-parametric magnetic resonance imaging (mpMRI) and the inverse problem of calibrating biophysical models to mpMRI data, assists in identifying macroscopic quantifiable tumor patterns of invasion and proliferation, potentially leading to improved (a) detection/segmentation of tumor subregions and (b) computer-aided diagnostic/prognostic/predictive modeling. This article presents a summary of (a) biophysical growth modeling and simulation,(b) inverse problems for model calibration, (c) these models' integration with imaging workflows, and (d) their application to clinically relevant studies. We anticipate that such quantitative integrative analysis may even be beneficial in a future revision of the World Health Organization (WHO) classification for CNS tumors, ultimately improving patient survival prospects.

60 APPLIED LIFE SCIENCES↗

Long-Wavelength PtSi Infrared Detectors Fabricated by Incorporating a P+ Doping Spike Grown by Molecular Beam Epitaxy

By incorporating a 1-nm-thick p+ doping spike at the PtSi/Si interface, we have successfullydemonstrated extended cutoff wavelengths of PtSi Schottky infrared detectors in the long wavelengthinfrared (LWIR) regime for the first time. The extended cutoff wavelengths resulted from thecombined effects of an increased electric field near the silicide/Si interface due to the p+ dopingspike and the Schottky image force. The p+ doping spikes were grown by molecular bema epitaxy at450 degrees C using elemental boron as the dopant source, with doping concentrations ranging from 5x 10^(19) to 2 x 10^(20) cm^(-3). Transmission electron microscopy indicated good crystallinequality of the doping spikes. The cutoff wavelengths were shown to increase with increasing dopingconcentrations of the p+ spikes. Thermionic emission dark current characteristics were observed andphotoresponse in the LWIR regime was demonstrated.

Maserjian, J.↗

Mosaic-Detector-Based Fluorescence Spectral Imager

A battery-powered, pen-sized, portable instrument for measuring molecular fluorescence spectra of chemical and biological samples in the field has been proposed. Molecular fluorescence spectroscopy is among the techniques used most frequently in laboratories to analyze compositions of chemical and biological samples. Heretofore, it has been possible to measure fluorescence spectra of molecular species at relative concentrations as low as parts per billion (ppb), with a few nm spectral resolution. The proposed instrument would include a planar array (mosaic) of detectors, onto which a fluorescence spectrum would be spatially mapped. Unlike in the larger laboratory-type molecular fluorescence spectrometers, mapping of wavelengths to spatial positions would be accomplished without use of relatively bulky optical parts. The proposed instrument is expected to be sensitive enough to enable measurement of spectra of chemical species at relative concentrations <1 ppb, with spectral resolution that could be tailored by design to be comparable to a laboratory molecular fluorescence spectrometer. The proposed instrument (see figure) would include a button-cell battery and a laser diode, which would generate the monochromatic ultraviolet light needed to excite fluorescence in a sample. The sample would be held in a cell bounded by far-ultraviolet-transparent quartz or optical glass. The detector array would be, more specifically, a complementary metal oxide/ semiconductor or charge-coupled- device imaging photodetector array, the photodetectors of which would be tailored to respond to light in the wavelength range of the fluorescence spectrum to be measured. The light-input face of the photodetector array would be covered with a matching checkerboard array of multilayer thin film interference filters, such that each pixel in the array would be sensitive only to light in a spectral band narrow enough so as not to overlap significantly with the band of an adjacent pixel. The wavelength interval between adjacent pixels (and, thus, the spectral resolution) would typically be chosen by design to be approximately equal to the width of the total fluorescence wavelength range of interest divided by the number of pixels. The unitary structure comprising the photodetector array overlaid with the matching filter array would be denoted a hyperspectral mosaic detector (HMD) array.

Son, Kyung-Ah↗