Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “missing values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

296 records · Page 17

Aera-Mip: Emission Pathways, Remaining Budgets, and Carbon Cycle Dynamics Compatible With 1.5 and 2 °C Global Warming Stabilization

While international climate policies now focus on limiting global warming to well below 2 °C or pursuing a 1.5 °C level of global warming, the climate modelling community has not provided an experimental design in which all Earth system models (ESMs) converge and stabilize at the same prescribed global warming levels. This gap hampers accurate estimations based on comprehensive ESMs of the carbon emission pathways and budgets needed to meet such agreed warming levels and of the associated climate impacts under temperature stabilization. Here, we apply the Adaptive Emission Reduction Approach (AERA) with ESMs to provide such simulations in which all models converge at 1.5 and 2.0 °C warming levels by adjusting their emissions over time. These emission-driven simulations provide a wide range of emission pathways and resulting atmospheric CO 2 projections for a given warming level, uncovering uncertainty ranges that were previously missing in the traditional Coupled Model Intercomparison Project (CMIP) scenarios with prescribed greenhouse gas concentration pathways. Meeting the 1.5 °C warming level requires a 40 % (full model range: 7 % to 76 %) reduction in multi-model mean CO 2 -forcing-equivalent (CO 2 -fe) emissions from 2025 to 2030, a 98 % (57 % to 127 %) reduction from 2025 to 2050, and a stabilization at 1.0 (−1.7 to 2.9) PgC yr−1 from 2100 onward after the 1.5 °C global warming level is reached. Meeting the 2.0 °C warming level requires a 47 % (8 % to 92 %) reduction in multi-model mean CO 2 -fe emissions until 2050 and a stabilization at 1.7 (−1.5 to 2.7) PgC yr−1 from 2100 onward. The on-average positive emissions under stabilized global temperatures are the result of a decreasing transient climate response to cumulative CO 2 -fe emissions over time under stabilized global warming. This evolution is consistent with a slightly negative zero emissions commitment – initially assumed to be zero – and leads to an increase in the post-2025 CO 2 -fe emission budget by a factor of 2.2 (−0.8 to 6.9) by 2150 for the 1.5 °C warming level and a factor of 1.4 (0.9 to 2.4) for the 2.0 °C warming level compared to its first estimate in 2025. The median CO 2 -only carbon budget by 2150, relative to 2020, is 800 GtCO 2 for the 1.5 °C warming level and 2250 GtCO 2 for the 2.0 °C warming level. These median values exceed the median IPCC AR6 estimates by 60 % for the 1.5 °C warming level and 67 % for 2.0 °C. Some of the differences may be explained by the choice of the mitigation scenario for non-CO 2 radiative agents. Our simulations highlight shifts in carbon uptake dynamics under stabilized temperature, such as a cessation of the carbon sinks in the North Atlantic and in tropical forests. On the other hand, the Southern Ocean remains a carbon sink centuries after temperatures stabilize. Overall, this new type of warming-level-based emission-driven simulation offers a more coherent assessment across climate models and opens up a wide range of possibilities for studying both the carbon cycle and climate impacts, such as extreme events, under climate stabilization.

Adaptive Emission Reduction Approach↗

Development of Long-Lifetime Pulsed Gas Valves for Pulsed Electric Thrusters

It is advantageous for gas-fed pulsed electric thrusters to employ pulsed valves so propellant is only flowing to the device during operation. The propellant utilization of the thruster will be maximized when all the gas injected into the thruster is acted upon by the fields produced by the electrical pulse. Gas that is injected too early will diffuse away from the thruster before the electrical pulse can act to accelerate the propellant. Gas that is injected too late will miss being accelerated by the already-completed electrical pulse. As a consequence, the valve must open quickly and close equally quickly, only remaining open for a short duration. In addition, the valve must have only a small amount of volume between the sealing body and the thruster so the front and back ends of the pulse are as coincident as possible with the valve cycling, with very little latent propellant remaining in the feed lines after the valve is closed. For a real mission of interest, a pulsed thruster can be expected to pulse at least 10(exp 10) - 10(exp 11) times, setting the range for the number of times a valve must open and close. The valves described in this paper have been fabricated and tested for operation in an inductive pulsed plasma thruster (IPPT) for in-space propulsion. In general, an IPPT is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged, producing a high-current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed, it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. The valve characteristics needed for the IPPT application require a fast-acting valve capable of a minimum of 10(exp 10) valve actuation cycles. Since even 10(exp 9) cycles is well above anything demonstrated, this lower value was selected as the design point for the present work. The valve seal must remain leak-tight throughout operation, and the body must maintain a low internal leakage at relatively high operating temperatures. The full set of design requirements used for this program are summarized in Table 1. In this work, we describe two pulsed gas valves that have been fabricated to have long lifetime and demonstrate the characteristics listed above. The first is a miniaturized, conventional electromagnet-based valve while the second is a piezoelectric-based valve design. The conventional valve, shown in Fig. 1, is opened by use of a solenoid electromagnetic actuator. When current is applied to the solenoid coil, magnetic forces pull the plunger away from the valve seat, allowing fluid to flow through the valve. Removal of electrical current permits the spring and fluid pressure to seat the plunger, halting the flow of fluid. The valve body is fabricated from 304L corrosion resistant steel (CRES) and while the parts that form the magnetic circuit are fabricated from 430 CRES. This material does not have optimum magnetic properties, but its corrosion resistance permits incorporation into a design without requiring an additional plating process. A viton O-ring compound (Parker V0884-75), selected for its mechanical strength at elevated temperatures, was used for the valve seat seal. The design was based solely on the use of analytical sizing calculations, as opposed to a more rigorous finite element analysis. While this valve is small and relatively lightweight, it does not represent a design that is optimized for mass and/or a given volume envelope. The piezoelectric valve is a "puller" valve design. Applying a voltage to the piezo crystal causes it to elongate and pull a pintle off the seat, opening the valve. The valve seal consists of the pintle with an external, spherically-formed tip fabricated from Inconel 625 and the seat fabricated from Inconel 718 and possessing a spherical surface that permits the pintle to align with the valve body centerline after each cycle, maintaining the circumferential metal-on-metal seal. The contact stress on the valve pintle is expected in the worst case to be 96.5 MPa (14 ksi), which is well below the work hardening value of 413.7 MPa (60 ksi) for Inconel 615. Results presented in this work will compare the performance of each valve, both to each other and to the valve design requirements given in Table 1. In general, both valves meet all the performance envelope requirements, but the piezoelectric valve consumes considerably less power and has a faster response time over the conventional solenoid-driven valves.

Burkhardt, Wendel M.↗

Encryption for Remote Control via Internet or Intranet

A data-communication protocol has been devised to enable secure, reliable remote control of processes and equipment via a collision-based network, while using minimal bandwidth and computation. The network could be the Internet or an intranet. Control is made secure by use of both a password and a dynamic key, which is sent transparently to a remote user by the controlled computer (that is, the computer, located at the site of the equipment or process to be controlled, that exerts direct control over the process). The protocol functions in the presence of network latency, overcomes errors caused by missed dynamic keys, and defeats attempts by unauthorized remote users to gain control. The protocol is not suitable for real-time control, but is well suited for applications in which control latencies up to about 0.5 second are acceptable. The encryption scheme involves the use of both a dynamic and a private key, without any additional overhead that would degrade performance. The dynamic key is embedded in the equipment- or process-monitor data packets sent out by the controlled computer: in other words, the dynamic key is a subset of the data in each such data packet. The controlled computer maintains a history of the last 3 to 5 data packets for use in decrypting incoming control commands. In addition, the controlled computer records a private key (password) that is given to the remote computer. The encrypted incoming command is permuted by both the dynamic and private key. A person who records the command data in a given packet for hostile purposes cannot use that packet after the public key expires (typically within 3 seconds). Even a person in possession of an unauthorized copy of the command/remote-display software cannot use that software in the absence of the password. The use of a dynamic key embedded in the outgoing data makes the central-processing unit overhead very small. The use of a National Instruments DataSocket(TradeMark) (or equivalent) protocol or the User Datagram Protocol makes it possible to obtain reasonably short response times: Typical response times in event-driven control, using packets sized .300 bytes, are <0.2 second for commands issued from locations anywhere on Earth. The protocol requires that control commands represent absolute values of controlled parameters (e.g., a specified temperature), as distinguished from changes in values of controlled parameters (e.g., a specified increment of temperature). Each command is issued three or more times to ensure delivery in crowded networks. The use of absolute-value commands prevents additional (redundant) commands from causing trouble. Because a remote controlling computer receives "talkback" in the form of data packets from the controlled computer, typically within a time interval < or =1 s, the controlling computer can re-issue a command if network failure has occurred. The controlled computer, the process or equipment that it controls, and any human operator(s) at the site of the controlled equipment or process should be equipped with safety measures to prevent damage to equipment or injury to humans. These features could be a combination of software, external hardware, and intervention by the human operator(s). The protocol is not fail-safe, but by adopting these safety measures as part of the protocol, one makes the protocol a robust means of controlling remote processes and equipment by use of typical office computers via intranets and/or the Internet.

Lineberger, Lewis↗

The anomaly of the CMB power with the latest Planck data

Abstract The lack of power anomaly is an unexpected feature observed at large angular scales in the maps of Cosmic Microwave Background (CMB) produced by the COBE, WMAP andPlancksatellites. This signature, which consists in a missing of power with respect to that predicted by the ΛCDM model, might hint at a new cosmological phase before the standard inflationary era.The main point of this paper is taking into account the latestPlanckpolarisation data to investigate how the CMB polarisation improves the understanding of this feature. With this aim, we apply to the latestPlanckdata, both PR3 (2018) and PR4 (2020) releases, a new class of estimators capable of evaluating this anomaly by considering temperature and polarisation data both separately and in a jointly way. This is the first time that the PR4 dataset has been used to study this anomaly. To critically evaluate this feature, taking into account the residuals of known systematic effects present in thePlanckdatasets, we analyse the cleaned CMB maps using different combinations of sky masks, harmonic range and binning on the CMB multipoles.Our analysis shows that the estimator based only on temperature data confirms the presence of a lack of power with a lower-tail-probability (LTP), depending on the component separation method, ≤ 0.33% and ≤ 1.76% for PR3 and PR4, respectively. To our knowledge, the LTP≤ 0.33% for the PR3 dataset is the lowest one present in the literature obtained fromPlanck2018 data, considering thePlanckconfidence mask. We find significant differences between these two datasets when polarisation is taken into account most likely due to a different level of systematics. Especially, the analysis with PR3 data, unlike that with PR4, seems to point towards a lack of power at large scales also for polarisation.Moreover, we also show that for the PR3 dataset the inclusion of the subdominant polarisation information provides estimates that are less likely accepted in a ΛCDM cosmological model than the only-temperature analysis over the entire harmonic-range considered. In particular, at ℓ max = 26, we found that no simulation has a value as low as the data for all the pipelines.

Astronomy & Astrophysics↗

Evaluation of New Additions to OLI Software in Predicting Mercuric and Mercurous Species in Liquid Waste Operations

Speciation of mercury during the pretreatment steps of tank waste processing is critical to successful mercury removal prior to vitrification during Liquid Waste Operations (LWO) at SRS. OLI software has been used to predict mercury speciation and activity throughout LWO. The OLI software operates based on a thermodynamic framework called the Mixed Solvent Electrolyte (MSE) framework. The MSE framework allows prediction in theoretically infinitely dilute to concentrated mixtures (e.g., purely solute solutions). Before modification to the MSE framework databanks, certain critical mercury species were missing in the MSE databank, and some thermodynamic data needed to be updated for the OLI software to accurately predict mercury chemical species in SRS waste tanks. To better reflect streams across LWO, new mercury species were integrated into the MSE database. To evaluate the changes to the OLI MSE framework per the Technical Task Request (TTR) and the Task Technical and Quality Assurance Plan (TTQAP), waste stream compositions from Tanks 38, 43, and Tank 50 decontaminated salt solution (DSS) were used as model inputs. Models were developed and executed using both the old and new databases. Compositional analyses from caustic Tank 50 DSS and caustic Tanks 38 and 43 were used as the input streams. These streams represent the most comprehensive chemical data sets where both mercury and tank constituents were measured together. Results for Tank 50 DSS predict HgO as the predominant species in both databases. Both methyl and dimethyl Hg species are present when the new database is ‘on’ and are not predicted with the new database turned ‘off’. The new database predicts a greater amount of HgO and a greater fraction of it in the solid phase. Pourbaix diagrams (potential vs. pH) generated for each Tank 50 DSS were identical regardless of which database was used. Elemental Hg and HgO were predicted in the water stable region under basic conditions. Tanks 38 and 43 follow similar trends as the Tank 50 DSS models. Unlike Tanks 38 and 50 DSS, the Tank 43 Pourbaix plot shows a region of stability for an aqueous HgOHCO3 - species between approximately pH 7-11. In all streams, when MeHg+ is included in the inputs, the new database predicts aqueous MeHgOH as the dominant species. If elemental or dimethyl mercury is in the waste stream, the new database model predicts they are unchanged and remain in those states and quantities. Additionally, the total mercury values are reported for both the measured input data and the OLI output data for all considered tanks. The summary indicates that the percentage error between the measured and calculated values is less than 1% in all cases The reconciliations and generation of the Pourbaix diagrams for Tank 50 DSS took approximately ten times longer with the new database ‘on’. In addition, over the course of that time, models with the new database ‘on’ were more likely to crash or display an error. Some modest performance improvements were noted when modeling with an i7 processor versus an i5. An example error is found in Appendix A. Furthermore, Appendix B provides V&V for two chemical systems analyzed with the OLI software, results were satisfactory. It is recommended to utilize the new databases (i.e., HCO.ddb and SR-Hg.ddb) in future Savannah River Mission Completion applications of OLI to represent pseudo steady-state. Furthermore, the integration and utilization of the new databases (i.e., HCO.ddb and SR-Hg.ddb) in modeling applications (e.g., Aspen) is also recommended.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Classifying thermodynamic cloud phase using machine learning models

Vertically resolved thermodynamic cloud-phase classifications are essential for studies of atmospheric cloud and precipitation processes. The Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Thermodynamic Cloud Phase (THERMOCLDPHASE) value-added product (VAP) uses a multi-sensor approach to classify the thermodynamic cloud phase by combining lidar backscatter and depolarization, radar reflectivity, Doppler velocity, spectral width, microwave-radiometer-derived liquid water path, and radiosonde temperature measurements. The measured pixels are classified as ice, snow, mixed phase, liquid (cloud water), drizzle, rain, and liq_driz (liquid+drizzle). We use this product as the ground truth to train three machine learning (ML) models to predict the thermodynamic cloud phase from multi-sensor remote sensing measurements taken at the ARM North Slope of Alaska (NSA) observatory: a random forest (RF), a multi-layer perceptron (MLP), and a convolutional neural network (CNN) with a U-Net architecture. Evaluations against the outputs of the THERMOCLDPHASE VAP with 1 year of data show that the CNN outperforms the other two models, achieving the highest test accuracy, F1 score, and mean intersection over union (IOU). Analysis of ML confidence scores shows that ice, rain, and snow have higher confidence scores, followed by liquid, while mixed, drizzle, and liq_driz have lower scores. Feature importance analysis reveals that the mean Doppler velocity and vertically resolved temperature are the most influential data streams for ML thermodynamic cloud-phase predictions. Lidar measurements exhibit lower feature importance due to rapid signal attenuation caused by the frequent presence of persistent low-level clouds at the NSA site. The ML models' generalization capacity is further evaluated by applying them at another Arctic ARM site in Norway using data taken during the ARM Cold-Air Outbreaks in the Marine Boundary Layer Experiment (COMBLE) field campaign. The models demonstrated similar performance to that observed at the NSA site. Finally, we evaluate the ML models' response to simulated instrument outages and signal degradation and show that a CNN U-Net model trained with input channel dropouts performs better when input fields are missing.

ARM Aerial Facility↗

Measuring Tropospheric Winds from Space Using a Coherent Doppler Lidar Technique

The global measurement of tropospheric wind profiles has been cited by the operational meteorological community as the most important missing element in the present and planned observing system. The most practical and economical method for obtaining this measurement is from low earth orbit, utilizing a Doppler lidar (laser radar) technique. Specifically, this paper will describe the coherent Doppler wind lidar (CDWL) technique, the design and progress of a current space flight project to fly such a system on the Space Shuttle, and plans for future flights of similar instruments. The SPARCLE (SPAce Readiness Coherent Lidar Experiment) is a Shuttle-based instrument whose flight is targeted for March, 2001. The objectives of SPARCLE are three-fold: Confirm that the coherent Doppler lidar technique can measure line-of-sight winds to within 1-2 m/s accuracy; Collect data to permit validation and improvement of instrument performance models to enable better design of future missions; and Collect wind and backscatter data for future mission optimization and for atmospheric studies. These objectives reflect the nature of the experiment and its program sponsor, NASA's New Millennium Program. The experiment is a technology validation mission whose primary purpose is to provide a space flight validation of this particular technology. (It should be noted that the CDWL technique has successfully been implemented from ground-based and aircraft-based platforms for a number of years.) Since the conduct of the SPARCLE mission is tied to future decisions on the choice of technology for free-flying, operational missions, the collection of data is intrinsically tied to the validation and improvement of instrument performance models that predict the sensitivity and accuracy of any particular present or future instrument system. The challenges unique to space flight for an instrument such as SPARCLE and follow-ons include: Obtaining the required lidar sensitivity from the long distance of orbit height to the lower atmosphere; Maintaining optical alignments after launch to orbit, and during operations in "microgravity"; Obtaining pointing knowledge of sufficient accuracy to remove the speed of the spacecraft (and the rotating Earth) from the measurements; Providing sufficient power (not a problem on the Shuttle) and cooling to the instrument. The paper will describe the status and challenges of the SPARCLE project, the value of obtaining wind data from orbit, and will present a roadmap to future instruments for scientific research and operational meteorology.

Miller, Timothy L.↗

Assessment of the Short-Term Radiometric Stability between Terra MODIS and Landsat 7 ETM+ Sensors

The Landsat 7 (L7) Enhanced Thematic Mapper (ETM+) sensor was launched on April 15th, 1999 and has been in operation for over nine years. It has six reflective solar spectral bands located in the visible and shortwave infrared part of the electromagnetic spectrum (0.5 - 2.5 micron) at a spatial resolution of 30 m. The on-board calibrators are used to monitor the on-orbit sensor system changes. The ETM+ performs solar calibrations using on-board Full Aperture Solar Calibrator (FASC) and the Partial Aperture Solar Calibrator (PASC). The Internal Calibrator Lamp (IC) lamps, a blackbody and shutter optics constitute the on-orbit calibration mechanism for ETM+. On 31 May 2003, a malfunction of the scan-line corrector (SLC) mirror assembly resulted in the loss of approximately 22% of the normal scene area. The missing data affects most of the image with scan gaps varying in width from one pixel or less near the centre of the image to 14 pixels along the east and west edges of the image, creating a wedge-shaped pattern. However, the SLC failure has no impacts on the radiometric performance of the valid pixels. On December 18, 1999, the Moderate Resolution Imaging Spectroradiometer (MODIS) Proto-Flight Model (PFM) was launched on-board the NASA's EOS Terra spacecraft. Terra MODIS has 36 spectral bands with wavelengths ranging from 0.41 to 14.5 micron and collects data over a wide field of view angle (+/-55 deg) at three nadir spatial resolutions of 250 m, 500 in 1 km for bands 1 to 2, 3 to 7, and 8 to 36, respectively. It has 20 reflective solar bands (RSB) with spectral wavelengths from 0.41 to 2.1 micron. The RSB radiometric calibration is performed by using on-board solar diffuser (SD), solar diffuser stability monitor (SDSM), space-view (SV), and spectro-radiometric calibration assembly (SRCA). Through the SV port, periodic lunar observations are used to track radiometric response changes at different angles of incidence (AOI) of the scan mirror. As a part of the AM Constellation satellites, Terra MODIS flies approximately 30 minutes behind L7 ETM+ in the same orbit. The orbit of L7 is repetitive, circular, sunsynchronous, and near polar at a nominal altitude of 705 km (438 miles) at the Equator. The spacecraft crosses the Equator from north to south on a descending node between 10:00 AM and 10:15 AM. Circling the Earth at 7.5 km/sec, each orbit takes nearly 99 minutes. The spacecraft completes just over 14 orbits per day, covering the entire Earth between 81 degrees north and south latitude every 16 days. The longest continuous imaging swath that L7 sensor can collect is for a 14-minute subinterval contact period which is equivalent to 35 full WRS-2 scenes. On the other hand, Terra can provide the entire corresponding orbit with wider swath at any given ETM+ collection without contact time limitation. There are six spectral matching band pairs between MODIS (bands 3, 4, 1, 2, 6, 7) and ETM+ (bands 1, 2, 3, 4, 5, 7) sensor. MODIS has narrower spectral responses than ETM+ in all the bands. A short-term radiometric stability was evaluated using continuous ETM+ scenes within the contact period and the corresponding half orbit MODIS scenes. The near simultaneous earth observations (SNO) were limited by the smaller swath size of ETM+ (187 km) as compared to MODIS (2330 km). Two sets of continuous granules for MODIS and ETM+ were selected and mosaiced based on pixel geolocation information for non cloudy pixels over the North American continent. The Top-of- Atmosphere (TOA) reflectances were computed for the spectrally matching bands between ETM+ and MODIS over the regions of interest (ROI). The matching pixel pairs were aggregated from a finer to a coarser pixel resolution and the TOA reflectance values covering a wide dynamic range of the sensors were compared and analyzed. Considering the uncertainties of the absolute calibration of the both sensors, radiometric stability was verified for the band pairs. The Railroad Valley Playa, Nada (RVPN) was included in the path of this continuous orbit, which served as a verification point between the shortterm and the long-term trending results from previous studies. This work focuses on monitoring the short-term on-orbit stability of MODIS and the ETM+ RSB. It also provides an assessment of the absolute calibration differences between the two sensors over their wide dynamic ranges.

Choi, Taeyoung↗