Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Design of compact ultrafast microscopes for single- and multi-shot imaging with MeV electrons

Ultrafast high-energy electron microscopy, taking advantage of strong interaction of electrons with matter while minimizing space charge problems, can be used to address a wide range of grand challenges in basics energy sciences. However, MeV-electron lenses are inherently bulky and expensive, preventing them from acceptance in a broad scientific community. In this article, we report our novel design of a compact, low-cost imaging-lens system for MeV-electrons based on quadrupole multiplets, including triplet, quadruplet and quintuplet, both symmetric and asymmetric. We compare optical performance of quadrupole-based condenser, objective and projector lenses with that of the traditional round-lenses and discuss the strategy for their practical use in constructing MeV-electron microscopes for high spatial and temporal resolution single- and multi-shot imaging. Combining the compound electron-optical system with a photocathode radiofrequency (RF) gun, such a MeV electron microscope can be fit into a smallsized laboratory for ultrafast observations and measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resolution of the Electron Microscope at the Atomic Scale

The importance of atomic-resolution electron microscopy as a tool for structure analysis lies in its ability to produce images in which each peak corresponds to the position of an atom (or atomic column) within the specimen. Being able to distinguish between atoms (or columns) that appear close together when projected in the chosen viewing direction depends on the resolution of the microscope. Knowledge of the resolution of any particular electron microscope is crucial to judge if its resolution is appropriate for the specimen. In addition, resolution quality will determine the precision of measured atom positions.

A-OK↗

Humidity Exposure Enhances Microscopic Mobility in a Room-Temperature Ionic Liquid in MXene

Present and future electrochemical devices employing advanced electrode and electrolyte materials are expected to operate in diverse environments, where they are exposed to variable conditions, such as changing humidity levels. Such conditions can possibly alter the microscopic mechanisms that influence the electrochemical performance. Here in this paper, using quasi-elastic neutron scattering and molecular dynamics simulations, we investigate the influence of humidity exposure on a room-temperature ionic liquid, [EMIm + ][Tf 2 N – ], in Ti 3 C 2 T x MXene. Absorbed water enhances the microscopic mobility of confined [EMIm + ][Tf 2 N – ], even though the ionic liquid itself is not very hygroscopic. The absorbed water molecules predominantly reside on the termination groups of the more hydrophilic MXene layers, thereby displacing the ions from the surface and facilitating their motions in the MXene matrix.

36 MATERIALS SCIENCE↗

Microscopic Dynamics in an Ionic Liquid Augmented with Organic Solvents

We introduce the complex microscopic dynamics of 1-butyl-3-methyl-imidazolium bis(trifluromethylsulfonyl)imide, [Bmim + ][TFSI – ], ionic liquid mixed with organic solvents to improve its properties for energy storage applications. To probe the microscopic dynamics on different length and time scales, we have used different neutron scattering spectrometers for quasielastic neutron scattering measurements to compare the effects of solvation in several organic solvents with nearly the same dipole moment but broadly varying bulk diffusivity. The ionic liquid–solvent mixtures show a nanoscopic phase separation into an ionic liquid-rich and a solvent-rich phase, as revealed by the model-free dynamic susceptibility data and further corroborated by the cluster histogram analysis of molecular dynamics (MD) simulation. In both phases, we observe a long-range translational mobility of the [Bmim + ] cation, which scales with the bulk diffusivities of the organic solvents; this correlation becomes stronger in the solvent-rich phase. Furthermore, various localized motion modes of the [Bmim + ] cation are observed. A combination of neutron scattering and MD simulations reveals the parameters governing solvent-controlled diffusivity in an ionic liquid, which helps formulate new electrolytes optimized for effective energy storage devices.

25 ENERGY STORAGE↗

Quantitative Measurements of the Temperature-Dependent Microscopic and Macroscopic Dynamics of a Molecular Dopant in a Conjugated Polymer

Understanding the nature of dopant dynamics in the solid state is critical for improving the longevity and stability of organic electronic devices and for optimizing the doping-induced solubility control (DISC) patterning method. Here in this work, we use quasi-elastic neutron scattering (QENS) and fluorescence quenching techniques to develop a comprehensive picture of both the microscopic and macroscopic dynamics of the soluble p-type molecular dopant tetrafluoromethyloxycarbonyltricyanoquinodimethane (F4MCTCNQ) in the conductive polymer poly(3-hexylthiophene-2,5-diyl) (P3HT). Specifically, fast dynamics (ps–ns) of the dopant, such as the methyl and the methoxycarbonyl group rotations, are observed in QENS experiments. From confocal fluorescence microscope experiments, longer-range/slower dopant diffusion (ms–days) is captured. However, in order to fit these data, it is necessary to incorporate a Langmuir isotherm equilibrium between the neutral and ionized dopant molecules. Ionized F4MCTCNQ is strongly favored by the equilibrium, but it diffuses 3 orders of magnitude slower than neutral species. Moreover, the macroscopic diffusion is found to depend mostly on the minority concentration of neutral dopant molecules in the film. In conclusion, the global diffusion coefficient of the monoester-substituted dopant F4MCTCNQ is shown to be more than an order of magnitude smaller than that of the widely used dopant F4TCNQ.

36 MATERIALS SCIENCE↗

Electrolyte-Dependent, “Microscopically Irreversible” H-Atom Transfer Kinetics of Ce-Based Metal–Organic Framework, Ce-MOF-808

Redox reactions at the interface of metal oxides and protic electrolytes almost always involve protons and electrons in equal amounts. Given the stoichiometry, these proton-coupled electron transfer (PCET) reactions are thermochemically equivalent to net H-atom transfer (HAT) reactions. The correlation between the chemical nature of solid catalysts and HAT kinetics has been employed for decades as the design principle for energy-relevant reactions (e.g., reactions of 2H + /H 2 ). More recently, chemists have experimentally determined that a change in liquid electrolytes that alters the microenvironment at the redox-active sites has an equally profound impact on electrocatalysis involving PCET/HAT. Yet, precise correlations between the chemical nature of electrolytes and the PCET kinetics are, to date, rare in the literature. Herein, we report our findings using the Ce-based metal−organic framework, Ce-MOF-808, as a model system. Each Ce 6 (μ 3 −O) 4 (μ 3 − OH) 4 (OH) 6 (H 2 O) 6 node of this MOF undergoes a 1H + /1e − redox reaction. Using chronoamperometry and the Cottrell analysis, we have determined that the PCET hopping kinetics within the pores of Ce-MOF-808 can change by orders of magnitude by altering the buffer species and the proton activity of the electrolyte. Furthermore, in all buffers, reductive reactions were ∼3−10 times faster in kinetics than the reverse oxidative reaction with the same electrochemical driving force, suggesting that the system, at first glance, violates the principle of microscopic reversibility. Isothermal titration calorimetry (ITC) and computational simulations corroborated that the buffer-node binding thermodynamics are quite distinct, depending on the chemical nature of the buffer and the oxidation state of the node. Together, these results suggest that the substrate and the product during the oxidative vs reductive reaction of Ce-MOF-808 are chemically different species, which explains the apparent ‘microscopic irreversibility.’ Thus, the rational modulation of electrolytes can dramatically enhance PCET kinetics, even though the solid electrodes remain identical. Implications of these findings are contrasted with the electrochemical/electrocatalytic behavior of other redox-active MOFs, heterogeneous catalysts, and enzymatic systems at the solid−liquid interface.

Ce-based MOF↗

Real-Time and Post-Reaction Microscopic Structural Analysis of Biomass Undergoing Pyrolysis

The structural complexity of unprocessed plant tissues used for thermochemical conversion of biomass to fuels and energy impedes heat and mass transfer and may increase the occurrence of tar-forming secondary chemical reactions. At industrial scales, gas and liquid products trapped within large biomass particles may reduce net fuel yields and increase tars, impacting industrial operations and increasing overall costs. Real-time microscopic analysis of poplar (Populus sp.) wood samples undergoing anoxic, pyrolytic heat treatment has revealed a pattern of tissue and macropore expansion and collapse. Post-reaction structural analyses of biomass char (biochar) by light and transmission electron microscopy have provided direct structural evidence of pyrolysis product mass-transfer issues, including trapped pyrolysis products and cell wall compression, and have demonstrated the impact of heat-transfer problems on biomass particles. Finally, microscopic imaging has revealed that pyrolyzed/gasified biochars recovered from a fluidized bed reactor retain a similar pre-reaction basic plant tissue structure as the samples used in this study, suggesting that the phenomena observed here are representative of those that occur in larger scale reactors.

BASIC BIOLOGICAL SCIENCES,BIOMASS FUELS↗

Damage-free vibrational spectroscopy of biological materials in the electron microscope

Vibrational spectroscopy in the electron microscope would be transformative in the study of biological samples, provided that radiation damage could be prevented. However, electron beams typically create high-energy excitations that severely accelerate sample degradation. Here this major difficulty is overcome using an ‘aloof’ electron beam, positioned tens of nanometres away from the sample: high-energy excitations are suppressed, while vibrational modes of energies o1 eV can be ‘safely’ investigated. To demonstrate the potential of aloof spectroscopy, we record electron energy loss spectra from biogenic guanine crystals in their native state, resolving their characteristic C–H, N–H and C=O vibrational signatures with no observable radiation damage. Furthermore, the technique opens up the possibility of non-damaging compositional analyses of organic functional groups, including non-crystalline biological materials, at a spatial resolution of ~10nm, simultaneously combined with imaging in the electron microscope.

59 BASIC BIOLOGICAL SCIENCES↗

Machine learning the microscopic form of nematic order in twisted double-bilayer graphene

Modern scanning probe techniques, such as scanning tunneling microscopy, provide access to a large amount of data encoding the underlying physics of quantum matter. In this work, we show how convolutional neural networks can be used to learn effective theoretical models from scanning tunneling microscopy data on correlated moiré superlattices. Moiré systems are particularly well suited for this task as their increased lattice constant provides access to intra-unit-cell physics, while their tunability allows for the collection of high-dimensional data sets from a single sample. Using electronic nematic order in twisted double-bilayer graphene as an example, we show that incorporating correlations between the local density of states at different energies allows convolutional neural networks not only to learn the microscopic nematic order parameter, but also to distinguish it from heterostrain. These results demonstrate that neural networks are a powerful method for investigating the microscopic details of correlated phenomena in moiré systems and beyond.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microscopic theory, analysis, and interpretation of conductance histograms in molecular junctions

Molecular electronics break-junction experiments are widely used to investigate fundamental physics and chemistry at the nanoscale. Reproducibility in these experiments relies on measuring conductance on thousands of freshly formed molecular junctions, yielding a broad histogram of conductance events. Experiments typically focus on the most probable conductance, while the information content of the conductance histogram has remained unclear. Here we develop a microscopic theory for the conductance histogram by merging the theory of force-spectroscopy with molecular conductance. The procedure yields analytical equations that accurately fit the conductance histogram of a wide range of molecular junctions and augments the information content that can be extracted from them. Our formulation captures contributions to the conductance dispersion due to conductance changes during the mechanical elongation inherent to the experiments. In turn, the histogram shape is determined by the non-equilibrium stochastic features of junction rupture and formation. The microscopic parameters in the theory capture the junction’s electromechanical properties and can be isolated from separate conductance and rupture force (or junction-lifetime) measurements. The predicted behavior can be used to test the range of validity of the theory, understand the conductance histograms, design molecular junction experiments with enhanced resolution and molecular devices with more reproducible conductance properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlating activities and defects in (photo)electrocatalysts using in-situ multi-modal microscopic imaging

Photo(electro)catalysts use sunlight to drive chemical reactions such as water splitting. A major factor limiting photocatalyst development is physicochemical heterogeneity which leads to spatially dependent reactivity. To link structure and function in such systems, simultaneous probing of the electrochemical environment at microscopic length scales and a broad range of timescales (ns to s) is required. Here, we address this challenge by developing and applying in- situ (optical) microscopies to map and correlate local electrochemical activity, with hole lifetimes, oxygen vacancy concentrations and photoelectrode crystal structure. Using this multi-modal approach, we study prototypical hematite (α-Fe 2 O 3 ) photoelectrodes. We demonstrate that regions of α-Fe 2 O 3 , adjacent to microstructural cracks have a better photoelectrochemical response and reduced back electron recombination due to an optimal oxygen vacancy concentration, with the film thickness and extended light exposure also influencing local activity. Our work highlights the importance of microscopic mapping to understand activity, in even seemingly homogeneous photoelectrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extreme ultraviolet microscope characterization using photomask surface roughness

We demonstrate a method for characterizing the field-dependent aberrations of a full-field synchrotron-based extreme ultraviolet microscope. The statistical uniformity of the inherent, atomic-scale roughness of readily-available photomask blanks enables a self-calibrating computational procedure using images acquired under standard operation. We characterize the aberrations across a 30-um field-of-view, demonstrating a minimum aberration magnitude of smaller than λ/21 rms averaged over the center 5-um area, with a measurement accuracy better than λ/180 rms. The measured field variation of aberrations is consistent with system geometry and agrees with prior characterizations of the same system. In certain cases, it may be possible to additionally recover the illumination wavefront from the same images. Our method is general and is easily applied to coherent imaging systems with steerable illumination without requiring invasive hardware or custom test objects; hence, it provides substantial benefits when characterizing microscopes and high-resolution imaging systems in situ.

47 OTHER INSTRUMENTATION↗

Reducing experimental uncertainty in the calculation of cavity swelling in a transmission electron microscope through crystallographically aided void volume tracking

Accurate measurement of cavity swelling in a transmission electron microscope is essential to define material performance under irradiation, and the conventionally applied spherical assumption for the calculation of cavity volumes in irradiated materials can result in errors ranging between a 25% underestimation and 72% overestimation of volume purely based on the assumption of shape. This assumption is undeniably expedient for calculation but does not sufficiently account for the 3D nature of polyhedral cavities and their shape projection in the transmission electron microscope, and therefore presents too large of an associated uncertainty in swelling determination for faceted cavities. This uncertainty has been defined for many common cavity shapes in FCC and BCC crystal systems, and has been tabulated across the cubic fundamental region. A revised methodology for crystallographically aided void volume tracking, or CAVV-T, is presented and demonstrated on a specimen of neutron irradiated Ni. In-depth discussion on the application of this technique is provided along with resources to allow for conversion between the spherical assumption and this revised method. This work seeks to increase experimental confidence in the characterization and quantification of critical aspects of irradiation damage in materials by applying a crystallographically-resolved approach for cavity swelling calculation.

Haag IV, James V. [Pacific Northwest National Labo↗

Unsupervised data mining in nanoscale x-ray spectro-microscopic study of NdFeB magnet

Novel developments in X-ray based spectro-microscopic characterization techniques have increased the rate of acquisition of spatially resolved spectroscopic data by several orders of magnitude over what was possible a few years ago. This accelerated data acquisition, with high spatial resolution at nanoscale and sensitivity to subtle differences in chemistry and atomic structure, provides a unique opportunity to investigate hierarchically complex and structurally heterogeneous systems found in functional devices and materials systems. However, handling and analyzing the large volume data generated poses significant challenges. Here we apply an unsupervised data-mining algorithm known as DBSCAN to study a rare-earth element based permanent magnet material, Nd 2 Fe 14 B. We are able to reduce a large spectro-microscopic dataset of over 300,000 spectra to 3, preserving much of the underlying information. Scientists can easily and quickly analyze in detail three characteristic spectra. Our approach can rapidly provide a concise representation of a large and complex dataset to materials scientists and chemists. For instance, it shows that the surface of common Nd 2 Fe 14 B magnet is chemically and structurally very different from the bulk, suggesting a possible surface alteration effect possibly due to the corrosion, which could affect the material’s overall properties.

36 MATERIALS SCIENCE↗

Microscopic Theory of Fission

In recent years, the microscopic method has been applied to the notoriously difficult problem of nuclear fission with unprecedented success. In this paper, we discuss some of the achievements and promise of the microscopic method, as embodied in the Hartree-Fock method using the Gogny finite-range effective interaction, and beyond-mean-field extensions to the theory. The nascent program to describe induced fission observables using this approach at the Lawrence Livermore National Laboratory is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Drip-line To Drip-line Microscopic Nuclear Level Densities

New energy-, spin- and parity-dependent nuclear level densities based on the microscopic combinatorial model are proposed for practical applications. The combinatorial model includes a detailed microscopic calculation of the intrinsic state density and of the rotational enhancement factor, but a phenomenological treatment of the vibrational effect. The vibrational description has been improved using a boson partition function to construct phonons' state densities which are then folded in with the incoherent particle-hole densities. The present model is shown to predict the experimental s-wave neutron resonance spacings with a degree of accuracy comparable to that of the best global models available.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of an ion beam alignment system for real-time scanning tunneling microscope observation of dopant-ion irradiation

An ion beam alignment system has been developed in order to realize real-time scanning tunneling microscope (STM) observation of 'dopant-ion' irradiation that has been difficult due to the low emission intensity of the liquid-metal-ion-source (LMIS) containing dopant atoms. The alignment system is installed in our original ion gun and STM combined system (IG/STM) which is used for in situ STM observation during ion irradiation. By using an absorbed electron image unit and a dummy sample, ion beam alignment operation is drastically simplified and accurized. We demonstrate that sequential STM images during phosphorus-ion irradiation are successfully obtained for sample surfaces of Si(111)-7x7 at room temperature and a high temperature of 500 deg. C. The LMIS-IG/STM equipped with the developed ion beam alignment system would be a powerful tool for microscopic investigation of the dynamic processes of ion irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microscopic solitons in correlated electronic systems: theory versus experiment

Symmetry broken electronic states give rise to topological defects: from extended domain walls - 'stripes' as solitonic lattices to microscopic solitons as anomalous quasi-particles and instantons in their dynamics. We shall collect and interpret experimental evidences on existence of microscopic solitons, and their determining role in electronic processes of quasi-1D electronic crystals. Thus, the ferroelectric charge ordering in organic conductors gives access to several types of solitons observed in conductivity (holons) and in permittivity (polar kinks), to solitons' bound pairs in optics, to compound charge-spin solitons. In charge density waves, the individual phase solitons have been visually captured in recent STM experiments. The resolved subgap tunneling spectra recover these solitons (in aggregated form of dislocations in statics and as instantons - the phase slips in dynamics), as well as the amplitude kinks - the spinons.The theory relies upon the regime of quantum dissipation provided by soft mode emittance in the course of the soliton creation, and on effects of dimensional crossover. With onset of a 2D or a 3D long range order, the topologically nontrivial solitons experience the confinement resulting in the spin-charge recombination. It originates the symmetry broken spin-or charge- roton configurations with charge- or spin- kinks localized in the core, correspondingly for cases of repulsion and attraction. These complex excitations can be viewed as nucleuses of the melted stripe phases, which appears in doped antiferromagnetic-Mott insulators or in spin-polarized superconductors and charge density waves.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗