Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations

Purpose: The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a linear accelerator.Methods: In order to properly characterize beams from the integrated kV CBCT system, the authors have adapted a previously developed equivalent source model consisting of an equivalent spectrum module that takes into account intrinsic filtration and an equivalent filter module characterizing the added bowtie filtration. An equivalent spectrum was generated for an 80, 100, and 125 kVp beam with beam energy characterized by half-value layer measurements. An equivalent filter description was generated from bowtie profile measurements for both the full- and half-bowtie. Equivalent source models for each combination of equivalent spectrum and filter were incorporated into the Monte Carlo software package MCNPX. Monte Carlo simulations were then validated against in-phantom measurements for both the radiographic and CBCT mode of operation of the kV CBCT system. Radiographic and CBCT imaging dose was measured for a variety of protocols at various locations within a body (32 cm in diameter) and head (16 cm in diameter) CTDI phantom. The in-phantom radiographic and CBCT dose was simulated at all measurement locations and converted to absolute dose using normalization factors calculated from air scan measurements and corresponding simulations. The simulated results were compared with the physical measurements and their discrepancies were assessed quantitatively.Results: Strong agreement was observed between in-phantom simulations and measurements. For the radiographic protocols, simulations uniformly underestimated measurements by 0.54%–5.14% (mean difference =−3.07%, SD = 1.60%). For the CBCT protocols, simulations uniformly underestimated measurements by 1.35%–5.31% (mean difference =−3.42%, SD = 1.09%).Conclusions: This work demonstrates the feasibility of using a measurement-based kV CBCT source model to facilitate dose calculations with Monte Carlo methods for both the radiographic and CBCT mode of operation. While this initial work validates simulations against measurements for simple geometries, future work will involve utilizing the source model to investigate kV CBCT dosimetry with more complex anthropomorphic phantoms and patient specific models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Teleportation of a two-qubit arbitrary unknown state using a four-qubit genuine entangled state with the combination of bell-state measurements

We propose a protocol transferring an arbitrary unknown two-qubit state using the quantum channel of a four-qubit genuine entangled state. Simplifying the four-qubit joint measurement to the combination of Bell-state measurements, it can be realized more easily with currently available technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of a Geochemically Informed Leak Detection (GILD) Model to CO 2 Injection Sites on the United States Gulf Coast

The Gulf Coast region possesses great potential for CO 2 enhanced oil recovery (EOR) and CO 2 storage. A geochemically informed leak detection (GILD) model has been applied to CO 2 injection sites on the Gulf Coast with considerations of measurement variability. The Jasper aquifer in Montgomery County, Texas, was chosen to demonstrate the method. Based on background data from wells in the area, combinations of mineral and fluid compositions were used to create 23 scenarios for the geochemical model. The output from the geochemical model was used to identify sensitive monitoring species, and response functions were generated for these as a function of the CO 2 leakage concentration. The sources of measurement variability for background conditions were characterized from the Jasper aquifer background data, and then normalized using the coefficient of variation of each species across the monitoring wells. Bayesian belief network (BBN) models were constructed, and measurement variability of different levels were added to compare leak detection probabilities. Increasing measurement variability decreased the power to detect a leak of a given size. For a moderately high CO 2 concentration of 0.2 mol/kg, the probability of detecting this leakage effect using pH as the monitoring variable in an aquifer with calcite decreases from 98% (no measurement variability) to 61% (medium variability) to 33% (high variability). The loss in power of the sampling protocol with increasing measurement variability is similar in magnitude when Ca 2+ or HCO 3 - is used as the monitoring parameter, but only for aquifers with calcite.

58 GEOSCIENCES↗

Absolute x-ray dosimetry on a synchrotron medical beam line with a graphite calorimeter

Purpose: The absolute dose rate of the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter. The calorimetry results were compared to measurements from the existing free-air chamber, to provide a robust determination of the absolute dose in the synchrotron beam and provide confidence in the first implementation of a graphite calorimeter on a synchrotron medical beam line. Methods: The graphite calorimeter has a core which rises in temperature when irradiated by the beam. A collimated x-ray beam from the synchrotron with well-defined edges was used to partially irradiate the core. Two filtration sets were used, one corresponding to an average beam energy of about 80 keV, with dose rate about 50 Gy/s, and the second filtration set corresponding to average beam energy of 90 keV, with dose rate about 20 Gy/s. The temperature rise from this beam was measured by a calibrated thermistor embedded in the core which was then converted to absorbed dose to graphite by multiplying the rise in temperature by the specific heat capacity for graphite and the ratio of cross-sectional areas of the core and beam. Conversion of the measured absorbed dose to graphite to absorbed dose to water was achieved using Monte Carlo calculations with the EGSnrc code. The air kerma measurements from the free-air chamber were converted to absorbed dose to water using the AAPM TG-61 protocol. Results: Absolute measurements of the IMBL dose rate were made using the graphite calorimeter and compared to measurements with the free-air chamber. The measurements were at three different depths in graphite and two different filtrations. The calorimetry measurements at depths in graphite show agreement within 1% with free-air chamber measurements, when converted to absorbed dose to water. The calorimetry at the surface and free-air chamber results show agreement of order 3% when converted to absorbed dose to water. The combined standard uncertainty is 3.9%. Conclusions: The good agreement of the graphite calorimeter and free-air chamber results indicates that both devices are performing as expected. Further investigations at higher dose rates than 50 Gy/s are planned. At higher dose rates, recombination effects for the free-air chamber are much higher and expected to lead to much larger uncertainties. Since the graphite calorimeter does not have problems associated with dose rate, it is an appropriate primary standard detector for the synchrotron IMBL x rays and is the more accurate dosimeter for the higher dose rates expected in radiotherapy applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Outcome analysis of individualized vestibular rehabilitation protocols

OBJECTIVE: To determine the outcome of vestibular rehabilitation protocols in subjects with peripheral vestibular disorders compared with normal and abnormal control subjects. STUDY DESIGN: Prospective study using repeated measure, matched control design. Subjects were solicited consecutively according to these criteria: vestibular disorder subjects who had abnormal results of computerized dynamic posturography (CDP) sensory organization tests (SOTs) 5 and 6 and underwent rehabilitation; vestibular disorder subjects who had abnormal results of SOTs 5 and 6 and did not undergo rehabilitation; and normal subjects (normal SOTs). SETTING: Tertiary neurotology clinic. SUBJECTS: Men and women over age 18 with chronic vestibular disorders and chief complaints of unsteadiness, imbalance, and/or motion intolerance, and normal subjects. INTERVENTIONS: Pre- and post-rehabilitation assessment included CDP, vestibular disability, and activities of daily living questionnaires. Individualized rehabilitation plans were designed and implemented to address the subject's specific complaints and functional deficits. Supervised sessions were held at weekly intervals, and self-administered programs were devised for daily home use. MAIN OUTCOME MEASURES: CDP composite and SOT scores, number of falls on CDP, and self-assessment questionnaire results. RESULTS: Subjects who underwent rehabilitation (Group A) showed statistically significant improvements in SOTs, overall composite score, and reduction in falls compared with abnormal (Group B) control groups. Group A's performances after rehabilitation were not significantly different from those of normal subjects (Group C) in SOTs 3 through 6, and close to normal on SOTs 1 and 2. Subjects in Group A also reported statistically significant symptomatic improvement. CONCLUSIONS: Outcome measures of vestibular protocol physical therapy confirmed objective and subjective improvement in subjects with chronic peripheral vestibular disorders. These findings support results reported by other investigators.

NASA Discipline Neuroscience↗

Cooperative Research and Development Agreement between National Energy Technology Laboratory and Gas Technology Institute (Abstract)

Hydrogen has the potential to play an important role in decarbonizing energy-intensive sectors, and credible and open-source protocols are needed to vet the environmental credibility of a specific production pathway, given the variability even among the same technologies. Stakeholders and markets lack consistent, transparent, technical tools and protocols to assess the carbon intensity of hydrogen production at the asset level. Gas Technology Institute (GTI) and S&P Global Platts have launched the Open Hydrogen Initiative (OHI), a new collaboration focused on brining industry within the hydrogen marketplace together to provide further transparency into the environmental greenhouse gas (GHG) impact of hydrogen production. As part of this initiative, GTI has invited NETL to participate in the effort because of NETL’s deep expertise and capabilities in Life Cycle Analysis. Therefore, NETL is joining forces with the Gas Technology Institute (GTI) to build a measurement tool, accompanying protocols, and confidence score of the quality of the measurement. This CRADA effort provides the technical research collaboration support with GTI that will be used in the broader Open Hydrogen Initiative that can provide stakeholders the technical tools and protocols to decarbonize energyintensive sectors.

08 HYDROGEN↗

Editors’ Choice—Rapid Deactivation Convolutes Electrochemical CO 2 Reduction Selectivity Measurements on Gold Rotating Ring Disk Electrodes

Voltammetric measurements of electrochemical CO 2 reduction reaction (CO 2 RR) selectivity on rotating ring disk electrodes (RRDE) are a rapid and sensitive method for quantifying an electrocatalyst’s selectivity, i.e. faradaic efficiency (FE). This method has been applied to polycrystalline Au electrocatalysts where a Au disk electrode catalyzes both the CO 2 RR and hydrogen evolution reaction while the concentric Au ring electrode selectively senses CO by oxidizing CO back to CO 2 . Such measurements enabled fundamental mechanistic studies but suffer from poor inter-laboratory reproducibility. This work identifies causes of variability in RRDE selectivity measurements by comparing protocols with different electrochemical methods, reagent purities, and glassware cleaning procedures. We observed FE CO decrease by 56% during 5 min chronoamperometry measurements, a phenomenon that is not readily apparent in voltammetric scans due to their dynamic nature. Electroplating of electrolyte impurities onto the disk and ring surfaces were identified as a major contributor to Au deactivation. Additionally, the oxygen reduction reaction may lead to higher disk currents in inadequately purged electrolytes, causing an apparent underestimation of FE CO at low overpotentials. Lastly, we propose operational bounds for CO 2 RR selectivity measurements on Au using the RRDE method and provide suggestions on steps for improving the accuracy of this technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Elastic wave velocity measurement using ultrasonic system with two-reflectors

We show an experiment protocol for ultrasonic velocity measurements carried out in a synchrotron-based multi-anvil high-pressure apparatus. By adding a second reflector in the cell assembly, ultrasonic signals are significantly stabilized for experiments where samples experience structural changes such as phase transition or partial melting. Features of the elastic wave can be calculated from acoustic impedance allowing us to evaluate the possible interference between the sample reflection and other internal multiple reflections. This new protocol allows various forms of samples including cold-pressed powder samples, for which grain size and porosity can be monitored and controlled in situ during the annealing process.

47 OTHER INSTRUMENTATION↗

Computer simulation of fibrillation threshold measurements and electrophysiologic testing procedures

A finite element model of cardiac conduction was used to simulate two experimental protocols: 1) fibrillation threshold measurements and 2) clinical electrophysiologic (EP) testing procedures. The model consisted of a cylindrical lattice whose properties were determined by four parameters: element length, conduction velocity, mean refractory period, and standard deviation of refractory periods. Different stimulation patterns were applied to the lattice under a given set of lattice parameter values and the response of the model was observed through a simulated electrocardiogram. The studies confirm that the model can account for observations made in experimental fibrillation threshold measurements and in clinical EP testing protocols.

NASA Discipline Cardiopulmonary↗

Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

This Commercial and Industrial Lighting Controls Evaluation Protocol (the protocol) describes methods to account for energy savings resulting from programmatic installation of lighting control equipment in large populations of commercial, industrial, government, institutional, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. When lighting controls are installed in conjunction with a lighting retrofit project, the lighting control savings must be calculated parametrically with the lighting retrofit project so savings are not double counted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Round Robin Test on Enthalpies of Redox Materials for Thermochemical Heat Storage: Perovskites

Among the potential materials proposed as suitable for thermochemical heat storage, ABO3 perovskites merit significant attention for high temperature applications in concentrating solar power plants. The specific enthalpy of the reaction is a key parameter to establish the storage capacity of the system, and accordingly determines the potential impact on decreasing related costs associated with the volume of the system. Discrepancies in the referenced enthalpies may arise from different sources like the experimental sets-ups for measuring thermodynamic properties; protocols applied or the origin of the samples. This work presents a round robin test conducted by seven institutions in order to establish a standard methodology for the measurement of enthalpies of relevant thermochemical processes at high temperature. The initiative was organized within the Working Group on Thermal Storage (Activity on 'Materials for Thermal Storage') in SolarPACES Task III.

14 SOLAR ENERGY↗

Characterization and effects of impurities on carbonate quantification in heterogenous matrices

Mineral carbonation simulates a natural weathering phenomena by breaking down silicates and oxides to form Ca & Mg carbonates. Various mineralization methods have been demonstrated as a potential technique to improve the quality of slags and tailings through neutralization and stabilization of problematic species to yield a product better suited for use in concrete. This study aims to characterize, quantify and analyze carbonates in various carbonated products such as mineralized CaCO 3 , CO 2 mineralized Steel Slags and Mine Tailings. More than 10 samples were analyzed for carbonate measurement and verification from industrial and academic partners that pioneer commercial CO 2 mineralization technologies. The samples were characterized primarily by using X-ray diffraction (XRD), Thermogravimetric Analyses (TGA), and Scanning Electron Microscopy (SEM) to gain insights into CaCO 3 content. A baseline characterization of lab-grade CaCO 3 and MgCO 3 also revealed important considerations for CaCO 3 measurement using TGA alone. The experiments using synthetic lab-grade samples also revealed that the presence of MgCO 3 /MgO can accelerate the decomposition of CaCO 3 and thus can affect measurement parameters. Lab-grade CaCO 3 samples dosed into steel slag and mine tailing also showed significant deviation in their decomposition behavior. These insights are used to inform the development of a standardized protocol for the measurement and verification of carbonate-bearing products.

97 MATHEMATICS AND COMPUTING↗

SeaWiFS technical report series. Volume 5: Ocean optics protocols for SeaWiFS validation

Protocols are presented for measuring optical properties, and other environmental variables, to validate the radiometric performance of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS), and to develop and validate bio-optical algorithms for use with SeaWiFS data. The protocols are intended to establish foundations for a measurement strategy to verify the challenging SeaWiFS accuracy goals of 5 percent in water-leaving radiances and 35 percent in chlorophyll alpha concentration. The protocols first specify the variables which must be measured, and briefly review rationale. Subsequent chapters cover detailed protocols for instrument performance specifications, characterizing and calibration instruments, methods of making measurements in the field, and methods of data analysis. These protocols were developed at a workshop sponsored by the SeaWiFS Project Office (SPO) and held at the Naval Postgraduate School in Monterey, California (9-12 April, 1991). This report is the proceedings of that workshop, as interpreted and expanded by the authors and reviewed by workshop participants and other members of the bio-optical research community. The protocols are a first prescription to approach unprecedented measurement accuracies implied by the SeaWiFS goals, and research and development are needed to improve the state-of-the-art in specific areas. The protocols should be periodically revised to reflect technical advances during the SeaWiFS Project cycle.

Mueller, James L.↗

Fidelity-optimized quantum state estimation

We describe an optimized, self-correcting procedure for the Bayesian inference of pure quantum states. By analyzing the history of measurement outcomes at each step, the procedure returns the most likely pure state, as well as the optimal basis for the measurement that is to follow. The latter is chosen to maximize, on average, the fidelity of the most likely state after the measurement. We also consider a practical variant of this protocol, where the available measurement bases are restricted to certain limited sets of bases. We demonstrate the success of our method by considering in detail the single-qubit and two-qubit cases, and comparing the performance of our method against other existing methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Linearization of dose-response curve of the radiochromic film dosimetry system

Purpose: Despite numerous advantages of radiochromic film dosimeter (high spatial resolution, near tissue equivalence, low energy dependence) to measure a relative dose distribution with film, one needs to first measure an absolute dose (following previously established reference dosimetry protocol) and then convert measured absolute dose values into relative doses. In this work, we present result of our efforts to obtain a functional form that would linearize the inherently nonlinear dose-response curve of the radiochromic film dosimetry system. Methods: Functional form [{zeta}= (-1){center_dot}netOD{sup (2/3)}/ln(netOD)] was derived from calibration curves of various previously established radiochromic film dosimetry systems. In order to test the invariance of the proposed functional form with respect to the film model used we tested it with three different GAFCHROMIC Trade-Mark-Sign film models (EBT, EBT2, and EBT3) irradiated to various doses and scanned on a same scanner. For one of the film models (EBT2), we tested the invariance of the functional form to the scanner model used by scanning irradiated film pieces with three different flatbed scanner models (Epson V700, 1680, and 10000XL). To test our hypothesis that the proposed functional argument linearizes the response of the radiochromic film dosimetry system, verification tests have been performed in clinical applications: percent depth dose measurements, IMRT quality assurance (QA), and brachytherapy QA. Results: Obtained R{sup 2} values indicate that the choice of the functional form of the new argument appropriately linearizes the dose response of the radiochromic film dosimetry system we used. The linear behavior was insensitive to both film model and flatbed scanner model used. Measured PDD values using the green channel response of the GAFCHROMIC Trade-Mark-Sign EBT3 film model are well within {+-}2% window of the local relative dose value when compared to the tabulated Cobalt-60 data. It was also found that criteria of 3%/3 mm for an IMRT QA plan and 3%/2 mm for a brachytherapy QA plan are passing 95% gamma function points. Conclusions: In this paper, we demonstrate the use of functional argument to linearize the inherently nonlinear response of a radiochromic film based reference dosimetry system. In this way, relative dosimetry can be conveniently performed using radiochromic film dosimetry system without the need of establishing calibration curve.

60 APPLIED LIFE SCIENCES↗

Detailed high-accuracy megavoltage transmission measurements: A sensitive experimental benchmark of EGSnrc

Purpose: There are three goals for this study: (a) to perform detailed megavoltage transmission measurements in order to identify the factors that affect the measurement accuracy, (b) to use the measured data as a benchmark for the EGSnrc system in order to identify the computational limiting factors, and (c) to provide data for others to benchmark Monte Carlo codes. Methods: Transmission measurements are performed at the National Research Council Canada on a research linac whose incident electron parameters are independently known. Automated transmission measurements are made on-axis, down to a transmission value of {approx}1.7%, for eight beams between 10 MV (the lowest stable MV beam on the linac) and 30 MV, using fully stopping Be, Al, and Pb bremsstrahlung targets and no fattening filters. To diversify energy differentiation, data are acquired for each beam using low-Z and high-Z attenuators (C and Pb) and Farmer chambers with low-Z and high-Z buildup caps. Experimental corrections are applied for beam drifts (2%), polarity (2.5% typical maximum, 6% extreme), ion recombination (0.2%), leakage (0.3%), and room scatter (0.8%)-the values in parentheses are the largest corrections applied. The experimental setup and the detectors are modeled using EGSnrc, with the newly added photonuclear attenuation included (up to a 5.6% effect). A detailed sensitivity analysis is carried out for the measured and calculated transmission data. Results: The developed experimental protocol allows for transmission measurements with 0.4% uncertainty on the smallest signals. Suggestions for accurate transmission measurements are provided. Measurements and EGSnrc calculations agree typically within 0.2% for the sensitivity of the transmission values to the detector details, to the bremsstrahlung target material, and to the incident electron energy. Direct comparison of the measured and calculated transmission data shows agreement better than 2% for C (3.4% for the 10 MV beam) and typically better than 1% for Pb. The differences can be explained by acceptable photon cross section changes of Less-Than-Or-Slanted-Equal-To 0.4%. Conclusions: Accurate transmission measurements require accounting for a number of influence quantities which, if ignored, can collectively introduce errors larger than 10%. Accurate transmission calculations require the use of the most accurate data and physics options available in EGSnrc, particularly the more accurate bremsstrahlung angular sampling option and the newly added modeling of photonuclear attenuation. Comparison between measurements and calculations implies that EGSnrc is accurate within 0.2% for relative ion chamber response calculations. Photon cross section uncertainties are the ultimate limiting factor for the accuracy of the calculated transmission data (Monte Carlo or analytical).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Dynamic Assimilation Technique measures photosynthetic CO2 response curves with similar fidelity as steady-state approaches in half the time

The net CO2 assimilation (A) response to intercellular CO2 concentration (Ci) is a fundamental measurement in photosynthesis and plant physiology research. The conventional A/Ci protocols rely on steady-state measurements and take 15-40 minute per measurement, limiting data resolution or biological replication. Additionally, there are several CO2 protocols employed across the literature, without clear consensus as to the optimal protocol or systematic biases in their estimations. We compared the non-steady state Dynamic Assimilation Technique (DAT) protocol and the three most used CO2 protocols in steady-state measurements, and tested whether different CO2 protocols lead to systematic differences in estimations of the biochemical limitations to photosynthesis.

A/Ci response↗

When a quantum measurement can be implemented locally, and when it cannot

In the absence of quantum channels, local operations on subsystems and classical communication between parties (LOCC) constitute the most general protocols available on spatially separated quantum systems. Every LOCC protocol implements a separable quantum measurement, but it is known that there exist separable measurements that cannot be implemented by LOCC. A longstanding problem in quantum information theory is to understand the difference between LOCC and the full set of separable measurements. Toward this end, we show in this paper how to construct an LOCC protocol to implement an arbitrary separable measurement whenever such a protocol exists. In addition, given a measurement that cannot be implemented by LOCC within some fixed maximum number of rounds, the method shows explicitly that this is the case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗