Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Nonlinear effects in the time measurement device based on surface acoustic wave filter excitation

A transversal surface acoustic wave filter has been used as a time interpolator in a time interval measurement device. We are presenting the experiments and results of an analysis of the nonlinear effects in such a time interpolator. The analysis shows that the nonlinear distortion in the time interpolator circuits causes a deterministic measurement error which can be understood as the time interpolation nonlinearity. The dependence of this error on time of the measured events can be expressed as a sparse Fourier series thus it usually oscillates very quickly in comparison to the clock period. The theoretical model is in good agreement with experiments carried out on an experimental two-channel timing system. Using highly linear amplifiers in the time interpolator and adjusting the filter excitation level to the optimum, we have achieved the interpolation nonlinearity below 0.2 ps. The overall single-shot precision of the experimental timing device is 0.9 ps rms in each channel.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Carbon monoxide measurement in the global atmospheric sampling program

The carbon monoxide measurement system used in the NASA Global Atmospheric Sampling Program (GASP) is described. The system used a modified version of a commercially available infrared absorption analyzer. The modifications increased the sensitivity of the analyzer to 1 ppmv full scale, with a limit of detectability of 0.02 ppmv. Packaging was modified for automatic, unattended operation in an aircraft environment. The GASP system is described along with analyzer operation, calibration procedures, and measurement errors. Uncertainty of the CO measurement over a 2-year period ranged from + or - 3 to + or - 13 percent of reading, plus an error due to random fluctuation of the output signal + or - 3 to + or - 15 ppbv.

Dudzinski, T. J.↗

On the Accurate Calibration of the SeaWinds Radar Antenna: A Cylindrical Near-Field Measurement Approach

The radar antenna for the SeaWinds scatterometer will be of the multipolarized, multi- incidence angle, conical scanning design. It will measure echos from the sea surface to derive both the speed and direction of winds. To calibrate this radar, measurement error models are used to define the effects of near-field measurement bias errors on antenna gain and far-field radiation patterns.

SeaWinds↗

Submilliarcsecond VLBI Using Compact Close Pairs of Radio Sources: Error Analysis

The potential accuracy attainable for (delta) VLBI positional measurements (submilliarc second level) is reached by simultaneously observing pairs of compact radio sources whose angular separation are smaller than the beamwidth of each antenna. Simultaneous (delta) VLBI (SVLBI) enables significant cancellation of measurement errors. Solar plasma is the dominant fluctuating error source in SVLBI positional measurements since there is enhanced cancellation of the troposphere and ionosphere, and complete cancellation of oscillator instabilities. Of the nonfluctuating error sources, errors due to universal time predominate. By performing SVLBI experiments over several years with many different close pairs of radio sources, limits can be placed on reference frame stability. Intrinsic properties of the sources, such as source structure and proper motion, will limit measurements. The SVLBI differential phase and corruptive noise sources will be discussed here along with estimated results.

Morabito, D. D.↗

Occupancy prediction through machine learning and data fusion of environmental sensing and Wi-Fi sensing in buildings

Occupancy information is crucial to building facility design, operation, and energy efficiency. Many studies propose the use of environmental sensors (such as carbon dioxide, air temperature, and relative humidity sensors) and radio-frequency sensors (Wi-Fi networks) to monitor, assess, and predict occupancy information for buildings. As many methods have been developed and a variety of sensory data sources are available, establishing a proper selection of model and data source is critical to the successful implementation of occupancy prediction systems. This study compared three popular machine learning algorithms, including k-nearest neighbors (kNN), support vector machine (SVM), and artificial neural network (ANN), combined with three data sources, including environmental data, Wi-Fi data, and fused data, to optimize the occupancy models’ performance in various scenarios. Three error measurement metrics, the mean average error (MAE), mean average percentage error (MAPE), and root mean squared error (RMSE), have been employed to compare the models’ accuracies. Examined with an on-site experiment, the results suggest that the ANN-based model with fused data has the best performance, while the SVM model is more suitable with Wi-Fi data. The results also indicate that, comparing with independent data sources, the fused data set does not necessarily improve model accuracy but shows a better robustness for occupancy prediction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Morse–Smale Regression

This paper introduces a novel partition-based regression approach that incorporates topological information. Partition-based regression typically introduces a quality-of-fit-driven decomposition of the domain. The emphasis in this work is on a topologically meaningful segmentation. Thus, the proposed regression approach is based on a segmentation induced by a discrete approximation of the Morse–Smale complex. This yields a segmentation with partitions corresponding to regions of the function with a single minimum and maximum that are often well approximated by a linear model. This approach yields regression models that are amenable to interpretation and have good predictive capacity. Typically, regression estimates are quantified by their geometrical accuracy. For the proposed regression, an important aspect is the quality of the segmentation itself. Thus, this article introduces a new criterion that measures the topological accuracy of the estimate. The topological accuracy provides a complementary measure to the classical geometrical error measures and is very sensitive to overfitting. The Morse–Smale regression is compared to state-of-the-art approaches in terms of geometry and topology and yields comparable or improved fits in many cases. Finally, a detailed study on climate-simulation data demonstrates the application of the Morse–Smale regression. Supplementary Materials are available online and contain an implementation of the proposed approach in the R package msr, an analysis and simulations on the stability of the Morse–Smale complex approximation, and additional tables for the climate-simulation study.

97 MATHEMATICS AND COMPUTING↗

THE STELLAR VELOCITY DISPERSION OF A COMPACT MASSIVE GALAXY AT z = 1.80 USING X-SHOOTER: CONFIRMATION OF THE EVOLUTION IN THE MASS-SIZE AND MASS-DISPERSION RELATIONS {sup ,}

Recent photometric studies have shown that early-type galaxies at fixed stellar mass were smaller and denser at earlier times. In this Letter, we assess that finding by deriving the dynamical mass of such a compact quiescent galaxy at z = 1.8. We have obtained a high-quality spectrum with full UV-NIR wavelength coverage of galaxy NMBS-C7447 using X-Shooter on the Very Large Telescope. We determined a velocity dispersion of 294 {+-} 51 km s{sup -1}. Given this velocity dispersion and the effective radius of 1.64 {+-} 0.15 kpc (as determined from Hubble Space Telescope Wide Field Camera 3 F160W observations) we derive a dynamical mass of (1.7 {+-} 0.5) x 10{sup 11} M{sub sun}. Comparison of the full spectrum with stellar population synthesis models indicates that NMBS-C774 has a relatively young stellar population (0.40 Gyr) with little or no star formation and a stellar mass of M{sub *} {approx} 1.5 x 10{sup 11} M{sub sun}. The dynamical and photometric stellar masses are in good agreement. Thus, our study supports the conclusion that the mass densities of quiescent galaxies were indeed higher at earlier times, and this earlier result is not caused by systematic measurement errors. By combining available spectroscopic measurements at different redshifts, we find that the velocity dispersion at fixed dynamical mass was a factor of {approx}1.8 higher at z = 1.8 compared with z = 0. Finally, we show that the apparent discrepancies between the few available velocity dispersion measurements at z > 1.5 are consistent with the intrinsic scatter of the mass-size relation.

79 ASTRONOMY AND ASTROPHYSICS↗

Uncertainty in terahertz time-domain spectroscopy measurement

Measurements of optical constants at terahertz--or T-ray--frequencies have been performed extensively using terahertz time-domain spectroscopy (THz-TDS). Spectrometers, together with physical models explaining the interaction between a sample and T-ray radiation, are progressively being developed. Nevertheless, measurement errors in the optical constants, so far, have not been systematically analyzed. This situation calls for a comprehensive analysis of measurement uncertainty in THz-TDS systems. The sources of error existing in a terahertz spectrometer and throughout the parameter estimation process are identified. The analysis herein quantifies the impact of each source on the output optical constants. The resulting analytical model is evaluated against experimental THz-TDS data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mitigating the noise of DESI mocks using analytic control variates

In order to address fundamental questions related to the expansion history of the Universe and its primordial nature with the next generation of galaxy experiments, we need to model reliably large-scale structure observables such as the correlation function and the power spectrum. Cosmological N-body simulations provide a reference through which we can test our models, but their output suffers from sample variance on large scales. Fortunately, this is the regime where accurate analytic approximations exist. To reduce the variance, which is key to making optimal use of these simulations, we can leverage the accuracy and precision of such analytic descriptions using Control Variates (CV). The power of control variates stems from utilizing inexpensive but highly correlated surrogates of the statistics one wishes to measure. The stronger the correlation between the surrogate and the statistic of interest, the larger the variance reduction delivered by the method. We apply two control variate formulations to mock catalogs generated in anticipation of upcoming data from the Dark Energy Spectroscopic Instrument (DESI) to test the robustness of its analysis pipeline. Our CV-reduced measurements offer a factor of 5-10 improvement in the measurement error compared with the raw measurements. We explore the relevant properties of the galaxy samples that dictate this reduction and comment on the improvements we find on some of the derived quantities relevant to Baryon Acoustic Oscillation (BAO) analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Lidar measurements of yawed-wind-turbine wakes: characterization and validation of analytical models

Abstract. Wake measurements of a scanning Doppler lidar mounted on the nacelle of a full-scale wind turbine during a wake-steering experiment were used for the characterization of the wake flow, the evaluation of the wake-steering set-up, and the validation of analytical wake models. Inflow-scanning Doppler lidars, a meteorological mast, and the supervisory control and data acquisition (SCADA) system of the wind turbine complemented the set-up. Results from the wake-scanning Doppler lidar showed an increase in the wake deflection with the yaw angle and that the wake deflection was not in all cases beneficial for the power output of a downstream turbine due to a bias of the inflow wind direction perceived by the yawed wind turbine and the wake-steering design implemented. Both observations could be reproduced with an analytical model that was initialized with the inflow measurements. Error propagation from the inflow measurements that were used as model input and the power coefficient of a waked wind turbine contributed significantly to the model uncertainty. Lastly, the span-wise cross section of the wake was strongly affected by wind veer, masking the effects of the yawed wind turbine on the wake cross sections.

17 WIND ENERGY↗

Multipath induced errors in meteorological Doppler/interferometer location systems

One application of an RF interferometer aboard a low-orbiting spacecraft to determine the location of ground-based transmitters is in tracking high-altitude balloons for meteorological studies. A source of error in this application is reflection of the signal from the sea surface. Through propagating and signal analysis, the magnitude of the reflection-induced error in both Doppler frequency measurements and interferometer phase measurements was estimated. The theory of diffuse scattering from random surfaces was applied to obtain the power spectral density of the reflected signal. The processing of the combined direct and reflected signals was then analyzed to find the statistics of the measurement error. It was found that the error varies greatly during the satellite overpass and attains its maximum value at closest approach. The maximum values of interferometer phase error and Doppler frequency error found for the system configuration considered were comparable to thermal noise-induced error.

Wallace, R. G.↗

Astrogam - A magnetic rigidity spectrometer for gamma-ray astronomy

A novel concept is presented for a high-energy gamma-ray telescope with an extended energy range and excellent energy and angular resolution. The characteristics of Astrogam, a wide-field camera which makes an all-sky survey, are enumerated. Consideration is given to the instrument's unique features: wide energy range (four orders of magnitude and energy, which will bridge the gap between satellite and ground-based observations); excellent source location precision (multiple scattering error dominating nuclear recoil and measurement error below 20 GeV); and excellent energy resolution (1-percent energy resolution). Astrogam will make observations in the GTE energy range possible and could resolve complex source regions like the Crab pulsar/Nebular system, the Galactic center, and the Geminga region as well as discover the true nature of the sources.

Adams, James H., Jr.↗

The Double-peaked Radio Light Curve of Supernova PTF11qcj

We present continued radio and X-ray follow-up observations of PTF11qcj, a highly energetic broad-lined Type Ic supernova (SN), with a radio peak luminosity comparable to that of the γ-ray burst (GRB) associated SN 1998bw. The latest radio observations, carried out with the Karl G. Jansky Very Large Array, extend up to ∼5 yr after the PTF11qcj optical discovery. The radio light curve shows a double-peak profile, possibly associated with density variations in the circumstellar medium (CSM), or with the presence of an off-axis GRB jet. Optical spectra of PTF11qcj taken during both peaks of the radio light curve do not show the broad Hα features typically expected from H-rich circumstellar interaction. Modeling of the second radio peak within the CSM-interaction scenario requires a flatter density profile and an enhanced progenitor mass-loss rate compared to those required to model the first peak. Our radio data alone cannot rule out the alternative scenario of an off-axis GRB powering the second radio peak, but the derived GRB parameters are somewhat unusual compared to typical values found for cosmological long GRBs. On the other hand, Chandra X-ray observations carried out during the second radio peak are compatible with the off-axis GRB hypothesis, within the large measurement errors. We conclude that VLBI measurements of the PTF11qcj radio ejecta are needed to unambiguously confirm or rule out the off-axis GRB jet scenario.

Nipuni T Palliyaguru↗

Enhancing the Material Control & Accounting Measurement System at the State Scientific Center of the Russian Federation - Institute for Physics and Power Engineering named after A.I. Leypunsky

Nuclear material control and accounting (NMCA) system is improving under cooperation with USA national laboratories. Standard reference materials (RMs) and measurement techniques certified at IPPE level are required for: instrument calibration, verification measurements of parameters of items and materials, measurement error estimation, and quality control measurements. We present the main results for development of nuclear RMs for two uranium strata and the results for certification of three measurement techniques (MT) for U-235 mass fraction in uranium and U-235 mass in items. We present the results for developing measurement techniques for Pu-239 in PuO{sub 2}.

ACCOUNTING↗

A Dissimilarity Measure for Clustering High- and Infinite Dimensional Data that Satisfies the Triangle Inequality

The cosine or correlation measures of similarity used to cluster high dimensional data are interpreted as projections, and the orthogonal components are used to define a complementary dissimilarity measure to form a similarity-dissimilarity measure pair. Using a geometrical approach, a number of properties of this pair is established. This approach is also extended to general inner-product spaces of any dimension. These properties include the triangle inequality for the defined dissimilarity measure, error estimates for the triangle inequality and bounds on both measures that can be obtained with a few floating-point operations from previously computed values of the measures. The bounds and error estimates for the similarity and dissimilarity measures can be used to reduce the computational complexity of clustering algorithms and enhance their scalability, and the triangle inequality allows the design of clustering algorithms for high dimensional distributed data.

Socolovsky, Eduardo A.↗

Implementation of an Experimental Setup Based on the Three-Omega Method for Thermal Conductivity Measurements of Molten Salts

Molten salt reactors (MSRs) are one of the most promising next-generation nuclear reactor designs which use molten salts as the fuel and coolant. To design, model, predict, license, and operate MSRs, the behavior of the fuel and coolant must be understood as a function of temperature and irradiation, i.e., burnup. Of particular importance and complexity is the reliable and reproducible measurement of thermal conductivity of molten salts at high temperatures (> 500 °C). Thermal conductivity provides information on the rate at which heat passes through a specified material and is dependent on chemical composition. Currently, in the national laboratory complex, several methods for measuring thermal conductivity on molten salt systems are under development, however, to date, consistent data have not been produced. Typically, thermal conductivity measurements of high-temperature melts have been conducted by using the Transient Hot Wire (THW) method where thermal conductivity is determined by the change in temperature over time at a certain distance from a heating wire. Another time-dependent technique is the laser flash method, commonly used for solid samples. Laser flash requires prior measurements of density and heat capacity to calculate the thermal conductivity of the sample, introducing additional measurement errors. Steady state and time-dependent measurements such as THW and laser flash have errors from convection and ambient temperature fluctuations (heat radiation). In order to produce high fidelity thermal conductivity data, a measurement technique needs to be developed that will reduce the effect of convection at high temperatures by measuring in a very fast time window. In addition, to measure on actinide and irradiated salts the sample size should be small. Therefore, this project aims to develop a frequency-domain technique based on the three-omega (3?) method, previously proven to work on solids, nanofluids and low temperature solar salts (25 to 250 °C). If the 3?-device can be designed with materials that can withstand high temperatures (>500 °C) and can be configured to reduce errors due to convection, then it would prove to be a valuable technique for ensuring thermal conductivity on molten salt systems needed for MSR development. For this proposal, the 3? instrument will be designed, assembled, and tested on non-radioactive salts before being used on actinide bearing salts. In addition, a thermal model will be developed to determine the thermal conductivity of the sample from the measured thermal oscillation of the sensor. Because 3? is a direct method that requires a small volume of sample and works in a very fast time window, it will aid in suppressing the interference due to convection which is ideal when working with high temperature liquid samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Benefits of the Multiple Echo Technique for Ultrasonic Thickness Testing

Much effort has been put into determining methods to make accurate thickness measurements, especially at elevated temperatures. An accuracy of +/- 0.001 inches is typically noted for commercial ultrasonic thickness gauges and ultrasonic thickness techniques. Codes and standards put limitations on many inspection factors including equipment, calibration tolerance and temperature variations. These factors are important and should be controlled, but unfortunately do not guarantee accurate and repeatable measurements in the field. Most technicians long for a single technique that is best for every situation, unfortunately, there are no 'silver bullets' when it comes to nondestructive testing. This paper will describe and discuss some of the major contributors to measurement error as well as some advantages and limitations of multiple echo techniques and why multiple echo techniques should be more widely utilized for ultrasonic thickness measurements.

42 ENGINEERING↗

Skylab water balance error analysis

Estimates of the precision of the net water balance were obtained for the entire Skylab preflight and inflight phases as well as for the first two weeks of flight. Quantitative estimates of both total sampling errors and instrumentation errors were obtained. It was shown that measurement error is minimal in comparison to biological variability and little can be gained from improvement in analytical accuracy. In addition, a propagation of error analysis demonstrated that total water balance error could be accounted for almost entirely by the errors associated with body mass changes. Errors due to interaction between terms in the water balance equation (covariances) represented less than 10% of the total error. Overall, the analysis provides evidence that daily measurements of body water changes obtained from the indirect balance technique are reasonable, precise, and relaible. The method is not biased toward net retention or loss.

Leonard, J. I.↗