Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “magnet test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Simulation study of fast ion losses associated with the rotating n = 1 resonant magnetic perturbations in KSTAR

In this work we describe a simulation framework for testing the fast ion loss mechanism associated with the experimentally observed beam ion losses when an externally applied toroidally rotating perturbed magnetic field is used to control edge localized modes in the KSTAR tokamak. The simulations reproduce the key qualitative features of neutral beam injection (NBI) ion detection by a fast ion loss detector. The NBI ion losses in the simulation mainly occur for passing particles due to orbit stochastization, which is caused by orbit resonance with the 3D field perturbations. The relative toroidal angle of NBI ion deposition to the orbit island determines the radial path of the particles between confinement or loss. The fast ion loss quantity depends on the toroidal angle rotation of the 3D field with respect to the beam deposition position. The averaged transport of toroidal canonical angular momentum reveals that linear and nonlinear resonance of the NBI ions within the 3D field are the main factors determining fast ion transport and loss.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Magnetized Electron Source For Ion Beam Cooling

A number of electron-ion collider facilities for nuclear physics research are under consid- eration in the United States. At Brookhaven National Lab (BNL), the eRHIC (electron Relativistic Heavy Ion Collider) facility would augment the existing ion/proton facility with an electron accelerator. Thomas Jefferson National Accelerator Facility (JLab) plans to use the existing CEBAF machine and add an ion/proton accelerator, as part of the Jefferson Lab Electron-Ion Collider (JLEIC). All such facilities require cooling of the ion beams in order to reach the luminosity goals. Different methods of cooling the ions using an electron beam are envisaged. BNL is pursuing coherent electron cooling and non-magnetized, bunched-beam cooling, while JLab is considering magnetized cooling. In addition to electron cooling, magnetized beams are of interest for other applica- tions, such as flat beam klystrons and novel means for producing bright beams for micro- undulators and compact X-ray sources. For example, flat beams generated from a mag- netized injector, in conjunction with low emittance, enable RF sources with frequencies above 100 GHz. While the market for high-performance injectors for electron cooling is limited, the market for high-frequency RF sources and compact X-ray systems is con- siderable. Thus, the design methodologies developed in this project have a wide range of applicability. In Phase I of this SBIR project, Xelera Research LLC performed simulations and calcu- lations to develop a prototype design for a magnetized electron injector that can be used as a source for cooling an ion beam. We developed general design methodologies and tech- niques that are applicable not only to specific machine designs but to other applications requiring magnetized injectors as well. In this Phase II SBIR project, Xelera Research LLC, in collaboration with a team at JLab, designed, built, and tested a thermionic elec- tron source for driving a magnetized electron cooler in a future electron-ion collider project. This device was delivered to JLab in July 2019 and achieved first beam in December 2019.

43 PARTICLE ACCELERATORS↗

Mechanical Design of the Interaction Region Dipole B1pF for Electron Ion Collider

Here, the Electron-Ion Collider (EIC), planned for construction at Brookhaven National Laboratory, will consist of two intersecting beams of intense electrons and high-energy protons or heavier atomic nuclei. The collider will need many demanding components, including high field superconducting magnets for the Interaction Region (IR). It has been decided that a prototype of one such magnet, the B1pF dipole, shall be built, to validate design choices common to all Rutherford cable dipole and quadrupole IR magnets. B1pF is one of several high field magnets in the interaction region whose design is based on the 15.1 mm wide NbTi cable, a cable like the one used in the main dipole coil of the Large Hadron Collider (LHC) at CERN. The current design is based on a single layer coil with an inner diameter of 300 mm and magnetic length of ~3 m which generates a magnetic field at the center of the magnet of about 3.7 T at a current of ~11 kA at design. This paper presents the mechanical design of the B1pF dipole magnet, and the R&D effort associated with the development of the prototype, including tests for successfully winding and curing coils of the needed configuration into proper structural and magnetic elements, and including a multilayer magnetic return yoke which meets field requirements while providing an initial reduced structure suitable for operational testing in an existing test facility.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flex-PCB Quench Antenna Developments at FNAL

We report flexible printed-circuit-board-based quench antenna arrays have been developed at FNAL since 2017. They proved to be low-noise, low-cost, sensitive, and non-invasive sensors for quench characterization in superconducting magnets, having the potential to extend even to quench detection. Starting with applications of small area sensors of this type, we have explored feasibility for operations at high pressure, and have invested in multi-channel quench antenna arrays covering the complete area of the innermost magnet layer of the conductor. We've also tested and optimized sensor geometry and relative orientations to increase sensitivity and spatial resolution. Beyond developments of warm and cold bore antennas, we've progressed to concepts which attach quench antennas to the conductor surfaces of accelerator magnets. Multiple programs and projects at FNAL and collaborating institutions benefited from this work already and our plans target further extensions of capabilities and applicability of these devices. In this paper we present the logic behind the development steps taken so far, status of our work and direction of near-term research on quench antennas at Fermilab.

43 PARTICLE ACCELERATORS↗

An experimental study to investigate magnetic field and winding force-dependent contact resistance of NI REBCO coil

Abstract This paper reports the magnetic field and winding force-dependent contact resistance, also known as characteristic resistance, of no-insulation (NI) REBCO coil. Three NI coils were wound with different winding forces ( < 1 kgf, 3 kgf, and 5 kgf) using the same REBCO-coated conductor, and they were tested at 4.2 K in a background field of 0, 5, 10, and 14 T. The contact resistance of each coil is measured at each field. As a result of the measurements, we draw two conclusions. First, a quadratic function for magnetic field intensity reasonably reproduces the measurement results of each NI test coil’s magnetic field-dependent contact resistance, where the practical fit function’s coefficients are determined depending on the winding force. Second, the contact resistance of each coil is partially inconsistent with the magnetoresistance of the electroplated material, i.e. copper, of the REBCO-coated conductor. This paper will present the measurement results in detail, discuss them with Kohler’s rule, and formulate the contact resistance using winding force and magnetic field terms.

Bang, Jeseok (ORCID:0000000247616334)↗

Investigating Material Properties of Subsurface Rock Formations Modified by Engineering Mineral Precipitation (Final Scientific and Technical Report)

Montana State University’s (MSU) Energy Research Institute (ERI), in collaboration with the Center for Biofilm Engineering (CBE) and the Department of Civil Engineering (CE), has conducted a long‐term research program aimed at developing a novel cementing agent to address wellbore integrity and reduce the unwanted upward migration of fluids and greenhouse gases from the subsurface. The primary technology developed through this research program is known as ureolysis‐induced calcite precipitation (UICP), which harnesses bio‐chemical processes to precipitate calcium carbonate (CaCO 3 ). The same general process can also be called microbially-induced calcium carbonate precipitation (MICP) when microbes provide the process-catalyzing urease enzyme. Both terms are used in this report. Results have conclusively demonstrated that, if properly controlled, UICP can successfully seal fractures, high permeability zones, and compromised cement in the vicinity of wellbores and in nearby caprock. This technology has been successfully deployed to mitigate annular leakage in two test wells and over sixty commercial wells with a 100% success rate. This success in downhole deployment generates consideration of other subsurface applications where UICP could provide benefit to the energy sector, such as shale property modification for unconventional oil and gas recovery. The focus of this research project was to investigate fundamental material and mechanical properties of select shale cores and analyze how these properties change due to engineered mineral precipitation with the intent to control these properties to achieve a range of engineering objectives. Ultimately, the project aim was to identify valuable new areas where application of UICP might contribute to national energy security and environmental protection. The research workplan coupled UICP treatment of core samples, nuclear magnetic resonance (NMR) characterization, and mechanical strength testing at MSU with advanced X‐Ray micro-computed tomography (μCT) imaging and numerical modeling performed by collaborators at two national laboratories, the National Energy Technology Laboratory (NETL) and Lawrence Berkeley National Laboratory (LBNL). Experimental results are useful to inform geo-mechanical models which could be applied to predict mineralized rock formation behavior at field scale. Our findings suggest that NMR and μCT methods to detect and quantify biomineral formation in shale fractures are complementary and consistent with each other. Either could be used to estimate the volume of new mineral formed by UICP in shale fractures. The use of surfactants and guar gum to enhance biomineral precipitation in shale fractures merits further research. UICP can, under some conditions, increase the tensile strength of sealed shale fractures beyond that of the intact shale. These findings demonstrate that continued research in this area may be valuable to understanding and improving shale resource recovery techniques.

58 GEOSCIENCES↗

Cryo-quenched Fe–Ni–Cr alloy decorative steel single crystals II: Alloy phases, structure, hardness, tensile, tribological, magnetic and electronic properties

We have previously reported (Boatner et al., J. Alloys Compd. 691 (2017) 666–671) on the discovery, formation, processing, and application of a new decorative ternary steel alloy and on its use in a wide range of practical applications including: custom and commercial knives, art objects, jewelry, electronics, and furniture. This decorative property results when polished single crystals of the 70 wt%Fe-15 wt%Ni-15 wt% Cr austenitic alloy are cryo-quenched into the martensitic phase resulting in the formation of a three-dimensional raised pattern of mixed austenitic/martensitic laths. These laths propagate across large dimensions of the material due to the absence of grain boundaries in the single crystal. The macroscopic optically reflective 3-D decorative pattern reproduces the structural symmetry inherent in the single-crystal orientation. This pattern results solely from the metallurgical phase properties of the ternary alloy and is completely distinct from the properties of Damascus steels or more modern so-called pattern-welded steels. Here we use X-ray diffraction, nanoindentation, hardness measurements/scratch testing, tribological measurements, and alloy resistivity and magnetization methods to obtain a more fundamental and comprehensive study of the effects of the austenitic/martensitic phase transition on the structural and physical properties of the 70 wt%Fe-15 wt%Ni-15 wt% Cr alloy. These results reveal new insight into irreversible phenomena that are associated with the inhibited phase transition on heating of the two-phase, mixed austenitic/martensitic structure that is formed subsequent to cryo-quenching the alloy crystal to 77 K.

36 MATERIALS SCIENCE↗

Effects of magnetic field assisted heat treatment on the microstructure and mechanical properties of Fe-0.63 %C alloy

This study investigates the influence of an applied magnetic field on the microstructural evolution and mechanical properties of hypoeutectoid steels subjected to heat treatment. Tensile tests and microstructural analysis were performed on samples processed under varying magnetic field strengths (0 T, 5 T, and 9 T) and different austenitization incubation times. The results indicate that the application of a magnetic field alters the fraction of proeutectoid ferrite phase without changing the cooling rates and heat treatment process. Additionally, pearlite microstructural features such as lamellar spacing and misorientation angles exhibit variations under different field strengths. While the pearlite nodule diameter remains largely unaffected, an increase in percentage elongation and strength is observed in the 5 T treated sample, attributed to changes in microstructural features with the magnetic field. Additionally, the percentage elongation is reduced in the samples heat treated with reduced austenitization incubation times. The study further demonstrates that low-angle misorientations increased in the samples taken parallel to the magnetic field direction, influencing the mechanical response. These findings suggest that applying a magnetic field during heat treatment provides an additional driving force for phase transformations, offering a manufacturing process for tailoring microstructures and optimizing mechanical properties. Moreover, integrating magnetic fields in heat treatment processes has potential benefits in energy efficiency.

High magnetic field↗

Challenges in Pulsed-Field Gradient Nuclear Magnetic Resonance on Magnetically Heterogeneous Interfaces: Sequence and Field-Dependent Apparent Diffusion Coefficients

It is well known that the internal gradient (gi) that exists within pores haunts the diffusion coefficient (D) as measured by the pulsed-field gradient (PFG) nuclear magnetic resonance (NMR). Several PFG-NMR methods developed to determine an accurate D were not successful. Then, the steady-state diffusion coefficient (Dapp,8) for the cation [C4mim]+ of [C4mim][Tf2N]; [1-butyl-3-methylimidazolium][bis(trifluoromethylsulfonyl)imde] ionic liquid confined in ordered mesoporous carbon (OMC) were determined by comparing Dapp,8 obtained from 1H PFG-NMR performed with three different stimulated echo sequences: STE, APFG, and MPFG under the two external magnetic field strength, B0 = 9.4 and 14.1 Tesla. The measured Dapp,8 which is an order of magnitude smaller than D of bulk [C4mim][Tf2N], is in good agreement between APFG and MPFG both in B0 = 9.4 and 14.1 Tesla. However, the strong gi artifact, which caused apparent diffusion coefficient (Dapp) depending strongly and weakly on B0 and temperature, respectively, in diffusion-time dependent Dapp, Dapp(?) obtained from a sequence with monopolar gradients (STE) was suppressed by using sequences employing bipolar gradients (APFG and MPFG) in the region of steady-state diffusion. But incompletely suppressed gi artifact resulting in the different behaviors of the early part of Dapp(?) between the sequences leads a ˜ 0.6 and 0.9 in MPFG and APFG, respectively, in the relationship between mean squared displacement and diffusion time: = 2Dta, where a = 0.5 and 1 for 1-dimensional single file diffusion and 3-dimensional bulk diffusion, respectively. The above observations clearly show that the diffusion behavior of ions/molecules within the pores and pore structure, such as the surface-to-volume ratio? (D?_app (?)=D_0 [1-4/(9vp) S/V v(D_0 ?)]) and tortuosity (T = D0/Dapp,8), are possible to be misunderstood, especially in the systems with a non-negligible gi. This work demonstrates that it may be necessary to test several PFG sequences under multiple external magnetic fields for the correct determination of the diffusion behavior of ions/molecules in the pores with a larger internal gradient, gi.

Han, Kee Sung↗

The Simons Observatory: Magnetic Shielding Measurements for the Universal Multiplexing Module

The Simons Observatory (SO) includes four telescopes that will measure the temperature and polarization of the cosmic microwave background using over 60,000 highly sensitive transition-edge bolometers (TES). These multichroic TES bolometers are read out by a microwave RF SQUID multiplexing system with a multiplexing factor of 910. Given that both TESes and SQUIDs are susceptible to magnetic field pickup and that it is hard to predict how they will respond to such fields, it is important to characterize the magnetic response of these systems empirically. This information can then be used to limit spurious signals by informing magnetic shielding designs for the detectors and readout. This paper focuses on measurements of magnetic pickup with different magnetic shielding configurations for the SO universal multiplexing module (UMM), which contains the SQUIDs, associated resonators, and TES bias circuit. The magnetic pickup of a prototype UMM was tested under three shielding configurations: no shielding (copper packaging), aluminum packaging for the UMM, and a tin/lead-plated shield surrounding the entire dilution refrigerator 100 mK cold stage. We also present measurements of the pickup in the UMM when aluminum feedhorns are installed. The measurements show that the aluminum packaging outperforms the copper packaging by a shielding factor of 8-10, and adding the tin/lead-plated 1K shield further increases the relative shielding factor in the aluminum configuration by 1-2 orders of magnitude. Furthermore, the addition of feedhorns provides a factor of 30 improvement when the tin/lead shield is not installed and a factor of 5 improvement when it is.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Review of the Generic Grid-Forming Model Used by the System Operator in Chile

The objective in this project is to verify the applicability of using generic electro-magnetic transient domain models of GFM technology through a wide range of tests and system conditions proposed by subject matter experts of GFM technology through a wide range of tests and system conditions proposed by subject matter experts. For this study, we used the generic GFM electro-magnetic transient model available in the EMTP (Electromagnetic Transient Program) software library, and we assessed the model’s various GFM capabilities through 12 tests. In this report, we compare the performance of the model with that of an original equipment manufacturer (OEM) GFM model. We also share the key insights and lessons learned from this work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MRSt S Specifications Report

The MRSt spectrometer is a magnetic spectrometer designed for momentum analyzing deuterons (10.7 – 14.2 MeV). The MRSt spectrometer will be attached to the target chamber of the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNS), Livermore, California. This document defines the technical requirements for the design, analysis, fabrication, inspection, testing and delivery of the complete set of magnets, vacuum chambers, and accessories to become part of the spectrometer. The interface issues, including the support structures, need to be defined later by LLNS and the vendor, which will require time and dialog before a solution can be found. This “Specification Report for the MRSt-S System”, January 19, 2020 is based on and supersedes an earlier version “Specification Report for the MRSt-S System”, May 1, 2019 The vendor shall check these specifications for possible conflicts between statements in this document. Possible solutions to any such conflicts should be included in the proposal submitted by the vendor. The proposal shall also include the delivery FOB destination LLNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a second COMB dipole magnet with STAR wires

Rare-Earth Barium Copper Oxide (REBCO) coated conductors are an attractive option for application in high-field accelerator magnets due to their high critical field and the convenience of fabrication without heat treatment compared to some other superconductors. Fermilab plays a vital role in superconducting accelerator magnet R&D under the framework of the U.S. Magnet Development Program. An integral part of that program is the accelerator magnet development based on REBCO conductors to demonstrate self-fields of 5 T or greater compatible with operation in hybrid configurations to generate fields beyond 16 T for future High Energy Physics (HEP) applications. A small, two-layer REBCO dipole magnet based on the Conductor on Molded Barrel (COMB) magnet technology, developed at Fermilab with Symmetric Tape Round (STAR®) wires from AMPeers LLC was recently fabricated and tested in liquid helium, demonstrating the design feasibility. A second dipole magnet based on the same technology is currently under development at Fermilab. The coil has a 60-mm clear bore and a 120-mm OD and consists of six layers of STAR® conductor, which allows to significantly increase the magnetic field compared to the previous design, and potentially probe the 5 T self-field target. This presentation reports the progress in the magnet development.

Kashikhin, Vadim [Fermilab]↗

Analysis of Screening Current Effects in a Hybrid Nb$_{3}$Sn/REBCO Superconducting Accelerator Magnet Using a T - A Formulation

To explore the feasibility of using high-temperature superconducting (HTS) REBCO coated conductors in future accelerator magnets, two REBCO flat racetrack coils were fabricated using 4-mm wide EuBCO tapes at the High Energy Accelerator Research Organization (KEK). These coils were tested as an insert inside a Nb$_{3}$Sn common-coil dipole magnet, which provides a background field of up to $\sim$ 9.5T, at the Brookhaven National Laboratory (BNL). REBCO tapes offer exceptionally high critical current density under strong magnetic fields; however, they also exhibit significant magnetization due to screening currents, leading to magnetic field errors. Here, this study presents a 2D finite element model of screening current-induced fields (SCIF) in REBCO coils using the T-A formulation, along with the results obtained. Simulations were then performed for two KEK test cases: one where the REBCO conductors were oriented with the HTS tapes parallel to the background field, and another where the tapes were perpendicular to it. Since screening currents also influence the stress distribution and increase the peak stress in the coils, the mechanical effects of these currents were analyzed. The implications of these simulation and test results for the design of Nb$_{3}$Sn/REBCO superconducting accelerator magnets are discussed.

Accelerator magnets↗

A Large Bore Conduction Cooled Superconducting Magnet for the Princeton Axion Search

Princeton University (PU) is designing and building a new experiment, called the Princeton Axion Search (PXS), that aims to discover (or exclude) Quantum Chromodynamics (QCD) axions in the 0.8–2 μeV mass range that are the cosmological dark matter. Core elements of the experiment are new, and in particular new to the search for axion dark matter. An essential component of the experiment is a 5 T superconducting magnet with a total bore volume of ~500 L. The Princeton Plasma Physics Laboratory (PPPL), a Department of Energy (DOE) Laboratory managed by Princeton University, has the unique expertise and experimental facilities to design and construct such a solenoid magnet assembled with the cavity resonator for PXS. To support this, PPPL utilizes legacy ITER-Nb3Sn conductors, along with its experimental facilities and expertises to design, build and test low-cost conduction-cooled superconducting solenoid magnets to be integrated into the axion detector. This paper discusses the various coil design and integration challenges in the large bore conduction cooled magnet in support of PXS. In conclusion, the proposed instrumental methods will help optimize the path to future and more ambitious axion searches at lower masses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of a highly conductive warm dense state of water with ultrafast pump–probe free-electron-laser measurements

The electrical conductivity of water under extreme temperatures and densities plays a central role in modeling planetary magnetic fields. Experimental data are vital to test theories of high-energy-density water and assess the possible development and presence of extraterrestrial life. These states are also important in biology and chemistry studies when specimens in water are confined and excited using ultrafast optical or free-electron lasers (FELs). Here we utilize femtosecond optical lasers to measure the transient reflection and transmission of ultrathin water sheet samples uniformly heated by a 13.6 nm FEL approaching a highly conducting state at electron temperatures exceeding 20 000 K. The experiment probes the trajectory of water through the high-energy-density phase space and provides insights into changes in the index of refraction, charge carrier densities, and AC electrical conductivity at optical frequencies. At excitation energy densities exceeding 10 MJ/kg, the index of refraction falls to n = 0.7, and the thermally excited free-carrier density reaches ne = 5 × 1027 m−3, which is over an order of magnitude higher than that of the electron carriers produced by direct photoionization. Significant specular reflection is observed owing to critical electron density shielding of electromagnetic waves. The measured optical conductivity reaches 2 × 104 S/m, a value that is one to two orders of magnitude lower than those of simple metals in a liquid state. At electron temperatures below 15 000 K, the experimental results agree well with the theoretical calculations using density-functional theory/molecular-dynamics simulations. With increasing temperature, the electron density increases and the system approaches a Fermi distribution. In this regime, the conductivities agree better with predictions from the Ziman theory of liquid metals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct‐Write Printed Contacts to Layered and 2D Materials

Advancements in fabrication methods have shaped new computing device technologies. Among these methods, depositing electrical contacts to the channel material is fundamental to device characterization. Novel layered and 2D materials are promising for next-generation computing electronic channel materials. Direct-write printing of conductive inks is introduced as a surprisingly effective, significantly faster, and cleaner method to contact different classes of layered materials, including graphene (semi-metal), MoS 2 (semiconductor), Bi-2212 (superconductor), and Fe 5 GeTe 2 (metallic ferromagnet). Based on the electrical response, the quality of the printed contacts is comparable to what is achievable with resist-based lithography techniques. These devices are tested by sweeping gate voltage, temperature, and magnetic field to show that the materials remain pristine post-processing. This work demonstrates that direct-write printing is an agile method for prototyping and characterizing the electrical properties of novel layered materials.

2D materials↗

Dynamic Nuclear Polarization of Metal-Doped Oxide Glasses: A Test of the Generality of Paramagnetic Metal Polarizing Agents

Nuclear magnetic resonance (NMR) spectroscopy can provide unique, atomic-level insights into the structure and dynamics of materials, but its applications are impeded by the intrinsically low sensitivity. Dynamic nuclear polarization (DNP) is poised to overcome this limitation, and indeed has revolutionized the study of surfaces; however, the current approaches are ill-suited for bulk solids. One potential pathway toward the hyperpolarization of bulk solids by DNP is through the inclusion of paramagnetic metal ions that can serve as polarizing agents. Here, we compared the relative performance of two such dopants, Mn 2+ and Gd 3+ , in three series of oxide glasses having chemical environments representative of those found in other crystalline and amorphous solids. In our studies, Gd 3+ outperformed Mn 2+ , consistently providing more than one order of magnitude greater time savings. We attributed this difference mainly to the lack of hyperfine interaction to 55 Mn.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗