Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “long-term degradation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Numerical Investigation of Heat Transfer and Fluid Flow within Electrochemical Hydrogen Peroxide Generation Unit

Long-term manned space missions require the onboard production of disinfectants essential for maintaining crew health and supporting life systems. Currently, disinfection aboard the International Space Station (ISS) relies on disposable wetted wipes, which are regularly resupplied from Earth. This approach imposes a significant burden on resupply logistics, storage, and waste management. To address these challenges and support future missions, efforts are underway to develop an in-situ solution that electrochemically generates hydrogen peroxide disinfectant using onboard resources. In collaboration with NASA, Faraday Technology, Inc. has advanced this concept through a series of Small Business Innovation Research (SBIR) projects, resulting in the development of a Peroxide Generation Unit (PGU). The PGU can produce up to 3 wt.% hydrogen peroxide on-demand at a rate of 1 liter per day, providing a sustainable alternative to Earth-dependent supplies. The resulting aqueous hydrogen peroxide (H₂O₂) is an effective disinfectant, safe for crew use, compatible with spacecraft systems, and free from volatiles, off-gassing, or residues. This innovation offers a reliable, efficient solution for onboard disinfection, reducing dependence on Earth-based resupply while ensuring the health and safety of space crews. Generating hydrogen peroxide at the required rate needs high voltages and currents, exceeding 20V and 2A respectively, which leads to significant heat generation from Joule heating. This temperature rise poses a risk to sensitive system components, especially critical and expensive membranes that can degrade under thermal stress. To mitigate this risk, the thermal, fluid, and electrical flows within the system are modeled computationally using the commercial software COMSOL. The numerical simulations are validated against experimental data from both sub-scale and alpha-scale systems. Once verified, the model is employed to identify thermal hotspots, investigate their underlying causes, and explore solutions to prevent them.

Life Support Systems (LSS)↗

Revealing Progressive Degradation of Cobalt Oxide Nanoparticles During Thermochemical Redox Cycling via Operando STEM-EELS

Metal oxides are promising materials for long-duration thermochemical energy storage. Efforts to characterize their reaction kinetics, conversion rate, and morphological evolution during thermochemical cycling have largely focused on bulk and microscale measurements. However, the design of nanostructured metal oxides could improve the reaction reversibility and kinetics, warranting the development of platforms to investigate how these materials behave at the nanoscale. Here, we demonstrate the use of correlative, time-resolved electron energy loss spectroscopy and imaging in an environmental transmission electron microscope for studying the thermochemical cyclability of cobalt oxide nanoparticles with high spatial and temporal resolution. The spectroscopic data reveal a striking decrease in reaction kinetics after the first cycle, resulting from sintering-driven nanostructural densification. Comparison between cycling in humid and dry air shows that atmospheric conditions can modulate reaction transition temperatures but have limited effects on sintering over multiple cycles, suggesting long-term durability will instead rely on synthetic and/or nanostructural modifications.

25 ENERGY STORAGE↗

Hole transport layer selection for stable and efficient carbon electrode-based perovskite solar cells

Perovskite solar cell (PSC) technology has achieved remarkable progress, with champion power conversion efficiencies (PCE) exceeding 26%. However, the long-term stability of PSCs remains a significant barrier to their widespread commercialization. Carbon-based PSCs (C-PSCs) have gained attention as a promising cost-effective and scalable production solution, replacing expensive metal electrodes and offering improved stability. Despite these advantages, C-PSCs face challenges in matching the performance of noble metal-based PSCs, particularly in terms of carrier extraction efficiency and reduced carrier recombination at the carbon/perovskite interface. The selection of hole transport materials (HTMs) is crucial for optimizing this interface, but comprehensive studies on HTM selection for C-PSCs are limited. This study systematically investigated three commonly used hole transport layers (HTLs): Spiro-OMeTAD, CuSCN, and PTAA. Our results show that Spiro-OMeTAD-based C-PSCs exhibit the best overall performance, achieving a PCE of 19.29%. CuSCN-based devices, while lower in efficiency (11.94% PCE), demonstrated superior stability, retaining approximately 60% of their initial performance after 500 hours under ambient conditions. PTAA-based devices achieved a PCE of 12.92% but exhibited significant degradation, maintaining only ∼35% of their original efficiency over the same duration. These findings highlight the importance of selecting HTLs that balance performance and stability and emphasize the need for further optimization to enhance the commercial viability of C-PSCs.

14 SOLAR ENERGY↗

Monitoring of Liquid Metal Reactor Heater Zones with Recurrent Neural Network Learning of Temperature Time Series

Advanced high-temperature fluid reactors (ARs), such as sodium fast reactors (SFRs) and molten salt cooled reactors (MSCRs) utilize high-temperature fluids at ambient pressure. To melt the fluid during reactor startup and prevent fluid freezing during cooldown, the thermal–hydraulic systems of such ARs include heater zones consisting of specific heaters with controllers, temperature sensors, and thermal insulation. The failure of heater zones due to insulation material degradation or improper installation, resulting in parasitic heat losses, can lead to fluid freezing. The detection of faults using a heat-transfer model is difficult because of a lack of knowledge of the experimental details. Data-driven machine learning of heater zone temperature time series offers a viable alternative. In this study, we benchmarked the performance of recurrent neural networks (RNNs) in an analysis of heat-up transient temperature time series of heater zones installed on a liquid sodium vessel. The RNN models include long short-term memory (LSTM) and gated recurrent unit (GRU) networks, as well as their bi-directional variants, BiLSTM and BiGRU. Anomalous temperature points were designated using a percentile-based threshold applied to residual fluctuations in the detrended temperature time series. Additionally, the impact of the exponentially weighted moving average (EWMA) method on detection accuracy was examined. The RNN models’ performance was assessed using precision, recall, and F 1 score metrics. Results demonstrated that RNN models effectively detect anomalies in temperature time series with the best models for each heater zone achieving F 1 scores of over 93%. To explain the variations in RNN model performance across different heater zones, we used Kullback–Leibler (KL) divergence to quantify the relative entropy between training and testing data, and the Detrended Fluctuation Analysis (DFA) to assess long-range temporal correlations. For datasets with strong long-range correlations and minimal relative entropy between training and testing data, GRU is the best-performing model. When the data exhibits weaker long-term correlations and a significant relative entropy between training and testing distributions, BiGRU shows the best performance. For the data sets with intermediate values of both KL divergence and DFA, the best performance is obtained with LSTM and BiLSTM, respectively.

gated recurrent unit↗

Study of advanced techniques for determining the long term performance of components

The application of existing and new technology to the problem of determining the long-term performance capability of liquid rocket propulsion feed systems is discussed. The long term performance of metal to metal valve seats in a liquid propellant fuel system is stressed. The approaches taken in conducting the analysis are: (1) advancing the technology of characterizing components through the development of new or more sensitive techniques and (2) improving the understanding of the physical of degradation.

Source record↗

The effects of cockpit environment on long-term pilot performance

A fixed-base helicopter simulator was used to examine pilot performance as influenced by noise, vibration, and fatigue. Subjects flew the simulator for periods ranging between three and eight hours while exposed to vibrations (at 17 Hz) ranging from 0.1 to 0.3 g, and noise stimuli varying between 74 (ambient) and 100 dB. Despite reports of extreme fatigue on these long flights, subject performance did not degrade. Within the limits of this study, performance tended to improve as environmental stress increased. However, subjects did suffer from lapses resulting in abnormally poor performance. These lapses are probably of short duration (seconds) and occur at unpredictable times. If such lapses occur in actual flight, they could provide an explanation for many so-called 'pilot error' accidents.

Stave, A. M.↗

Long-term weathering effects on the thermal performance of the Libbey-Owens-Ford (liquid) solar collector

Thermal performance tests were conducted on the Libbey-Owens-Ford liquid collector, following long term exposure to natural weathering conditions. Visual inspection of the collector, prior to the retest, indicated noticeable clouding of the inner cover glass, probably resulting from outgassing of the insulation. The absorber plate also showed some discoloration. The test results indicated that performance degradation had occurred at inlet temperatures significantly above ambient. The change in the slope of the efficiency curve, from the original data, is a direct indicator of an increase in the collector heat loss coefficient.

Source record↗

The EMC of satellite power systems and DoD C-E systems

The solar power satellite (SPS) technical parameters that are needed to accurately assess the electromagnetic compatibility (EMC) between SPS systems and DoD communications-electronics (C-E) systems are identified and assessed. The type of electromagnetic interactions that could degrade the performance of C-E systems are described and the major military installations in the southwestern portions of CONUS where specially sensitive C-E systems are being used for combat training and evaluation are identified. Classes of C-E systems that are generally in the vicinity of these military installations are considered. The Technical parameters that govern the degree of compatibility of the SPS with these C-E systems, and some technical requirements that are necessary to ensure short-term and long-term EMC are identified.

Atkinson, J. H.↗

Working group written presentation: Atomic oxygen

Earlier Shuttle flight experiments have shown NASA and SDIO spacecraft designed for operation in low-Earth orbit (LEO) must take into consideration the highly oxidative characteristics of the ambient flight environment. Materials most adversely affected by atomic oxygen interactions include organic films, advanced (carbon-based) composites, thermal control coatings, organic-based paints, optical coatings, and thermal control blankets commonly used in spacecraft applications. Earlier results of NASA flight experiments have shown prolonged exposure of sensitive spacecraft materials to the LEO environment will result in degraded systems performance or, more importantly, lead to requirements for excessive on-orbit maintenance, with both conditions contributing significantly to increased mission costs and reduced mission objectives. Flight data obtained from previous Space Shuttle missions and results of the Solar Max recovery mission are limited in terms of atomic oxygen exposure and accuracy of fluence estimates. The results of laboratory studies to investigate the long-term (15 to 30 yrs) effects of AO exposure on spacecraft surfaces are only recently available, and qualitative correlations of laboratory results with flight results have been obtained for only a limited number of materials. The working group recommended the most promising ground-based laboratories now under development be made operational as soon as possible to study the full-life effects of atomic oxygen exposure on spacecraft systems.

Leger, Lubert J.↗

LaRC-developed catalysts for CO2 lasers

Pulsed CO2 lasers have many remote sensing applications from space, airborne, and ground platforms. The NASA Laser Atmospheric Wind Sounder (LAWS) system will be designed to measure wind velocities from polar earth orbit for a period of up to three years. Accordingly, this and other applications require a closed-cycle pulsed CO2 laser which necessitates the use of an efficient CO-O2 recombination catalyst for these dissociation products which otherwise would degrade the laser operation. The required catalyst must not only operate at low temperatures but also must operate efficiently for long time periods. The research effort at NASA LaRC has centered around development and testing of CO oxidation catalysts for closed-cycle, pulsed, common and rare-isotope CO2 lasers. Researchers examined available commercial catalysts both in a laser and under simulated closed-cycle laser conditions with efforts aimed toward a thorough understanding of the fundamental catalytic reaction. These data were used to design and synthesize new catalyst compositions to better meet the catalyst requirements for closed-cycle pulsed CO2 lasers. Syntheses and test results for catalysts developed at Langley Research Center which have significantly better long-term decay characteristics than previously available catalysts and at the same time operate quite well under lower temperature conditions are discussed.

Upchurch, Billy T.↗

Effect of short-term exposure to stereoscopic three-dimensional flight displays on real-world depth perception

High-fidelity color pictorial displays that incorporate depth cues in the display elements are currently available. Depth cuing applied to advanced head-down flight display concepts potentially enhances the pilot's situational awareness and improves task performance. Depth cues provided by stereopsis exhibit constraints that must be fully understood so depth cuing enhancements can be adequately realized and exploited. A fundamental issue (the goal of this investigation) is whether the use of head-down stereoscopic displays in flight applications degrade the real-world depth perception of pilots using such displays. Stereoacuity tests are used in this study as the measure of interest. Eight pilots flew repeated simulated landing approaches using both nonstereo and stereo 3-D head-down pathway-in-the-sky displays. At this decision height of each approach (where the pilot changes to an out-the-window view to obtain real-world visual references) the pilots changed to a stereoacuity test that used real objects. Statistical analysis of stereoacuity measures (data for a control condition of no exposure to any electronic flight display compared with data for changes from nonstereo and from stereo displays) reveals no significant differences for any of the conditions. Therefore, changing from short-term exposure to a head-down stereo display has no more effect on real-world relative depth perception than does changing from a nonstereo display. However, depth perception effects based on sized and distance judgements and on long-term exposure remain issues to be investigated.

Busquets, Anthony M.↗

Solar variation 1979-1987 estimated from an empirical model for changes with time in the sensitivity of the solar backscatter ultraviolet instrument

A model is developed that describes changes in the sensitivity of the solar backscatter UV instrument deployed with Nimbus 7 to study variations with time in solar irradiance. The exponential decay of instrument exposure to the sun and that of time are combined, and the product is used to describe the sensitivity change. Measured UV irradiances are employed to develop the values of the exponential decays, and the degradation coefficients for time dependence are found to vary with time at shorter wavelengths. Instrument sensitivity is described in terms of a functional relationship based on exponential decay with time with time-varying time dependence and on exponential decay with exposure with constant exposure dependence. The relationship provides a technique for treating data from the solar backscatter UV instrument both at short- and long-term intervals, and solar irradiance is calculated based on the approach.

Schlesinger, Barry M.↗

Ni-MH storage test and cycle life test

Gates Aerospace Batteries is conducting two long term test programs to fully characterize the NiMH cell technology for aerospace applications. The first program analyzes the effects of long term storage upon cell performance. The second program analyzes cycle life testing and preliminary production lot testing. This paper summarizes these approaches to testing the NiMH couple and culminates with initial storage and testing recommendations. Long term storage presents challenges to deter the adverse condition of capacity fade in NiMH cells. Elevated but stabilized pressures and elevated but stabilized end-of-charge voltages also appear to be a characteristic phenomenon of long term storage modes. However, the performance degradation is dependent upon specific characteristics of the metal-hydride alloy. To date, there is no objective evidence with which to recommend the proper method for storage and handling of NiMH cells upon shipment. This is particularly critical due to limited data points that indicate open circuit storage at room temperature for 60 to 90 days will result in irrecoverable capacity loss. Accordingly a test plan was developed to determine what method of mid-term to long-term storage will prevent irrecoverable capacity loss. The explicit assumption is that trickle charging at some rate above the self-discharge rate will prevent the irreversible chemical changes to the negative electrode that result in the irrecoverable capacity loss. Another premise is that lower storage temperatures, typically 0 C for aerospace customers, will impede any negative chemical reactions. Three different trickle charge rates are expected to yield a fairly flat response with respect to recoverable capacity versus baseline cells in two different modes of open circuit. Specific attributes monitored include: end-of-charge voltage, end-of-charge pressure, mid-point discharge voltage, capacity, and end-of-discharge pressure. Cycle life testing and preliminary production lot testing continue to dominate the overall technology development effort at GAB. The cell life test program reflects continuing improvements in baseline cell designs. Performance improvements include lower and more stable charge voltages and pressures. The continuing review of production lot testing assures conformance to the design criteria and expectations. This is especially critical during this period of transferring technology from research and development status to production.

Dell, R. Dan↗

Escarpment evolution on high-elevation rifted margins: Insights derived from a surface processes model that combines diffusion, advection and reaction

Experiments with a surface processes model of large-scale (1-1000 km) long-term (1-100 m.y.) erosional denudation are used to establish the controls on the evolution of a model escarpment that is related to the rifting of a continent. The mdoel describes changes in topographic form as a result of sumultaneous short- and long-range mass transport representing hillslope (diffusive) processes and fluvial transport (advection), repsectively. Fluvial entrainment is modeled as a first-order kinetic reaction which reflects the erodibility of the substrate, and therefore the fluvial system is not necessarily carrying at capacity. One dimensional and planform models demonstrate that the principal controls on the evolution of an initially steep model escarpment are (1) antecedent topography/drainage; (2) the timesale (or equivalently a length scale) in the fluvial entrainment reaction; (3) the flexural response of the lithosphere to denudation; and (4) the relative efficiencies of the short- and long-range transport processes. When rainfall and substrate lithology are uniform, a significant amount of discharge draining over the escarpment top causes it to degrade. Only when the top of the model escarpment coincides with a drainage divide can escarpment retreat occur for these conditions. An additional requirement for retreat of a model escarpment without decline is a long reaction time scale for fluvial entrainment. This corresponds to a substrate that is hard to detach by flucial erosion, and therefore to fluvial erosion that is not transport limited. Coninuous backtilting of an escarpment due ot flexural isostatic uplift in response to denudational unloading helps maintain the scarp top as a divide. It is essntial if the escarpment gradient is to be preserved during retreat in a uniform lithology. Low flexural rigidieties propote steep and slowly retreating escarpments. For given rainfall and substrate conditions, the morphology of a retraeating model escarpment is determined by the ratio of hte short-range diffusive and long range advective transport efficiencies. A low ration (which is interpreted to correspond to a more humid, temperate climate) produces a convex upper slope, and concave lower slope morphology and only major escarpments are predicted to preserve a high scarp gradient. Lithological contrasts in hte model produce more complex morphologies and predict the formation of scarps crowned by an erosionaly resistant caprock. However, resistant caprocks are not an essential requirement for model scarps to retreat. We conclude that the inferred controls and model behavior are both consistent with the present-day morphology of rifted continental margins and with modern conceptual models of landscape evolution.

Kooi, Henk↗

Photo-recovery of electron-irradiated GaAs solar cells

The first long-term (3000 hours) UV testing of unirradiated and 1 MeV electron-irradiated GaAs solar cells, with multilayer-coated coverslides to reduce solar array operating temperature, has produced some unexpected and important results. Two results, independent of the coverslide coatings, are of particular importance in terms of the predictability of GaAs solar-array lifetime in space: ( 1) The GaAs/Ge solar cells used for this series of tests displayed a much higher radiation degradation than that predicted based on JPL Solar Cell Radiation Handbook data. Covered cells degraded more in Isc than did bare cells. Short-term illumination at 60 C did not produce significant recovery (-1%) of the radiation damage. (2) However, electron radiation damage to these GaAs solar celIs anneals at 40 C when exposed to approximately 1 sun AM0 UV light sources for extended periods. The effect appears to be roughly linear with time (-1% of lsc per 1000 UVSH), is large (greater than or equal to 3%), and has not yet saturated (at 3000 hours). This photo-recovery of radiation damage to GaAs solar cells is a new effect and potentially important to the spacecraft community. The figure compares the effects of extended UV on irradiated and unirradiated GaAs solar cells with INTELSAT-6 Si cells. The effect and its generality, the extent of and conditions for photo-recovery, and the implications of such recovery for missions in radiation environments have not yet been determined.

Meulenberg, Andrew↗

Fiber-Optic Temperature Sensor Using a Thin-Film Fabry-Perot Interferometer

A fiber-optic temperature sensor was developed that is rugged, compact, stable, and can be inexpensively fabricated. This thin-film interferometric temperature sensor was shown to be capable of providing a +/- 2 C accuracy over the range of -55 to 275 C, throughout a 5000 hr operating life. A temperature-sensitive thin-film Fabry-Perot interferometer can be deposited directly onto the end of a multimode optical fiber. This batch-fabricatable sensor can be manufactured at a much lower cost than can a presently available sensor, which requires the mechanical attachment of a Fabry-Perot interferometer to a fiber. The principal disadvantage of the thin-film sensor is its inherent instability, due to the low processing temperatures that must be used to prevent degradation of the optical fiber's buffer coating. The design of the stable thin-film temperature sensor considered the potential sources of both short and long term drifts. The temperature- sensitive Fabry-Perot interferometer was a silicon film with a thickness of approx. 2 microns. A laser-annealing process was developed which crystallized the silicon film without damaging the optical fiber. The silicon film was encapsulated with a thin layer of Si3N4 over coated with aluminum. Crystallization of the silicon and its encapsulation with a highly stable, impermeable thin-film structure were essential steps in producing a sensor with the required long-term stability.

Beheim, Glenn↗

Cyclic Fiber Push-In Test Monitors Evolution of Interfacial Behavior in Ceramic Matrix Composites

SiC fiber-reinforced ceramic matrix composites are being developed for high-temperature advanced jet engine applications. Obtaining a strong, tough composite material depends critically on optimizing the mechanical coupling between the reinforcing fibers and the surrounding matrix material. This has usually been accomplished by applying a thin C or BN coating onto the surface of the reinforcing fibers. The performance of these fiber coatings, however, may degrade under cyclic loading conditions or exposure to different environments. Degradation of the coating-controlled interfacial behavior will strongly affect the useful service lifetime of the composite material. Cyclic fiber push-in testing was applied to monitor the evolution of fiber sliding behavior in both C- and BN-coated small-diameter (15-mm) SiC-fiber-reinforced ceramic matrix composites. The cyclic fiber push-in tests were performed using a desktop fiber push-out apparatus. At the beginning of each test, the fiber to be tested was aligned underneath a 10- mm-diameter diamond punch; then, the applied load was cycled between selected maximum and minimum loads. From the measured response, the fiber sliding distance and frictional sliding stresses were determined for each cycle. Tests were performed in both room air and nitrogen. Cyclic fiber push-in tests of C-coated, SiC-fiber-reinforced SiC showed progressive increases in fiber sliding distances along with decreases in frictional sliding stresses for continued cycling in room air. This rapid degradation in interfacial response was not observed for cycling in nitrogen, indicating that moisture exposure had a large effect in immediately lowering the frictional sliding stresses of C-coated fibers. These results indicate that matrix cracks bridged by C-coated fibers will not be stable, but will rapidly grow in moisture-containing environments. In contrast, cyclic fiber push-in tests of both BN-coated, SiC-fiber-reinforced SiC and BNcoated, SiC-fiber-reinforced barium strontium aluminosilicate showed no significant changes in fiber sliding behavior with continued short-term cycling in either room air or nitrogen. Although the composites with BN-coated fibers showed stable short-term cycling behavior in both environments, long-term (several-week) exposure of debonded fibers to room air resulted in dramatically increased fiber sliding distances and decreased frictional sliding stresses. These results indicate that although matrix cracks bridged by BNcoated fibers will show short-term stability, such cracks will show substantial growth with long-term exposure to moisture-containing environments. Newly formulated BN coatings, with higher moisture resistance, will be tested in the near future.

Eldridge, Jeffrey I.↗

Mechanical Properties of Carbon Fiber Reinforced Composites Exposed to Cryogenic Conditions and Space Radiation via Simulation and Testing

As NASA missions extend beyond low Earth orbit, increasing reliance is placed on carbon fiber reinforced polymer (CFRP) composites for spacecraft structures where mass efficiency, durability, and long-term reliability are critical. In service, these materials are subjected to a combination of ultraviolet radiation, vacuum, ionizing radiation, atomic oxygen, and extreme thermal excursions under sustained mechanical loading. Flight systems such as the Boeing Starliner and SpaceX Dragon employ external composite structures that will experience these environments for extended durations. Although prior spaceflight and ground studies have reported limited changes in bulk mechanical properties, the synergistic effects of these environments on composite microstructure, particularly at the fiber matrix interphase, remain insufficiently characterized and represent a potential qualification and reliability risk. This study investigates the effects of short-term cryogenic exposure on a radiation shielding carbon epoxy composite, SC2020, as a ground-based analog for space relevant thermal extremes. The SC2020 material system has previously flown on the International Space Station under the Materials International Space Station Experiment (MISSE) program. Composite specimens were exposed to liquid nitrogen for 6 and 24 hours and evaluated using a multiscale characterization framework that combined ASTM D3039 tensile testing, Atomic Force Microscopy (AFM) based interphase analysis, and helium gas permeability measurements. Tensile testing showed no statistically significant or permanent degradation in global strength or modulus following cryogenic exposure. In contrast, AFM measurements revealed reductions in interphase modulus, weakened adhesion, and increased nanoscale heterogeneity, indicating localized degradation mechanisms not captured by conventional bulk testing. Gas permeability measurements showed a progressive increase in helium diffusion with exposure duration, consistent with micro-void formation or partial interfacial debonding. The results indicate that cryogenic exposure initiates degradation at the fiber matrix interphase while leaving global mechanical properties largely unchanged over short durations. These findings underscore the importance of multiscale diagnostics for identifying early-stage damage mechanisms that may influence long term performance and qualification margins for spaceflight composite structures. The data presented establish a cryogenic baseline for comparison with forthcoming MISSE flight exposure results and support ongoing NASA Established Program to Stimulate Competitive Research (EPSCoR) efforts aimed at improving composite qualification methodologies, risk assessment, and reliability prediction for space environments.

composite reliability↗